HomeMy WebLinkAboutCorrespondence .'. 7172 Graham Road Indianapolis, IN 46250 317 -842-6777 FAX: 317-841-4798 www.cripe.biz . Architecture Construction Administration . Engineering Geographic Information Services Landscape Architecture Land Planning Land Surveying Rea' Estate Consulting Transportation Engineering =~"." .......'i...... ~J ~L:. ~_;,.;__Jffi:!!l:!~l:f:~;f-~~ April 17, 2006 ". . . ~ Mr. Greg Hoyes, AC Plan Reviewer Hamilton County Surveyor's Office One Hamilton County Square, Suite 188 Noblesville, IN 46060-2230 RE: Response Letter Hamilton County Surveyor's Office Technical Review and Comment -Drainage Review .. Abney Glen Subdivision Dear Mr. Hoyes, Please accept this letter as a formal response to your comment email dated March 15, 2006, regarding our proposed construction plans to the City of Carmel. Response 1: Comment noted. Bonds to be set up by the Developer and the estimate shall be actual construction cost since the plans have been bid. Subdivision Non-enforcement agreement has been submitted previously. Response 2: Comment noted. The plat shall be forwarded with the revised CD's. Response 3: The landscape plans have been revised and are included in the construction documents and a note has been added to the C501 and L- 1.0 sheets in areas where the landscaping is in close proximity to the storm sewer. The note states to coordinate with the Surveyor's Office prior to planting trees. Response 4: Comment noted. Please see revised sheets C501 and C502. The label has been added. Response 5: Comment noted. Please see revised sheets C501, C705, AND C712 for notes and details. Please feel free to contact me at 317-845-7129 if you should have any questions. s~ J11-J~ Christopher M. Wiseman, P.E. PAUL I. CRIPE, INC. cc: Matt Griffin -Carmel DOCD John South -HCSWCD 001 l\\'~'!~v. ~ss,,~ O:\2005\050394\20000\docs\Permits\Comment Ltr _ GHoyes_HCSO _041206.doc -;ci. Amanda Foley -Carmel Engineering Dick Hill -Carmel Engineering Mike McBride -HCHD Greg IIko -CrossRoads Engineers Indiana Land Development Corporation File - CRIPE . l:5:\2biTh\050394\20000\docs\Permlts\Comment Llr_ GHoyes_HCSO _041206.doc IS 001 l\1/<\l11v. /<~~\\\\/< 84/24/2886 17:48 317776~628 bo ~ s F;~ HAMIL TON CO SURVEYOR PAGE 81/Ell ~~:~~~ ~~ @ (]/-VC'':S:~/~''~'~'.)\'~\~ .:~ \' , '. .' . .r:.._. ) "r P.J' ';Y'-' . (.. _~\~.(..,r:- 4~.J ./ J::;.-I-~ ,) (~G.4.-.. ')0. 'J''':' ...-.. .,. . ~ , . .r-- r::/V '--... -- \.-;.. .'Kt't1{(1t/ C. 'Worn, Sumyor (p/i"nt C:P7) 77~4'5 '"FI/:r (3f7) 77~':2.S SlIitr 1$8 Olle .1fnmilfon COllnty .~qllart ./V'/J/IIe.cllilte, ,,,dionn 460S0'22JO April 21, 2006 Mr. Scott Brewer Oeplilrtment of Community service One Civic Square Ca~l~L 46032 ~ Dear Mr. Brewer, Regarding the Abney Glen Subdivision Construction Documents, there Is a landsoape e8$ement shown within the 30 foot Drainage and utiUty Easement (0 and UE). ThIs easement is located on the south edge of the 30 foot D end UE and adjacent to the 30' building setback. The lots that are affected ere limited to Iot9 26 and 36-41. In this case It Is acceptable to Install landscaping within this easement, as weD as. for the 10' landscape easement to over1ap becaU$e our regula~ drain (pipe) Is shifted to the north side of this easement. closer to the Right of Way. I want to add that some notes have been added to the construction documents ensuring the trees shan be planted 15 feet from the centerline of the proPO$8d storm sewer. Note sha" 1'Nd: "Coordlnete with the Surveyor's Office prior to InstaDation of landscaping along 121- Street-. Please feel free to contac;t me at 317-776-8495 if you should have any questions. ~~ Greg R. Hoyes, AC Plan Reviewer ee: Paul Shoopman (via fax) 415-0466 Chris Wiseman, (via fax) 841-4798 File s:~URVEY STAFP\grh\Cannel ~ I.8fI8l3 2OO8\Abn8y Glen\SS___LtI'_0441.o&.doc j 051 ~E)O l D S"p 8 9 RECEIVED MAR 2 7 2006 DOCS \" ,. EL March 20, 2006 JAMES BRAINARD, MAYOR Mr. Chris Wiseman, P.E. Cripe 7172 Graham Road Indianapolis, IN 46250 RE: Abney Glen (formerly Long Branch) Construction Plans-Project Review #2 Dear Mr. Wiseman: The City has received your comment letter and drawings dated March 3, 2006 based upon the City review of February 16,2006. The comments from the City review have been satisfactorily addressed with the following exceptions: COMMENTS As it relates to your responses to items 16, 17, 18, and 27 of the City's letter dated February 16,2006, we are reviewing your responses. Thank you for providing a copy of the commitments. The City's response will be issued as soon as possible. 