Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
G100 - TITLE SHEET
OWNER HUSE CULINARY 220 ELMWOOD AVE INDIANAPOLIS, IN 46203 PHONE:(317) 637-1811 CONTACT:CHRIS CLIFFORD E-MAIL:CClifford@huseculinary.com ARCHITECT OF RECORD SHEA 10 SOUTH EIGHTH STREET MINNEAPOLIS, MN 55402 PHONE:(612) 339-2257 CONTACT 1:KATE LASZEWSKI E-MAIL: Kate.Laszewski@sheadesign.com CONTACT 2:MARA WESTERHAUS E-MAIL:Mara.Westerhaus@sheadesign.com CONTRACTOR STRUCTURAL ENGINEER M.E.P. ENGINEER FOOD SERVICE CAPITOL CONSTRUCTION SERVICES, INC. 11051 VILLAGE SQUARE LANE FISHERS, IN 46038 PHONE:(317) 288-6436 CONTACT:BRADY MILLER E-MAIL:bmiller@capitolconstruct.com KBSO CONSULTING 275 VETERANS WAY, SUITE 300 CARMEL, IN 46032 PHONE:(317) 344-8045 CONTACT:CHRIS EHLERS E-MAIL:cehlers@kbsoconsulting.com C&T DESIGN AND EQUIPMENT CO., INC 2750 TOBEY DRIVE INDIANAPOLIS, IN 46219 PHONE:(317) 374-2811 CONTACT:RYAN PICKERING E-MAIL:rpickering@c-tdesign.com McCOMAS O'DONNELL & NACCARATO THREE PARKWOOD CROSSING 450 EAST 96TH STREET, SUITE 175 INDIANAPOLIS, IN 46240 PHONE:(317) 580-0402 CONTACT:BRIAN W. STARRETT E-MAIL:bstarrett@o-n.com PROJECT TEAM AV AV DESIGNERS 8742 ROBBINS ROAD INDIANAPOLIS, IN 46268 PHONE:(317) 876-3753 CONTACT:JOE MONFORT E-MAIL:joem@avdesigners.com CABLING/CAMERAS/SECURITY VENDOR DNA INTEGRATORS 8829 SARGENT ROAD INDIANAPOLIS, IN 46256 PHONE:(317) 502-8950 CONTACT:DAN NELSON E-MAIL:dnaintegrators@gmail.com Name Elevation _____(SIM) XXX X ALIGN ROOM NAME XXX 150 SF101 1i 1A3 1 1 1 ?t PT-12 BS-13 CPT-14 ACT-11 BS-1 (EXST) DENOTES EXTENT OF FLOOR MATERIAL DENOTES EXTENT OF FLOOR MATERIAL 1 = CEILING FINISH TYPE 2 = WALL FINISH TYPE 3 = BASE FINISH TYPE 4 = FLOOR FINISH TYPE DENOTES FINISH REFERENCE SYMBOL (SEE FINISH PLAN) NOTE: SEE PROJECT MANUAL FOR ADDITIONAL INFORMATION. DENOTES FURNITURE TYPE (SEE FURNITURE SCHEDULE) DENOTES ELEVATION REFERENCE SYMBOL (SEE ELEVATIONS) _____(SIM) XXX X _____(SIM) XXX X _____(SIM) XXX X DENOTES SECTION/ DETAIL REFERENCE SYMBOL (SEE DETAILS AND SECTIONS) DENOTES DETAIL REFERENCE SYMBOL (SEE DRAWINGS) DENOTES DETAIL AND ENLARGED PLAN REFERENCE SYMBOL (SEE DETAILS AND ENLARGED PLANS) DENOTES REVISION DELTA REFERENCE SYMBOL (SEE DRAWINGS) DENOTES WINDOW TYPE REFERENCE SYMBOL (SEE DRAWINGS) DENOTES DEMOLITION PLAN KEY NOTE REFERENCE SYMBOL (SEE DEMOLITION PLAN) DENOTES PLAN KEY NOTE REFERENCE SYMBOL (SEE PLANS) DENOTES TO ALIGN FACE OF OBJECTS (SEE