HomeMy WebLinkAbout07020092 Site Plan
~..,
Schneider
The SchneJd.er Corporation
6901 otiJ Avenue
HIstoric Fort., H8rr1Bon
Indlanapolls, Indlana 1112l6-l037
817-826-7100
817-826-7200 fAX
Enalnoorlng
SunoylDg
Landscape An>hltooluro
GIS .IJB
GooloO'
This Plot Plan Prepared For.
Trinlty/Beazer Home8
Lot # 26 , containing 6,335 SJ.:!:, in
Yorktown Woods
Section # 1
Instrument # 200600017282
C.O.C. # 200600023419
P.C. # 4, Slide # 48
Hamilton County, Clay Township
Section 19, Township 18 N, Range 4 EAST
2592 Highmount Court (50' R/wl
Carmel, IN 46074
Prepared Date: 01-03-07 : By. MBK
Community Restrictions:
Side Yard = 6' (BH)
Rear Yard = 20'
Zoning = ROSO III
Finished Floor Eievation information
Pod Grode = 824.7 per plan
Pod Grade + 0.33' = Garage FFE (825.03)
Garage FFE + 1.04' = Residential FFE (826.07)
Residential FFE - 10.0' = Basement FFE (816.07)
Oriveway Slope = 6.2~
Note: The garage finished fioor elevation
Is 3.1' above the curb at the drive, per
plan.
Ground Cover Calculations:
Drive =1,053SF:!:
Public Walk = 233 SF:!:
Private Walk = 6 SF:!:
Rear Yard = 1,394 SF:!:
Sod = 200 SY:!: , from rear of home.
NOTE:
IN THE RESIDENTIAL DISTlRICTS UMITlNG
HEIGHT TO TWENTY-FIVE (25) FEET, A
DWELLING MAYBE INCREASED IN HEIGHT
TD THIRTY-FIVE (35) FEET PROV1DED
THE SIDE AND REAR YARDS ARE
INCREASED AN ADDITlONAL FOOT FOR
EACH FOOT SUCH STlRUCTURE EXCEEDS
TWENTY-FIVE (25) FEET IN HEIGHT.
PER CARMEL ZONING ORDINANCE 26.1.1.
FLOOD HAZARD STATEMENT
CERTIFICATION
Plot Pion legend
[@]J Proposed Grades
000.0 Existing Grod..
__ 000.0- Contour Grade
* Approx. lateral locotion
- . - Sanitary Sewer Unes
-1'1'- Storm Sewer Unes
- '" - Water Service l1nes
- - - - - - - Sub-Surface Oroln Un..
e Monhole (Sanltory or Storm)
. Beehlie Inlet (Storm)
l1li Curb Inlet (Storm)
o End Section (Storm)
A Fire H)<Iront
- 000 - 0.. _ Flow Una of awele
Note: Sanitary Sewer
Top of Costing Information
Upstream Manhole, TC= 822.69
Downstream Manhole, TC=824.65
Per As-Built
Note: The contractor Is to maintain
a minimum distance of ten feet (10')
between the sanitary sewer and
water line laterals.
~
TYPICAL SWALE SECTION
,\\\\\\IIIIIIII/II/II/i///
~~\\\ L 1'1i~
if- 'S ,Cp ~
if- ~, ,,"""', t(h~
$ (.~,""'G\S Te~'~""", A%
i ~~...~~ SON3003'O ....~\
% \. STATE OF ..... ~
'\ <"';;.....f./vOJ A~ ~......~#
~-f#; '''''''''''''C\'' ~
~0//, SUR~ \.~~#
7/////11/1I1I11111\\\\\\\\~
~l.r-v
This drawing is not intended to be represented os 0 retracement or
original boundary survey, a route survey, or a Surveyor Location Report.
Flood Hazard Statement: The accuracy of any flood hazard data shown on
this plot plan is subject to mop scale uncertainty and to any other
uncertainty in location or elevation on the referenced flood insurance rate
mote (FIRM). None of the within described land lies within that special fiood
hazard zone "A", os said land plots by scale on Community Mop Panel #
18057C 0026 F of the fiaod insurance rote mops (FIRM) for the city of
Carmel, Hamilton County, indiana, Doted February 19, 2003.
-',
"''''
"
~').\~t
'~'/V".
Note:
This drawing is based on construction plans or record drawings,
and is not based upon 0 Reid survey. The Schneider Corporation
does not warrant the accuracy or sufficiency of this Information.
Contractors shauid verify existing conditions prior to any
construction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation immediately; fa1l1ng to do
so results in the contractors assumption of all liability.
Note: '
The basement elevation, depicted hereon, has been deterh,lned and
based on the pad grades and/or contours taken from th~
construction plans for this subdivision. Unless stated, no
Informotlon about fluctuating water tables, soH conditions, or soli
types hos been provided or stated on said plans. This lot Is
located neor (I body of water. Lot or soli conditIons may require
that the basement floor elevation be heid 2 foot above normol pool
elevation. Site Investigation may be needed If water Is encountered
during the excavation process or If other known water elevtltlon or
sons conditIons are present. Investlgotlon and any remedl91 ,_
procedures Is ot th"e discretion-of the blillder-to deteiTiilne -and
toke appropriate steps of octlon. If any ground water Is
encountered during excavation the builder Is encouraged to contact
The Schneider Corporation to discuss possible courses of action.
Note: Sump pump(s) to be
placed by builder os needed.
LOT # 26
VB # 06.0065390
CAUTIONI!
The home location shown hereon has minimal tolerance
for placement error, therefor it Is recommended that
the builder hove the foundation pinned after the footing
is poured to ensure that the improvements do not
encroach upon setback lines or easements.
OetoD of t)!llcal Groond
Water flow pattem for
lndlvlduallots.
~
Note: 8ullder to ensure
positive drainage away
from structure(s).
~
~
=~=
~
Assumed North
Scale: 'I" = 30'