HomeMy WebLinkAboutWall Types- A1.00SILL WALL TYPE 6B/S/X1NEW 1 HOUR DEMISING WALL -SEE PLAN FOR LOCATIONS.6' METAL STUDS @ 16" O.C. W/ R-19 BATTINSULATION20 GAUGE W/ 1 3/8" FLANGE [600S137-33]1 LAYER OF 5/8" TYPE 'X' GWB COMPLIANTWITH FIRE RATING, UL DES U419.ALL WALLS TO BE TAPES, SANDED, ANDPREPARED FOR PRIMER.FIRE STOP - EXTEND TODECK AS REQUIREDHEADFIRE TREATED WOODBLOCK AS REQUIREDEXISTING METAL DECKEXISTING ROOFCONSTRUCTIONPENETRATIONFIRE STOPPROVIDE FIRE STOPPING ATALL WALL PENETRATIONS.FIRE STOPFIRE STOP PACKINGFIRE STOP PACKING3" = 1'-0"DEMISING WALL DETAIL - SILL1AA1.003" = 1'-0"DEMISING WALL DETAIL - PENETRATION1CA1.003" = 1'-0"DEMISING WALL DETAIL - HEAD1FA1.00FIRE STOP - EXTEND TODECK AS REQUIREDFIRE TREATED WOODBLOCK AS REQUIREDEXISTING METAL DECKEXISTING ROOFCONSTRUCTIONFIRE STOP PACKING3" = 1'-0"DEMISING WALL DETAIL - HEAD @ ROOF JOIST6CA1.00WALL TYPE 6B/S/X1NEW 1 HOUR DEMISING WALL -SEE PLAN FOR LOCATIONS.6' METAL STUDS @ 16" O.C.W/ R-19 BATT INSULATION20 GAUGE W/ 1 3/8" FLANGE[600S137-33]1 LAYER OF 5/8" TYPE 'X' GWBCOMPLIANT WITH FIRE RATING,UL DES U419.ALL WALLS TO BE TAPES,SANDED, AND PREPAREDFOR PRIMER.EXISTING K-BAR JOISTCONNECT AS REQUIREDWHILE MAINTAININGSEALED FIRE SEPARATIONAS REQUIRED FORCONSTRUCTION OF 1 HR WALLClay TerraceBuilding "D" Demise14400 Clay Terrace Blvd., Ste 165,Carmel, IN 46032IN2305712/22/23CONSTRUCTION DOCUMENTSCOPYRIGHT © 2024 LUMINAUT, INC. - 05/09/2024 - 1:45 PM - L:\IN23057 - Clay Terrace Tenant Demise_Carmel, IN\11 Drawings\CTa_0100 Wall Types.dwg ABCDEFGHJKL151413121110987654321151413121110987654321ABCDEFGHJKL1100 Sycamore Street, Suite 200Cincinnati, Ohio 45202 - Ph: 513.984.1070702 N. Capitol AvenueIndianapolis, Indiana 46204Ph: 317.636.3980www.luminaut.comATTENTION:·WALLS THAT EXTEND TO IRREGULAR DECK SHALL HAVE FLUTES STUFFED WITH FIRE SAFING TO MAINTAINFIRE, SMOKE AND/OR SOUND RATING - WHERE TRACK IS PARALLEL TO DECK FLUTES, METAL STUD CONTRACTOR/SUB-CONTRACTOR SHALL PROVIDECONTINUOUS 12GA. PLATE THAT SPANS FLUTE, FILLFLUTE WITH FIRESAFING. WHERE GYPSUM BOARD AND DECK WILL BE EXPOSED, CONTRACTOR/SUB-CONTRACTOR SHALL 'NOTCH' GYPSUM BOARD TO FOLLOW PROFILE OF DECK FLUTES (U.N.O.).·PENETRATIONS THROUGH RATED WALL CONSTRUCTION SHALL BE FIRE STOPPED AT A LEVEL 'EQUAL TO' OR 'GREATER THAN' THE WALL BEINGPENETRATED. FIRE STOPPING SHALL BE INSTALLED ACCORDING TO U.L. DIRECTORY - VOL. II PENETRATIONS -- ARCHITECT HAS ENDEAVORED TOIDENTIFY COMMON FIRE STOP PENETRATIONS WITHIN THIS DOCUMENT SET.