DRAWINGS) DENOTES ELEVATION REFERENCE SYMBOL (SEE INTERIOR ELEVATIONS) DENOTES PARTITION TYPE (SEE PARTITION SHEET FOR TYPES) DENOTES ROOM NAME AND NUMBER DENOTES AREA NOT IN CONTRACT DASHED LINES DENOTE EXISTING CONSTRUCTION TO BE REMOVED INCLUDING: PARTITIONS, DOORS, FRAMES, HARDWARE, ELECTRICAL, CABINETS, GLAZING AND FRAMES, ETC. DENOTES DOOR NUMBER (SEE DOOR SCHEDULE FOR TYPE AND DETAILS) DENOTES NEW DOOR AND FRAME (SEE DOOR SCHEDULE FOR TYPE AND DETAILS) NEW PARTIAL HEIGHT WALL CONSTRUCTION (SEE PARTITION SHEET FOR TYPES) NEW WALL CONSTRUCTION (SEE PARTITION SHEET FOR TYPES) DENOTES EXISTING DOOR TO REMAIN SHADED AREAS DENOTE EXISTING CONSTRUCTION AND STRUCTURAL ELEMENTS TO REMAIN, PATCH AND REPAIR SURFACES AFFECTED BY DEMOLITION AS REQUIRED FOR NEW FINISHES CPT-2CPT-1 PROJECT SYMBOLS #DENOTES ADD ALTERNATE / DEDUCTS SYMBOL (SEE DRAWINGS) AREA: 7,849 SF SQFT: INTERIOR AREA: 1,861 SF SQFT: EXTERIOR SITE MAP PROJECT LOCATION SITE NORTH A.F.F.ABOVE FINISHED FLOOR AC.ACOUSTICAL AC.T.ACOUSTICAL TILE ADJ.ADJACENT ADJT.ADJUSTABLE A/C AIR CONDITIONING ALT.ALTERNATE ALUM.ALUMINUM A.B.ANCHOR BOLT ANOD.ANODIZED APPROX.APPROXIMATE ARCH.ARCHITECT (URAL) AUTO.AUTOMATIC BSMT.BASEMENT BM.BEAM BRG.BEARING BET.BETWEEN B.L.BUILDING LINE BLK.BLOCK BLKG.BLOCKING BD.BOARD BOT.BOTTOM BLDG.BUILDING B.U.R.BUILT UP ROOFING CAB.CABINET CPT.CARPET (ED) C.I.CAST IRON C.I.F.CAST IN FIELD CLG.CEILING CLG.HT.CEILING HEIGHT CEM.CEMENT CTR.CENTER C.T.CERAMIC TILE CLR.CLEAR (ANCE) CLO.CLOSET COL.COLUMN CONC.CONCRETE (CAST IN PLACE) C.M.U.CONCRETE MASONRY UNIT CONST.CONSTRUCTION CONST.JT.CONSTRUCTION JOINT CONT.CONTINUOUS/CONTINUE C.J.CONTROL JOINT C.G.CORNER GUARD CORR.CORRIDOR C.W.COLD WATER/CURTAIN WALL D.DEEP/DEPTH DET.DETAIL DIAG.DIAGONAL DIA.DIAMETER DIF.DIFFUSER DIM.DIMENSION DISP.DISPENSER DR.DOOR DWR.DRAWER DWG.DRAWING E.EAST ELEC.ELECTRIC (AL) E.W.C.ELECTRIC WATER COOLER EL.ELEVATION ELEV.ELEVATION EMER.EMERGENCY ENC.ENCLOSE (URE) EQ.EQUAL EQUIP.EQUIPMENT EXH.EXHAUST EXIST.EXISTING EXP.JT.EXPANSION JOINT EXP.EXPOSED EXT.EXTERIOR F.R.P.FIBERGLASS REINFORCED PANEL FIN.FINISH (ED) F.A.FIRE ALARM F.H.S.FIRE HOSE STATION FP.FIREPROOFING F.P.S.C.FIRE-PROOF-SELF-CLOSING F.R.T.FIRE RETARDANT TREATED F.R.FIRE-RESISTANT FLR.FLOOR (ING) F.D.FLOOR DRAIN FLUOR.FLUORESCENT FT.FOOT FTG.FOOTING FND.FOUNDATION F.A.I.FRESH AIR INTAKE F.S.FULL SIZE FURR.FURRED (ING) FUT.FUTURE GA.GAGE, GLAZING