HomeMy WebLinkAbout07030030 Reciepts/Permits (2)
Regional Waste District
; ,
SF Residential
723402007
SANITARY SIEWER PERMIT
f....
INDIVIDUAL LOT / EXISTING BUILDINGS'
Subdivision Claybourne
Builder Ryland Homes
3
Lot Number 252
Address Number 13198
Street Salamone Way
City Carmel
County Hamilton
Permit Type Final
Lift Station 14 Austin Oaks Station
Treatment Plant CTRWDWWTP
-i
Parcel Acreage
Employees'
Square Footage
EDU Fee
Application Fee
Fees Due
. Invoice Number
$1,650.00
$100.00
$1,750.00
I
PLEASE NOTE: Installation of building sewer shall be per the specifications of the. Clay Township Regional Waste
District (see reverse) and any conditions noted below. All installations shall be inspected by District personnel during
"open trench" phase and before backfilling with stone to six inches above the pipe. NO footing or foundation drains, or
other sources of ground or stormwater, shall be permitted to enter the District's sanitary sewer system. The District will
assume no liability for drains which are below the grade level of the nearest downstream manhole nor for laterals
which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be
responsible for damages to the District's sewer system. This includes damages to manholes, castings, manhole lids
and the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 844-9200
24 hours in advance. All new construction will be placed on billing six months after connection has been made or when
water is connected, whichever comes first.
Up CBN2-67 CBN2-66 Down
The building has a: Grease Trap No Slab Foundation No Lid Elevation 912.98 It 914.47 It
Grit Interceptor No Crawl Space No First Floor Elevation 916,10 It 916.10 It
?, Grinder Station No Basement Yes Basement Elevation 907.10 It 907.10 It
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor r--~3~12l-'----1~6=il
~~OO ,. "'" ,," .. 0000,"', """",. "" '"""'"""" ... "".__ "', '''mood wHh G';'d" ',mp,
. Installed I
The District reserves the right to inspect all sump pump connections to ensure no illegal connections have been mad~.
Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner. .
Conditional Permit Terms:
Plans Submitted No
No Connection No
Certificate of Insurance No
tnspection Notice No
Fees Paid No
. Plan Review No
Other Permits No
No Occupancy No
Fats, Oils & Grease No
Two sets of plans showing at least one sanitary manhole and top of casting elevation
NO CONNECTION to the sewer until further notification. I
I
Certificate of Insurance must be on file with CTRWD listed as certificate holder.
All District fees will be paid in full.
No occupancy until further notification
Fats, Oils and Grease Facilities will abide by District standards
and agree to accept responsibility for all work done under this permit.
Builder I Owner Signature'
Phone Number
Printed Name
Approved
Permit Date 10/14/2005
Y J. Feltner, Director of Administration & Customer Service
Revised 2/2/07' Permit is valid for ONE-YEAR from the date issued. Permit valid only with CTRWD seal in red ink.
~.~..,
.- Schleider
The Schneider Corporation
8901 Otia Avenue
Hiatoric Fort Harrison
IIId!allApolll, IIId!aIIA 46216-1007
317-626-7100
317-626-7200 fAX
EnMin....."
_eying
Landscape Architecture
GIS 'US
Geoloey
Note:
This drawing is bosed on construction pions or record
drawings, and is not bosed upon 0 field survey. The
Schneider Corporotion does not worront the occuracy or
sufficiency of this information. Contractors should verify
existing conditions prior to any construction. Any
discrepancy found on this drawing should be reported to
The Schneider Corporation immediately; foiling to do so
results in the contractors assumption of all liability.
Note:
The basement elevation, depicted hereon, has been determined and
bosed on the pad grades and/or contours taken from the construction
pIons for this subdivision. Unless stated, no Information about
fluctuating water tables. son conditions, or son twes has been
provided or stated on said plans. This lot Is located near 0 body of
water, Lot or son conditions may require that the basement floor
elevation be held 2 foot above normal pool elevation, Site investigation
may be needed if water is encountered during the excavatlon process
or if other known water elevation or soils conditIons ore present
Investigation and any remedial procedures Is at the discretion of the
bu~der to determine and take appropriate steps of action, If any
ground water is encountered during excavation the bu~der Is
encouraged to contact The Schneider COl1loration to discuss possible
course:! of action,
Note: Sump pump(s) to be
placed by builder as needed,
Lot # 252
Vb07.0068379
~
D
=~=
Plot Pion Legend
This Plot Plan Prepared For: R.H. of Indiana
Lot # 252 , containing 10,500 SJ.:!:, in
Oa)Ooume
Section # 3
INSlR. # 200400080247
P.C. # 3, Slide # 533
HamHton County, Oay Twp
Sec 30, T1aN, R03E
13198 Salomone Way
Carmel, IN 46074
Prepared Oote: 02/08/07: By: AMA
Proposed Buyer(s ): Christoph erDoyi d-H aas
(50'RfW)
Community Restrictions:
Side Yard = 5'
Rear Yard = 20'
Aggregate = to' (S.H.)