13. Please indicate and label the right-of-way for 121st Street and Shelbome Road. If the existing right-of-way is less than that prescribed in the thoroughfare plan, the additional right-of-way must be dedicated. 22. Please label the 10-foot multi-use path in the right-of-way across the frontages. Please label as 100foot width. 23. Please indicate a no access easement along each of the 121st Street and Shelbome Road frontages. Please indicate for Shelborne Road properties. 28. Please incorporate the Deparbnent's cover and backfill standard for all storm sewers and for sanitary and water mains and laterals within the right-of-way into the design for the secondary plat. Thank you for adding the notes to Sheets C713 and C806. Please add or edit current trench and backfill details that incorporate these requirements to these same sheets and the water details. 29. There are existing culverts under 121 st Street that must be accommodated by this development's drainage system. Thank you, please confirm with the County and Greg IIko of Crossroad Engineers that this note is addressed. 31. Minimum lane widths for entrances with medians is 16- feet unless a lesser width is approved by the Fire Deparbnent. The total width of the entrance with a median shall not exceed 46-feet. The exit lanes at the 12111 Street/Abney Highland Drive and 12111 Street/Abney Point Drive entrances shall be 16 feet unless the Fire Department is acceptable to 15 feet. 32. Please indicate Abney Glen Drive to be a private street both on the construction drawings and the plat. 33. The granular backfill reference in the profile legend and General Notes 8 and 9 on the utility plan and profile sheets needs to reference the City standards or trench and backfill details that meet the City standards. 34. The multiple crossings and angles of the crossings of Abney Point Drive in the vicinity of Structures 767, 768, 769 and 770 will be problematic in constructing the roadway and achieving adequate compaction of the subgrade. Please limit the number of crossings to two (one for the road inlets and one for the pond outlet), make the crossings perpendicular to the centerline and maximize the distance between the crossings. Please contact Dan Greskamp of this office to DEPARTMENT OF ENGINEERING ONE CMC SQUARE, CARMEL, IN 46032 OFFICE 317.571.2441 FAX 317.571.2439 EMAIL engineering@ci.carmel.in.us : 9 review the need for geogrid or other subgrade stabilization required to properly construct the roadway with the proposed storm lines and other utilities in this area. These comments represent the Department of Engineering's second review of the secondary plat for this project. We request that all responses to our comments be provided in writing. Failure to provide written responses may result in delay of the review process. It is critical that this office be made aware of all modification made on the plans being resubmitted, particularly if any such changes are considered ''new'' or fall outside of our previous reviews. Please provide revised plans indicating all revisions. Please notify us of any changes and specifically state any changes, including changes resulting from Plan Commission, Special Studies or other committee meetings. All bonds and performance guarantees (if required) must be posted prior to Engineering Department approval. Also, Board of Public Works and Safety approval and any other governing agency approvals (if required) must be obtained prior to Engineering Department approval. Please