HomeMy WebLinkAboutS100 FISHING PIER STRUCTURAL NOTESGENERAL 1. THESE GENERAL NOTES REPRESENT AND/OR SUMMARIZE KEY PROJECT INFORMATION FOR THE DRAWING USER'S CONVENIENCE. HOWEVER, ALL CONSTRUCTION DOCUMENTS SHOULD BE REVIEWED FOR FURTHER DETAILS AND REQUIREMENTS. 2. WHERE REFERENCE IS MADE TO VARIOUS CODES, STANDARDS, AND TEST STANDARDS FOR MATERIALS, SUCH STANDARDS SHALL BE AS SPECIFIED IN SECTION CODES AND STANDARDS. 3. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. WHERE NO SPECIFIC DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. 4. TYPICAL DETAILS ARE NOT CUT ON DRAWINGS, BUT APPLY UNLESS NOTED OTHERWISE. 5. WHERE ANY DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE MORE STRINGENT REQUIREMENT SHALL GOVERN. 6. ELEVATIONS SHOWN ARE RELATIVE TO THE F.F.E. (i.e., PROPOSED DECK SURFACE = 0' - 0"). FOR PROJECT DIMENSIONAL CONTROL, SEE CIVIL DRAWINGS. 7. WORK THESE DRAWINGS WITH THOSE PREPARED BY OTHER DISCIPLINES: CIVIL –CIVIL & ENVIRONMENTAL CONSULTANTS. DO NOT PENETRATE ANY STRUCTURAL ELEMENTS (BEAMS, COLUMNS, WALLS, SLABS, STEEL DECKS, ETC.) WITHOUT PRIOR WRITTEN APPROVAL OF STRUCTURAL ENGINEER UNLESS SPECIFIC PENETRATION DETAILS ARE SHOWN ON DRAWINGS. 8. THIS PROJECT IS WITHIN THE JURISDICTION OF THE CARMEL, INDIANA. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL BUILDING PERMITS AND SCHEDULING/ACCOMMODATING ALL REQUIRED INSPECTIONS PERTAINING TO THE BUILDING PERMITS. 9. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE, WHICH IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE CONSTRUCTION IS FULLY COMPLETED. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND ENSURE THE STABILITY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, TEMPORARY BRACING, ETC. THAT MAY BE NECESSARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER COMPLETION OF THE PROJECT. 10. THIS ENGINEER DOES NOT HAVE CONTROL OR CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ACTS OR OMISSIONS OF THE CONTRACTOR, THEIR SUBCONTRACTORS, AND ANY OTHER PERSONS PERFORMING ANY OF THE WORK, OR FOR THE FAILURE OF THESE PERSONS TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 11. THE CONTRACTOR IS RESPONSIBLE FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK THAT CONFORMS WITH THE REGULATIONS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) SAFETY AND HEALTH STANDARDS FOR THE CONSTRUCTION INDUSTRY. 12. CONSTRUCTION MATERIAL SHALL BE SPREAD OUT IN SUCH A MANNER TO NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT OF THE AREA. 13. OPTIONS AND ALTERNATES ARE FOR THE CONTRACTOR'S CONVENIENCE. IF AN OPTION OR ALTERNATE IS CHOSEN, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CHANGES NECESSARY AND SHALL COORDINATE ALL DETAILS. 