HomeMy WebLinkAboutExterior Elevations-A301_040824EXTERIOR PAINT LEGEND
P-1
MARK MANUFACTURER
SHERWIN-WILLIAMS
COLOR
DORIAN GRAY
SAMPLE IMAGE
SW 7017
P-2 SHERWIN-WILLIAMS GAUNTLET GRAY
SW 7017
P-3 SHERWIN-WILLIAMS EIDER WHITE
SW 7014
P-4 SHERWIN-WILLIAMS SALTY DOG
SW 9177
P-5 SHERWIN-WILLIAMS CAVIAR
SW 6990
EXTERIOR SIGNAGE 1
EXTERIOR SIGNAGE 2
A301
01
SCALE: 1/4" = 1'-0"
BUILDING SECTION 18'-0"FREESTANDING PRECAST CONCRETE
PANELS WITH HORIZONTAL JOINTS
AT 24" O.C. PAINTED (P-3)
4'-0" 16'-0" ±4'-0"
MINIMUM R-7.5 E.I.F.S. ON 1/2" DENS-GLASS GOLD SHEATHING
ON METAL STUD FRAMING WITH MINIMUM R-13 BATT INSULATION
AND 5/8" GYPSUM BOARD INTERIOR ON VAPOR RETARDER
PAINTED (P-2)(TYPICAL INFILL AT SANCTUARY EXTERIOR
OPENINGS)
(F)
(F)
OWNER REVIEW: _________ _______________
INITIALS DATE
Revisions:
Date
Drawn By Checked By
BYRUM
ARCHITECTS
Certified By
Ownership, Use, Copy, and
Scope Drawings
Distribution of Documents
C
The concept, design, and drawings for this
project are instruments of the architect's service,
are owned by the architect, and are for use
solely with respect to this project. The drawings
shall not be used on other projects or additions
to this project without written permission and
due compensation to the architect. The drawings
shall not be copied or distributed without
authorization from the architect, architect's
partner, or authorized representative.
These drawings indicate the general scope of
the project in terms of design, concept, the
dimensions of building, the major elements and,
in some cases, the structural, mechanical,
and/or electrical systems. The drawings do not
necessarily indicate or describe all that's
required for full completion of the work. On the
basis of the general scope indicated or
described, provide all that's required for the
proper execution and completion of the work.
11728 Arborhill Drive
Zionsville, Indiana 46077
317-574-8808
Copyright 2023
Project No.
23003
A301
EXT.ELEV'S &
BLDG. SECTION
12-21-2023
CAD JWB
Specially commissioned by T&W Church Solutions, and used under license.A301
02
SCALE: 3/32" = 1'-0"
EAST EXTERIOR ELEVATION Carmel, Indiana2599 East 98th Street01
A301
24'-0"8'-0"4'-0" 72'-0" 4'-0"
5'-4"
(TYP.)