continue to work with Crossroad Engineers to obtain drainage approval from the Department of Engineering. The Department of Engineering reserves the right to provide additional comments based on subsequent reviews. If you have questions, please call me at 571-2441. cc: Matt Griffin, Department of Community Services John Duffy, Carmel Utilities Paul Pace, Carmel Utilities Greg Hoyes, Hamilton County Surveyor's Office Greg Ilko, Crossroad Engineers John South, Hamilton County Soil & Water Liz Hobbs, Indiana Land Development Corp. Project File Copy Engineering Department Review \\Apps2\user data\eng\shared\DHiII\PROJREV06\ABNEYGLEN#2.doc 01/17/2006 18:49 3177769628 HAMILTON CO SURVEVOR PAGE 01/03 " :J((nion C. 'l,f'ard, $Un1fVor I q'fjolll' (J '7) 77t;-.~4~).r; 'Fax (}ltl 77~G:1S Slfttl! 188 Olle .Hamiltoll CDlln~1 Square ~""b/C'$IIj/fr. 7rulitlllO 4606(1_.1.1)0 ~~. .. 'r' \ 1.-i.r'lll I ~ .......,r. i' /~.::vm 1~~.1.'\ .'. JAN I' t.! \ j' , -;;\.... I I \;:\" U(lr~I(' j'.. I ..~/~ '\.'",1 .j I',,~~t ~/ - /' "\,' i j-- '7/.-(\ '., ~' .,-,---...- " . . ,: .' I,.>,' ; ...........,.......' 1. January 17, 2006 .Paul t Cripe, Inc. ATTN: Chris Wiseman 7172 Graham Road Indianapolis. IN 46250 VIA FACSIMILE: 841-4798 Re: Abney Glen Dear Mr. Wiseman: We have reviewed the construction plans submitted to the Hamilton County Surveyor's Office on January 3, 2006 for this project and bave the following comments: I. This proposed project falls within the incorporated area of the City of Cannel. 2. This proposed project DOES NOT fa.1I within a Cannel Wellhead Protection Zone. 3. This project will be a Hamilton County Regulated Drain SubdiYision. 4. The proposed project falls in the Long Branch Regulated Drain Watershed and has the J.W. Brendle Regulated Drain upstream ofthis site. S. Please submit the following procedural items to this office. petition fot regulated subdivision, outlet permit, engineer's estimate, and all associated bonds for 120% of construction cost. The applications are available on our website at htt;p:llwww.co.hamilton.in.us.gO to Departments, Surveyor, and FonD.S. 6. Hamilton County Ordinance 4-26-99-C(3) will require improvements to the natural watercourse across the site. These improvements witt included, but not limited to, debris and flowline obstruction removal, tree clearing from top of bank to top of bank plus 30 feet on the north side ofthe ditch, and stteam bank erosion repair and stabilization. 01/17/2006 18:49 3177769628 HAMILTON CO SURVEYOR PAGE 02/03 7. The HCSO would like to see the SSD laterals S' off the property lines so they can be routed around the utilities that are nonnally placed on the property lines. This should still allow the lateral to fit between the P.L. and the driveways. Also, the SSD laterals for lots 17, 24, 36, and 42 area either not shown or not easily identifiable. 8. Since rear yard laterals are being provided for some lots, please add HeSO Standard Detail SSD-2. Also, note the fOllowing details were revised in 2005 and should be used in place of the old details: SSD~l, SSO-2, and 0-16. 9. If the existing house had a sump pump disc:harge, is should be located and connected into the curb line SSD like all the otber lots. 10. Stnlcture 794 should be extended to the property linE and placed to most efficiently place up the drainage from Long Branch Estates. t 1. Structure 746, 750, 767, 769, and 795 should all extend to the nonna! pool elevation or the flowline of the open channel. Structure 795 will need to discharge at the flowline and not approximately 6' above, as this will cause maintenance and erosion problems. 12. Per the StonnCAD report, pipe mns P-12S, P-1, P-2. P-8, and P-120 all exceed the maximum allowable velocity of 10 fps. Please modify the design to bring these velocities into the allowable limits. 