GALV.GALVANIZED GL.GLASS, GLAZING GL.BLK.GLASS BLOCK G.T.GRANITE TILE G.GRANITE GYP.BD.GYPSUM WALLBOARD G.W.B.GYPSUM WALLBOARD HBD.HARDBOARD HDW.HARDWARE HDWD.HARDWOOD HDR.HEADER H.O.HIGH OUTPUT HTG.HEATING H.V.A.C.HEATING/VENTILATION/AIR COND. HT.HEIGHT H.HIGH H.P.HIGH POINT H.C.HOLLOW CORE H.M.HOLLOW METAL HORIZ.HORIZONTAL H.B.HOSE BIBB H.W.HOT WATER HR.HOUR HYD.HYDRANT IN.INCH INCL.INCLUDE (D) (ING) I.D.INSIDE DIAMETER INSUL.INSULATE (D) (ION) INT.INTERIOR JAN.JANITOR JT.JOINT KIT.KITCHEN K.O.KNOCK OUT LBL.LABEL LAB.LABORATORY LAD.LADDER LAM.LAMINATE (D) LAV.LAVATORY L.H.LEFT HAND L.LENGTH LT.LIGHT LT.WT.LIGHTWEIGHT LIN.LINEAR LVR.LOUVER L.P.LOW POINT MFR.MANUFACTURE (R) MATL.MATERIAL (S) MAX.MAXIMUM MECH.MECHANIC (AL) MED.MEDIUM MEMB.MEMBRANE MTL.METAL MEZZ.MEZZANINE MIN.MINIMUM MIR.MIRROR MISC.MISCELLANEOUS MLD.MOLDING, MOULDING M.R.MOISTURE RESISTANT MT.MOUNT (ED) (ING) MOV.MOVABLE MULL.MULLION NAT.NATURAL NOM.NOMINAL N.NORTH N.I.C.NOT IN CONTRACT N.T.S.NOT TO SCALE NO.NUMBER OFF.OFFICE O.C.ON CENTER (S) OPG.OPENING OPP.OPPOSITE O.D.OUTSIDE DIAMETER O.A.OVERALL PARQ.PARQUET FLOORING PTD.PAINT (ED) PNL.PANEL P.BD.PARTICLE BOARD PTN.PARTITION PERF.PERFORATE (D) P.PERSON (S) PLAS.PLASTER P.LAM.PLASTIC LAMINATE PL.PLATE PLGL.PLATE GLASS PLMG.PLUMBING PWD.PLYWOOD PT.POINT PVC.POLYVINYL CHLORIDE P.S.F.POUNDS PER SQUARE FOOT P.S.I.POUNDS PER SQUARE INCH P.L.PROPERTY LINE Q.T.QUARRY TILE RAD.RADIUS RECP.RECEPTACLE REF.REFERENCE REG.REGISTER REINF.REINFORCE (D) (ING) RESIL.RESILIENT RET.RETURN R.A.RETURN AIR REV.REVISION (S), REVISED RM.ROOM R.O.ROUGH OPENING SCH.SCHEDULE SEC.SECOND, SECTION SHT.SHEET SIM.SIMILAR S.C.SOLID CORE S.SOUTH SPK.SPEAKER SPEC.SPECIFICATION (S) SQ.SQUARE S.Y.SQUARE YARD S.S.STAINLESS STEEL STD.STANDARD STL.STEEL STOR.STORAGE S.D.STORM DRAIN STRUCT.STRUCTURAL SUSP.SUSPENDED SYM.SYMMETRY (ICAL) SYS.SYSTEM TEL.TELEVISION TEMP.TEMPERED TERR.TERRAZZO THK.THICK (NESS) THRES.THRESHOLD TOL.TOLERANCE T&G.TONGUE AND GROOVE T.O.C.TOP OF CURB T.O.S.TOP OF SLAB T.O.STL.TOP OF STEEL T.O.W.TOP OF WALL T.TREAD TX.TRANSFORMER TYP.TYPICAL UNF.UNFINISHED U.O.N.UNLESS OTHERWISE NOTED V.B.VAPOR BARRIER VAR.VARIES, VARNISH VNR.VENEER VERT.VERTICAL VEST.VESTIBULE V.VINYL V.C.T.VINYL COMPOSITION TILE V.I.F.VERIFY IN FIELD W.T.W.WALL TO WALL W.C.WATER CLOSET WP.WATERPROOFING WS.WEATHER STRIPPING WT.WEIGHT W.W.F.WELDED WIRE FABRIC W.WEST, WIDE, WIDTH W/WITH WDW.WINDOW W.GL.WIRED GLASS W/O WITHOUT WD.WOOD W.P.WORKING POINT ABBREVIATIONS GENERAL PROJECT NOTES 1. AIA DOCUMENTS A201 AND A101 SHALL BE PART OF THE CONTRACT DOCUMENTS. 