HomeMy WebLinkAboutA180 - ROOF PLAN - OVERALL1 1.2 1.6 2 2.4 2.8 3 E F G H J K LSLOPE1/4"/12"SLOPE1/4"/12"SHELL BUILDING CIRCULATION 1933 LOUNGESLOPE1/4"/12"SLOPE1/4"/12"SLOPE1/4"/12"SLOPE1/4"/12"PART I PART II 4 A180 _____ 3 A180 _____ 2 A180 _____ 1 1 1 1 3 A180 _____ SHELL BUILDING ROOF, SEE SHELL BUILDING DRAWINGS FOR MORE INFORMATION SHELL BUILDING ROOF, SEE SHELL BUILDING DRAWINGS FOR MORE INFORMATION ROOF DRAIN & OVERFLOW ROOF DRAIN & OVERFLOW ROOF ACCESS AT OTHER END OF THE ROOF, SEE SHELL BUILDING ROOF DRAWINGS FOR MORE INFORMATION SLOPED METAL ROOF PARAPET, SEE SHELL BUILDING DRAWINGS FOR MORE INFORMATION 1 1 1 1 ROOF PLAN NOTES 1. GENERAL CONTRACTOR TO INSTALL AND SEAL ROOF PENETRATIONS, CURBS AND SLEEPERS. 2. HVAC VENDOR TO PROVIDE ROOF CURBS AND VENDOR IS RESPONSIBLE FOR PROVISION/ COORDINATION OF ROOF PENETRATIONS REQUIRED FOR EQUIPMENT INSTALLATION. 3. JOIST MANUFACTURER TO VERIFY STRUCTURAL JOIST CAPACITY BASED UPON FINAL ROOF TOP MOUNTED MECHANICAL PLAN AND WEIGHTS SUPPLIED BY MECHANICAL ENGINEER. 4. FLASH ROOF VENT PIPES. 5. APPROXIMATE LOCATION OF SATELLITE DISH PROVIDED BY AV CONTRACTOR. COORDINATE WITH JOIST MANUFACTURER. G.C. TO PROVIDE 4x4 WD SLEEPERS AT ALL CONDENSING UNITS AND SATELLITE DISH LOCATION. 6. INSTALL ROOF TOP MOUNTED MECHANICAL UNITS ON PREFINISHED METAL CURB WITH TREATED WOOD NAILER. REFER TO DETAILS AS INDICATED ON THIS SHEET. SEE MECHANICAL DRAWINGS FOR NUMBER, SIZE, HEIGHT, WEIGHT, AND FINAL LOCATION OF ROOF TOP MOUNTED MECHANICAL EQUIPMENT. 7. VENT PIPES TO BE 10"-0" MINIMUM FROM AIR INTAKE. 8. NEW ROOF MEMBRANE TO BE INSTALLED BY MANUFACTURER APPROVED LICENSED ROOFING CONTRACTOR. REFER TO DETAILS AS INDICATED ON THIS SHEET. SPECIFICATIONS FOR NEW ROOF CRICKETS PER MANUFACTURER'S RECOMMENDATIONS. 9. GAS PIPING TO ROOF SHALL BE PAINTED TO MATCH ADJACENT FINISH. PAINT GAS PIPING ON THE ROOF (SAFETY YELLOW) 10. G.C. TO PROVIDE POWER AND BLOCKING FOR ALL BUILDING SIGNAGE. COORDINATE WITH SIGN VENDOR. G.C. TO PROVIDE POWER TO DESIGNATED TRANSFORMER LOCATIONS FOR LED STRIP LIGHTING SYSTEM -SEE M.E.P. DRAWINGS AND COORDINATE FINAL LOCATION WITH SIGN VENDOR 11. PROVIDE 4" CANT STRIP AT INTERSECTION OF ROOF AND PARAPET WALLS, TYP. ROOF PLAN SYMBOLS SYMBOL DESCRIPTION ROOF DRAIN WITH OVERFLOW ROOF DRAIN ROOF DRAIN SCUPPER AND DOWNSPOUT OVERFLOW SCUPPER MEMBRANE WALKWAY TO ALL SERVICE SIDES OF ROOF TOP MOUNTED EQUIPMENT. VERIFY LOCATION PRIOR TO INSTALLATION. WALKWAY PADS SHALL BE PURCHASED WITH PVC ROOFING MEMBRANE, INSTALLED AND LOCATED PER MANUFACTURER'S SPECIFICATIONS AND WARRANTY. COLOR OF WALKWAY TO CONTRAST ROOF COLOR SPOT ELEVATIONS INDICATE ROOF INSULATION DEPTH. 2" MIN. INSULATION DEPTH AT LOW POINT. DENOTES DIRECTION OF SLOPE. SHALL BE 1/4" PER FT. MIN. 2" HATCH DENOTES TAPERED INSULATION CLAMP DETAIL, SEE PREMOLDED PIPE SLEEVE WELD TO ROOF MEMBRANE TYP.8"2"EXISTING ROOF ASSEMBLY MECH. EQUIP. SEE MECH DWGS. SECURE TO CURB W/ GASKETED SCREWS EXTENDED ROOF MEMBRANE AND WRAP CURB PREFAB HEAVY GAUGE GALVANIZED STEEL CURB W/ RIGID INSULATION DOWN TO METAL DECK CANT STRIP AT ALL CURB EDGES ROOFING MEMBRANE OVERLAP AS REQ'D BUILT-UP ROOF SYSTEM 1/2"6"2"X2"X1/4" ANGLE BAR 2"X2"X1/4" SQUARE BAR 1/4" THICK STEEL PLATE MOUNTED TO EXISTING ROOF DECK EXISTING ROOFING MEMBRANE EXISTING ROOF CURB DATE ISSUED REG. NO. THIS DOCUMENT IS CERTIFIED BY consultant project title seal project no. sheet title drawn client issue date checked 10 South Eighth Street Minneapolis, MN 55402 t 612_339-2257 sheadesign.com AR00910059 David A. Shea, Architect 2024-02-02 2/26/2024 5:58:07 PMC:\Revit Projects\A22_8764.00-1933 RESTAURANT - CARMEL, IN_AmeliaK-SHEA.rvt8764.00 AK KL/HS/SO ROOF PLAN -OVERALL A180 © 2022 shea, inc. (FOR CONSTRUCTION) ADDENDUM 1 2024-02-26 1ST. ELMO, INC. 101 W. WASHINGTON STREET, SUITE 1250 EAST INDIANAPOLIS, IN 46204 1933 LOUNGE 175 S RANGELINE RD, SUITE 100 CARMEL, INDIANA 46032 (NOT ALL KEYNOTES MAY BE USED ON THIS SHEET) ROOF KEY NOTES NO.DESCRIPTION REV. 1 ROOFTOP UNIT - SEE MECHANICAL DRAWINGS FOR MORE INFORMATION SCALE: 3/16" = 1'-0"A180 1 ROOF PLAN - PART I PROJECT NORTH SCALE: 1 1/2" = 1'-0"A180 2 VENT PIPE SLEEVE DETAIL SCALE: 3" = 1'-0"A180 3 EQUIPMENT CURB ROOF DETAIL SCALE: 3" = 1'-0"A180 4 CONDENSING UNIT SUPPORT no. date issued for