13. The construction plans reference retaining walls on the construction plans, which are not in complian.ee with the approved HeSO Standard Pond Details (D-6 to D-8). Please provide pond cross sections and show what is planned. Also. based off of the pond outlet details and my interpmation of the proposed retaining wal1~ the walls will require a variance from the HCSO Standard Details. Please submit a letter requesting the variance from the Hamilton County Drainage Board. 14. It does not appear that the pipe run &om Str. 772 to Str. 779 has sufficient easement at all locations on the pipe. Please review to make sure all pipe nms have 15' easement each direction from. the centerline ofthe pipe. 15. Per the plat, the pipe run from Str. 770 to Str. 771 is not covered by a drainage easement. Please revise. 16. The storm sewer P &. P sheets show a few pipes that do not meet the minimum 2' of cover requirement. Please redesiiJ1 to gain the required cover over the top of the pipes. 17. Per the stonn stnlctu~ data table, Str. 728 has an invert in elevation lower then the invert out elevation. 81/17/2886 18:49 3177769628 HAMIL TON CO SURVEYOR PAGE 83/83 18. On any structure greater then 48" from TC to invert, please use a manhole with steps instead of the 24t1 x 24" boxes. This appears to be approximately 12 structureS. 19. Please coordinate the drainage from north of1218t Street with Stoeppelwerth & Associates, as a project known as Kendall Wood bas an impact on the drainage for this area and also provides drainage for the other ILD project on Shelbome Road. 20. What is the runoff from the direct discharge area (floodplain)? The HCSO does the allowable discharge for the site a little c1ifferently (acreage · allowable release rate- direct nmoff amount = allowable runoff for detained area). This site is s. Jittle different in that the floodplain compensation ponds could provide "detention" for the floodplain area. Please review the drainage calculation and make sure the 4'site" meets the allowable release rate. 21. No landscape planting will be pennitted or allowed within the proposed regulated drainage easements per Indiana Code 3~9-27.33(d). In common areas that are dedicated as Drainage Easements, no trees will be allowed within 1 S feet in each direction from the centerline of pipe. Any proposed street trees sh.ould be behind the sidewalks to prevent the root infiltration into the SSDs under the curb line. Please provide a copy of the current Landscape Plans. 22. Please note that further comments may be necessary at a later date. Should you have any questions, I can be reached at 317-776-8495. Sincerely, ~~ Plan Reviewer cc: Matt Griffin - Carmel DOCD John South - HCSWCD Amanda Foley - Cannel Engineering Dick Hill- Cannel Engineering Mike McBride - HCHD Greg Ilko . Crossroads Engineers, Indiana Land Development Corporation w u Carmel T AC Agenda CTRWD Comments 9:00 a.m. Orin Jessup Land Co, Sec 1, lots 140-142 pt - Mr. Window Docket No. 05120024 UV Chapter 9.01 Permitted Uses . . n neede showin revised flow,., tes for the change in use. 9:10 a.m. Docket No. 06010006 SP: Windsor Grove II * * *CTR WD application and construction plans have been received and are currently under review. 9:20 a.m. Docket No. 05120010 SP: Abney Glen ****CTRWD application is needed. Construction plans were received and are currently under review. 9:~!\ a.m. Docket No. 06010005 Z: Shelborne Property PUD ****Within CTRWD service area. 9:!\0 a.m. Docket No. 06010003 Z: Guerrero Property PUD ****Within CTRWD service area. 10:0!\ a.m. Docket No. 06010009 Z: Crook PUD ****Within CTRWD service area. 10:20 a.m. Docket No. 06010002 Z: Old Meridian Place Rezone ****Project is outside of CTRWD service area. 1 o:~o a.m. Docket No. 06010008 Z: Midtown Village PUD ****Project is outside of CTRWD service area. 10:4!\ a m. Docket No: 05120025 Z 126tb & Keystone/Gramercy PUD ****Project is outside of CTRWD service area. 11'00 a.m. Docket No. 05120026 Z and 05120027 DP/ADLS: Village Green PUD ****Project is outside of CTRWD service area. 11 :1!\ a.m. Docket No. 06010007 DP/ADLS: Gateway Pavilion ****Within CTRWD service area. Plans and CTRWD application will be needed. 