14. THE FOLLOWING ABBREVIATIONS MAY BE USED ON THE DRAWINGS: CODES & STANDARDS 1. IBC 2012: INTERNATIONAL BUILDING CODE [INDIANA BUILDING CODE 2014 EDITION] 2. ASCE 7-10: MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES 3. SP-66-04: ACI DETAILING MANUAL 4. ACI 117-10: SPECIFICATION FOR TOLERANCES FOR CONCRETE 5. ACI 301-10: STANDARD SPECIFICATION FOR STRUCTURAL CONCRETE 6. ACI 318-11: BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE 7. ACI 347-10: STANDARD SPECIFICATION FOR FORMWORK FOR CONCRETE 8. CRSI: MANUAL OF STANDARD PRACTICE 9. NDS-12: NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION 10. ASTM A615: STANDARD SPECIFICATION FOR DEFORMED AND PLAIN CARBON STEEL BARS FOR CONCRETE REINFORCEMENT 11. OSHA: OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS A ROD ANCHOR ROD A/E ARCHITECT & ENGINEER AB ANCHOR BOLT ACI AMERICAN CONCRETE INSTITUTE ADDL ADDITIONAL AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION ALT ALTERNATE APPROX APPROXIMATE APVD APPROVED ARCH ARCHITECTURAL/ARCHITECT ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS ASTM AMERICAN SOCIETY FOR TESTING MATERIALS AWS AMERICAN WELDING SOCIETY B/0 BOTTOM OF BM BEAM BOT BOTTOM BRG BEARING BTWN BETWEEN C/C CENTER TO CENTER CHKD CHECKED CHKRD CHECKERED CIP CAST-IN-PLACE CONCRETE CJ CONSTRUCTION/CONTROL JOINT CL CENTERLINE CLR CLEAR/CLEARANCE COL COLUMN CONC CONCRETE CONN CONNECTION CONT CONTINUOUS COORD COORDINATE CP CONCRETE PIER CRSI CONCRETE REINFORCING STEEL INSTITUTE CTR CENTER CTRD CENTERED DBA DEFORMED BAR ANCHOR DBL DOUBLE DEG DEGREES DET DETAIL DIA DIAMETER DIAG DIAGONAL DIR DIRECTION DL DEAD LOAD DP DRILLED PIER DWG DRAWING EA EACH EF EACH FACE EL ELEVATION ENGR ENGINEER EOD EDGE OF DECK EOR ENGINEER OF RECORD EOS EDGE OF SLAB EQ EQUAL EW EACH WAY EXP EXPANSION EXT EXTERIOR FDN FOUNDATION FF FINISHED FLOOR FFE FINISHED FLOOR ELEVATION FG FINISHED GRADE FIN FINISH FLR FLOOR FND FOUNDATION FRMG FRAMING FT FOOT FTG FOOTING GA GAGE, GAUGE GALV GALVANIZED (HOT DIP) GL GIRT LINE GR GUARDRAIL GRTG GRATING (H) HORIZONTAL BEAM ORIENTATION HCA HEADED CONCRETE ANCHOR HDR HEADER HGR HANGER HORIZ HORIZONTAL HP HIGH POINT HR HANDRAIL HSB HIGH STRENGTH BOLT IF INSIDE FACE IBC INTERNATIONAL BUILDING CODE ICC INTERNATIONAL CODE COUNCIL ICF INSULATED CONCRETE FORM ID INSIDE DIAMETER IN INCH INT INTERIOR JST JOIST JT JOINT K KIP(S) KB KNEE BRACE KSF KIPS PER SQUARE FOOT KSI KIPS PER SQUARE INCH LB POUND LF LINEAR FEET LL LIVE LOAD LOC LOCATION LONG LONGITUDINAL LP LOW POINT LSH LONG SLOTTED HOLE M MOMENT MAX MAXIMUM MC MOMENT CONNECTION MCJ MASONRY CONTROL JOINT MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MTL METAL N/A NOT APPLICABLE NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OPNG OPENING OPP OPPOSITE OSH OVERSIZED HOLE PCF POUNDS PER CUBIC FOOT PE PROFESSIONAL ENGINEER PENE PENETRATION PERIM PERIMETER PL PLATE PLF POUNDS PER LINEAR FOOT PREFAB PREFABRICATED PROJ PROJECTION PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT POINT QTY QUANTITY R RADIUS RCP REINFORCED CONCRETE PIPE RD ROOF DRAIN REF REFERENCE REINF REINFORCING REQD REQUIRED RET RETURN REV