HomeMy WebLinkAboutElevationsEXTERIOR PAINT LEGENDP-1MARKMANUFACTURERSHERWIN-WILLIAMSCOLORDORIAN GRAYSAMPLE IMAGESW 7017P-2SHERWIN-WILLIAMSGAUNTLET GRAYSW 7017P-3SHERWIN-WILLIAMSEIDER WHITESW 7014P-4SHERWIN-WILLIAMSSALTY DOGSW 9177P-5SHERWIN-WILLIAMSCAVIARSW 6990EXTERIOR SIGNAGE 1EXTERIOR SIGNAGE 2A30101SCALE: 1/4" = 1'-0" BUILDING SECTION 18'-0"FREESTANDING PRECAST CONCRETEPANELS WITH HORIZONTAL JOINTSAT 24" O.C. PAINTED (P-3)4'-0"16'-0"±4'-0"MINIMUM R-7.5 E.I.F.S. ON 1/2" DENS-GLASS GOLD SHEATHINGON METAL STUD FRAMING WITH MINIMUM R-13 BATT INSULATIONAND 5/8" GYPSUM BOARD INTERIOR ON VAPOR RETARDERPAINTED (P-2)(TYPICAL INFILL AT SANCTUARY EXTERIOROPENINGS)(F)(F)OWNER REVIEW: _________ _______________INITIALSDATERevisions:DateDrawn ByChecked ByBYRUMARCHITECTSCertified ByOwnership, Use, Copy, andScope DrawingsDistribution of DocumentsCThe concept, design, and drawings for thisproject are instruments of the architect's service,are owned by the architect, and are for usesolely with respect to this project. The drawingsshall not be used on other projects or additionsto this project without written permission anddue compensation to the architect. The drawingsshall not be copied or distributed withoutauthorization from the architect, architect'spartner, or authorized representative.These drawings indicate the general scope ofthe project in terms of design, concept, thedimensions of building, the major elements and,in some cases, the structural, mechanical,and/or electrical systems. The drawings do notnecessarily indicate or describe all that'srequired for full completion of the work. On thebasis of the general scope indicated ordescribed, provide all that's required for theproper execution and completion of the work.11728 Arborhill DriveZionsville, Indiana 46077317-574-8808Copyright 2023Project No.23003A301EXT.ELEV'S &BLDG. SECTION12-21-2023CADJWBSpecially commissioned by T&W Church Solutions, and used under license.A30102SCALE: 3/32" = 1'-0" EAST EXTERIOR ELEVATION Carmel, Indiana
2599 East 98th Street 01A30124'-0"
8'-0"4'-0"72'-0"4'-0"5'-4"(TYP.)WINDOWS AND CLEAR ANODIZED ALUMINUM STOREFRONT ANDENTRANCES WITH TEMPERED, GRAY TINTED, LOW-E GLAZINGMEETING INDIANA ENERGY CODE (ALL UPPER SECTIONS OF WINDOWSTO BE OPERABLE CASEMENTS WITH SCREENS UNLESS INDICATED BY"(F)")NEW STOREFRONT IN EXISTING OPENINGSBEYOND (SEE NOTE RIGHT OF THIS ONE)PREFINISHED METAL EDGE (DEEPBLACK FINISH)E.I.F.S. MONUMENTAL ENTRYFACADE WITH HORIZONTAL JOINTSAT 2'-0" O.C. TO MATCH PAINT (P-4)EXISTING E.I.F.S. TOMATCH PAINT (P-1)PAINT EXISTINGBRICK WALL (P-4)A30103SCALE: 3/32" = 1'-0" NORTH EXTERIOR ELEVATION A30105SCALE: 3/32" = 1'-0" WEST EXTERIOR ELEVATION A30104SCALE: 3/32" = 1'-0" SOUTH EXTERIOR ELEVATION A30106SCALE: 3/32" = 1'-0" NORTH EXTERIOR ELEVATION / SECTION CLEAR ANODIZED ALUMINUM WITH GRAYTINTED INSULATED GLAZING HERE AND OTHEREND OF MEZZANINE, NOT SHOWNMEZZANINE GREENROOM, RESTROOM, AND A.V.L. EQUIPMENTA.V.L. ANDBALCONYPLATFORMSANCTUARY