Loading...
HomeMy WebLinkAbout07030028 Site Plan ~~ Schn8ider This Plot P1C11 Prepcnd Fer. 11ft Hames Lot # 48, contoiningl0,941 S.F.:!:, in Heother Knoll Section , 2 Instrument # 2006-00004470 PC 4 Slide 13 Ooy TOIIII8h". HamllCII County SEe 20. nllN. R03E 14334 HEATHER KNOLL PKWY (70' R/'IfJ Westfield, IN 46074 Prepore"d Dote: 02/26/07: By: KAG Community Restrictions: Side Yard = 3' min. Aggregate = 6' 8.H. Zoning - SI !be SchneIder CorporoUon 8901 OUI ANDue Hiotoric fort _ IDdlaIIapcllo, IDdIaDa _8-103'7 317-828-7100 317-828-7200 fAll Note: This drawing is based on construction pions or record drawings. and is nal based upon 0 field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately. famng to do so results in the contractors assumption of 011 liability. M/I HOMES Pod Grode = 919.1 per plan Pod Grode + 0.2' = Garage m (919.3 ) Garage FFE + 0.5' = Residential FFE (919.8 ) Residential FFE - 9.0' = 8asement FFE (910.8 ) Oriveway Slope = 4.2:1: Note: The garage finished floor elevation is 1.9' above curb inlet, per record drawing. GROUNO COVER CAlCULATIONS: Orive = 1,026SFt Public Walk = 323 SF t Pri1lOte Walk =n/a SFt Seeding =5,499 SFt Sod = 318 Srt, from front of residence. 918.3 ~ SlIrnytJlc LandIcopo _........ CIS .us Ceol.., Plot Plan legend [QQ[jU Proposed Grades 000.0 Exisling Grades __ 000.0-- Contour Grade * Approx. lateral location - . - Sanitary Sewer lines -.,- Storm Sewer Unes - v - Water Service lines - - - - - - - Sub-Surface Drain lines . Manhole (Sanitary or Storm) . Beehive Inlet (Storm) l1li Curb Inlet (Storm) D End Section (Storm) ... Fire Hydrant - 000 - ...." - Flow Line of swole - Building Une (Bl / BSl) - - - - - - - Easement line Note: Sanitary Sewer Top of Costing Information Upstream Manhole, TC= 918.71 Downstream Manhole, TC=917.14 per record drwg. Note: The contractor is to maintain 0 minimum distance of ten feet (10') between the sanitary sewer ond water line laterals. C.A. #8 R. MA 15 ~ I~ 0 .l!; C> I~ d CXJ 53.0' 410' 917.2 131.22' ~ 11.2' 8 21.00 g 29.JJ ~l!l ~ ~ i~ I m .00' !S~l:j >- iU 2.00 Ii! " !SS! ~E 35.61 __.iD___ \1.2' 9.3' 10.0' 918.1 138.12' FLOOD HAZARD STATEMENT CERnFICA nON ~,,\,,\\I\lIIII"II/I"III/, #" S L c;jt~ ,# ~ ......:.... "'h;%; ~ ~....~G,SNTE"J?:;.:6......."""~ ~<::::)..'q. 0 ". /O~ I \.f 50303 ) ~ - :=: % ..... STATE OF ./ ~ ~ /', ,,~ ~ (' ~.....!.IvD' A~~.....~~ % '#J '.S'..'U..R.'\iC~ ,# ~41/, , \. ~~~ ~IIIII1/II/IIII\I\\I""'" '\:L l . Wr1 This drawing is not intendt ~o be ~re:resented os 0 retracement or original boundary survey, 0 route survey, or 0 Surveyor Location Report. Flood Hazard Statement: The accuracy of any fiood hazard data shown on this pial plan is subjed to mop scale uncertainty and to any other uncertainty in location or ele1lOtion on the referenced flood insurance rote mop (FIRM). None of the within described land lies within that special flood hazard zone" A", os said land plots by scale on Community Mop Ponel , 18057C0205F of the fiood insurance rote mops (FIRM) for Hamilton County, Indiana, Oated May 19, 1981. Note: The basement elevation. depicted hereon, has been determined em bosecI on the pod lJ'odes ood/or contours lcien frcm the construction p1C1lS for this !UbclMsion. Unless stoted, no information about ftuctuoting water tables, sol conditions, fX soi 1)PeS has been provided 01 stoted on said pions. This lot is located neG' 0 body of water. Lot or soil condilicm may ~i"e that the basement "oar elevation be I'IeId 2 foot dMM normal pool elevction. Site iwestigation may be needed if waler is encountered ck.Irilg the ncowlion process or if other known water elevation or soils conditions cre present. Investigation nI (I'IY remadiol pracectJres is at the cflStl'eticwl.of-the buidtr to determine md Ic*e appropriate steps of oc:tion. If ony CJ'"ound woter is encountered o..ring elcowtion the bulder is encouraged to contact The Schnelder Corporation to cflSCUSS possi:lfe courses of action. NOTE: SUMP PUMP(S) TO BE PLACED BY BUllOER AS NEEDED. LOT. 48 VB07.0069086 o ~ =~= Oetoa of Groond/Storm Water: now pattern of cr'l indMduoi lot. em -M- -~- - --- i TC=917.40 PER R[COOD I I DRAllNG i-- I I r-- I I N i I 10( ...., I I On '0" PER5.~ N 917.6 S I~ 0. ~, - R<ll aJRB llHf724 TC-917.14 PER R[COOD DRAllNC i ~ . o I 4..' 5\.OPt "- TYPICAL SWALE SECTION NOTE: IN THE RESIDENTIAL OISTRlCTS lIWmNG HEIGHT TO TIl{NTY-FlVE (25) FEET, A OWEWNG WAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PROVIDED THE SIDE AND REAR YAROS ARE INCREASED AN AOOITIONAL rOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (2S) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1.