REVISION RO ROUGH OPENING SCHED SCHEDULE SECT SECTION SHT SHEET SIM SIMILARL SJI STEEL JOIST INSTITUTE SL SLOPE SPCS SPACES SPEC(S) SPECIFICATION(S) SQ SQUARE SR SAG ROD SS STAINLESS STEEL SSH SHORT SLOTTED HOLE STD STANDARD STIF STIFFENER STL STEEL STRUCT STRUCTURAL SYM SYMMETRICAL T/ TOP OF T&B TOP AND BOTTOM T&G TONGUE AND GROOVE THK THICK THRU THROUGH TJ TRUSS JOIST TP TOE PLATE TRANS TRANSVERSE TYP TYPICAL UL UNDERWRITERS LABORATORIES UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD W/ WITH W/O WITHOUT WCJ WALL CONTROL JOINT WP WORKING POINT WS WATERSTOP WWR WELDED WIRE REINFORCEMENT YD YARD ABBREVIATIONS DESIGN CRITERIA RISK CATEGORY II 1. WOOD FISHING PLATFORM A. DEAD LOAD 10 PSF B. LIVE LOAD 100 PSF 2. SNOW LOADS A. GROUND SNOW LOAD 20 PSF B. EXPOSURE FACTOR 1.0 C. THERMAL FACTOR 1.0 3. WIND LOADS A. ULTIMATE WIND SPEED (3-SECOND GUST) 105 MILES PER HOUR B. EXPOSURE C C. BUILDING CLASSIFICATION OTHER STRUCTURE 4. SEISMIC LOADS A. SITE CLASS D (ASSUMED) B. SEISMIC DESIGN CATEGORY B a. SS 0.146 b. S1 0.081 c. SDS 0.156 d. SD1 0.13 C. SEISMIC FORCE RESISTING SYSTEM SEE TABLE SFRS D. ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE FOUNDATION NOTES 1. FOUNDATION DESIGN WAS COMPLETED WITHOUT THE BENEFIT OF GEOTECHNICAL INVESTIGATIONS. ASSUMPTIONS WERE MADE FOR SOIL PROPERTIES AS NOTED BELOW: A. BEARING CAPACITY: 1,500 PSF (NET/ALLOWABLE) B. DENSITY OF SOIL & BACKFILL: 120 PCF C. FROST DEPTH: 3 FT D. ACTIVE LATERAL SOIL UNIT WEIGHT: 110 PCF E. PASSIVE LATERAL SOIL UNIT WEIGHT: 120 PCF F. INTERNAL ANGLE OF FRICTION 32 DEGREES 2. THE DESIGN HAS BEEN COMPLETE UNDER THE ASSUMPTION THAT THE TIMBER PILES CAN BE DRIVEN SUFFICIENTLY AND END BEARING CAPACITY CAN BE OBTAINED. THIS SHOULD BE CONFIRMED BY A GEOTECHNICAL ENGINEER PRIOR TO CONSTRUCTION. IF IT IS DETERMINED THAT THIS METHOD IS NOT FEASIBLE, NOTIFY THE EOR FOR REVISIONS TO THE FOUNDATION DESIGN. 3. CONTRACTOR IS RESPONSIBLE FOR ENGAGING A GEOTECHNICAL TESTING AGENCY TO VERIFY ASSUMED GEOTECHNICAL PARAMETERS. IF DETERMINED GEOTECHNICAL PARAMETERS ARE FOUND TO DIFFER FROM THOSE ASSUMED, CONTACT ENGINEER OF RECORD FOR REVISED CONSTRUCTION DRAWINGS PRIOR TO CONSTRUCTION. 4. IT IS OUR RECOMMENDATION THAT A GEOTECHNICAL ENGINEER BE RETAINED BY THE OWNER TO PROVIDE OBSERVATION AND TESTING SERVICES DURING THE GRADING AND FOUNDATION PHASE OF CONSTRUCTION. INSPECTION AND TESTING REPORTS TO BE SUBMITTED TO THE ENGINEER OF RECORD. PREPARATION OF SUBGRADES SHALL BE AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. 5. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE WHETHER OR NOT ADDITIONAL GEOTECHNICAL INFORMATION IS REQUIRED AND TO PROVIDE SUCH INFORMATION AS HE/SHE DEEMS NECESSARY. 6. PRIOR TO PLACING CONCRETE FOR SEAL SLABS OR FOUNDATIONS, THE SUBSOIL CONDITIONS SHALL BE CHECKED BY GEOTECHNICAL ENGINEERS REPRESENTATIVE FOR COMPLIANCE WITH THE PROJECT GEOTECHNICAL REPORT AND SPECIFICATIONS. 