MAIN SEATINGLOBBYPAINT ALL EXPOSED BRICKWALL (P-1)BACK OF NEW PRECAST CONCRETEWALL BEYOND PAINTED (P-3)BACK OF NEW E.I.F.S. MONUMENTAL ENTRYFACADE BEYOND TO MATCH PAINT (P-4)REPAIR AND / ORREPLACE SOFFITS ASNEEDED (TYPICAL)PAINT TO MATCH WALLTOOTH-IN FACE BRICKWHERE H.V.A.C. UNITREMOVED PAINTED (P-2)TOOTH-IN FACE BRICKWHERE H.V.A.C. UNITREMOVED PAINTED(P-2)(TYPICAL)TOOTH-IN FACE BRICKWHERE H.V.A.C. UNITSREMOVED PAINTED (P-1)(TYPICAL)VESTIBULEVIDEO SCREENBY OTHERSNEW ENTRY CANOPY WITH TPOROOFING (TYP.) (SEESTRUCTURAL)CEILING AND WALL TREATMENTSPER INTERIOR DESIGNERDRYWALL BULKHEAD ON2-1/2" METAL STUDSDIFFUSERS PERMECHANICALDUCTWORK PERMECHANICAL121/410'-0"14'-0"3'-0"10'-0"2"3'-8" ATCLOSESTCLEAR ANODIZEDALUMINUM STORE FRONTAND ENTRANCES WITHTEMPERED, INSULTED,TINTED, LOW-E GLAZINGTO MEET INDIANAENERGY CODECLEAR ANODIZEDALUMINUM STORE FRONTAND ENTRANCES WITHTEMPERED GLAZINGADHERED MEMBRANE ROOFON 3/4" PLYWOODPREFINISHED METAL EDGEALL SIDES (DEEP BLACKFINISH)1-1/2" E.I.F.S. WITH V-GROOVES ON1/2" DENS GLASS GOLD SHEATHING(COLOR TO MATCH P-4)6" 18 GAGE (600S-162-43)STUDS AT 16" O.C. WITHBRIDGING AT 48" O.C MAX.2'-0"PREFINISHED METALFLASHINGWHITE TPO (TYP.) ONISOLATION BOARD ON METALDECK (DEEP BLACK FINISH)PREFINISHED METALGUTTER (DEEPBLACK FINISH)PREFINISHED METALDOWNSPOUT (DEEPBLACK FINISH)FRAME ANDCOLUMNS PERSTRUCTURALPAINTED (P-5)FLATWORK PER SITEDRAWINGSADHERED MEMBRANE ROOFON TAPERED INSULATIONON MINIMUM R-20 RIGIDINSULATIONSEE STRUCTURAL±8'-0"3'-6"DIFFUSER OPENINGSPER STRUCTURALSEE STRUCTURALWINDOWS OR CLEAR ANODIZED ALUMINUM STOREFRONT ANDENTRANCES WITH TEMPERED, GRAY TINTED, LOW-E GLAZINGMEETING INDIANA ENERGY CODE (ALL LOWER SECTIONS OFWINDOWS TO BE OPERABLE AWNING) UNLESS NOTED OTHERWISE)WINDOWS AND CLEAR ANODIZED ALUMINUM STOREFRONT ANDENTRANCES WITH TEMPERED, GRAY TINTED, LOW-E GLAZINGMEETING INDIANA ENERGY CODE (ALL UPPER SECTIONS OF WINDOWSTO BE OPERABLE CASEMENTS WITH SCREENS UNLESS INDICATED BY"(F)")PREFINISHED METAL GUTTERAND DOWNSPOUTS (DEEPBLACK FINISH)NEW HORIZONTAL V-GROOVESIN EXISTING E.I.F.S. AT 36" O.C.AT UPPER PORTION OFBUILDING TO MATCH PAINT (P-2)WINDOWS AND CLEAR ANODIZED ALUMINUM STOREFRONT ANDENTRANCES WITH TEMPERED, GRAY TINTED, LOW-E GLAZINGMEETING INDIANA ENERGY CODE (ALL UPPER SECTIONS OF WINDOWSTO BE OPERABLE CASEMENTS WITH SCREENS UNLESS INDICATED BY"(F)")PREFINISHED METALGUTTER ANDDOWNSPOUTS (DEEPBLACK FINISH)PREFINISHED METAL GUTTERAND DOWNSPOUTS (DEEPBLACK FINISH)(F)(F)(F)(F)(F)(F)DRYWALL DUCT ENCLOSURE1'-2"NEW HORIZONTAL V-GROOVESIN EXISTING E.I.F.S. AT 36" O.C.AT UPPER PORTION OFBUILDING TO MATCH PAINT (P-2)REPAIR AND / ORREPLACE SOFFITS ASNEEDED (TYPICAL)TO MATCH WALLREPAIR AND / ORREPLACE SOFFITS ASNEEDED (TYPICAL)PAINT TO MATCH WALLREPAIR AND / OR REPLACESOFFITS AS NEEDED(TYPICAL) PAINT TO MATCHWALLEND WALL FRAMING BEYONDTO BE 8" 18 GAGE (800S-162-43)STUDS AT 12" O.C. WITHBRIDGING AT 48" O.C MAX.1-1/2" E.I.F.S. WITHV-GROOVES ON 1/2" DENSGLASS GOLD SHEATHINGR-13 