Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A101 Reflected Ceiling Plan
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateHANAMI SUSHICarmel, IN 46032703 Veterans WayPEDCOR DESIGN GROUP LLC A101 Reflected Ceiling Plan THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2023 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS LGALGA 12/04/2023 12/04/2023 Revision ID Transmittal Set Date Transmittal Set Name Friday, December 8, 2023, /Volumes/ALLDATA/MS/DESIGN/PROJECTS/CARMEL CITY CENTER/CCC Drawings/CCC Construction Doc/Building A/A.General/BLDG A INTERIORS/TENANTS/HANAMI SUSHI/DRAWINGS/PERGOLA/Hanami Pergola.plnOPEN 12'-0" 8'-0" 8'-0"8'-0" 10'-0" +12'-0" 8'-0" 1 A301 2 A301 1 A201 2 A201 3 A201 4 A201 RCP7 RCP11 RCP16RCP16 RCP1 RCP3RCP13 RCP2 RCP1RCP1RCP1 RCP11 RCP6RCP6 RCP14 RCP14 RCP1 RCP5RCP5 RCP8 RCP4 RCP14RCP14 RCP16RCP16 RCP9 RCP15 RCP17RCP17 RCP17 RCP18 RCP18 RCP18 FFF 12'-0" 12'-0" OPEN RCP10 RCP10 RCP12 RCP10 RCP18 VESTIBULE WOMEN MEN HALL MECH. CLOS. DINING RECEPTION OFFICE SERVER KITCHEN DISHWASHING SERVICE CORRIDOR DINING PORCH EXISTING OUTDOOR COLONADE SUSHI AREA PREP AREA CLOS. BAR DINING REFLECTED CEILING PLAN NOTES: SMART PERGOLA PREFINISHED ALUMINUM BEAM. SMART PERGOLA PREFINISHED ALUMINUM ROOF LOUVER. CEILING FAN. SEE FINISH SCHEDULE. INFRARED ELECTRIC HEATER. SMART PERGOLA PREFINISHED ALUMINUM GUTTER. RECESSED DOWN LIGHTS. SMART PERGOLA PREFINISHED ALUMINUM 5-1/2" ALUM. SPACER. SMART PERGOLA PREFINISHED ALUMINUM EXTRUSION / WIREWAY. NEW EXIT LIGHT. EXISTING AWNING WITH NEW FABRIC AND GRAPHICS. EXISTING ENTRY CANOPY WITH NEW FABRIC AND GRAPHICS. EXISTING INTERNALLY LIT BLADE SIGN.CEILING FAN WITH NEW PAINT FINISH AND GRAPHICS. EXISTING CORNICE ABOVE. EXISTING GYPSUM BOARD CEILING. EXISTING SUSPENDED ACOUSTICAL PANEL CEILING. EXISTING ERV DUCTWORK. EXISTING RECESSED DOWNLIGHTS. EXISTING EXIT LIGHT. EXISTING KITCHEN EXHAUST DISCHARGE LOUVER EXISTING KITCHEN EXHAUST INTAKE LOUVER EXISTING KITCHEN EXHAUST HOOD EXISTING FAN COIL UNIT ABOVE CEILING NEW ERV UNIT ABOVE CEILING ERV UNIT ACCESS DOOR EXISTING KITCHEN EXHAUST UNIT ACCESS PANEL RCP1 RCP2 RCP3 RCP4 RCP5 RCP6 RCP7 RCP8 RCP9 RCP10 RCP11 RCP12 RCP13 RCP14 RCP15 RCP16 RCP17 RCP18 RCP18B RCP18C RCP19 RCP20 RCP21 RCP22 RCP23 RCP24 RCP25 RCP26 RCP27 RCP28 RCP29 RCP30 RCP31 RCP32 RCP33 RCP34 DESIGN BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR AND ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. MECHANICAL CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. GENERAL CEILING NOTES: LOCATE NEW SMOKE DETECTORS DUE TO NEW LIGHT FIXTURE LAYOUT. INFORM ARCHITECT AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. 6. 5. 4. 1. 2. 3. ELECTRICAL CONTRACTOR AND ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS AND ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CEILING HEIGHT IS INDICATED BY BENCHMARK UNLESS NOTED OTHERWISE.7. HVAC UNITS ARE TO REMAIN IN THEIR CURRENT LOCATIONS. PROVIDE ACCESS PANEL IN DRYWALL CEILINGS IF NEEDED. SUBMIT PLAN FOR LOCATION OF ACCESS PANELS. 8. SUBMIT PLAN FOR LOCATION OF CONTROL JOINTS IN THE DRYWALL CEILING.9. REFLECTED CEILING LEGEND: NEW DOWN LIGHT SUPPLIED BY SMART PERGOLAN F CEILING FAN TO BE: HINKLEY 901`952FMB-NWD TROPIC AIR 52" Matt Black with KOA Blades NEW EXIT LIGHT TO BE: XXX. SCALE: 1/4" = 1'-0"1 Reflected Ceiling Plan 0 2'4'8'