HomeMy WebLinkAbout05100119 Correspondence FROM 7261061 Jun. 26 2006 03:15PM ) FRX NO. O"Si GOI \'1 Dave Swaim June 26, 2006 Page 2 of Z 4b. As discussed on site, the engineer of record who performed a~d certified the original truss design is to be contacted and is to determine if the notched top chord requires any reinforcement. 4c. The rloor truss that had the top chord cut out for a plumbing line has been repaired with the installation of a full depth wood panel gusset, It is my opinion that the repair is adequate 4d. The garage door header is to be modified to include wood panel aheathing on the interior, extending from the bottom of the LVL header to the top of the double plate which is approximately 25" above the bottom of the LVL. The sheathing is to be attached to each of the plates, each of the cripple studs and the LVL header with 8d nails spaced at 1-1/Z" o.c. The exterior wood panel sheathing is to also receive additional nailing. The result will be a box beam whose depth will be from the top plates to the top of door opening. 4e. The exterior, balcony, as shown on the drawings, was checked for"the code p.-escrioed loads. The 3-1/Z"xll-l/4" PSL joists spanning app.oximately 24 feet and spaced at 16" o. c. ,'the' 3-112"Xl'1~1f.4~girders_spanning_i.\pproximately 6 feet perpendicular to the wall and the 4"x4" exterior-posts' we.-e all,determined to be adequate for the code applied loadS'~ .The 'framer wa$ advised that the girder ends adjoining the'building'wall should oe suppcrted by th.-ee wall studs: Hopefully this provides the info~tion If fu.-ther information or clarification me know at your convenience. you need at this time. is required, please let Sincerely, d8- 't~- spen~ Engineering, Inc. Billy ,T. 'Spencer, P.E. "\\\lUUf",, ~,9,'t\OM4S $""'.0 J"~-<;G'S.felt;:~ ~~ ,r~ N -"<1'-. ~~ -~. 0 '~'< ... : ,.~... :: f . 1--- ~""~ 20751 j ~ \~\ $TA,TEOF l!;;S -:;(\~~ /~$ '\ <J>s. ...t0~!'''''-1,~ ~ ~';;,,:ONAl 't.~~,,'$' ''''1'1111'''\ P31 1,1',' :: i . FROM Jun. 262006 03:15PM FRX NO. 7261061 /"~\' '::':;:"n"'+ ,::"~~;.. ~'-'S-'l'~-'~- \, ~ 1/ , . } \" "'- ,I. -..., - '" .A. \~I/ \<....__ ....._ .n. __". ... ..:.~. SnNCCR BIle/NEDING, {/lie. l~ Wbit:e A.$b In. 1I'-~~giD(!CI'jnc-oom C.armeI.IN'.f6033 ~H'nu-..1!CIlD. Tel (.un &48-2394 FlU (317) 66a..&&t1 -joo<-~ ---- SWucc:uraI EDgIDeertDc June 26, 2006 Mr-;. DeL\rid Swaim MAS Associates, LLC 5200 East 64th Street, Suite A Indianapolis, IN 46220 RE: Guilford Condos Guilford Ave. Carmel, IN Dear Dave, ThiS is in response to your request that I address several of the items contained in the inspection memo from James A. Ochs, dated June 16, 2006 (Subject, 05100118, 70-120 Guilford)regarding the above referenced project. Based on our site visit on June 20, 2006 and subsequent drawing review and structural analysis and ~y return visit earlier today, the following are my responses to issues addressed in item 4 of Mr. Qch~ memo: _~_ ___ 4a. The framing for the gable end truss were found to have been ~odified to include horizontal ~outriggersH between the bottom chord of the gable truss and the bottom chord of the nearest adjacent roof truss. These consist of 2x4's spaced at approximately 16' on center. The ends of the outriggers are attached to continuous 2x4's run parallel to and nailed to the bottom chords of the gable and interior roof trusses. The outriggers cross over and bear directly over the 2x4 wall below. In addition, 2x4 diagonals have been run from each of the vertieals of the gable truss downward to the top plate assembly to transfer load to the stud wall below. The 2x12 plate that sits on the 2x4 wall top plates has 1/4'x6" lag screws attaching it through the 2x4 top plates into the studs and the 2~12 has metal straps anchoring its insidQ edge to the studs. Based on ~y review, it is my oplnlon that the gable end wall is now adequately attached and supported. P2! I