2. ALL WORK SHALL COMPLY WITH APPLICABLE FEDERAL, LOCAL AND MUNICIPAL BUILDING AND ZONING CODES, AS WELL AS ANY AND ALL REGULATORY AGENCIES, INCLUDING, BUT NOT LIMITED TO, ANSI, OSHA, ETC. GENERAL NOTES SHALL APPLY TO ALL DRAWINGS. 3. THE TERMS "CONSTRUCTION CONTRACTOR," "GENERAL CONTRACTOR, G.C., CONSTRUCTION MANAGER/MANAGEMENT" AND "CONTRACTOR" SHALL BE UNDERSTOOD TO BE THE SAME UNLESS SPECIFICALLY NOTED OTHERWISE. 4. G.C. SHALL PROVIDE ALL THE DRAWINGS, COMPLETED PAPERWORK AND CERTIFICATES OF INSPECTION AND SHALL PERFORM ALL THE CONTROLLED INSPECTIONS AS REQUIRED FOR BUILDING DEPARTMENT SIGN OFF. 5. THE ARCHITECT AND THE OWNER RESERVES THE RIGHT TO ALLOW OTHER CONTRACTS TO PERFORM WORK IN CONNECTION WITH THE PROJECT. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF WORK AND ESTABLISHING SCHEDULES FOR ALL TRADES; THEY SHALL AFFORD OTHER CONTRACTORS REASONABLE OPPORTUNITY FOR THE INTRODUCTION AND STORAGE OF THEIR MATERIALS AND EQUIPMENT AND THE EXECUTION OF THEIR WORK. 6. DRAWINGS ARE NOT TO BE SCALED; DIMENSIONS GOVERN. 7. ALL WORK IS TO CONFORM TO THE CONTRACT DOCUMENTS AND SHALL BE NEW AND OF THE BEST QUALITY OF THE KINDS SPECIFIED. 8. ALL MATERIALS AND EQUIPMENT SPECIFIED SHALL BE SUPPLIED, INSTALLED, CONNECTED, ERECTED, CLEANED, AND CONDITIONED AS DIRECTED BY THE SUPPLIER/MANUFACTURER, IN ACCORDANCE WITH ACCEPTED INDUSTRY STANDARD PRACTICE AND IN COMPLIANCE WITH PRODUCT WARRANTY. 9. THE CONTRACTOR SHALL IN ALL RESPECTS COMPLY WITH ALL REGULATIONS OF THE BUILDING MANAGEMENT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN SUCH REGULATIONS FROM THE BUILDING OWNER. IN THE EVENT OF CONFLICT BETWEEN BUILDING REGULATIONS AND OTHER CONTRACT DOCUMENTS, THE ARCHITECT SHALL BE CONSULTED PRIOR TO PROCEEDING. 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ARRANGING WITH BUILDING MANAGEMENT THE USE OF ELEVATOR OR OTHER HOISTING FACILITIES FOR HANDLING THE DELIVERY OF MATERIALS. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING ALL SUB-TRADES OF CONDITIONS REGARDING ELEVATOR CAB SIZE, DOOR OPENING WIDTHS AND LOADING WEIGHT CAPACITIES. 