Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
04120032 Large Format Plans
LARGE FORMAT PLANS ,,\ ARCHITECT: CSO 280 E. 96TH STREET, SUITE 200 INDIANAPOLIS, INDIANA 46240 (317) 848.7800 (317) 574.0957 FAX INDEX OF DRAWINGS • COVER 0 A201 DEMOLITION CONSTRUCTION PLAN • A202 REFLECTED CEILING FINISH PLAN • A203 ELECTRICAL DATA PLAN ELEVATIONS 2ND FLOOR KEY PLAN SCALE: NOT TO SCALE (9 NORTH F P**4bh, E: N/ 44Nhh�, E=3 2ND FLOOR, 280 EAST 96TH STREET INDIANAPOLIS INDIANA 26240 SPECIFICATIONS AND GENERAL NOTES 0 CONTRACT CONDITIONS 1.11 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL 6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR 12 FURNISHINGS CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, 0.1 THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION, EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, REINSTALL SUCH ITEMS. 12.1 CASEWORK: ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF 1.12 PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND OPERATING FOR TEN DAYS. SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD FOLLOWING: RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED MAINTENANCE Of EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND FOR THE VARIOUS SUBSTRATES, AS INDICATED. .1 IMPERIAL CABINET CO., INC. AS FOLLOWS: THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE STRAIGHT WITH NO DISTORTIONS. 2 MERILLAT INDUSTRIES, INC. INSPECTION, CARE AND MAINTENANCE OR REPAIR Of ARCHITECTURAL 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM 1. FERROUS METAL: .3 YORKTOWNE CABINETS 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. WIDTH NOT TO EXCEED 1/8 U.O.N. A ACRYLIC SEMI -GLOSS ENAMEL FINISH: FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC 15/16 MECHANICAL AND ELECTRICAL PROCEEDING WITH CONSTRUCTION. 2 DEMOLITION OUTLETS. LATEX PRIMER. 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC 15/16.1 MECHANICAL (INCLUDING PLUMBING, ARE PROTECTION AND HVAC) AND RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, 2.1 COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE SEMI -GLOSS ENAMEL ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE 7 JOINT SEALERS 2. NON-FERROUS METAL RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. WORK. 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING 2.2 WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR AND FIXTURES: LATEX PRIMER. BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, .1 "DOW CORNING 786"; DOW CORNING CORP. 2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND WORKMANSHIP. OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION .2 "SCS 1702 SANITARY"; GENERAL ELECTRIC CO. SEMI -GLOSS FINISH ELECTRICAL SYSTEMS, 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED AND .3 "863 #345 WHITE"; PECORA CORP. 3. FERROUS STRUCTURE: PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING .4 "PROGLAZE WHITE"; TREMCO CORP. A. ACRYLIC DRY FOG FLAT FINISH: 15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF CONTRACTOR'S RESPONSIBILITY. ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND .5 "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS 1. FINISH: 2 COATS 57601 UNI -GRIP -WB WATER DESIGN/BUILD DRAWINGS FOR FIRE R STATE FI MECHANICAL, AND # PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED REDUCIBLE ACRYLIC DRY FOG COATING CERTIFIED ENGINEER, 0.2 WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR 7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING 4. NON-FERROUS STRUCTURE: 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECTS AND ENGINEER'S RULES AND REGULATIONS. ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. SURFACES: A. ACRYLIC DRY FOG FLAT FINISH: DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS 0.3 ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD 2.3 WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED A "CHEM CALK 600'; BOSTIK CONSTRUCTION PRODUCTS DIV. 