HomeMy WebLinkAboutE201 Electrical Lighting Plans (CD 12.21.2023)3-WAY SWITCH AT 48" A.F.F. (UNLESS NOTED OTHERWISE)3POWER, LIGHTING, & DATA SYMBOLSSINGLE POLE SWITCH AT 48" A.F.F. (UNLESS NOTEDDUPLEX RECEPTACLE AT 16" A.F.F. UNLESS NOTEDWATER PROOF DISCONNECTSDOTHERWISE)EXHAUST FAN - SEE MECHANICALGROUND FAULT CIRCUIT INTERRUPT RECEPTACLEGFCIGFCIOTHERWISEWPELECTRICAL PANELAJ-BOXJEFQUAD RECEPTACLE AT 16" A.F.F. UNLESS NOTEDOTHERWISEDIMMER SWITCH APPROPRIATE FOR LIGHT FIXTURESAT 48" A.F.F. (UNLESS NOTED OTHERWISE)SSFLOOR DUPLEX OUTLET WITH COVERVOICE DATA ROUGH-INGROUND FAULT CIRCUIT INTERRUPT WATER PROOFRECEPTACLEOWNER REVIEW: _________ _______________INITIALS DATERevisions:DateDrawn By Checked ByBYRUMARCHITECTSCertified ByOwnership, Use, Copy, andScope DrawingsDistribution of DocumentsCThe concept, design, and drawings for thisproject are instruments of the architect's service,are owned by the architect, and are for usesolely with respect to this project. The drawingsshall not be used on other projects or additionsto this project without written permission anddue compensation to the architect. The drawingsshall not be copied or distributed withoutauthorization from the architect, architect'spartner, or authorized representative.These drawings indicate the general scope ofthe project in terms of design, concept, thedimensions of building, the major elements and,in some cases, the structural, mechanical,and/or electrical systems. The drawings do notnecessarily indicate or describe all that'srequired for full completion of the work. On thebasis of the general scope indicated ordescribed, provide all that's required for theproper execution and completion of the work.11728 Arborhill DriveZionsville, Indiana 46077317-574-8808Copyright 2023Project No.23003E201LIGHTINGPLANS12-21-2023CADJWBSpecially commissioned by T&W Church Solutions, and used under license.E20102SCALE: 3/32" = 1'-0" BASEMENT LIGHTING PLAN NORTH
-Carmel, Indiana
2599 East 98th Street E20103SCALE: 3/32" = 1'-0" BALCONY AND MEZZANINE LIGHTING PLAN NORTHE20101SCALE: 3/32" = 1'-0" FIRST FLOOR LIGHTING PLAN NORTH LABELWATTS LUMENS APPROVED SIMILAR TO MODELD1 16 1600NU4-RD-SW-20LM-(TBD)K-80-HE70555706LZPT24-(TBD)HLG-LSRS-EDUP6546900T249 5024CFP24-55 (K TBD)T356 7364CFP24-7535 OR 7540 (K TBD)T126 3469CFP22-3335-HE OR 2840 (K TBD)EXLEGRESS & EXIT LIGHTINGLABELDESCRIPTIONEMERGENCY EGRESS LIGHT REMOTE HEAD WALLEXIT SIGN - WALL OR CEILING MOUNTED AS SHOWNELRCOMBINATION EXIT SIGN AND