HomeMy WebLinkAbout04020078 Site Plan
Note:
Minimum Front yard - Variable
Minimum Side Yard - 5'
Minimum Aggregate-1(7
Minimum Rear Yard - 20'
&i0i0(1J][jjJj)@@ [i;!J@[J'UIlD
~@OOO@g 11" = ~@'
~
I
oj i'
~g
" 0> oj
'" <D t:i
ua:: a 8
;; ~
~~
~o
z~
-'"
""
H)
"'>-
Flood Hazard Nole:
I
I
1
I
I
I
I 5.3.
1-
'"
"-
~ ~ &
~ g - "
U!~;
x _
r-
"
.
I
I
L
"
~ g
~
".
./"
l ;5
W.
1;j"
.0
wo
~~
"
~
~
15' R.OE
Lot Number 437 lies within that Special Rood Hazard
Zone .X" per the scaled location on the Flood
Insurance Rate Maps for Hamilton County, Indiana
(Community Panel #18057C0205F, dated February 19,
2003).
Nole:
This drawing il baled upon construction plans andfor record drawings
prepared by othe~ and Is not based upon a !leld survey. COOR
Consulting & Land Services, Corp. does not warrant the correctness or
integrity of this Informallon. The contractor/owr1el" ahould verify existing
conditions prior to construction. Any varying field conditlons or any
discrepancy with the information contained hereon should be
immediately reported to COOR Consulting & Land Services, Corp.,
failure to do so would result in the contrllctorlowne~ aeaumption of
liability.
~oors
@@Oll@()j]UlloOll@ I%!r OOOOll@ i0@!lWO@@i0g
@@IY~@lYiIDUD@1liJ
303 WEST MAIN STREET KNIGHTSTOW\l, INDIANA
(888)593-2667 (765)345-5943 FAX.: (765) 345-5692
DATE: 02105/04 JOB #2000-500.437 REVISIONS:
Garage Finish Floor I
1.5 feet above curb
at center of drive.
Gar. FFE = 913.3
1st Fir FFE = 915.3
Bsm! FFE = 905.6
Drive Slope = 2.8%
LOT # 437
::1:11,690 SF
PAD 913.0 PER PLAN
.IT
!RID
"-
22.66
2.00'
&
"
"'
w
~
'"
~
'"
SAN MH
Te =911.26
~
Note:
[&KZI = Proposed Grade
- " Drainage Flow
XXX = Existing Grade
KESSLER - ELEV 6C
RIGHT HAND - Partial Bock
FULL BSMT - 9' Walls
3 CAR - Front Entry
\J
ttl~
~~
z-
-'"
" "
>-U
"'>-
;: j
I ffi g
ll. g
U) 0 w
J: ~ 5
S ~ ~
(I) 0:: ~
f---:;
~ &51
:r:
u
...----/
Cone Flatwork Sq. Ft = t1256
Public Walk Sq Ft = :t306
Sod Sq Yd." t313
Seeding Sq Ft = :t5860
The pro pOled construction grades depicted hereon are based upon
Information, proposed grades and/or contou~, taken from the approved
construction plana prepared for this ,subdiviSion. Unless ltated hereon,
no informal/on pertaining 10 but nollimited to, fiuctuating water table
elevations., soil typel or conditions wlthln the building area of said lot,
has been provided or referenced on said plans. With the conatruction 01
a basement, It is recommended that the lowest noar elevation be
constructed at least two (2) reet above any adjoining bodies of water
unless a study of filct' reveals otherwise. Should any ground water be
witnessed during the excavation of said structure, the lowest !loar
elevat!on should be raised at least two (2) feet above the ground water
level and additional cOll8trl.lclion techniques should be irlCOfpOnlted 10
alleviate Mure problems.
SADDLE CREEK
SECTION 12
PC 3, SLIDE 308
INSTR #200300122041
LOT # 437
4282 CHARIOTS WHISPER DRN
WESTFIELD, IN 46074
PLOT PLAN
Prepared For.
tJ2!&j
Pulte Homes of Indiana