HomeMy WebLinkAboutINTERIOR - A101 - FLOOR PLAN - LEVEL 1DN
DW
D W
A103
2
CPN
OFFICE
119CPN
OFFICE
118
CPN
OFFICE
117
CPN
OFFICE
116
STORAGE
130
OFFICE
133
OFFICE
135
OT
APARTMENT
137
OT TOILET
138 TOILET
139
PEDIATRIC
THERAPY
141
PRIVATE
TREATMENT
143
PRIVATE
TREATMENT
144
OT
KITCHEN
149
SPORTS
COURTS
120
SPORTS
COURTS
147
THERAPY
POOL
ROOM
165
VESTIBULE
164
EXEC.
BOARD
107 CLINICIAN
OFFICE
163
STORAGE
166
UNISEX
169
CAFE
103
BILLING
OFFICE
105
CLOSET
104
GYM
161
CONFERENCE
151
ELEV.
EQUIP.
162
COUNSELOR
OFFICE
158
SPEECH
THERAPY
156
STORAGE
108
WOMEN
110
MEN
112 CPN
OFFICE
114
GROUP
EXERCISE
123
STORAGE
124
ELECTRIC
127LAUNDRY
126
BREAK
128
MEN'S
LOCKERS
152
WOMEN'S
LOCKERS
155
EX. ELEV.
E2
MULTI-PURPOSE
160
VESTIBULE
106
MEN
153
WOMEN
154
RECEPTION
102
JANITOR
109
JANITOR
150
BASKETBALL
159
CLOS.
131
PHYSICAL
THERAPY
142
HALL
129
PERSONALIZED
EXERCISE
140
WAITING
101
STORAGE
170
ELEVATOR
E1
RISER
ROOM
125
A103
1
UNISEX
168
STORAGE
167
147D*
120C
120D*
147C
UNISEX
115
TECH
OFFICE
134
RESEARCH
OFFICE
136
STORAGE
121
SUPPORT
SPACE
122
STORAGE
145
STORAGE
146
STORAGE
148
146
148
145
STORAGE
132
STAIR No.
4
S4
A. DIMENSIONS ARE TO FACE OF SHEATHING, COLUMN
CENTERLINE, FACE OF NOMINAL MASONRY/CONCRETE
UNLESS OTHERWISE NOTED.
B. PROVIDE BLOCKING IN PARTITION WALLS AS REQUIRED FOR
SUPPORT OF ALL WALL MOUNTED EQUIPMENT AND
ACCESSORIES. REFER TO INTERIOR ELEVATIONS AND
EQUIPMENT PLANS.
C. REFER TO SCHEDULE SHEET FOR INFORMATION ON DOOR,
WALL, WINDOW, FIXTURES & EQUIPMENT.
D. CONTRACTOR TO COORDINATE REQUIRED ROUGH OPENING
SIZES.
E. USE MOISTURE RESISTANT GYP. BD. IN ALL WET AREAS.
F. WALLS w/ GRAY TONE INFILL ARE EXISTING TO REMAIN U.N.O.
G. PATCH/REFINISH ALL DISTURBED WALLS AND SURFACES
FROM DEMO/REMOVAL ACTIVITY AS REQUIRED TO MATCH
NEW CONSTRUCTION/FINISHES.
H. ALL EXISTING INTERIOR WALLS TO REMAIN ARE TO BE
PATCHED, REPAIRED AND TO RECEIVE PAINT. REFER TO
ROOM FINISH SCHEDULE.
GENERAL NOTES
1. INFILL EXISTING OPENING IN WALL w/ METAL STUD/GYP. BD.
CONSTRUCTION.
2. ADD DARK TINTED FILM TO EXISTING WINDOWS.
3. INFILL ELEVATOR DOOR OPENING SIMILAR TO ADJACENT WALL
CONSTRUCTION.
4. PATCH EXISTING MASONRY WALL TO MATCH ADJACENT
EXTERIOR WALL VENEER.
5. REPAIR WATER DAMAGED GYP. BD. WALL/FINISHES.
6. CLEAN, PREP STEEL STAIR RISERS, RAILINGS AND SUPPORT
COLUMNS PRIOR TO PAINTING.
7. CLEAN, PREP AND PAINT CMU WALL w/IN EXTENTS INDICATED.
8. RELOCATE EXISTING STORM RISER TO INSIDE WALL FRAMING
AND RECONNECT TO EXIST. UNDERGROUND STORM LINE.
9. PROVIDE FURRING/GYP. BD. OR PATCH EXISTING FURRING AS
REQUIRED.
10. ALIGN NEW FRAMING & FINISH WITH EXISTING
CONSTRUCTION.
11. FURR OUT w/ GYP. BD. FINISH INSIDE OF OPENING IN WALL.
ALIGN w/ WALLS.
12. LOW HEIGHT WALL, 48" TALL. PROVIDE CLARK DIETRICH 'PONY
WALL' TYPE FLOOR MOUNTED BRACING. HOLD TIGHT TO
EXISTING COLUMN. INSTALL PER MFR'S RECOMMENDATIONS.
13. REMOVE/RELOCATE EXISTING ELECTRICAL PANELS, SEE
ELECTRICAL DRAWINGS.
14. 'DRIVEN' SIGNAGE BY OWNER.
15. TV MONITOR, COORDINATE HEIGHT & PLACEMENT WITH
OWNER.
16. REPAIR WATER DAMAGED GYP. BD. FINISH ON WALLS.
17. SEMI-RECESSED FIRE EXTINGUISHER CABINET.
18. GYP. BD. METAL STUD WRAP - HOLD TIGHT TO COLUMN.
FLOOR PLAN KEY NOTES
PROJECT #:
DRAWN:CHECKED:
REVISIONS
CERTIFICATION:
1063 Central Avenue Cincinnati Ohio, 45202
p: 513-241-4422 f: 513-241-5560 www.ATA-B.com
INTERIOR
RENOVATION
23048
TS/MA KB
A101
FLOOR PLAN -LEVEL
1 1300 EAST 96TH STREETINDIANAPOLIS, IN 46240SCALE:1/16" = 1'-0"A101
FLOOR PLAN - LEVEL 1
1
NORTHN # DATE DESCRIPTION
06-02-23 DESIGN DEVELOPMENT
07-28-23 PERMIT & BID
08-15-23 ZONING SUBMITTAL
1 08-18-23 DOH REVIEW COMMENTS
2 12-08-23 OWNER CHANGES
2