EMERGENCY EGRESS LIGHTEXEMERGENCY EGRESS LIGHTEL(5W/FACE MAXIMUM)OR CEILING/SOFFIT MOUNTED(5W/FACE MAXIMUM EXIT SIGN)(NL)NIGHT LIGHT CIRCUIT (FOR SAFETY AND SECURITY)GENERAL LIGHTING2L-P-ID-LPAD-6-SOF-C(TBD)-K(TBD)-I030-D085T4P436 46002L-P-ID-LPAD-4-SOF-C(TBD)-K(TBD)-I030-D085(6) P6(4) T1(3) T1(12) P4(3) T3(2) D1D1(18) P4(15) D1(10) D1(6) D1(2) T3(2) T3P8476446MPS8-(K TBD)VW-CW-EDU(3) P8(2) P8(17) D1(NL)(NL)(NL)(NL)(NL)(3) D1(NL)(3) D1(12) P4(12) P4(8) T3(8) T3(4) T3(8) T3(3) T3(3) D1(11) T3(10) T3(12) T3(7) T3(8) T3(2) T3T3P8(4) D1(4) D1(6) T4T2T2T2T2T2 T2T2T2T2(2) T3(9) T3T2(7) P8ELELELELELELELELELELELELELELELELELELELELELELELELELELELELELEXLELELELELELELELELELELELELELELELELELELELELELELELELELELELELELELELELELELELELELEXLEXLEXLEXLEXLEXLEXLEXLEXLEXLEXLELELEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXELRELRELRELRELRELRELREXLEXLP8P8EL (ON JOIST)EL (ON JOIST)EL (ON JOIST)EL (ON JOIST)HOUSE LIGHTING AT SANCTUARY, PLATFORM,BALCONY, AND A.V.L., DESIGNED BY A.V.L.DESIGNER AND MUST NOT BE DIMMABLE TO LESSTHAN 1 F.C WHEN SPACE IS OCCUPIED. REDUCTIONTO NO LESS THAN 0.2 F.C. IS PERMISSIBLE IFMINIMUM 1 F.C. IS AUTOMATICALLY ACHIEVED UPONACTIVATION OF THE PREMISES'S FIRE ALARMSYSTEM PER I.B.C. AND I.F.C. SECTION 1006.2,EXCEPTION.HOUSE LIGHTING AT MULTI-PURPOSE ROOM.,DESIGNED BY A.V.L. DESIGNER AND MUST NOT BEDIMMABLE TO LESS THAN 1 F.C WHEN SPACE ISOCCUPIED. REDUCTION TO NO LESS THAN 0.2 F.C. ISPERMISSIBLE IF MINIMUM 1 F.C. IS AUTOMATICALLYACHIEVED UPON ACTIVATION OF THE PREMISES'SFIRE ALARM SYSTEM PER I.B.C. AND I.F.C. SECTION1006.2, EXCEPTION.A.V.L. DESIGNER, INCLUDELIGHTING, AND ITS CONTROL,FOR THIS AREAA.V.L. DESIGNER, INCLUDELIGHTING, AND ITS CONTROL,FOR THIS AREASOFF(3) SOFF(3) SOFF(2) SOFF27 3800SOFFSQUARE EXTERIOR LED SOFFIT LIGHT12 1100EXTERIOR CUT-OFF WALL SCONCEWSWSWSWSWSWSALL WORK SHALL COMPLY WITH THE CURRENT INDIANA GENERAL ADMINISTRATION RULES(GAR) AND ALL CODES APPLICABLE TO THIS PROJECT INCLUDING, BUT NOT LIMITED TO,THE THE 2009 INDIANA ELECTRICAL CODE (2008 NFPA-70), THE NATIONAL FIRE ALARMCODE (NFPA-72), THE 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007WITH INDIANA AMENDMENTS), A.D.A. (AMERICANS WITH DISABILITIES ACT), ICC/ANSIA117.1-2009 (AMERICAN NATIONAL STANDARD - ACCESSIBLE AND USABLE BUILDINGS ANDFACILITIES), AND ALL OTHER APPLICABLE STATE & LOCAL STANDARDS & REGULATIONS.REPORT ANY CONFLICTS BETWEEN THESE CODES & REGULATIONS AND THE WORKINDICATED TO THE ARCHITECT/ENGINEER AT AWARD OF CONTRACT.A COMCHECK