WINDOWS AND CLEAR ANODIZED ALUMINUM STOREFRONT AND
ENTRANCES WITH TEMPERED, GRAY TINTED, LOW-E GLAZING
MEETING INDIANA ENERGY CODE (ALL UPPER SECTIONS OF WINDOWS
TO BE OPERABLE CASEMENTS WITH SCREENS UNLESS INDICATED BY
"(F)")
NEW STOREFRONT IN EXISTING OPENINGS
BEYOND (SEE NOTE RIGHT OF THIS ONE)
PREFINISHED METAL EDGE (DEEP
BLACK FINISH)
E.I.F.S. MONUMENTAL ENTRY
FACADE WITH HORIZONTAL JOINTS
AT 2'-0" O.C. TO MATCH PAINT (P-4)
EXISTING E.I.F.S. TO
MATCH PAINT (P-1)
PAINT EXISTING
BRICK WALL (P-4)
A301
03
SCALE: 3/32" = 1'-0"
NORTH EXTERIOR ELEVATION
A301
05
SCALE: 3/32" = 1'-0"
WEST EXTERIOR ELEVATION
A301
04
SCALE: 3/32" = 1'-0"
SOUTH EXTERIOR ELEVATION
A301
06
SCALE: 3/32" = 1'-0"
NORTH EXTERIOR ELEVATION / SECTION
CLEAR ANODIZED ALUMINUM WITH GRAY
TINTED INSULATED GLAZING HERE AND OTHER
END OF MEZZANINE, NOT SHOWN
MEZZANINE GREEN
ROOM, RESTROOM, AND
A.V.L. EQUIPMENT
A.V.L. AND
BALCONY
PLATFORM SANCTUARY MAIN SEATING LOBBY
PAINT ALL EXPOSED BRICK
WALL (P-1)
BACK OF NEW PRECAST CONCRETE
WALL BEYOND PAINTED (P-3)
BACK OF NEW E.I.F.S. MONUMENTAL ENTRY
FACADE BEYOND TO MATCH PAINT (P-4)
REPAIR AND / OR
REPLACE SOFFITS AS
NEEDED (TYPICAL)
PAINT TO MATCH WALL
TOOTH-IN FACE BRICK
WHERE H.V.A.C. UNIT
REMOVED PAINTED (P-2)
TOOTH-IN FACE BRICK
WHERE H.V.A.C. UNIT
REMOVED PAINTED
(P-2)(TYPICAL)
TOOTH-IN FACE BRICK
WHERE H.V.A.C. UNITS
REMOVED PAINTED (P-1)
(TYPICAL)
VESTIBULE
VIDEO SCREEN
BY OTHERS
NEW ENTRY CANOPY WITH TPO
ROOFING (TYP.) (SEE
STRUCTURAL)
CEILING AND WALL TREATMENTS
PER INTERIOR DESIGNER
DRYWALL BULKHEAD ON
2-1/2" METAL STUDS
DIFFUSERS PER
MECHANICALDUCTWORK PER
MECHANICAL
12
1/4
10'-0" 14'-0"3'-0" 10'-0"2"
3'-8" AT
CLOSEST
CLEAR ANODIZED
ALUMINUM STORE FRONT
AND ENTRANCES WITH
TEMPERED, INSULTED,
TINTED, LOW-E GLAZING
TO MEET INDIANA
ENERGY CODE
CLEAR ANODIZED
ALUMINUM STORE FRONT
AND ENTRANCES WITH
TEMPERED GLAZING
ADHERED MEMBRANE ROOF
ON 3/4" PLYWOOD
PREFINISHED METAL EDGE
ALL SIDES (DEEP BLACK
FINISH)
1-1/2" E.I.F.S. WITH V-GROOVES ON
1/2" DENS GLASS GOLD SHEATHING
(COLOR TO MATCH P-4)
6" 18 GAGE (600S-162-43)
STUDS AT 16" O.C. WITH
BRIDGING AT 48" O.C MAX.
2'-0"
PREFINISHED METAL
FLASHING
WHITE TPO (TYP.) ON
ISOLATION BOARD ON METAL
DECK (DEEP BLACK FINISH)
PREFINISHED METAL
GUTTER (DEEP
BLACK FINISH)
PREFINISHED METAL
DOWNSPOUT (DEEP
BLACK FINISH)
FRAME AND
COLUMNS PER
STRUCTURAL
PAINTED (P-5)
FLATWORK PER SITE
DRAWINGS
ADHERED MEMBRANE ROOF
ON TAPERED INSULATION
ON MINIMUM R-20 RIGID
INSULATION
SEE STRUCTURAL
±8'-0"3'-6"
DIFFUSER OPENINGS
PER STRUCTURAL
SEE STRUCTURAL
WINDOWS OR CLEAR ANODIZED ALUMINUM STOREFRONT AND
ENTRANCES WITH TEMPERED, GRAY TINTED, LOW-E GLAZING
MEETING INDIANA ENERGY CODE (ALL LOWER SECTIONS OF
WINDOWS TO BE OPERABLE AWNING) UNLESS NOTED OTHERWISE)
WINDOWS AND CLEAR ANODIZED ALUMINUM STOREFRONT AND
ENTRANCES WITH TEMPERED, GRAY TINTED, LOW-E GLAZING
MEETING INDIANA ENERGY CODE (ALL UPPER SECTIONS OF WINDOWS
TO BE OPERABLE CASEMENTS WITH SCREENS UNLESS INDICATED BY
"(F)")
PREFINISHED METAL GUTTER
AND DOWNSPOUTS (DEEP
BLACK FINISH)
NEW HORIZONTAL V-GROOVES
IN EXISTING E.I.F.S. AT 36" O.C.