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL .2 "AC -20"; PECORA CORP. REDUCIBLE ACRYLIC DRY F>G COATING. AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION BE INCLUDED. .3 "SONOLAC"; SONNEBORN BUILDING PRODUCTS 8. WOOD: DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED 2.4 REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE .4 "TREMCO ACRYLIC LATEX 834'; TREMCO, INC. A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. PROJECT. DRAWINGS. 1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX 15/16.4 SUBMIT ARE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE 0.4 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE 2.5 ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE 8 DOORS AND WINDOWS PRIMER -SEALER. OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS SEMI -GLOSS ENAMEL COORDINATE WITH OTHER CEILING COMPONENTS. SPECIFIED CAPACITIES Of THE EQUIPMENT. METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. B. STAIN -VARNISH RUBBED FINISH: 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS 0.5 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS FINISHES. 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED 1. FILLER: 1 COAT 14800 WONDER WOODSTAIN SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING 2.6 EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. PASTE WOOD FILLER (OPEN GRAIN WOODS). OWNER'S AGENT. Cl JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH 2. STAIN: 1 COAT #96XX WONDER WOODSTAIN 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED C3 ' GOVERN THE WORK. NOTED TO BE REPAIRED, AND LOCKSETS. ALKYD STAIN. WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. 1` 0.6 NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE 2.7 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 3. SEALER: 1 COAT4900 WONDER WOODSEALER SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN # VERITY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED 2.8 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. QUICK DRY SEALER. EQUIPMENT. DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK 4. FINISH: 2 COATS #4600 WONDER WOODSTAIN 15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY IN SCOPE OF CONTRACT. 9 FINISHES ALKYD SON VARNISH. GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S 2.9 PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING 10. GYPSUM WALLBOARD: 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND FM k". , INTERPRETATION. DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. A. ACRYLIC LATEX SATIN ENAMEL FINISH: INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL 0.7 INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS" 1. PRIMER: 1 COAT #50801 WONDER TONES LATEX COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND U, MANUFACTURER'S RECOMMENDATIONS. SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT .1 INSTALL ELIMINATOR TYPE HEAD TRACK AT WALLS TERMINATING PRIMER -SEALER. TENANTS VENDORS 10 DETERMINE THE PHASE DURING WHICH THE THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. AT CEILING. USE PREFORMED OUTSIDE CORNERS. 2. FINISH: 2 COATS 35XX WONDER TONE ACRYLIC 1 GENERAL REQUIREMENTS # INSTALLATION SHALL OCCUR, 2.10 CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES LATEX SATIN ENAMEL 15/16.9 DIMENSIONS IF IDENTIFIED ARE TO CENTERLINE OF OUTLET OR GANG Of AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY 9.2 GYPSUM BOARD: PROVIDE 5/8' THICK REGULAR AND TYPE "X" TAPERED 13. PRECAST CONCRETE: ' 1.1 WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS OUTLETS, UNLESS 01HERWISE NOTED. WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE- EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS) 15/16.10 ALL SWITCHES AND SWITCHPLAIES SHALL BE BUILDING STANDARD BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE 1. PRIMER: 1 COAT #1502 WONDER -SHIELD ACRYLIC COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. LATEX HOUSE PAINT PEl► ". 