7. ABUTMENT WALL HAS BEEN DESIGNED TO BE RESTRAINED MY THE FISHING PLATFORM FRAMING. NO BACKFILLING ON THE ABUTMENT WALL SHALL TAKE PLACE UNTIL CONCRETE HAS ATTAINED DESIGN STRENGTH AND EITHER THE FRAMING IS IN PLACE OR ADEQUATE BRACING IS PROVIDED. CONTRACTOR IS RESPONSIBLE FOR DESIGN AND INSTALLATION OF WALL BRACING FOR WALLS THAT ARE BACKFILLED PRIOR TO CONSTRUCTION OF TOP RESTRAINT. 8. PRIOR TO PLACEMENT OF CONCRETE, CONTRACTOR SHALL CONFIRM ALL FOUNDATION EMBED ITEMS - PIPES SLEEVES, STEEL PLATES, INSERTS, ETC., ARE IN PLACE. WOOD FRAMING 1. WOOD FRAMING WORK SHALL FOLLOW THE PRACTICES AND STANDARDS SPECIFIED IN SECTION CODES AND STANDARDS. 2. ALL WOOD SHALL BE PRESSURE TREATED IN ACCORDANCE WITH THE MANUAL OF RECOMMENDED PRACTICE OF THE AMERICAN WOOD PRESERVERS' ASSOCIATION STANDARDS (AWPA). 3. NAIL FASTENING PATTERN SHALL ADHERE TO THE MOST STRINGENT OF THE NAIL SCHEDULE LISTED ON THE CONSTRUCTION DOCUMENTS AND IN THE REFERENCED BUILDING CODE (CHAPTER 23), UNLESS NOTED OTHERWISE. 4. FASTENERS SHALL BE COMMON NAILS, UNLESS NOTED OTHERWISE. PROVIDE GALVANIZED OR STAINLESS STEEL FASTENERS WHERE EXPOSED, IN ALL SHEAR WALLS, IN ALL PRESSURE TREATED LUMBER, AND AS INDICATED IN THE DRAWINGS/SPECIFICATIONS. 5. ALL CAST-IN-PLACE AND POST-INSTALLED ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S WRITTEN RECOMMENDATIONS. 6. SUBSTITUTIONS MAY BE CONSIDERED FOR THE ANCHORS. SUBMIT SUBSTITUTION REQUEST WITH PUBLISHED DESIGN LOADS AND METHODS FOR ATTACHMENT. SUBSTITUTION REQUESTS MUST BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO THE START OF CONSTRUCTION. 7. SAWN LUMBER JOISTS MAY BE NOTCHED AT ENDS A MAXIMUM OF ONE-FOURTH OF THE DEPTH OF THE JOIST. CUTTING OR NOTCHING THE INTERIOR OF JOISTS IS NOT ALLOWED WITHOUT WRITTEN APPROVAL FROM THE ENGINEER. 8. SAWN LUMBER JOISTS AND WALL STUDS MAY BE BORED FOR ELECTRICAL/MECHANICAL PENETRATIONS, PROVIDED THAT THE BORE HOLE IS IN THE MIDDLE THIRD OF THE JOIST/STUD AND IS NO LARGER THAN THE SMALLER OF ONE THIRD OF THE JOIST/STUD DEPTH. NO BORE HOLES/NOTCHES MAY BE WITHIN 6 INCHES OF THE NEXT ADJACENT BORE HOLE/NOTCH. 9. ALL COLUMNS, POSTS, AND STUDS SHALL HAVE FULL END BEARING, UNLESS NOTED OTHERWISE. 10. STRUCTURAL BOLTS SHALL CONFORM TO ANSI/ASME STANDARD B18.2.1-1981. HOLES SHALL BE DRILLED NOT MORE THAN 1/16" LARGER THAN BOLT DIAMETER. 11. COMMON NAILS SHALL CONFORM TO ASTM F1607. WHERE BORED HOLES ARE PROVIDED TO PREVENT SPLITTING OF WOOD, THE DIAMETER OF THE BORED HOLE SHALL NOT EXCEED SEVENTY FIVE PERCENT (75%) OF THE NAIL OR SPIKE DIAMETER. TOE NAILS SHALL BE DRIVEN AT AN ANGLE 30° FROM THE FACE OF ATTACHED MEMBER AND STARTED ONE-THIRD (1/3) THE LENGTH OF THE WOOD FRAMING CONNECTORS. 