·PROVIDE CONT. TRACK AT TOP OF ALL WALLS THAT ONLY EXTEND TO A FINISHED CEILING SO AS TO ANCHORTOP EDGE OF GYPSUM BOARD AND PROVIDE FIRE STOP AT TOP OF WALL CAVITY TO PREVENT CONTINUOUS'OPEN' SPACE FROM CEILING CAVITY TO WALL CAVITY.·WHERE RATED WALL CONSTRUCTION ALSO SERVES AS AN ACOUSTICAL BARRIER, THEN THE PERIMETER FIRE STOPPING SHALL ACT AS·THE ACOUSTICAL SEALANT. MINIMUM FIRE STOP CONDITION SHALL BE THE USE OFUSG FIRE COMPOUND (OR EQUAL).·WHERE WALLS ARE INDICATED TO HAVE A STC RATING BUT ARE NOT FIRE RATED, CONTRACTOR/SUB-CONTRACTOR SHALL PROVIDE CONTINUOUS ACOUSTICALSEALANT ALONG EACH SIDE OF WALL CONSTRUCTION AT THE BOTTOM, ENDS, AND ANY PENETRATIONS THROUGH THE GYPSUM BOARD.-- REFER ALSO TO DETAIL 3/A0.03 THIS SHEET.·ALL WALL ASSEMBLIES EXTEND TO FLOOR SLAB OR ROOF DECK, U.N.O. BY WALL TYPE MODIFIERS ABOVE. ALL PARTITIONS NOTEXTENDING TO DECK SHALL BE BRACED WITH DIAGONAL KICKERS AT 4'-0" O.C. ALTERNATING DIRECTION WHEN UNBRACED WALL LENGTH EXCEEDS 10'-0"·MINERAL FIBER SOUND ATTENUATION FIRE BLANKET MAY NOT BE SUBSTITUTED WHEN INDICATED AS PART OF A FIRE OR STC RATED WALL CONSTRUCTION.·WHERE MINERAL FIBER SOUND ATTENUATION FIRE BLANKET OR STANDARD SOUND ATTENUATION BATT INSULATION IS INDICATED, FRICTION FIT BLANKETBETWEEN STUDS - FILL ENTIRE STUD CAVITY FROM FLOOR TO CEILING.·WHERE DISSIMILAR WALL TYPES ABUT, OFFSET STUDS TO ALLOW FINISH LAYER OF GYPSUM BOARD TO ALIGN SMOOTHLY. JOINT BETWEEN GYPSUM BOARDSHEETS SHALL BE OFFSET SO AS NOT TO ALIGN WITH CHANGE OF STUDS.·PROVIDE A 'SILL GASKET SEAL' BETWEEN STUD AND ADJACENT EXTERIOR CONCRETE, PRECAST, ALUMN. OR STONE WALLS TO ACT AS THERMAL BREAK.·PROVIDE BRIDGING AT ALL WALLS WHERE GYPSUM BOARD SHEATHING IS NOT CONTINUOUS ON EACH SIDE OF STUD. SPACING SHALL NOT EXCEED 4'-0"O.C.VERTICALLY. BRACE FURRED WALLS AT 4'-0" O.C. VERTICALLY.·PROVIDE MIN. DOUBLE STUDS EACH SIDE OF OPENING AT ALL DOOR LOCATIONS, (U.N.O.) NOTE: STUDS AT THESE LOCATIONS SHALL BE A MIN. OF 20ga·PROVIDE ALL APPROPRIATE GYPSUM BOARD TRIM PIECES AT ALL OUTSIDE CORNERS, TERMINATIONS, EDGES, ETC. - NO J-BEADS MAY BE USED UNLESSSPECIFICALLY INDICATED ON DRAWINGS (USE "L" EDGE BEAD)·TAPE ALL SEAMS, EDGES, PENETRATIONS, TEARS IN ANY VAPOR BARRIER - USE MANUFACTURER RECOMMENDED TAPE TO ENSURE/MAINTAIN A CONTINUOUSVAPOR BARRIER.