Loading...
HomeMy WebLinkAboutINTERIOR - A101 - FLOOR PLAN - LEVEL 1DN DW D W A103 2 CPN OFFICE 119CPN OFFICE 118 CPN OFFICE 117 CPN OFFICE 116 STORAGE 130 OFFICE 133 OFFICE 135 OT APARTMENT 137 OT TOILET 138 TOILET 139 PEDIATRIC THERAPY 141 PRIVATE TREATMENT 143 PRIVATE TREATMENT 144 OT KITCHEN 149 SPORTS COURTS 120 SPORTS COURTS 147 THERAPY POOL ROOM 165 VESTIBULE 164 EXEC. BOARD 107 CLINICIAN OFFICE 163 STORAGE 166 UNISEX 169 CAFE 103 BILLING OFFICE 105 CLOSET 104 GYM 161 CONFERENCE 151 ELEV. EQUIP. 162 COUNSELOR OFFICE 158 SPEECH THERAPY 156 STORAGE 108 WOMEN 110 MEN 112 CPN OFFICE 114 GROUP EXERCISE 123 STORAGE 124 ELECTRIC 127LAUNDRY 126 BREAK 128 MEN'S LOCKERS 152 WOMEN'S LOCKERS 155 EX. ELEV. E2 MULTI-PURPOSE 160 VESTIBULE 106 MEN 153 WOMEN 154 RECEPTION 102 JANITOR 109 JANITOR 150 BASKETBALL 159 CLOS. 131 PHYSICAL THERAPY 142 HALL 129 PERSONALIZED EXERCISE 140 WAITING 101 STORAGE 170 ELEVATOR E1 RISER ROOM 125 A103 1 UNISEX 168 STORAGE 167 147D* 120C 120D* 147C UNISEX 115 TECH OFFICE 134 RESEARCH OFFICE 136 STORAGE 121 SUPPORT SPACE 122 STORAGE 145 STORAGE 146 STORAGE 148 146 148 145 STORAGE 132 STAIR No. 4 S4 A. DIMENSIONS ARE TO FACE OF SHEATHING, COLUMN CENTERLINE, FACE OF NOMINAL MASONRY/CONCRETE UNLESS OTHERWISE NOTED. B. PROVIDE BLOCKING IN PARTITION WALLS AS REQUIRED FOR SUPPORT OF ALL WALL MOUNTED EQUIPMENT AND ACCESSORIES. REFER TO INTERIOR ELEVATIONS AND EQUIPMENT PLANS. C. REFER TO SCHEDULE SHEET FOR INFORMATION ON DOOR, WALL, WINDOW, FIXTURES & EQUIPMENT. D. CONTRACTOR TO COORDINATE REQUIRED ROUGH OPENING SIZES. E. USE MOISTURE RESISTANT GYP. BD. IN ALL WET AREAS. F. WALLS w/ GRAY TONE INFILL ARE EXISTING TO REMAIN U.N.O. G. PATCH/REFINISH ALL DISTURBED WALLS AND SURFACES FROM DEMO/REMOVAL ACTIVITY AS REQUIRED TO MATCH NEW CONSTRUCTION/FINISHES. H. ALL EXISTING INTERIOR WALLS TO REMAIN ARE TO BE PATCHED, REPAIRED AND TO RECEIVE PAINT. REFER TO ROOM FINISH SCHEDULE. GENERAL NOTES 1. INFILL EXISTING OPENING IN WALL w/ METAL STUD/GYP. BD. CONSTRUCTION. 2. ADD DARK TINTED FILM TO EXISTING WINDOWS. 3. INFILL ELEVATOR DOOR OPENING SIMILAR TO ADJACENT WALL CONSTRUCTION. 4. PATCH EXISTING MASONRY WALL TO MATCH ADJACENT EXTERIOR WALL VENEER. 5. REPAIR WATER DAMAGED GYP. BD. WALL/FINISHES. 6. CLEAN, PREP STEEL STAIR RISERS, RAILINGS AND SUPPORT COLUMNS PRIOR TO PAINTING. 7. CLEAN, PREP AND PAINT CMU WALL w/IN EXTENTS INDICATED. 8. RELOCATE EXISTING STORM RISER TO INSIDE WALL FRAMING AND RECONNECT TO EXIST. UNDERGROUND STORM LINE. 9. PROVIDE FURRING/GYP. BD. OR PATCH EXISTING FURRING AS REQUIRED. 10. ALIGN NEW FRAMING & FINISH WITH EXISTING CONSTRUCTION. 11. FURR OUT w/ GYP. BD. FINISH INSIDE OF OPENING IN WALL. ALIGN w/ WALLS. 12. LOW HEIGHT WALL, 48" TALL. PROVIDE CLARK DIETRICH 'PONY WALL' TYPE FLOOR MOUNTED BRACING. HOLD TIGHT TO EXISTING COLUMN. INSTALL PER MFR'S RECOMMENDATIONS. 13. REMOVE/RELOCATE EXISTING ELECTRICAL PANELS, SEE ELECTRICAL DRAWINGS. 14. 'DRIVEN' SIGNAGE BY OWNER. 15. TV MONITOR, COORDINATE HEIGHT & PLACEMENT WITH OWNER. 16. REPAIR WATER DAMAGED GYP. BD. FINISH ON WALLS. 17. SEMI-RECESSED FIRE EXTINGUISHER CABINET. 18. GYP. BD. METAL STUD WRAP - HOLD TIGHT TO COLUMN. FLOOR PLAN KEY NOTES PROJECT #: DRAWN:CHECKED: REVISIONS CERTIFICATION: 1063 Central Avenue Cincinnati Ohio, 45202 p: 513-241-4422 f: 513-241-5560 www.ATA-B.com INTERIOR RENOVATION 23048 TS/MA KB A101 FLOOR PLAN -LEVEL 1 1300 EAST 96TH STREETINDIANAPOLIS, IN 46240SCALE:1/16" = 1'-0"A101 FLOOR PLAN - LEVEL 1 1 NORTHN # DATE DESCRIPTION 06-02-23 DESIGN DEVELOPMENT 07-28-23 PERMIT & BID 08-15-23 ZONING SUBMITTAL 1 08-18-23 DOH REVIEW COMMENTS 2 12-08-23 OWNER CHANGES 2