11'~0 a m Docket No. 06010010 SP: Village of Westclay Section 150001 ****CTRWD application is needed. Construction plans were received and are currently under review. 11 :40 a.m. Docket No. 06010001 Z: Monon Townes PUD ****Project is outside of CTRWD service area. 11 :!\!\ a.m. Docket No. 06010011 ADLS Amend: Conseco Parking Lot ****Project does not affect the sanitary sewers. No action needed. Page 1 of2 Conn, Angelina V From: Conn, Angelina V Tuesday, December 13, 20054:29 PM DeVore, Laura B Morrissey, Phyllis G; Hollibaugh, Mike P; Keeling, Adrienne M; Brewer, Scott I; Hancock, Ramona B; Griffin, Matt L; Littlejohn, David W; Tingley, Connie S; Lillard, Sarah N; Blanchard, Jim E; Holmes, Christine B; 'cwiseman@cripe.biz' Subject: RE: Docket No. Assignment: (SP) Abney Glen (#05120010 SP) Sent: To: Cc: Please note: Petitioner will not be ready for the December TAC meeting. They would like to wait until the Jan. 2006 TAC meeting. Angie Conn, Planning Administrator Division of Planning & Zoning Dept. of Community Services City of Carmel p. 317-571-2417 t 317-571-2426 aconn@carmel.in.gov From: Conn, Angelina V Sent: Tuesday, December 13, 2005 4:08 PM To: DeVore, Laura B Cc: Morrissey, Phyllis G; Hollibaugh, Mike P; Keeling, Adrienne M; Brewer, Scott I; Hancock, Ramona B; Griffin, Matt L; Littlejohn, David W; Tingley, Connie S; Lillard, Sarah N; Blanchard, Jim E; Holmes, Christine B; 'cwiseman@cripe.biz' Subject: Docket No. Assignment: (SP) Abney Glen (#05120010 SP) Laura: I have notified the petitioner, updated the file, and issued the necessary Docket Number for (SP) Abney Glen. It is the following: Docket No. 05120010 SP: Abney Glen SP Application Fee: $103 per lot x 44: Total Fee: $772.50 $4,532.00 $5,304.50 Docket No. 05120010 SP: Abney Glen The applicant seeks to plat 44 residential lots on 38.68 acres. The site is located at 11850 Shelborne Rd and is zoned S1/Residence-ROSO. Filed by Chris Wiseman of Paull Cripe, Inc, for Paul Shoopman. Petitioner, please note the following: 1. This item will be on the Deee",Iser 21, 2996 January 18, 2006, agenda of the Technical Advisory Committee (TAC). Packets to all TAC members should have been delivered by Dec. 6, 2005. 2. Mailed and published public notice does not need to occur. 3. Proof of Notice is not needed. 4. The Filing Fee must be paid on or before January 18, 2006. Failure to do so will result in this application being tabled to the January 18, 2006, Technical Advisory Committee Meeting. 5. This item will be reviewed administratively. PETITIONER: refer to your instruction sheet for more detail. 12/1312005 Page 2 of2 / A review letter will be forthcoming once the plat and detailed construction plans (including landscape plans) are submitted. Mr. Wiseman can be contacted at 842-6777 (fax: 841-4798 or email: Gw.i~~m~n@Grip~,pi?:)' Mr. Shoopman can be contacted at 415-0459 (Fax: 415-0466) Thank you. Angie Conn, Planning Administrator 12/13/2005 11/134/213135 14:313 3177769628 HAMILTON CO SURVEYOR PAGE 131/131 9 XentolJ C. 'Ward, Sun/{'Yor '-pfi(1111! (J T7) 770'.84':'5 'FlTx (F7l 77t';"~16.:!S SlIir,' T SS Oil(: }(tJ7lli/tOIl ClllJlltr square .iY oblmrj{fe, 1 "dioll" 4 {.otit'-.1 2Jl' Re: Abney Glen November 4, 2005 Indiana Land Development Corporation ATTN: Paul Shoopman 8170 Zionsville Road Indianapolis, IN 46268 VIA FACSIMILE: 415-0466 Dear Mr. Shoopman: The Hamilton County Surveyor's Office has received your proposed layout revisions to Abney Glen. The Hamilton County Surveyor's Office agrees with the concept of the floodplain compensation area being proposed but can not verify the accuracy. We need to see exhibits showing the area being filled and the area being excavated, along with supporting earthwork calculations. Once these items are received, we can review these items and set this matter for consideration with the Hamilton County Drainage Board. Should you have any questions, I can be reached at 317-776-8495. Sincerely, /92w; ~ Greg Hoyes Plan Reviewer cc: Matt Griffin - Cannel DOeD Dick Hill - Carmel Engineering Dennis McGuire - P.I. Cripe David Lash - P .1. Cripe