·CONTRACTOR SHALL PROVIDE (AS PART OF BASE BID) BLOCKING FOR ENTIRE PROJECT FOR ALL ELEMENTS INDICATED, INFERRED, IMPLIED OR OTHERWISEUNDERSTOOD AS REQUIRING BLOCKING DUE TO COMMON CONSTRUCTION PRACTICES·INTERIOR METAL STUD WALL SHOP DRAWINGS MUST BE SUBMITTED TO ARCHITECT FOR REVIEW. SHOP DRAWINGS SHALL INCLUDE PRODUCT SPECIFICINFORMATION FOR EACH WALL TYPE USED ON THE PROJECT. IN ADDITION TO THE MANUFACTURE'S STANDARD PRODUCT LITERATURE, THE SUBMITTAL SHALLINCLUDE ONE 8-1/2"X11" SHEET FOR EACH WALL TYPE. THIS SHEET MUST HAVE A SKETCH SHOWING WALL CONSTRUCTION (SECTION OR PLAN) AND IDENTIFYTHE SPECIFIC MATERIALS USED, SIZES, SPACING, MAXIMUM SPAN, ETC. IT MUST ALSO INCLUDE THE WALL TYPE IDENTIFIER. RATED WALLS SHALL ALSOINCLUDE THE UL DESIGN FOR THE SPECIFIC PRODUCT(S) BEING USED AS WELL AS A COPY OF THE SPECIFIC UL DESIGN FOR THAT WALL CONSTRUCTION FROMTHE UL DIRECTORY. PLEASE BE AWARE, THE UL DESIGNS REFERENCED ON THIS SHEET ARE FOR WALLS CONSTRUCTED WITH USG GYPSUM PRODUCTS ONLY.EACH GYPSUM BOARD MANUFACTURER HAS THEIR OWN SPECIFIC UL DESIGN WHICH HAS BEEN TESTED FOR THEIR PRODUCT(S) -CONTRACTOR/SUB-CONTRACTOR IS PERMITTED TO UTILIZE ANY 'APPROVED EQUAL' GYPSUM BOARD PRODUCTS BUT MUST TAKE RESPONSIBILITY TO MATCHTHE REFERENCED UL DESIGNS ON THIS SHEET AND PROVIDE RATED CONSTRUCTION EQUAL OR BETTER THAN THAT INDICATED ON THE PLANS (X1) OR (X2).IF THERE ARE ANY CONCERNS OR QUESTIONS, PLEASE NOTIFY ARCHITECT.·WALL CONSTRUCTION, UL RATINGS, STUD GAUGE AND SPACING INDICATED WITHIN THE WALL TYPES ON THIS SHEET ARE BASED ON THE USG STUD SPANTABLES PUBLISHED IN THEIR ONLINE CONSTRUCTION HANDBOOK. WALL SYSTEMS USED BY THE CONTRACTOR/SUB-CONTRACTOR SHALL MEET, OR EXCEED,THE SPAN CAPABILITIES INDICATED WITHIN THE USG SPAN TABLES. THE METAL STUD CONTRACTOR/SUB-CONTRACTOR SHALL USE THE DEFLECTIONCRITERIA OF L/240 (5PSF TYPICAL, 7.5PSF ELEVATOR SHAFTS) FOR TYPICAL GYPSUM BOARD WALL CONSTRUCTION WHEN DETERMINING THE MAXIMUMSTUD SPAN. WHERE CERAMIC TILE IS INSTALLED OVER THE WALL CONSTRUCTION, THEN USE L/360 TO DETERMINE THE MAXIMUM SPAN OF STUD.IF AFTER REVIEWING THE SPAN CAPABILITIES OF THE METAL STUDS BEING USED FOR THIS PROJECT, THE METAL STUD CONTRACTOR/SUB-CONTRACTORSHALL ADJUST ANY OF THE FOLLOWING TO ACHIEVE SPAN DISTANCE:··INCREASE STUD GAUGE OR FLANGE SIZE (RATED & UNRATED WALLS)··DECREASE STUD SPACING(RATED & UNRATED WALLS)··ADD COLD ROLLED CHANELS TO STUDS - 48"O.C.(RATED & UNRATED WALLS)··ADD DIAGONAL BRACING ABOVE CELING - 48"O.C.