HomeMy WebLinkAbout07020150 Site Plan
PLOT
PLAN
DRAWING ;'<01 TO BE SCALED - DlMEJ\"SIOJ\'S PREV ALEJ\l'
PROPOSED FINISHED FLOOR ELEVATION HOUSE:
H13.43
PROPOSED FINISHED FLOOR ELEVATION GARAGE: 8]2.76
000.0 ~ PRECOt\STRUCTIOI\' GRADE
I 000,0 1- PROPOSED GRADE
----7
ORNG. FLOW
SOD: 28:t. sq.yds.
Hydroseed Area: 0,000 ::t: sq.Ft.
HOUSE WALK: 30:i: S<,j. Ft.
DRIVE/APRON: 270:1: Sq. Ft.
CITY WALK: 80 :I:: Sq. Ft.
w
U
<{
--1
Cl.
o
Z
--1
<{
(f)
o
n::
Water
Lateral
NOTE:
~~w
a: Cl. 0.:
'r-
N<D
~~
~- b~'
o ;.n
.0
-'0 WN
ON ::J
ft .c- w170"
0:
~~ ill
~4.:>
cn-l >
O:ow
lJ.J "-.-1
iJt) ill
o
~
0: .
00::'
w-o;
-0;'
ou'
a::uGj
~'-:u:J
0"'
o
~
Z'
0;0
0"
->
O:W
W-.-l
:;::w
Scale: 1" = 30'
Job. No. 07-0001
Date: 1-23-07
Drawn By: JEC
Revision Date: 2-22-07
Revision: Bold Common Wall
ammon a
o .1
CommonvV,lil I'
W
0.:
IT SHALL BE THE RESPONSIBILITY OF THE BUILDER/CONTRACTOR
TO VERIFYTlIE BUILDING DIMENSIONS, BUILDING LOCATIONS. THE
LOCATION OF OTHER PERTINE:>."T FE,....TURES, ELEVATIONS, AND ALL
UNDER GROUND UTILITIES (HOLEY :-'IOLEY 1-~OO-382-5544) PRIOR TO
THE START OF CONSTRUCTION, TI-lE Jj\'TE~DED USE OF TH]S PLOT PLAN
IS FOR SECURI:\G HUILDI.'lG PERMITS ONLY AND SHALL NOT BE
USED FOR ASY OTHER PUR?OSE.
.,.
0>
0>
o
OJ
'" Co
m (")
~ L!')
v N Co1
if>
'r
..c:
~
L
o
Z
Th,,,n'irOLvOr'hi,lo'iic, in nood 1O"C "X"" ",ic<l lrom
H"'KtMap"180S7C0226F,noodio,uraocr,Lcm,p
\~~1!~~L1\;;~[F~bi{;;,!;i9.n2iE.,'''d
The a""rac')' of .n)' n"odho,iIJ1J dala '~o~'n on (his plm plan
i,;ubjcn'om'p;"~1c un<crtain<v."dwan)'olhcr,,"ccrt"inl)'
mioc,nnnD,dov.uonundtere(erellCcdn(HxJm,ur"nCOfalC"'ap
NOTE:
THIS DRAW]NG]S NOT INTENDED TO BE REPRESE:\TED
AS A RETRACEMENT OR ORIGINAL BOUNDARY SURVEY.
A ROUTE SURVEY OR A SURVEYOR LOCATIOI'> REPORT
11/ NOTE,
\\\\\\\\ 1111///1. IT IS THE RESpm;SlBILlTY OFTHECONTRACTORTO VER]FY
~ 0", _~:.,~ ~ IQ %FINAL HOUSE DIMENSIONS PRIOR TO .....Ny CONSTRUCTION
.:::: tf,.~::;\ST(ft~'" ~ ~
~J...:.... ... No. (J,_'i ~
= 9700013 =
~ . STATE OF ,- ~
% ~1".-'N,D!",~_~"'~cr.$
~/, D SUR"'- ~~
111111//11\\\\\\\
SIG;-<ATURE REPRESEJ'.;'TS RECEWf OF PLOT PLAN HI' CUSTOMER
Lot: 104
Ryland: Building I
Townhomes at Arden
HAMILTON COUNTY, INDIANA
Lot 104: 862 ROSALIND PLACE
NOTE:
VERIFY SANITARY LATERAL LOCATION
PRIOR TO DRIVE CONSTRUCTION
.."
0-
~.,.
o~
~,.:
"-
ocfB
00",
..c~N
0_ N
({Jom
a. .
~oo
IUZ
"'<::
a; c (J)
E ~ E
ro ':; 2
OffiCi)
c
(<") ......: u.i?3 ~
~ ~ r; 1:)8 -g; ~
~N 0..;::
0C"l eoeO'-
.....l,...: '-0...
II
<::
Q)
E
Q)
"'
l-.')""":
0-
r" Q)
-~
ow
"',.'
~
E,
c,
0'
U5i
'0
.
N 1l1.!<il ~ 0
~ :=l8.';:: In
N eopO
I~Q
This plntp]an was prepared
frumarceordcdplal,rccurdcd
as lnst. No, 2007001171, and
dalcdJanuary 5.2007
20'
I
0' 10' 20'
~
GRAPHIC SCALE IN FEET
Dale:
T. WRIGHT CORP.
LAND SURVEYING SERVICES
360 S. Madison Avenue, Suite 10a
Greenwood,lndiana46142
PP~71Rg~g~~gj~O
twnghlcorp,com
Page 1 0[5
Lillard, Sarah N
From: Bruder, Ed [ebruder@ryland.com]
Sent: Friday, March 02, 200710:04 AM
To: Lillard, Sarah N
Subject: FW: TH @ Arden Building #1 REV1
Sarah,
I wanted to get you these corrected plot plans ASAP. In reviewing the plot plans, there were a few details that
needed changed to make them as accurate as possible. I have listed the items below.
(1) Shifted the entire building 1'-0" toward the front to lengthen the drives to 20' and 18' to the curbs.
(2) Corrected individual plot plan fioor elevations to match the correct elevation that was noted on the overall
building plot plan.
(3) Corrected an elevation noted in the front of unit 105.
I am sorry for the inconvenience of the updated plans. Please let me know if you have any questions concerning
these updated plot plans. Thank you for all of your help.
CE,dwan{ L (]3ruder II
Project Coordinator
Ryland Homes
9025 N. River Road Suite 100
Indianapolis, IN 46240
o.~-
(317) 846-2963 Office #
(317) 846-4224 Fax #
(317) 710-6434 Mobile
w-
-----Original Message-----
From: James Cushing [mailto:jamesc@twrightcorp.com]
Sent: Friday, March 02, 2007 9:30 AM
To: Bruder, Ed
Cc: Roberts, Stephen Allen
Subject: Re: TH @ Arden Building #1 REV1
Ed,
Here is the Arden revision. I have corrected the typo in the elevation on 105, added the sanitary sewer info,
moved the building, and adjusted the concrete numbers to refiect the move. We will have one more revision
coming your way, once we have the appropriate information for the "Analysis" box. Please let me know if you
have further changes, or questions.
Thank you,
James Cushing
Senior Draftsman
T. Wright Corporation
Land Surveying Services
360 S. Madison Avenue
Greenwood, IN 46142 Suite 109
3/2/2007