Zoning = 51
R.H. of Indiona
Finished Floor Elevation Information
Pod Grode = 9t 3.9 per plan
Pod Grode + 0.7' = Gorage FfE (914.6 )
Garoge FFE + 1.5' = Residential FFE (916.1)
. Residentiol FFE - 9.0' = Bosement FFE (907.1 )
Note: The garage finished noor elevation
is 2.3' above the curb at the drive, per pion.
Ground Cover Calculations:
Drive = 796 SF f
Public Wolk = 314 SH
Private Walk = 89 SFf
Hydroseeding = 4,928 SH
; Sod = 308 SYf, from
Rear of residence,
Optionol Sod Pockoge
Hydroseeding = 2,250 SF f
Addl. Sod Pkg. = 298 SYf, to
Rear easement.
",
c.j
::oi
~
o
o
..0
r--
~I
~I
I
I
I
I
~I
w
w
~I
~I
:51
~I
<<
~(
C2ISl
"'~
, ~
"'I'"
",0
'"
~
167.6'
I
[QQ[[J Proposed Grades
000,0 Existing Grades
_000,0- Contour Grade
* Approx. Lateral Location
- . - Sonitary Sewer Lines
-11'- Storm Sewer Lines
- '" - Water Service Lines
- - - - - - - Sub-Surface Drain Lines
. Manhole (Sanitary or Storm)
. Beehive Inlet (Storm)
II!I Curb Inlet (Storm)
D End Section (Stonn)
..... fire Hydrant
- 000 _..0 -flow Line of swole
- Building Une (SL / BSL)
- - - - - - - Easement Line
Note: Sanitary Sewer
Top of Casting Information
Upstreom Manhole, TC= 912.98
Downstreom Monhole, TC= 914.47
per record drawing
. ~I ~<
~
TYPICAL SWALE SECTION
Note:
The contractor is to maintain 0 minimum
distance of ten feet (10') between the
sanitary sewer and water line laterals.
Sidewalk to be placed
l' from property line,
4' from back of curb,
per plan,
15
~
.6'
1913.4 I
~ 140.00
17.
<~tj
~d
'8 ~
~~~ ~ '"
0
~~
~ ~ iii~
~
'"
~
13.33'
I
~I
~ I '
~ ~u~ II t~:
~ VJ ~l
Note: Per Carmel zoning ordinance 26,1.1 : The residential district
limits height to twenty-five feet (25'), however a dwelling may be
increased in height to thirty-five feet (35') provided the side and rear
yards are increased on additional one foot (1') for each one foot (1')
the structure exceeds the first twenty-five feet (25') in height.
N
1i!1
8
~
140.00'
17.4
-40.38' ~
This drawing is not intended to be represented os 0 retracement or
original boundary survey, a route survey, or a Surveyor Location Report.
I
,>
: I
FLOOD HAZARD STATEMENT
CERTIFICATION
~
Assumed North
Scale: ," = 30'
C,8~L
SlR f 67
TC=91.96
PER RECORD
DRAv"NG
~ -
~ -
j;;
;:!
'8
;s~ ~ I
~~ ""
~ d
N
13.G"
91.4 1'1
26,01
7'
I
t1.5'
I
'" ~
..,
'" =>
N '"
".,
"
a;
C8N
SIR. , 66
TC=9f4A7
PER RECORD
ORAv"NG
Detail of Ground/ Storm
Water flow pattern for
individual lots.
em
-M-
-w-
- - --
Note: Builder to ensure positive
drainage away from structure(s).
>
&)
~
~
~
~a.1
~~r
~~
~~
~'"
"'.., I
No:: .
0;
up:; / ~
~irl
>-
<I::
3
is
~
'l<
w
:z
'" --;;- 0
gl ::::2;
~ <'(
""l --1
~c;:I <I::
UJ
,.
I
,
30.0'
8-8
,\\\\\\\\llIlllIlI/illllll/,
,#\\\ S L C, lijl,% '
#~~ ,.......:......:f,0~
~<.<:5 /'G\ST€'f?;:""o/".A~
~ .~ N "'. "....,.~
~c--..../~ 0 ()\A~
, i' 50303 )'1
% ..... STATE OF ..... @
:::::: <,," .'::::
'% A/f1"",:'I'vDJAt.\~,""~ff
~'Y'~1l .............\"" ~
~ l/ SUO\I "ii!
~ij/I. t\ 't \\,#
1/lllllllIlIlilllll\\\\\\\\
-\::l'- l . ffI
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate map. ALL of the within described land DOES NOT He within that special flood hazard
zone AE as said land plots by scale on flood insurance rate map #1800810205 F for the City of
Carmel, Indiana dated February 19, 2003.
SIGNA lURE :
DATE:
~GNA lURE REPRESENTS CONRR~A ~ON OF RECEIPT Of PLOT PLAN SY CUSTO~ER.