(UNRATED WALLS ONLY)WHERE METAL WALL STUDS ARE RIGIDLY BRACED AT, OR BELOW, THEIR MAXIMUM SPAN WITH A CEILING AND/OR DIAGONAL BRACING (48"O.C.) THEN THESTUD/WALL'S OVERALL HEIGHT MAY BE INCREASED BY 50%. THIS INCREASE MAY NOT BE USED FOR FIRE RATED WALL CONSTRUCTION.PENETRATIONS & FIRE STOPPING Wall Type Construction Notes:WALL TYPE MODIFIER-REFER TO LEGENDTYPICAL WALL TYPETAGFRAMING DEPTHWALL TYPERATED WALLS:RATED WALL CONSTRUCTION INDICATED WITH RATING IN HOURSWall Type Legend and Modifiers:NOTE:WHEN A MODIFIER ISAPPLIED TO THE BASEWALL CONSTRUCTION, THEMODIFIER INDICATESPROPERTIES THAT TAKEPRECEDENCE OVER THEBASE CONSTRUCTIONX#3d3dX#S1.FIRE RATING INDICATED IN PARTITION TYPE SCHEDULE ONLY REQUIRED WHERE DESIGNATED ON PLANS. REFER TO WALL TYPES DIRECTLY FORWALL TYPE MODIFIERS.REFER TO STUD MFR.(1) LAYER 5/8" TYPE 'X' GYPSUM BOARD ON EACH SIDE OF 6" 25ga. METALSTUDS AT 16" o.c.-PROVIDE 6" GLASS FIBER ATTENUATION BLANKETS - SECURE W/ IMPALINGCLIPS OR AS NECESSARY6b7 1/4"49 EST.1-HRSU419·ALL REFERENCES TO CONTRACTOR ON THIS SHEET SHALL REFER TO THE INTERIOR METAL STUD AND DRYWALL CONTRACTOR.·THERE ARE TWO BASIC CONCEPTS REGARDING RATED WALL CONSTRUCTION THAT WILL HELP THE CONTRACTOR UNDERSTAND THIS SHEET.1. CRITICAL: RATED WALLS IDENTIFIED ON THIS SHEET ARE DESCRIBED IN THEIR BASIC FORM ONLY. IT IS THE CONTRACTOR/SUB-CONTRACTOR'SRESPONSIBILITY TO HAVE HAVE ACCESS TO THE MOST CURRENT UL FIRE RESISTIVE DIRECTORY INFORMATION (VOLUMES I & II). THEY MUST REFER TO,AND USE VOLUME 1 TO:DETERMINE THE COMPLETE REQUIREMENTS FOR THE FIRE RESISTIVE CONSTRUCTION IDENTIFIED WITHIN THIS SHEET. THIS INFORMATION WILL THEN BEUSED TO PROPERLY CONSTRUCT THE ASSEMBLY AND ENSURE THE FINAL FIRE RESISTIVE WALL CONSTRUCTION IS FULLY COMPLIANT WITH THE FIRERESISTIVE ASSEMBLY DETAILED IN THE UL FIRE RESISTIVE DIRECTORY.2. MANY RATED WALL ASSEMBLIES WILL PROVIDE A FIRE RESISTIVE RATING THAT EXCEEDS WHAT IS REQUIRED BY THE BUILDING CODE. SOMETIMES THESTC REQUIREMENTS FOR A GIVEN ROOM/AREA WILL REQUIRE 'HEAVIER' WALL CONSTRUCTION TO ACHIEVE THE DESIRED STC. THEREFORE WHATAMOUNTS TO A '2-HOUR' WALL MAY ONLY NEED TO PROVIDE '1-HOUR' PROTECTION PER CODE. THIS 'DISCREPANCY' IS MADE CLEAR BY THE USE OFTHE 'WALL TYPE MODIFIER' ATTACHED TO ALL RATED WALL TYPES SYMBOLS ON THE PLAN. THIS MODIFIER IDENTIFIES THE REQUIRED FIRE RESISTIVEPER THE BUILDING CODE AND TO WHAT LEVEL OPENINGS/PENETRATIONS MUST BE PROTECTED. A1.00WALL TYPESJMCJMCAs NotedCTa_0100 Wall TypesAXO. DETAIL @ TYP. BLOCKINGNOT TO SCALE9AA1.00TERMINATE ALL BLOCKING AT METAL STUD -DONOT CANTILEVER BLOCKING TRACK, EXTEND TONEXT STUD6" 20ga