11. ALL PUBLIC AREAS SUCH AS ELEVATOR LOBBIES, CORRIDORS, TOILETS, AND SERVICE HALLS SHALL BE PROTECTED TO THE SATISFACTION OF THE BUILDING MANAGEMENT. EQUIPMENT AND OTHER PROPERTY BELONGING TO THE BUILDING SHALL ALSO RECEIVE PROTECTION AND REFURBISHING IF DAMAGED IN THE COURSE OF CONSTRUCTION, MUST BE REPAIRED TO THE SATISFACTION OF BUILDING MANAGEMENT. 12. CONSTRUCTION PERSONNEL MUST CARRY PROPER IDENTIFICATION AT ALL TIMES. 13. ALL CONSTRUCTION TOOLS AND EQUIPMENT SHALL MEET REQUIREMENTS OF OSHA AND ALL APPLICABLE REGULATORY AGENCIES. 14. GENERAL CONTRACTOR IS RESPONSIBLE TO PROTECT, AS REQUIRED, ALL TENANT OCCUPIED AREAS WHERE FINISH WORK OR GENERAL CONSTRUCTION IS TO BE PERFORMED. GENERAL CONTRACTOR TO INSTALL ADEQUATE PROTECTION OF BUILDING PAPER, MASONITE, OR OTHER APPROVED MATERIAL ON ALL FINISHED SURFACES AS DIRECTED BY THE ARCHITECT PRIOR TO THE OWNER'S MOVING DATE, AND SHALL REMOVE SAME FOLLOWING COMPLETION OF THE MOVE 15. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL COSTS INCURRED FOR DAMAGES CAUSED BY THEIR SUBCONTRACTORS. 16. ALL WORK SHALL CONFORM WITH THE REQUIREMENTS OF APPLICABLE CODES: RULES AND REGULATIONS ALL IN THEIR LATEST EDITION OF ALL AUTHORITIES HAVING JURISDICTION OVER WORK OF THIS TYPE, INCLUDING THE RULES AND REGULATIONS OF THE BUILDING MANAGEMENT. 17. SELECTION OF SUBCONTRACTORS IS SUBJECT TO THE OWNER'S REVIEW PRIOR TO AWARDING OF CONTRACT. THE GENERAL CONTRACTOR MUST SUBMIT A LIST OF THEIR PROPOSED SUBCONTRACTORS WITH THE SUBMISSION OF THIS BID, AS WELL AS EVIDENCE THAT THOSE SUBCONTRACTORS REQUESTED TO BE AFFORDED THE OPPORTUNITY TO BID HAVE HAD THAT OPPORTUNITY AND HAVE RESPONDED. 18. ALL WORK, COMPLETED OR OTHERWISE, SHALL BE PROPERLY PROTECTED AT ALL TIMES. CONTRACTOR SHALL FOLLOW ALL ACCEPTED METHODS OF SAFETY PRACTICE AND PROVIDE ALL FENCES, BARRICADES, ETC., AS MAY BE NEEDED TO PROTECT LIFE AND PROPERTY AND AS MAY BE REQUIRED BY AUTHORITIES HAVING JURISDICTION OVER THIS WORK. THEY SHALL REPAIR, AT THEIR OWN COST, ANY DAMAGES TO THE PREMISES OR ADJACENT WORK CAUSED BY THEIR OPERATION. 19. BEFORE COMMENCING WITH ANY WORK, THE CONTRACTOR SHALL FILE WITH THE OWNER AND/OR BUILDING MANAGEMENT CURRENT INSURANCE CERTIFICATES IN THE AMOUNTS REQUESTED BY THE OWNER AND/OR BUILDING MANAGEMENT FOR WORKER'S COMPREHENSIVE GENERAL LIABILITY, BODILY INJURY AND PROPERTY DAMAGE. THE OWNER AND/OR BUILDING MANAGEMENT SHALL BE NAMED "ADDITIONAL INSURED" ON ALL CERTIFICATES OF INSURANCE, INCLUDING THE ARCHITECT. 