REPORT HAS BEEN PREPARED FOR THIS PROJECT AND IS AVAILABLE FROMTHE GENERAL CONTRACTOR. ALL SUBCONTRACTORS ARE EXPECTED TO OBTAIN A COPYAND COMPLY WITH THE REQUIREMENTS THEREIN.ELECTRICAL CONTRACTOR SHALL CONTACT THE LOCAL POWER COMPANY, PROVIDE ALLLABOR & MATERIALS, AND PAY ALL COST & FEES FOR A COMPLETE NEW ELECTRICALSERVICE.ELECTRICAL CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENTREQUIRED FOR THE COMPLETION AND OPERATION ALL SYSTEMS IN THIS SECTION OFWORK.SUBMIT LIGHTING AND POWER DISTRIBUTION EQUIPMENT PRODUCT DATA FORAPPROVAL PRIOR TO PURCHASE.COORDINATE ELECTRICAL WORK WITH OTHER TRADES TO AVOID CONFLICTS.COORDINATION MUST OCCUR PRIOR TO PURCHASING OR INSTALLING EQUIPMENT ANDMATERIALS.ALL INTERIOR LIGHTING SHALL BE CONTROLLED BY DUAL TECHNOLOGY OCCUPANCYSENSORS AT ALL AREAS EXCEPT THOSE CONTROLLED BY THE OWNER'S DIMMER RACKS.(THE OWNER'S DIMMER RACK CONTROLS MUST INCLUDE A TIMER.)ALL EXTERIOR LIGHTING TO BE CONTROLLED BY TIMER AND PHOTOCELL.ALL CONDUCTORS SHALL BE COPPER.SIZE ALL CIRCUITS AND FEEDERS FOR LOADS AND LENGTHS. DO NOT EXCEED A 3%VOLTAGE DROP.INSTALL EMT CONDUIT IN ALL OPEN AREAS AND WHERE EXPOSED.LABEL ALL DISTRIBUTION EQUIPMENT, PANELS, DISCONNECTS, AND CIRCUITS.ELECTRICAL GENERAL NOTESP1P1ELP8(6) D1(2) D1D1D1D1(6) P4(4) T3SOFFSOFFELRBLANK COVEROVER SCONCE(9) P4Connection Pointe Christian Church - Carmel SDSSDSS4S4S 4
S 3 S 3
S D
SDSSS DSSDSSSS3S3SSSSS
SDSDS
S
S D
S3S3S DSDSDS
S 3
S3S D
S
SDSSSSDSS3SDS
D
S
D
S
DS3
SS
D
S
D
SDSSS3
S3SP8S
S 3
S 3
S REFER A.V.L. DRAWINGS FOR TV AND MULTI-PURPOSE ROOM LIGHTING AND POWER. POWERTHOSE DEVICES FROM PANEL "B: (CONFIRMACTUAL LOADS AND CIRCUITS REQUIRED)ALL LIGHTING THIS AREA,ENCLOSED BY DASHED LINES,SHALL BE ON CIRCUIT B41ALL LIGHTING THIS AREA PERA.V.L. DRAWINGS AND FROMPANEL "B".ALL LIGHTING THIS AREA,ENCLOSED BY DASHED LINES,SHALL BE ON CIRCUIT B35ALL LIGHTING THIS AREA,ENCLOSED BY DASHED LINES,SHALL BE ON CIRCUIT A4ALL LIGHTING THIS AREA,ENCLOSED BY DASHED LINES,SHALL BE ON CIRCUIT B43ALL LIGHTING THIS AREA,ENCLOSED BY DASHED LINES,SHALL BE ON CIRCUIT B39ALL LIGHTING THIS AREA,ENCLOSED BY DASHED LINES,SHALL BE ON CIRCUIT B37ALL LIGHTING THIS AREA,ENCLOSED BY DASHED LINES,SHALL BE ON CIRCUIT A2ALL LIGHTING THIS AREA,ENCLOSED BY DASHED LINES,SHALL BE ON CIRCUIT A6ALL LIGHTING THIS AREA PERA.V.L. DRAWINGS AND FROMPANEL "LTG".P1 16 1600SMALL CYLINDER LED PENDANT DOWN LIGHTP1P1P1P1ALL MEZZANINE LIGHTINGSHALL BE ON CIRCUIT A8ALL MEZZANINE LIGHTINGSHALL BE ON CIRCUIT B45