12. CONNECTOR MODEL NUMBERS REFERENCED ON THE CONSTRUCTION DOCUMENTS ARE MANUFACTURED BY SIMPSON STRONG-TIE. SUBSTITUTIONS ARE ACCEPTABLE WITH THE WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. UNLESS NOTED OTHERWISE, INSTALL THE SIZE AND QUANTITY OF CONNECTORS PRESCRIBED FOR THE SPECIFIC CONNECTION TYPE IN ACCORDANCE WITH THE MOST RECENT MANUFACTURER'S CATALOG. FINISH ON ALL CONNECTORS SHALL BE GALVANIZED. ADDITIONAL PROTECTION SHALL BE USED WHEN EXPOSED TO PRESSURE TREATED LUMBER PER MANUFACTURER RECOMMENDATIONS. 13. ALL STRUCTURAL SAWN LUMBER FRAMING MEMBERS SHALL MEET THE FOLLOWING DESIGN SPECIFICATIONS LISTED IN THE TABLE BELOW IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION" (NDS). MEMBER TYPE E MODULUS OF ELASTICITY (PSI) Fb FLEXURAL STRESS (PSI) Ft TENSION STRESS (PSI) Fc COMPRESSION PAR TO GRAIN (PSI) 2X12 MEMBERS (NO.1 SOUTHERN PINE)1,600,000 1,000 650 1,400 Fc COMPRESSION PERP TO GRAIN (PSI) 565 2X8 MEMBERS (NO.2 SOUTHERN PINE)550 1,350565 2X6 MEMBERS (NO.2 SOUTHERN PINE)600 1,400565 Fv HORIZONTAL SHEAR PAR TO GRAIN (PSI) 175 925 1,000 175 175 1,400,000 1,400,000 2X4 MEMBERS (NO.2 SOUTHERN PINE)675 1,4505651,100 1751,400,000 2X10 MEMBERS (NO.1 SOUTHERN PINE)1,400,000 800 475 1,300565 175 STRUCTURAL CONCRETE 1. CONCRETE WORK SHALL FOLLOW THE PRACTICES AND STANDARDS SPECIFIED IN SECTION CODES AND STANDARDS. 2. CONCRETE PROPERTIES: A. ALL CONCRETE SHALL CONFORM TO ASTM C94 B. ALL AGGREGATES SHALL CONFORM TO ASTM C33 (NORMAL-WEIGHT) & ACI 302.1 C. ALL CONCRETE SHALL BE CURED IN CONFORMANCE WITH ACI 301 D. ALL CONCRETE FORMWORK SHALL CONFORM WITH ACI 347 3. ADDITION OF WATER TO THE BATCH FOR MATERIAL WITH INSUFFICIENT SLUMP WILL NOT BE PERMITTED, UNLESS THE SUPPLIER HAS SPECIFICALLY WITHHELD WATER FROM THE BATCH AT THE PLANT. IN SUCH CASE, THE MIX DESIGN AND TRUCK TICKET MUST CLEARLY STATE THE MAXIMUM AMOUNT OF WATER THAT CAN BE ADDED TO THE BATCH ON SITE. IN NO CASE SHALL THE DESIGN WATER TO CEMENTITIOUS MATERIAL RATIO BE EXCEEDED. 4. AGGREGATES DETERMINED TO BE ALKALI-CARBONATE REACTIVE (ACR), IN ACCORDANCE WITH ASTM C1778, ARE NOT PERMITTED. 5. CONTRACTOR TO SUBMIT ALL PROPOSED CONCRETE ADMIXTURES TO EOR FOR APPROVAL. 6. CONTRACTOR AND REDI-MIX SUPPLIER SHALL SELECT A TARGET SLUMP FOR THE POINT OF DELIVERY FOR CONCRETE MIXTURES USED FOR THIS PROJECT. SELECTED TARGET SLUMP SHALL NOT EXCEED 9 INCHES. CONCRETE SHALL NOT SHOW VISIBLE SIGNS OF SEGREGATION. THE TARGET SLUMP INDICATED ON THE SUBMITTAL SHALL BE USED AS THE BASIS FOR ACCEPTANCE DURING THE PROJECT. DETERMINE THE SLUMP BY ASTM C143/C143M. SLUMP TOLERANCES SHALL BE IN ACCORDANCE WITH ACI 117. 7. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED TO BE VIBRATED ONLY AROUND UNDER-FLOOR DUCTS, SLAB EDGES, REINFORCING, KEYS, ETC. MECHANICALLY VIBRATE ONLY THE TOP 5 FEET OF DRILLED PIER CONCRETE. REVIBRATE TOP OF DRILLED PIER 15 MINUTES AFTER PLACING CONCRETE. 8. WHERE SPECIFIED, VERTICAL CONCRETE SURFACES ARE TO BE FORMED. 9. ALL EXPOSED CONCRETE CORNERS (BOTH VERTICAL & HORIZONTAL) SHALL HAVE A 3/4" CHAMFER OR ROUNDED TOOLED EDGE. 10. THE REQUIREMENTS OF MECHANICAL, ELECTRICAL AND PLUMBING FOR EMBEDDED ITEMS INCLUDING PIPE, CONDUIT, EMBEDDED STEEL, AND BOLTS ARE TO BE CHECKED PRIOR TO EACH CONCRETE POUR. VERIFY ALL ANCHOR BOLT LOCATIONS AND EQUIPMENT OPENINGS AGAINST CERTIFIED VENDOR DRAWINGS. 