20. THE CONTRACTOR SHALL GUARANTEE IN WRITTEN FORM, AS ACCEPTABLE TO THE OWNER, ALL LABOR AND MATERIALS INSTALLED BY THEM FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR AFTER DATE OF ACCEPTANCE OF THE WORK BY THE OWNER EXCEPT AS MODIFIED HEREIN OR ON OTHER DRAWINGS. SHOULD DEFECTS OCCUR, ALL WORK SHALL BE REPLACED OR PROPERLY REPAIRED AT NO ADDITIONAL COST TO THE OWNER. 21. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTAL TO THE AUTHORITY HAVING JURISDICTION ANY AND ALL REVISIONS POST PERMIT APPROVAL REQUIRING REVIEW AND INCORPORATION INTO THE APPROVED CONSTRUCTION DOCUMENTS. 22. STEEL STAIRS ARE A DELEGATED DESIGN TO STEEL FABRICATORS SPECIALTY ENGINEER.DRAWINGS SIGNED & SEALED BY LICENSED STRUCTURAL ENGINEER ARE REQUIRED.REFER TO METAL FABRICATIONS SPECIFICATION. AREA: 740 SF SQFT: INTERIOR SHEET INDEXPROJECT INFORMATION PROJECT MAP or KEY PLAN PROJECT NAME: PROJECT SCOPE: PROJECT ADDRESS: 1933 LOUNGE 175 S RANGELINE RD, SUITE 100 CARMEL, INDIANA 46032 PRICING FOR NEW FOOD AND BEVERAGE RESTAURANT -TENANT IMPROVEMENT OF AN EXISTING SHELL BUILDING SPACE - INTERIOR CONSTRUCTION, MEZZANINE, & PATIO AREA 175 S RANGELINE RD, SUITE 100 CARMEL, INDIANA 46032 1933 LOUNGE DRAWING ISSUE DATA: (FOR CONSTRUCTION) ADDENDUM 2 2024-02-26 DATE ISSUED REG. NO. THIS DOCUMENT IS CERTIFIED BY consultant project title seal project no. sheet title drawn client issue date checked 10 South Eighth Street Minneapolis, MN 55402 t 612_339-2257 sheadesign.com AR00910059 David A. Shea, Architect 2024-02-02 4/26/2024 4:58:09 PMC:\Revit Projects\A22_8764.00-1933 RESTAURANT - CARMEL, IN_AmeliaK-SHEA.rvt8764.00 AK KL/HS/SO TITLE SHEET G100 © 2022 shea, inc. (FOR CONSTRUCTION) ADDENDUM 2 2024-02-26 1ST. ELMO, INC. 101 W. WASHINGTON STREET, SUITE 1250 EAST INDIANAPOLIS, IN 46204 1933 LOUNGE 175 S RANGELINE RD, SUITE 100 CARMEL, INDIANA 46032 SHEETS DRAWINGS 2024.04.26 ADDENDUM 22024.02.26 ADDENDUM 12024.02.02 PERMIT/BID SET2023.08.25 PRICING SETSHT. NO. NAME ■ ■ ■ ■G100 TITLE SHEET ■ ■ ■G200 ACCESSIBLE DETAILS ■ ■ ■ ■G300 LIFE SAFETY PLAN ■G400 FIRE SAFETY PLAN ■A001 SITE PLAN ■ ■ ■ ■A010 OVERALL PLAN ■ ■ ■ ■A110a FLOOR PLAN - PART I ■ ■ ■A110b FLOOR PLAN - PART II ■ ■ ■A111 MEZZANINE PLANS ■ ■ ■A120a CEILING PLAN - PART I ■ ■ ■A120b CEILING PLAN - PART II ■ ■ ■A130a LIGHTING PLAN - PART I ■ ■ ■A130b LIGHTING PLAN - PART II ■ ■ ■A140a FINISH PLAN - PART I ■ ■ ■A140b FINISH PLAN - PART II ■ ■ ■A150a FURNITURE-EQUIPMENT PLAN - PART I ■ ■ ■A150b