1.2 THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS 2. FINISH: t IVORY. INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE COAT #4410i OEV-VO- TD( LATEX 15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY AND "FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS. 1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED TEXTURE COATING. SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING FITTING, PROVIDING PROPER ACCESS TO RECEPTACLES. RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT" SET. MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA- h AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE 15/16.12 IF ADDITIONAL OUTLET'S REQUIRED, COORDINATE WITH ARCHITECTURAL WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR 2.11 PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND AN AND 9.11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLE FOR SPECIFIC LOCATION. REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE FINISHING OF GYPSUM BOARD. WITHOUT WRINKLES, GAPS OR OVERLAPS. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. 1.3 CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO `= ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN" WORKMANSHIP. 5 METAL FABRICATIONS DAMAGED OR SOILED TILES. ACCEPTABLE. CONSTRUCTION. 1.4 SUBMIT SHOP DRAWINGS ( OR SUBMITTALS } TO THE ARCHITECT FOR THE .2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CORNERS AND 6" FROM FOLLOWING ITEMS: 5.1 PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS OUTSIDE CORNERS. OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL GN GENERAL NOTES .1 METAL FABRICATIONS. REQUIRED TO COMPLETE WORK. REFLECTED CEILING PLAN SHALL GOVERN. 10 SPECIALTIES .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. 2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND .3 DOORS, FRAMES AND HARDWARE. 6 WOOD AND PLASTIC LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS 10.1 ARE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6" X 6' ACOUSTICAL UNLESS NOTED OTHERWISE. BUILDING STANDARD, PROVIDE JL INDUSTRIES "AMBASSADOR" SERIES, PROCEEDING WITH CONSTRUCTION. PANEL ). 6.1 CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE 'CONSTRUCTION SEMI RECESSED' DUO -PANEL, FIELD PAINTED. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: .5 VCT FLOORING AND BASE (COLOR SAMPLES }. GRADE' LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR .6 CARPET (DYE LOT CUTTING AND SEAMING DIAGRAMS ). CONTENT. CASED OPENING UNLESS NOTED OTHERWISE. A. TO FINISHED FACE OF GYPSUM BOARD. .7 PAINT ( 6- X 6" ON ACTUAL SURFACE ). 6.2 PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. EQUIPMENT PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS APA .1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET .8 WALLCOVERINGS ( 9' X 9' DYE LOT CUTTING ). C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32". MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH C. TO TOP OF FINISHED FLOORS. .9 SIGNAGE (SAMPLE SIGN ). 6.3 FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND CARPET. D. TO BOTTOM OF FINISHED CEILINGS. .10 LIGHT FIXTURES ( CATALOG CUTS ). PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, C20 AND C27 RESPECTIVELY AND IDENTIFY LUMBER WITH 9.6 RESILIENT FLOORING: 1.5 TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, � � EXISTING CONSTRUCTION AND WALL TYPES. TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND POWER CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING GNA TERMINATE WALLS AT UNDERSIDE Of CEILING UNLESS INDICATED WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR JURISDICTION. A UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS OTHERWISE. THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING 6.4 FINISH CARPENTRY AND MILLWORK: COMPLY WITH 'PREMIUM GRADE' AWI ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN, PARTITION STANDARDS. OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S " LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS AVOID USE OF CUT WIDTHS LESS THAN 3 AT ROOM PERIMETER. AGENT. SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, 1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR .2 BASE: AT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID 1.6 THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES ANO TO FABRICATION OF MULTIPLE UNITS. BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION. OCCUPANTS ON THE PROJECT S M DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT TEMPORARY PARTITIONS AND DOORS AS REQUIRED TO PROTECT 6.5 COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS). 