Loading...
HomeMy WebLinkAbout07010196 Site Plan The Sclmeider Corporation a901 0Us Avenue Hirtor:lc fort Harrtton Indlanapollo, indiana l6216-1037 317-626-7100 317-626-7200 FAX EllgInoeriD& s.r..yiDg lAndJcape Arch1t.ect1JI'tl GIll'1JS Geology This Plot Plan Prepared For: Beazer Homes Lot # 1103 BLOCK J (20,442 sF) Village of Westclay Section # 6001 INSTR. # 200500080672 PC 3, SLlOE 790 Hamilton County, Clay Township See 29, T18N, R03E 2616 Alcott Street Carmel, IN 46032 Prepared' Date: 12-15-06-:--B1. MBK Pial Plan Legend []QQ]] Proposed Grades 000.0 Existing Grades _ 000.0- Conlour Grade * Approx. Lateral Location _ I - Sanitary Sewer Lines -1IT- Storm Sewer Lines - IJ - Water Service LInes - - - - - - - Sub-Surface Drain Lines Gl Manhole (Sanitary or Storm) . Beehive Inlet (Storm) 11III Curb Inlel (Storm) D End Section (Storm) A Fire Hydrant _ 0 0 0 _ 0 0 0 - Flow Line of swale - Building Une (BL / BSL) - - - - - - - Easement Line (50' R/W) Communily Reslncllons: Side Yard 0 5' MIN (ONE ~DE) Reor Yard 0 N/A Aggregate 0 20~ LOT ~DTH, MIN. 5' ONE SIDE Zoning 0 51 Finished Fioor Elevation Informolion Pod Grode = 90B.9 per pion Edge of Povemenl (E.O.P.) = 909.5 LO.P. + 0.2' = Garage FIT (909.7 ) Garage FIT + 0.67' = Residenlioi FIT (910.37) ~ TYPICAL SWALE SECTlON Note: Sonllary Sewer Top of Costing informallon Upstream Manhole, TC= 90B.Ol Downslream Manhole, TC=90B.48 per record drawing Ground Cover Calculations: Drive = 156 SH Public Waik = 120 SFt Privale Walk = 61 SF t Sod = 33 SYi Sod Fronl and Side, Not Including Back and 3' Fiower Bed. Note: The contractor Is to maintain a minimum distance of len feet (10') between the sanitary sewer and water line laterals. STR.N 153 TC=9OB.01 PER RECORD ORA\\1NG Nole: This drawing is based on construction plans or record drawings, and Is not based upon a field survey, The Schneider Corporation does not warrant the accuracy or sufficiency of Ihls information. Conlroctors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation Immediately; falling to do so results in the contractors assumption of 011 liability. Note: Per Carmel ZOning ordinance 26.1.1 : The residential district limits height to twenly-five feet (25'), however a dwelling may be increased In height to thirty-five feel (35') pro~ded the side and rear yards ore increased on additional one foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height. Note: Builder to ensure positive draInage awoy_ from structure~. BLOCK' J' LOT +1103 SF 20,442 ~ ~ =.R1= ~ Assumed North Scale 1- l::I 30' o 10 20 30 ~ SCALE I' = 30' STR.1152 TC=90B.48 PER RECORO DRAv"NG 12' ALLEY ESMT "8 ~ ROLLCURB ALCOTT STREET This drawing is not intended to be represented as a retracement or original boundary survey, a route survey, or a Surveyor location Report. Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard zone AE as said land plots by scale on flood insurance rate map #18057C 0205 F for the City of Carmel, Indiana dated February 19, 2003. FLOOD HAZARO STATEMENT CERTIFICATION """\\\\11111111I11/1/111 ~~\ L 1111t'1- #~'\S .....:". C,f/t~ if <"~~"'G\s n';';';:..V+- A%< ~~..,~~ No <,;6",.?>~ I ( 50303'....) I % \. STATE OF ..... !j \ <;;>:tv 01 A~ I>:.....~ ~ ~-::!! "'S'uH\:~~ Y///IIII/IIIIIIIII\\\\\\\\\ "-"'- l . f--fl