FURNITURE-EQUIPMENT PLAN - PART II ■ ■ ■A180 ROOF PLAN - OVERALL ■ ■ ■A190 LIGHTING SCHEDULE AND SPECIFICATIONS ■ ■ ■A191 FINISH SCHEDULE AND SPECIFICATIONS ■ ■ ■A192 FINISH SCHEDULE AND SPECIFICATIONS ■ ■ ■ ■A210 EXTERIOR ELEVATIONS ■ ■ ■ ■A211 EXTERIOR ELEVATIONS ■ ■ ■A240 INTERIOR ELEVATIONS ■ ■ ■A241 INTERIOR ELEVATIONS ■ ■ ■A320 WALL SECTIONS ■ ■ ■A321 WALL SECTIONS ■ ■ ■A403 ENLARGED MEZZANINE ELEVATIONS & DETAILS ■ ■ ■A404 ENLARGED HOST AREA PLAN & DETAILS ■ ■ ■A405 ENLARGED WINE ROOMS PLAN & ELEVATIONS ■ ■ ■A406 ENLARGED WINE ROOMS DETAILS ■ ■ ■A407 ENLARGED WINE ROOMS DETAILS ■ ■ ■A408 ENLARGED DINING ALCOVES PLANS & DETAILS ■ ■ ■A409 ENLARGED BOURBON ROOM PLAN & ELEVATIONS ■ ■ ■A410 ENLARGED BAR PLAN ■ ■ ■A411 ENLARGED BAR ELEVATIONS ■ ■ ■A412 ENLARGED BAR ELEVATIONS ■ ■ ■A413 ENLARGED BAR DETAILS ■ ■ ■A414 ENLARGED BAR DETAILS ■ ■ ■A415 ENLARGED BAR DETAILS ■ ■ ■A416 ENLARGED BAR DETAILS ■ ■ ■A417 ENLARGED BAR DETAILS ■ ■A418 ENLARGED BAR DETAILS ■ ■ ■A420 ENLARGED CEILING/LIGHTING PLANS ■ ■A421 ENLARGED CEILING/LIGHTING PLANS ■ ■ ■A460 ENLARGED RESTROOM PLAN AND DETAILS ■ ■ ■A461 ENLARGED RESTROOM ELEVATIONS ■ ■ ■A540 INTERIOR DETAILS (MISC.) ■ ■ ■A541 INTERIOR DETAILS (STAIRS) ■ ■ ■A542 INTERIOR DETAILS (CEILING) ■ ■ ■A550 SERVER STATION MILLWORK ELEVATIONS & DETAILS ■ ■A551 SERVER STATION MILLWORK ELEVATIONS & DETAILS ■ ■ ■A610 DOOR SCHEDULE, PARTITION TYPES, AND DETAILS ■ ■ ■A615 DOOR & WINDOW DETAILS ■ ■ ■A616 WINDOW-OPENING SCHEDULE AND DETAILS ■S001 GENERAL NOTES & SCHEDULES ■S110 OVERALL FOUNDATION PLAN ■S110a FOUNDATION PLAN - PART 1 ■S110b FOUNDATION PLAN - PART 2 ■S121 MEZZANINE FRAMING PLAN ■S131 WINE STORAGE ROOM PLANS ■S132 WINE STORAGE ROOM SECTIONS ■S141 DINING ALCOVES PLAN, SECTIONS AND DETAILS ■S151 BOURBON ROOM PLANS, SECTIONS AND DETAILS ■S161 ENLARGED BAR PLANS ■S171 FIREPLACE PLAN, SECTIONS AND DETAILS ■S181 OPERABLE PARTITIONS PLANS, SECTIONS AND DETAILS ■S191 EXISTING PARTIAL ROOF FRAMING PLAN, SECTIONS AND DETAILS ■S201 TYPICAL FOUNDATION DETAILS ■S301 FRAMING DETAILS ■S302 FRAMING DETAILS ■ ■ ■M001 SYMBOLS AND ABBREVIATIONS ■ ■ ■M111 MECHANICAL FIRST FLOOR PLAN ■ ■ ■M112 MECHANICAL SECOND FLOOR PLAN ■ ■ ■M113 MECHANICAL THIRD FLOOR PLAN ■ ■ ■M114 MECHANICAL ROOF PLAN ■ ■M301 MECHANICAL SECTIONS ■ ■M302 MECHANICAL SECTIONS ■ ■ ■M511 MECHANICAL DETAILS ■ ■M512 MECHANICAL DETAILS ■ ■ ■M611 MECHANICAL SCHEDULES ■ ■M911 TEMPERATURE