9.7 USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS THE CONTRACTOR HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM OBSERVATION. HALL F DAMAGES .1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACE VARIATION OF X" IN 10 FEET, NON -CUMULATIVE. ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT SURFACES. GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT ADDITIONAL CHARGE TO THE PARTY AFFECTED. LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT 1.7 THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS •2 PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0" NON- CONTRACT EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES AND ALARMS ELECTRICAL OR DATA OUTLET LOCATIONS. 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. 6.6 CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 400B FOR STANDARDS: GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO 1.8 SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT S� �FCLOSE-IN OF WALLS. PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. FLAMMABILITY: ASTM 2859 6/�� � , �• GNA SOUND INSULATED AND ARE RATED PARTITIONING SHALL BE CAULKED AT SUBMIT THE FOLLOWING INFORMATION: SURFACE BURNING: ASTM E84 Cf C0 p7�A C PERIMETER WITH ACOUSTICAL OR ARE RATED SEALANT AS APPLICABLE. _ .1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: SMOKE DENSITY: ASTM E662 �.', St 4r NST PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. 1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF GP -50" (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 SOUND ABSORPTION: ASTM C423 C/� C�' at w�fh �gZZ ��CT� PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED 0 028 NOMINAL THICKNESS C, 4aZ e ON PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. ( ); EDGES: GP -28 (0.028 NOMINAL FADE RESISTANCE: AATCC 16E`,, �'lljgL CA4, 9�/at; TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL THICKNESS/ N/ es. on .2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. )• STATIC RESISTANCE: AATCC 134 �(• %j� s JUNCTION BOXES ARE NOT PERMITTED. .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL •2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. WARRANTY: 10 YEARS /NOiC(�1, SFAI/jG, GN.10 ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO 3 CABINET HARDWARE SCHEDULE: o t FS CONTRACTOR. ACCOMMODATE THE SUBSTITUTION. 1 HINGES: FULLY CONCEALED, SELF "1000 SERIES' 1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. CSy/p .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL q AFFECT THE CONTRACT SUM AND CONTRACT TIME. BY GRASS OR EQUAL. .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4.ON CENTER, 1.9 STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME #4483 OR EQUAL AS MANUFACTURED BY STANLEY.HERE svQYE ©� FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. 3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH �� r *.f THE ��° < „�•• `S � 1.10 THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS, �-yESE PI�+I�s HAV = BEEN .CC-} T`-"®OA'9CHg���,��� HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE MANUFACTURED BY STANLEY. , t liki� ;�; RVIC-S & THE DEPT. QF C'C•�' BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN .4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES f r ��� '•"' A=LAN RIE I W C//�,R��i =l_ F irk UL-,- i. F REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. WITH POSITIVE STOP AND LOCKOUT POSITION, WITH - ` r _ CO3VSTF;UC CONSTRUCTION CITY ARMEE/CL TOWN ILP s HEAVY-DUTY FULL EXTENSION; 1429 OR EQUAL AS THEY ARE FSE L ^ _r ``� P g { l Dept. of Com ni Services -- Bu' in &Cod force MANUFACTURED BY KNAPE & VOGT. SUBJECT TO C01%11'L1 GE WITH ' ` _ vic uare 1" Floor armel, IN 2 I._GC - fi_�7. 5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF REGULATIONS ©F S t r ,T ; PLAN AU N CERTI ATIO A SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION `~ �• CITY OF CAR1��:.�1:�..�::��• s �.