TRACK - COPE FLANGES AT STUD LOCATIONS-FASTEN TO STUDS W/ (2) MIN. SCREWS EA. STUD--USE AT LOCATIONS:HC GRAB BARS, CABINETRY, SHOWER SEATS ANDTUB SEATS!ATTENTION! MUST BE ABLE TO WITHSTAND A MIN. OF250lb FORCE IN A VERTICAL OR HORIZONTALAPPLICATION6" 20ga. METAL STRAP BLOCKING-FASTEN TO STUDS W/ (2) MIN. SCREWS EA. STUD--USE AT LOCATIONS:TOILET ACCESSORIES, BED HEADBOARDS, ETC.STANDARD METAL WALL STUD-TYPICAL- 3 5/8" 25ga. --REFER TO PLANSYESNO2x FRT BLOCKING - COPE VERT. STUD FLANGES ASINDICATED -FASTEN TO STUDS W/ (2) MIN. SCREWS EA.STUD--USE AT LOCATIONS:HC GRAB BARS, CABINETRY, SHOWER SEATS ANDTUB SEATS!ATTENTION! MUST BE ABLE TO WITHSTAND A MIN. OF250lb FORCE IN A VERTICAL OR HORIZONTALAPPLICATIONNOTE:INTERIOR STUD WALL CONTRACTOR/SUB-CONTRACTOR SHALL PROVIDE ACOUSTICAL SEALANT ATALL INTERIOR WALLS REQUIRED TO HAVE SOUND ATTENTION INSULATION - SEAL ENTIRE PERIMETEROF WALL (HEAD, SILL, ENDS) AND PENETRATIONS (PENETRATION SEALANT - ACOUSTICAL ORINTUMESCENT - BY PENETRATING CONTRACTOR/SUB-CONTRACTOR).WALL TYPES WITHIN THE PROJECT WILL VARY FROM THE CONDITIONS SHOWN, ADJUST SEALANT ASNECESSARY.MINIMUM NUMBER OF SEALANT BEADS REGARDLESS OF LAYOUT (BASED ON WALL STUD SIZE): (2) BEADS: 1-5/8" & 2-1/2" STUDS (3) BEADS: 3-5/8" STUDS AND LARGERPROVIDE 3 1/2" SOUND BATT IN CEILING CAVITY AT THE"CEILING-TO-WALL" INTERSECTION WHERE WALL TERMINATES ATFINISHED CEILING, EXTEND CEILING BATT Min. OF 4'-0" EACH DIRECTIONOF WALLCONT. BEADS OF SMOKE AND ORACOUSTICAL SEALANT - FILL CAVITYWHERE GYP. BD. IS HELD AWAY FROMADJACENT CONSTRUCTIONRATED WALLNON-RATED WALLNON-RATEDWALL TO CEILINGWALL CONSTRUCTION PER PLANSSTRUCTURECTa_0100 Wall TypesFull ScaleTYP. ACCOUSTICAL SEALANT DETAIL9DA1.00CTa_0100 Wall TypesAXO. DETAL @ TYP. DOOR FRAMINGNOT TO SCALE9HA1.00NOTE:TOP METAL STUD TRACK - ANCHOR AS NECESSARY ORAS INDICATED IN THE CONSTRUCTION DOCUMENTSOPTION -1DOOR ROUGH OPENING SHALL BE FRAMED USING AMINIMUM OF 20 Ga. FRAMING AS INDICATED BY HATCH--WHEN USING WOOD BLOCKING, FRAMING MAY REMAINAS 25 Ga. FRAMINGOPTION -2CONT. 2x FRT BLOCKING USED AT DOOR ROUGHOPENINGSCONTRACTOR HAS OPTION TO FRAME DOORROUGH OPENINGS USING ONE OF THE TWONOTED OPTIONSSOUND ATTENUATION:FILL STUD CAVITY WITH MIN. 3 1/2" SOUND ATTENUATION BLANKETS OR PER STC REQUIREMENTS--EXTEND FULL HEIGHT OF STUD WALL AS INDICATED ON PLANS6" StudsINSULATION TO BE R-19 MIN.ALL WALLS TO EXTEND TO DECK AS INDICATED AT 1F / A1.00.ALL WALLS TO BE TAPED, SANDED, AND PREPARED FOR PRIMER.