CONTROL DIAGRAMS ■ ■ ■MD111 MECHANICAL DEMOLITION FLOOR PLAN ■ ■P001 PLUMBING SYMBOLS AND APPREVIATIONS ■ ■ ■P110 FOUNDATION PLUMBING PLAN ■ ■ ■P111 1ST FLOOR PLUMBING PLAN (ABOVE FLOOR) ■ ■P112 1ST FLOOR PLUMBING PLAN (ABOVE CEILING) ■ ■ ■P114 ROOF PLUMBING PLAN ■ ■ ■P511 PLUMBING DETAILS ■ ■ ■P611 PLUMBING SCHEDULES ■ ■ ■P612 PLUMBING SCHEDULES ■ ■P613 PLUMBING SCHEDULES EXTERIOR 1,861 SF INTERIOR 8,589 SF NORTH 1 ADDE NDUM 1 1 A DDE NDUM 1 no. date issued for 1 2024-02-26 ADDENDUM 1 2 2024-04-26 ADDENDUM 2 SHEETS DRAWINGS 2024.04.26 ADDENDUM 22024.02.26 ADDENDUM 12024.02.02 PERMIT/BID SET2023.08.25 PRICING SETSHT. NO. NAME ■ ■ ■E010 SYMBOLS AND ABBREVIATIONS ■ ■ ■E411 ELECTRICAL ENLARGED PLANS ■ ■E412 HOST ENTRY ENLARGED LIGHTING PLANS & DETAILS ■ ■E413 WINE ROOMS ENLARGED LIGHTING PLANS & DETAILS ■ ■E414 DIING ROOM ENLARGED LIGHTING PLANS & DETAILS ■ ■E415 RESTROOMS ENLARGED LIGHTING PLANS & DETAILS ■ ■E416 BAR ENLARGED LIGHTING PLAN ■ ■E417 BAR ELEVATIONS, SECTIONS & DETAILS ■ ■E418 BAR ELEVATIONS, SECTIONS & DETAILS ■ ■ ■E511 ELECTRICAL DETAILS ■ ■ ■E512 ELECTRICAL DETAILS ■ ■ ■E611 ELECTRICAL SCHEDULES ■ ■ ■E612 ELECTRICAL SCHEDULES ■ ■ ■E911 ELECTRICAL DIAGRAMS ■ ■ ■EL110 LEVEL 1 LIGHTING PLAN - PART I ■ ■ ■EL111 LEVEL 1 LIGHTING PLAN - PART II ■ ■ ■EL112 MEZZANINE LIGHTING PLAN ■ ■ ■EP111 ELECTRICAL FIRST FLOOR PLAN ■ ■ ■EP112 ELECTRICAL MEZZANINE PLAN ■ ■EP113 ROOF ELECTRICAL PLAN ■ ■ ■ES111 ELECTRICAL SITE PLAN ■CA001 CAPTIVE AIRE SHEET #1 ■CA002 CAPTIVE AIRE SHEET #2 ■CA003 CAPTIVE AIRE SHEET #3 ■CA004 CAPTIVE AIRE SHEET #4 ■CA005 CAPTIVE AIRE SHEET #5 ■CA006 CAPTIVE AIRE SHEET #6 ■CA007 CAPTIVE AIRE SHEET #7 ■CA008 CAPTIVE AIRE SHEET #8 ■CA009 CAPTIVE AIRE SHEET #9 ■CA010 CAPTIVE AIRE SHEET #10 ■CA011 CAPTIVE AIRE SHEET #11 ■CA012 CAPTIVE AIRE SHEET #12 ■CA013 CAPTIVE AIRE SHEET #13 ■CA014 CAPTIVE AIRE SHEET #14 ■CA015 CAPTIVE AIRE SHEET #15 ■CA016 CAPTIVE AIRE SHEET #16 ■CA017 CAPTIVE AIRE SHEET #17 ■CA018 CAPTIVE AIRE SHEET #18 ■CA019 CAPTIVE AIRE SHEET #19 ■CA020 CAPTIVE AIRE SHEET #20 ■CA021 CAPTIVE AIRE SHEET #21 ■CA022 CAPTIVE AIRE SHEET #22 ■CA023 CAPTIVE AIRE SHEET #23 ■CA024 CAPTIVE AIRE SHEET #24 ■ ■ ■E1-K1.0 KITCHEN EQUIPMENT PLAN ■ ■E1-K1.1 UTILITY SCHEDULES ■ ■ ■E1-K2.0 ELECTRICAL ROUGH-IN PLAN ■ ■ ■E1-K3.0 PLUMBING ROUGH-IN PLAN ■ ■ ■E1-K4.0 SPECIAL CONDITIONS PLAN ■ ■E1-K5.0 ELEVATIONS ■ ■E1-K5.1 ELEVATIONS - MAIN BAR 2 ADDE NDUM 2