11. ALL CONCRETE SHALL CURE A MINIMUM OF 7 DAYS AFTER POURING, AND SHALL REMAIN UNLOADED UNTIL CONCRETE HAS REACHED 80% OF THE 28 DAY DESIGN STRENGTH, UNLESS APPROVED BY THE ENGINEER OF RECORD. 12. UNLESS OTHERWISE SPECIFIED, CONCRETE TEMPERATURE AS DELIVERED SHALL NOT EXCEED 95 DEGREES FAHRENHEIT NOR BE LESS THAN 55 DEGREES FAHRENHEIT FOR SECTION SIZE <12", 50 DEGREES FAHRENHEIT FOR 12" - 36". TEMPERATURE OF CONCRETE AS PLACED SHALL NOT EXCEED THESE VALUES BY MORE THAN 20 DEGREES FAHRENHEIT. CONCRETE MIX REQUIREMENTS CONCRETE TYPE 28 DAY COMPRESSIVE STRENGTH (f'c, PSI) AIR CONTENT (+/- 1.5%) (AE=AIR ENTRAINED) MAX W/C RATIO MAX NOM AGG SIZE (IN) CEMENT TYPE FLYASH % (OF TOTAL CEMENT) EXPOSURE CLASSES 0.45 10-206% (AE)I/II4,000FOOTINGS AND STEM WALLS 3/4 F2, S0, W1, C1 REINFORCING STEEL 1. REINFORCING STEEL SHALL FOLLOW THE PRACTICES AND STANDARDS SPECIFIED IN SECTION CODES AND STANDARDS. 2. TYPICAL REINFORCING BAR STRENGTHS A. REINFORCING (NON-WELDABLE) ASTM A615, DEFORMED Fy= 60 KSI (420 MPa) B. REINFORCING (WELDABLE) ASTM A706, DEFORMED Fy= 60 KSI (420 MPa) C. WELDED WIRE REINFORCEMENT ASTM A1064 Fy = 75 KSI (520 MPa) 3. CONCRETE COVER FOR REINFORCEMENT SHALL CONFORM TO THE REQUIREMENTS OF ACI 318 OR ACI 350, UNLESS OTHERWISE NOTED. 4. DETAILING, FABRICATION, SUPPORT, AND PLACING OF ALL BARS SHALL BE PER CRSI SPECIFICATIONS/HANDBOOKS AND THE LATEST ACI CODES AND DETAILING MANUALS. 5. ALL REINFORCING SHALL BE HELD SECURELY IN POSITION WITH STANDARD ACCESSORIES IN CONCRETE. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. 6. REINFORCING BAR SPACINGS GIVEN ARE MAXIMUM ON CENTERS. 7. ALL REINFORCING TO BE WELDED SHALL BE WELDED IN ACCORDANCE WITH AWS D1.4. NO TACK WELDING OF REINFORCING BARS IS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE BY ENGINEER OF RECORD. 8. REINFORCING BAR HOOKS AND BENDS SHALL BE ACI STANDARD DIMENSIONS, UNLESS NOTED OTHERWISE. 9. REINFORCING BARS SHALL NOT BE BENT OR STRAIGHTENED IN A MANNER THAT WILL DAMAGE THE MATERIAL. BARS WITH KINKS OR IMPROPER BENDS SHALL NOT BE USED. NO BARS PARTIALLY EMBEDDED IN CONCRETE SHALL BE FIELD BENT, EXCEPT AS SHOWN ON THE DRAWINGS OR AS PERMITTED BY THE ENGINEER. 10. NO REINFORCING STEEL SHALL BE FIELD BENT WITHOUT THE APPROVAL OF THE ENGINEER OF RECORD. FIELD BENDING OF PLAIN REINFORCEMENT, IF PERMITTED, SHALL BE PERFORMED USING AN APPROVED AND APPROPRIATE SIZED PORTABLE HYDRAULIC DEVICE THAT MAKES ACI STANDARD RADIUS BENDS. NO OTHER FIELD BENDING METHOD SHALL BE PERMITTED. 11. REINFORCING LAP SPLICES IN CONCRETE SHALL BE PER TYPICAL DETAILS UNLESS NOTED OTHERWISE. ALL SPLICE LOCATIONS ARE SUBJECT TO APPROVAL. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT CORNERS AND INTERSECTIONS OF FOOTINGS AND WALLS. 