BATT INSULATIONWITH VAPOR RETARDERAND STEEL STUD FRAMINGPREFINISHED METALEDGE (DEEP BLACKFINISH)DRYWALLCEILINGConnection Pointe Christian Church - Carmel FILL ORIGINAL WINDOW OPENINGS WITH 1-1/2" E.I.F.S. ON 1/2"DENS GLASS GOLD ON 3-5/8" STEEL STUDS, FILLED WITH R-13BATT INSULATION WITH VAPOR RETARDER. INTERIOR TO BEFLUSH WITH EXISTING 5/8" GYPSUM BOARD ON 3-5/8" STEELSTUDS PAINTED (P-2)(TYPICAL)FILL ORIGINAL WINDOW OPENINGS WITH 1-1/2" E.I.F.S.ON 1/2" DENS GLASS GOLD ON 3-5/8" STEEL STUDS,FILLED WITH R-13 BATT INSULATION WITH VAPORRETARDER. INTERIOR TO BE FLUSH WITH EXISTING5/8" GYPSUM BOARD ON 3-5/8" STEEL STUDS. (TYPICAL)SIGHT L
INE FILL ORIGINAL WINDOW OPENINGS WITH 1-1/2" E.I.F.S.ON 1/2" DENS GLASS GOLD ON 3-5/8" STEEL STUDS,FILLED WITH R-13 BATT INSULATION WITH VAPORRETARDER. INTERIOR TO BE FLUSH WITH EXISTING5/8" GYPSUM BOARD ON 3-5/8" STEEL STUDS. (TYPICAL)NEW CANOPY COLUMNSPAINTED (P-5)EXISTING BRICK WALLTO BE PAINTED (P-1)COPING TO BE PAINTED (P-5)PREFINISHED METALGUTTER ANDDOWNSPOUTS (DEEPBLACK FINISH)DOWNSPOUTS ALONG E.I.F.S.TO BE PAINTED TO MATCHEXTERIOR WALL FINISHDOWNSPOUTS ALONG E.I.F.S.TO BE PAINTED TO MATCHEXTERIOR WALL FINISHDOWNSPOUTS ALONG E.I.F.S.TO BE PAINTED TO MATCHEXTERIOR WALL FINISHREPAIR EXISTING E.I.F.S.AND PAINT (P-3)COPING TO BE PAINTED (P-5)NEW CANOPY COLUMNSPAINTED (P-5)SIDE OF EXISTING BRICKWALL BEYOND TO BEPAINTED (P-4)EXISTING BRICK WALLTO BE PAINTED (P-2)EXISTING BRICK WALLTO BE PAINTED (P-4)EXISTING BRICK WALLTO BE PAINTED (P-2)TOOTH-IN FACE BRICKWHERE H.V.A.C. UNITSREMOVED PAINTED (P-2)(TYPICAL)LOCATION OF SIGNAGE 1(SEE EXTERIORSIGNAGE TYP.)LOCATION OF SIGNAGE 2(SEE EXTERIORSIGNAGE TYP.)PAINT EXISTINGBRICK WALL (P-2)LOCATION OF SIGNAGE 1(SEE EXTERIORSIGNAGE TYP.)EXISTING E.I.F.S. TOMATCH PAINT (P-2)EXISTING E.I.F.S. TOMATCH PAINT (P-2)EXISTING E.I.F.S. TOMATCH PAINT (P-1)WHITE TPO (TYP.) ONISOLATION BOARD ON METALDECK (DEEP BLACK FINISH)WHITE TPO (TYP.) ONISOLATION BOARD ON METALDECK (DEEP BLACK FINISH)WHITE TPO (TYP.) ONISOLATION BOARD ONMETAL DECK (DEEPBLACK FINISH)EXISTING E.I.F.S. TOMATCH PAINT (P-1)EXISTING E.I.F.S. TOMATCH PAINT (P-2)NEW ENTRY CANOPY WITHTPO ROOFING (TYP.) (SEESTRUCTURAL)SIGNAGE TO BE METALSTRUCTURE W/ WHITEACRYLIC FACE; ALLLETTERS TO BEREVERSE LITSIGNAGE TO BE METALSTRUCTURE W/ WHITEACRYLIC FACE; ALLLETTERS TO BEREVERSE LITSIGNAGE TO BEMETAL STRUCTUREW/ WHITE ACRYLICFACE; ALL LETTERSTO BE REVERSE LITWINDOWS AND CLEAR ANODIZED ALUMINUM STOREFRONT ANDENTRANCES WITH TEMPERED, GRAY TINTED, LOW-E GLAZINGMEETING INDIANA ENERGY CODE (ALL UPPER SECTIONS OF WINDOWSTO BE OPERABLE CASEMENTS WITH SCREENS UNLESS INDICATED BY"(F)")EXISTING BRICK WALLTO BE PAINTED (P-4)PRECAST WALL TO BEPAINTED (P-3)WINDOWS AND CLEAR ANODIZED ALUMINUM STOREFRONT ANDENTRANCES WITH TEMPERED, GRAY TINTED, LOW-E GLAZINGMEETING INDIANA ENERGY CODE (ALL UPPER SECTIONS OF WINDOWSTO BE OPERABLE CASEMENTS WITH SCREENS UNLESS INDICATED BY"(F)")GUTTERS AND COPING TO BEPAINTED (P-5)