Loading...
HomeMy WebLinkAboutEXTERIOR - A102 - EXTERIOR WORK LEVEL 2 PLANDW D W *A4214 *A201 9 *A201 8 *A201 10 *A201 12 *A201 13 *A201 14 *A201 2 *A2011 *A201 4 *A201 7 *A201 15 *A201 6 *A2015 *A201 3 *A201 11 2 1 1 1 4 5 6 77 2 *A102 16 *A201 200A* 16 *A201 INTERIOR RENOVATION UNDER SEPERATE PERMIT 200B* G G *A421 7 *A4219 2 *A101 SK-1 2 A.. TUCK POINT EXISTING BRICK AS REQUIRED. B. RECAULK ALL MASONRY EXPANSION JOINTS. C. CLEAN ALL MASONRY W/ MILD DETERGENT AND LOW PRESSURE WASH PER BRICK INSTITUTE STANDARDS AND RECOMMENDATIONS. D. REPAINT ALL EXTERIOR HOLLOW METAL AND OVERHEAD DOORS AND FRAMES. E. REPLACE METAL ROOF AND FASCIA PANEL FASTENERS AND PROVIDE WATERTIGHT SEAL. REPAINT ALL METAL ROOFING - SEE SHT. *A121 ROOF PLAN FOR ADDITIONAL NOTES AND PLANS. F. REPAIR, PREP AND REPAINT ALL EXTERIOR GUARDRAILING - U.N.O. G. SEE SHT. *A101 FOR ADDITIONAL NOTES. GENERAL NOTES 1. REPLACE EXISTING RAILING SYSTEM W/ 42" H. GUARDRAILING AND 36" H. HANDRAILING, ALL TO BE PAINTED. 2. REPAIR DAMAGED CONCRETE DECK EDGE. 3. NEW STOREFRONT ENCLOSED VESTIBULE, MATCH EXISTING ADJACENT STOREFRONT SYSTEM IN COLOR AND FINISH. 4. NEW PORTE-COCHERE, REFER TO ENLARGED PLAN. 5. EXISTING CONCRETE PATIO TO REMAIN, REPAIR AS NECESSARY AND RESEAL WITH TEXTURED EPOXY PRODUCT. 6. NEW SOFFIT/CEILING SYSTEM 7. REPLACE EXISTING CLEAR-STORY GLAZING SYSTEM, REPAIR/REPLACE FLASHING. 8. PROVIDE EXTERIOR WINDOW TO MATCH ADJACENT MATERIAL AND FINISH. MATCH HEIGHT OF EXISTING ADJACENT WINDOWS. SEE ELEVATION ON *A201. 9. INFILL MASONRY WALL OPENING. MATCH EXISTING ADJACENT WALL CONSTRUCTION. KEY NOTES EXISTING CONCRETE PATIO TOPPING, REPAIR AS NECESSARY. PREP TO RECEIVE NEW WATERPROOF DECKING SYSTEM. DEX-O-TEX ELASTOMERIC PEDESTRIAN DECKING SYSTEM WITH TRACTION GRANULES CONTINUOUS CAULK BEAD TO PROVIDE DRIP EDGE AROUND ENTIRE EDGE OF 2ND FLOOR CONCRETE PATIO REMOVE AND REPLACE BACKING ROD & CAULK EXISTING RAILING TO REMAIN, REPAIR AS NECESSARY, PRIME & PAINT. EXISTING WATERPROOF MEMBRANE TO REMAIN EXISTING GUTTER. INSPECT, CLEAN AND REPAIR AS NECESSARY, HAS PROPER SLOPE AND IS DISCHARGEING TO A STORM WATER SYSTEM. 2"10'-8"2"7'-10"2"11'-0"8'-0"PROJECT #: DRAWN:CHECKED: REVISIONS CERTIFICATION: 1063 Central Avenue Cincinnati Ohio, 45202 p: 513-241-4422 f: 513-241-5560 www.ATA-B.com EXTERIOR RENOVATION 23048 TS/MA KB *A102 EXTERIOR WORK LEVEL 2 PLAN 1300 EAST 96TH STREETINDIANAPOLIS, IN 46240SCALE:1/16" = 1'-0"*A102 FLOOR PLAN - LEVEL 2 EXTERIOR NEW WORK 1 SCALE:1 1/2" = 1'-0"*A102 EXISTING LEVEL 2 PATIO EDGE 2 G NORTHNON EXTERIOR SET OF DOORS, PROVIDE 1" DOUBLE GLAZING w/ LOW E COATING ON SECOND SURFACE. FRAME THICKNESS IS 2". TTTT T T T T ON INTERIOR SET OF DOORS, PROVIDE 1/4" GLAZING. FRAME THICKNESS IS 1 3/4"". # DATE DESCRIPTION 08-09-23 EXTERIOR BID SET 08-15-23 ZONING SUBMITTAL 4/9/2024