12. ALL SPLICING OF REINFORCING BARS SHALL BE DONE BY LAPPING UNLESS OTHERWISE APPROVED. BARS SPLICED BY NON CONTACT LAP SPLICES IN FLEXURAL MEMBERS SHALL NOT BE SPACED TRANSVERSELY FARTHER APART THAN ONE-FIFTH THE REQUIRED SPLICE LENGTH NOR 6 INCHES. 13. LAP SPLICE LENGTHS FOR DEFORMED BARS SHALL BE ACI 318 CLASS B TENSION LAP SPLICES UNLESS OTHERWISE NOTED ON DESIGN DRAWINGS. 14. LAP SPLICES FOR ADJACENT BARS SHALL BE STAGGERED. STAGGERED SPLICE REQUIREMENTS DO NOT APPLY TO BEAMS AND COLUMNS. 15. ALL SPLICES NOT DETAILED ON DESIGN DRAWINGS SHALL BE TAKEN AS TENSION LAP SPLICES. 16. LAP IN WELDED WIRE REINFORCEMENT SHALL BE MADE SO THAT THE OVERLAP MEASURED BETWEEN THE OUTERMOST CROSS WIRES OF EACH FABRIC SHEET IS NOT LESS THAN THE SPACING OF CROSS WIRES PLUS TWO INCHES. 17. PROVIDE DOWELS IN FOUNDATIONS THE SAME SIZE AND SPACING AS VERTICAL WALL REINFORCING. DOWELS TO HAVE A FULL TENSION LAP SPLICE WITH THE WALL REINFORCING, UNLESS NOTED OTHERWISE. 18. WELDED WIRE REINFORCEMENT SHALL BE FLAT SHEETS AND NOT FROM A ROLLED BUNDLE. ADJACENT EDGES SHALL OVERLAP A MINIMUM OF 8". PLACEMENT SHALL BE AS NOTED AND SHALL BE SUPPORTED SUCH THAT NO UNDUE DEFLECTION OR MOVEMENT WILL OCCUR FROM THE PLACEMENT OF CONCRETE OR THE WEIGHT OF PERSONNEL. 19. DIMENSIONS GIVEN FOR BENT OR HOOKED BARS ARE OUT TO OUT. 20. PROVIDE TWO LONG DIAGONAL BARS IN TOP FACE OF ALL REENTRANT CORNERS IN SLABS UNLESS NOTED OTHERWISE. 21. ALL REINFORCING BARS AT REENTRANT CORNERS SHALL EXTEND FOR THE FULL BAR DEVELOPMENT LENGTH PAST THE CORNERS UNLESS NOTED. REINFORCING CLEAR COVER TABLE TYPE CONCRETE CLEAR COVER (IN) PERMANENTLY EXPOSED TO OR CAST AGAINST EARTH 3 EXPOSED TO EARTH OR WEATHER (#5 OR SMALLER)1 1/2 2 1 1 1/2 EXPOSED TO EARTH OR WEATHER (#6 OR LARGER) NOT EXPOSED TO EARTH OR WEATHER (#11 OR SMALLER) NOT EXPOSED TO EARTH OR WEATHER (#12 OR LARGER) CONCRETE DEVELOPMENT/LAP SPLICE SCHEDULE (f'c = 3 KSI) BAR SIZE DEVELOPMENT LENGTH (IN) 4 22 33 29 43 BAR TYPE 1*BAR TYPE 2* LAP SPLICE LENGTH, CLASS B (IN) BAR TYPE 1*BAR TYPE 2* 5 28 42 37 55 6 33 50 43 65 7 48 72 63 94 8 55 83 72 108 9 62 93 81 121 + + *BAR TYPE 1 - CLEAR SPACING OF BARS BEING DEVELOPED OR LAP SPLICED NOT LESS THAN Db, CONCRETE COVER NOT LESS THAN Db, AND STIRRUPS OR TIES THROUGHOUT Ld NOT LESS THAN THE CODE MINIMUM. BAR TYPE 2 - OTHER CASES +WHERE HORIZONTAL REINFORCEMENT IS PLACED SUCH THAT MORE THAN 12 INCHES OF FRESH CONCRETE IS CAST BELOW THE DEVELOPMENT LENGTH OR SPLICE, INCREASE THE LENGTHS SHOWN BY A FACTOR OF 1.3. 1. POST-INSTALLED ANCHORS SYSTEMS SHALL COMPLY WITH THE LATEST REVISION OF ICC-ES ACCEPTANCE CRITERIA AND HAVE A VALID ICC-ES REPORT IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE. 2. ANCHORS HAVE BEEN DESIGNED ASSUMING HAMMER DRILLED HOLES, DRY CONCRETE, AND CRACKED CONCRETE CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR UTILIZING APPROPRIATE METHODOLOGY TO MEET THESE DESIGN ASSUMPTIONS. 