AT UPPER PORTION OF
BUILDING TO MATCH PAINT (P-2)
WINDOWS AND CLEAR ANODIZED ALUMINUM STOREFRONT AND
ENTRANCES WITH TEMPERED, GRAY TINTED, LOW-E GLAZING
MEETING INDIANA ENERGY CODE (ALL UPPER SECTIONS OF WINDOWS
TO BE OPERABLE CASEMENTS WITH SCREENS UNLESS INDICATED BY
"(F)")
PREFINISHED METAL
GUTTER AND
DOWNSPOUTS (DEEP
BLACK FINISH)
PREFINISHED METAL GUTTER
AND DOWNSPOUTS (DEEP
BLACK FINISH)
(F)
(F)
(F)
(F)
(F) (F)
DRYWALL DUCT ENCLOSURE
1'-2"NEW HORIZONTAL V-GROOVES
IN EXISTING E.I.F.S. AT 36" O.C.
AT UPPER PORTION OF
BUILDING TO MATCH PAINT (P-2)
REPAIR AND / OR
REPLACE SOFFITS AS
NEEDED (TYPICAL)
TO MATCH WALL
REPAIR AND / OR
REPLACE SOFFITS AS
NEEDED (TYPICAL)
PAINT TO MATCH WALL
REPAIR AND / OR REPLACE
SOFFITS AS NEEDED
(TYPICAL) PAINT TO MATCH
WALL
END WALL FRAMING BEYOND
TO BE 8" 18 GAGE (800S-162-43)
STUDS AT 12" O.C. WITH
BRIDGING AT 48" O.C MAX.
1-1/2" E.I.F.S. WITH
V-GROOVES ON 1/2" DENS
GLASS GOLD SHEATHING
R-13 BATT INSULATION
WITH VAPOR RETARDER
AND STEEL STUD FRAMING
PREFINISHED METAL
EDGE (DEEP BLACK
FINISH)
DRYWALL
CEILING
Connection Pointe Christian Church - CarmelFILL ORIGINAL WINDOW OPENINGS WITH 1-1/2" E.I.F.S. ON 1/2"
DENS GLASS GOLD ON 3-5/8" STEEL STUDS, FILLED WITH R-13
BATT INSULATION WITH VAPOR RETARDER. INTERIOR TO BE
FLUSH WITH EXISTING 5/8" GYPSUM BOARD ON 3-5/8" STEEL
STUDS PAINTED (P-2)(TYPICAL)
FILL ORIGINAL WINDOW OPENINGS WITH 1-1/2" E.I.F.S.
ON 1/2" DENS GLASS GOLD ON 3-5/8" STEEL STUDS,
FILLED WITH R-13 BATT INSULATION WITH VAPOR
RETARDER. INTERIOR TO BE FLUSH WITH EXISTING
5/8" GYPSUM BOARD ON 3-5/8" STEEL STUDS. (TYPICAL)
SIGHT
L
I
N
E
FILL ORIGINAL WINDOW OPENINGS WITH 1-1/2" E.I.F.S.
ON 1/2" DENS GLASS GOLD ON 3-5/8" STEEL STUDS,
FILLED WITH R-13 BATT INSULATION WITH VAPOR
RETARDER. INTERIOR TO BE FLUSH WITH EXISTING
5/8" GYPSUM BOARD ON 3-5/8" STEEL STUDS. (TYPICAL)
NEW CANOPY COLUMNS
PAINTED (P-5)EXISTING BRICK WALL
TO BE PAINTED (P-1)
COPING TO BE PAINTED (P-5)
PREFINISHED METAL
GUTTER AND
DOWNSPOUTS (DEEP
BLACK FINISH)
DOWNSPOUTS ALONG E.I.F.S.