3. ANCHORS ARE NOT TO BE INSTALLED UNTIL CONCRETE OR GROUT HAS REACHED ITS DESIGN STRENGTH, AND ADHESIVE ANCHORS SHALL BE INSTALLED IN CONCRETE HAVING CURED FOR A MINIMUM OF 21 DAYS. 4. FOR ANCHOR EMBEDMENT, SEE DRAWINGS OR TYPICAL DETAIL. USE EMBEDMENT RECOMMENDED BY MANUFACTURER WHERE NO EMBEDMENT IS SHOWN. 5. MANUFACTURER'S INSTALLATION TRAINING AND CERTIFICATION IS REQUIRED ON ALL POST-INSTALLED ANCHORS FOR ANCHOR INSTALLER. TRAINING IS TO BE APPROPRIATELY TIMED TO MEET THE NEEDS OF THE PROJECT. INSTALL ANCHORS PER THE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS (MPII). 6. NO EXISTING REINFORCING OR PRE-STRESSING STRANDS SHALL BE CUT WHEN INSTALLING ANCHORS INTO EXISTING CONCRETE COLUMNS, BEAMS, WALLS, OR SLABS WITHOUT APPROVAL BY THE ENGINEER OF RECORD ON A CASE BY CASE BASIS. 7. ANCHORS SHALL BE INSTALLED USING A HAMMER DRILL WITH CARBIDE BIT AND AN AUTOMATIC SHUT-OFF DEVICE DESIGNED TO STOP DRILLING IF THE BIT COMES INTO CONTACT WITH REINFORCING STEEL. 8. NOTIFY ENGINEER TO PROVIDE ASSISTANCE WHEN THE DRILL BIT HITS REBAR TO AVOID FURTHER DAMAGE TO THE CONCRETE STRUCTURE. 9. INSTALLATION OF CHEMICAL BOND ADHESIVE ANCHORS SHALL BE SUBJECT TO REQUIREMENTS OF MANUFACTURER'S WRITTEN PROCEDURES. SEE MANUFACTURER'S ICC-ESR REPORTS FOR INSTALLATION PROCEDURE AND COMPLETE INSTRUCTIONS. 10. WHEN PREPARING THE ANCHOR HOLE, FOLLOW THE STEPS AS DIRECTED IN THE SETTING INSTRUCTIONS BOOKLET SUPPLIED WITH THE PRODUCT OR SEE ICC-ESR REPORTS FOR PREPARATION REQUIREMENTS. INSPECTORS MUST INSPECT THE HOLE TO INSURE BORE HOLE IS CLEAN AND FREE OF DEBRIS. 11. CHEMICAL ADHESIVE ANCHORS SHALL BE ALLOWED TO ADEQUATELY SET PRIOR TO LOADING THE ANCHORS. 12. SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO USE. CONTRACTOR SHALL PROVIDE CALCULATIONS DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERFORMANCE VALUES OF THE SPECIFIED PRODUCT. SUBSTITUTIONS WILL BE EVALUATED BY THEIR HAVING AN ICC-ESR SHOWING COMPLIANCE WITH THE RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE, INSTALLATION CATEGORY, AND AVAILABILITY OF COMPREHENSIVE INSTALLATION INSTRUCTIONS. ADHESIVE ANCHOR EVALUATION WILL ALSO CONSIDER CREEP, IN-SERVICE TEMPERATURE AND INSTALLATION TEMPERATURE. 13. CONTACT MANUFACTURER'S ENGINEER OR TECHNICAL SERVICES REPRESENTATIVE WITH ANY POST INSTALLED ANCHOR QUESTIONS. a. POST-INSTALLED ANCHORAGE SHALL BE AS SPECIFIED ON DRAWINGS. POST-INSTALLED ANCHORS: 8 A B 34567 12 C D E F G H 8 34567 12 A B C D E F G H REVISION RECORDSHEET OFDATE:DWG SCALE:DRAWN BY:CHECKED BY:APPROVED BY:PROJECT NO:DRAWING NO.:2704 Cherokee Farm Way • Suite 101 • Knoxville, TN 37920Ph: 865.977.9997 - Fax: 865.977.9919www.cecinc.comP:\310-000\311-804\-CADD\Revit\311-804_Structural_CENTRAL_R24.rvtNTSREI REAL ESTATE SERVICES, LLCFISHING PIER DESIGN11335 N. MICHIGAN ROADCARMEL, INDIANA 46077STRUCTURAL NOTESCRSRTJRTJ311-804JANUARY 2024S100 1 5NO DATE DESCRIPTION0 1/23/24 ISSUE FOR BID 1/23/24