TO BE PAINTED TO MATCH
EXTERIOR WALL FINISH
DOWNSPOUTS ALONG E.I.F.S.
TO BE PAINTED TO MATCH
EXTERIOR WALL FINISH
DOWNSPOUTS ALONG E.I.F.S.
TO BE PAINTED TO MATCH
EXTERIOR WALL FINISHREPAIR EXISTING E.I.F.S.
AND PAINT (P-3)
COPING TO BE PAINTED (P-5)
NEW CANOPY COLUMNS
PAINTED (P-5)
SIDE OF EXISTING BRICK
WALL BEYOND TO BE
PAINTED (P-4)
EXISTING BRICK WALL
TO BE PAINTED (P-2)
EXISTING BRICK WALL
TO BE PAINTED (P-4)
EXISTING BRICK WALL
TO BE PAINTED (P-2)
TOOTH-IN FACE BRICK
WHERE H.V.A.C. UNITS
REMOVED PAINTED (P-2)
(TYPICAL)
LOCATION OF SIGNAGE 1
(SEE EXTERIOR
SIGNAGE TYP.)
LOCATION OF SIGNAGE 2
(SEE EXTERIOR
SIGNAGE TYP.)
PAINT EXISTING
BRICK WALL (P-2)
LOCATION OF SIGNAGE 1
(SEE EXTERIOR
SIGNAGE TYP.)
EXISTING E.I.F.S.
TO MATCH PAINT
(P-2)
EXISTING E.I.F.S. TO
MATCH PAINT (P-2)
EXISTING E.I.F.S. TO
MATCH PAINT (P-1)
WHITE TPO (TYP.) ON
ISOLATION BOARD ON METAL
DECK (DEEP BLACK FINISH)
WHITE TPO (TYP.) ON
ISOLATION BOARD ON METAL
DECK (DEEP BLACK FINISH)
WHITE TPO (TYP.) ON
ISOLATION BOARD ON
METAL DECK (DEEP
BLACK FINISH)
EXISTING E.I.F.S. TO
MATCH PAINT (P-1)
EXISTING E.I.F.S. TO
MATCH PAINT (P-2)
NEW ENTRY CANOPY WITH
TPO ROOFING (TYP.) (SEE
STRUCTURAL)
SIGNAGE TO BE METAL
STRUCTURE W/ WHITE
ACRYLIC FACE; ALL
LETTERS TO BE
REVERSE LIT
SIGNAGE TO BE METAL
STRUCTURE W/ WHITE
ACRYLIC FACE; ALL
LETTERS TO BE
REVERSE LIT
SIGNAGE TO BE
METAL STRUCTURE
W/ WHITE ACRYLIC
FACE; ALL LETTERS
TO BE REVERSE LIT
WINDOWS AND CLEAR ANODIZED ALUMINUM STOREFRONT AND
ENTRANCES WITH TEMPERED, GRAY TINTED, LOW-E GLAZING
MEETING INDIANA ENERGY CODE (ALL UPPER SECTIONS OF WINDOWS
TO BE OPERABLE CASEMENTS WITH SCREENS UNLESS INDICATED BY
"(F)")
EXISTING BRICK WALL
TO BE PAINTED (P-4)
PRECAST WALL TO BE
PAINTED (P-3)
WINDOWS AND CLEAR ANODIZED ALUMINUM STOREFRONT AND
ENTRANCES WITH TEMPERED, GRAY TINTED, LOW-E GLAZING
MEETING INDIANA ENERGY CODE (ALL UPPER SECTIONS OF WINDOWS
TO BE OPERABLE CASEMENTS WITH SCREENS UNLESS INDICATED BY
"(F)")
GUTTERS AND COPING TO BE
PAINTED (P-5)
18'-8"20'-5"35' 14' -0" 4/16/2024