���� :.. . ........ . MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED As the autho ' r pe its`, I c t s laps SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT are IDENTIC epart. o uil g OR EQUAL Services. I also under , a S P WORK ORDER will ed, Authorized Signatu Prin 1 e Required wt t Section 10 of the Ca ih Co 'Buildin > e" a on 29.4.2 '+ and Se ' .3 entitled "Administration". Required by C ay Towns Zoning Ordinance, Section 12�Q�04 31.1 ed "Violations and Penalties". V -� -� S:Permits/Forms/AuthentStickerll-01 CSO #LACE 04 ^�Cl.- �, f 7 FA p 1 I Y II I I N I II �i r I I DP3 I I I DP1 j II D 3 i DP3 r I I � I I I I --I---J I L--- j I N I I I I I T --- r i` SCALE: 1/8"`=1f-0" DP3 l I I NORTH GENERAL DEMOLITION NOTES: 1 . REMOVE ALL WALLS, MILLWORK, DOORS, AND DOOR FRAMES AS SHOWN DASHED. RESERVE DOORS AND DOOR FRAMES FOR RE—USE IN NEW PROJECT SCOPE. 2. SAVE ALL ITEMS REMOVED FROM THE SPACE PER OWNER'S DIRECTION UNLESS NOTED OTHERWISE. 3. DEMOLISH EXISTING WALL AND/OR FLOOR SURFACES BACK TO A POINT WHERE INSTALLATION OF NEW FLOORING FINISHES IS POSSIBLE. 4. REMOVE EXISTING FINISHES WHERE NEW FINISHES ARE TO BE INSTALLED. REFERENCE FINISH PLAN TO COORDINATE LOCATIONS OF NEW FINISHES. 5. REMOVE ELECTRICAL AND DEVICE LINES IN WALLS THAT ARE TO BE REMOVED, INCLUDING ALL ATTACHED WIRING. DEMOLISH ELECTRICAL DEVICES AND WIRING BACK TO A POINT WHEREAS PROPER PREPARATION FOR NEW FINISHES IS POSSIBLE. SEE ELECTRICAL AND FINISH PLANS FOR FURTHER INFORMATION. 6. ALL DEMOLISHED RECEPTACLES FROM EXISTING WALLS TO REMAIN SHALL HAVE DRYWALL PATCHED AND REPAIRED PRIOR TO INSTALLATION OF WALL FINISHES. DEMOLITION PLAN NOTES: DP1 REMOVE DOOR/FRAME AND SAVE FOR REUSE. DP2 REMOVE SECTION OF WALL AND PREP FOR NEW WINDOW. DP3 REMOVE CASEWORK AND SAVE FOR REUSE. DEMOLITION LEGEND: 2ND FLOOR CONSTRUCTION PLAN SCALE: 1/8"= V-0" NORTH EXISTING CONSTRUCTION TO BE REMOVED. EXISTING PARTITION TO REMAIN. EXISTING DUPLEX WALL OUTLET TO BE DEMOLISHED. V EXISTING PHONE/DATA WALL OUTLET TO BE DEMOLISHED. EXISTING CARD READER AND ELECTRIC STRIKE TO BE DEMOLISHED. DENOTES AREA NOT IN CONTRACT. i" 2" 2" 2" J —V J —U J —V DENOTES AREA NOT IN CONTRACT. FRAME DENOTES NEW MILLWORK. Fgh NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. F� EXISTING DOOR AND FRAME TO REMAIN. iin i' '07 r ;# ----- -----_ w=�[ L5�Lj0!:(nck: f; U W= z Q z O Q z O N �cavWin O¢O¢WOO� Z m W O = U Y U W F- Q F— Q >> Lr l J d U II it II II II II it O = 0:::= F— :2W :2 W Y U�� __Ja- a a Uwc>cn 2000 RECEPTION 3'-0" 8'-4" r' AL/GL AL/GL D1 L,CR,ES,CL,S 2001 CONFERENCE 3'-0" 8'-0" 1 3/4" AL/GL — I AL/GL — PS,S R 2002 BREAK ROOM r , WbME N 8'-0" r r '� — _J f f :hasI F 2006 LIBRARY 3'-0" 8'-0" 1 3/4" AL/GL D4 AL D4 ------------ REUSE DEMO'D DOOR 2ND FLOOR DEMOLITION PLAN SCALE: 1/8"`=1f-0" DP3 l I I NORTH GENERAL DEMOLITION NOTES: 1 . REMOVE ALL WALLS, MILLWORK, DOORS, AND DOOR FRAMES AS SHOWN DASHED. RESERVE DOORS AND DOOR FRAMES FOR RE—USE IN NEW PROJECT SCOPE. 2. SAVE ALL ITEMS REMOVED FROM THE SPACE PER OWNER'S DIRECTION UNLESS NOTED OTHERWISE. 3. DEMOLISH EXISTING WALL AND/OR FLOOR SURFACES BACK TO A POINT WHERE INSTALLATION OF NEW FLOORING FINISHES IS POSSIBLE. 4. REMOVE EXISTING FINISHES WHERE NEW FINISHES ARE TO BE INSTALLED. REFERENCE FINISH PLAN TO COORDINATE LOCATIONS OF NEW FINISHES. 5. REMOVE ELECTRICAL AND DEVICE LINES IN WALLS THAT ARE TO BE REMOVED, INCLUDING ALL ATTACHED WIRING. DEMOLISH ELECTRICAL DEVICES AND WIRING BACK TO A POINT WHEREAS PROPER PREPARATION FOR NEW FINISHES IS POSSIBLE. SEE ELECTRICAL AND FINISH PLANS FOR FURTHER INFORMATION. 6. ALL DEMOLISHED RECEPTACLES FROM EXISTING WALLS TO REMAIN SHALL HAVE DRYWALL PATCHED AND REPAIRED PRIOR TO INSTALLATION OF WALL FINISHES. DEMOLITION PLAN NOTES: DP1 REMOVE DOOR/FRAME AND SAVE FOR REUSE. DP2 REMOVE SECTION OF WALL AND PREP FOR NEW WINDOW. DP3 REMOVE CASEWORK AND SAVE FOR REUSE. DEMOLITION LEGEND: 2ND FLOOR CONSTRUCTION PLAN SCALE: 1/8"= V-0" NORTH EXISTING CONSTRUCTION TO BE REMOVED. EXISTING PARTITION TO REMAIN. EXISTING DUPLEX WALL OUTLET TO BE DEMOLISHED. V EXISTING PHONE/DATA WALL OUTLET TO BE DEMOLISHED. EXISTING CARD READER AND ELECTRIC STRIKE TO BE DEMOLISHED. DENOTES AREA NOT IN CONTRACT. i" 2" 2" 2" D1 D2 D3 D4 DOORFRAME 1 ELEVATIONS A201 J SCALE: 1/4" = 1'-0" GENERAL CONSTRUCTION NOTES: 1. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER. DO NOT SCALE DRAWINGS. 2. SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. 3. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION. 4. REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE. 5. ALL NEW TRACK AND TRIM AT WALL/CEILING CONDITIONS SHALL MATCH EXISTING COLOR AND MATERIAL TO PROVIDE CONTINUOUS/CONSISTENT APPEARANCE THROUGHOUT CEILING. 6. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. 7. EXISTING DOORS AND DOOR FRAMES TO BE REUSED ARE TO BE CLEANED AND REINSTALLED AT COMPLETION OF CONSTRUCTION. CONTACT DESIGNER TO REVIEW AND APPROVE DOORS THAT ARE QUESTIONABLE FOR REUSE. 8. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). 9. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. 10. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR, UNLESS NOTED OTHERWISE, TO MEET CURRENT ADA CODE REGULATIONS. 11. APPLY SEALANT AT ALL PLUMBING FIXTURES, AT JUNCTURE WITH WALL, AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. 12. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. 13. ALL FINISHES ON WALLS SCHEDULED TO REMAIN SHALL BE CLEANED, PATCHED, AND REPAIRED TO PROVIDE A LIKE NEW APPEARANCE. CONSTRUCTION PLAN NOTES: FP1 ALIGN FINISHED FACES. FP2 PROVIDE STORE—FRONT DOOR AND WINDOW SYSTEM TO MATCH OPPOSITE ENTRY. FP3 PROVIDE CLERESTORY WINDOW SYSTEM O W/ PATTERNED GLASS TO MATCH EXISTING CLERESTORY IN SPACE. FP4 INSTALL COAT ROD AND SHELF REMOVED DURING DEMOLITION. VERIFY LOCATION OF NEW WING WALL W/LENGTH OF SHELF. FP5 REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. GC TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. FP6 PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE MAKER, REFRIGERATOR, AND/OR COFFEE MAKER. VERIFY EXACT LOCATION OF ALL APPLIANCES REQUIRING A WATER SOURCE WITH TENANT. FP7 PLOTTER PROVIDED AND INSTALLED BY TENANT. GC TO PROVIDE POWER SOURCE FOR PLOTTER. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. FP8 NEW SHELVING W/RECESSED STANDARDS AND ADJUSTABLE BRACKETS BY OWNER. GC TO INSTALL RECESSED STANDARDS SUPPLIED BY OWNER. WALL LEGEND: NOTES: EXISTING PARTITION TO REMAIN NEW WALL PARTITION ® NEW LOW WALL PARTITION W1 2-1/2" 20 GAUGE METAL STUDS 0 16" O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. W2 2-1/2" 20 GAUGE METAL STUDS @ 16" O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE 2-1/2" SOUND INSULATION INSIDE WALL AND IN HORIZONTAL SURFACE ABOVE CEILING. INSULATION TO EXTEND 2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF WALL. W3 NEW WALL CONSTRUCTION TO MATCH BUILDING STANDARD DEMISING WALL CONSTRUCTION. W4 NEW WALL CONSTRUCTION TO MATCH EXISTING ADJACENT PARTITION CONSTRUCTION. W5 EXTEND EXISTING PARTIAL HEIGHT WALL TO UNDERSIDE OF CEILING. J —V J —U J —V DENOTES AREA NOT IN CONTRACT. FRAME DENOTES NEW MILLWORK. Fgh NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. F� EXISTING DOOR AND FRAME TO REMAIN. D1 D2 D3 D4 DOORFRAME 1 ELEVATIONS A201 J SCALE: 1/4" = 1'-0" GENERAL CONSTRUCTION NOTES: 1. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER. DO NOT SCALE DRAWINGS. 2. SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. 3. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION. 4. REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE. 5. ALL NEW TRACK AND TRIM AT WALL/CEILING CONDITIONS SHALL MATCH EXISTING COLOR AND MATERIAL TO PROVIDE CONTINUOUS/CONSISTENT APPEARANCE THROUGHOUT CEILING. 6. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. 7. EXISTING DOORS AND DOOR FRAMES TO BE REUSED ARE TO BE CLEANED AND REINSTALLED AT COMPLETION OF CONSTRUCTION. CONTACT DESIGNER TO REVIEW AND APPROVE DOORS THAT ARE QUESTIONABLE FOR REUSE. 8. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). 9. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. 10. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR, UNLESS NOTED OTHERWISE, TO MEET CURRENT ADA CODE REGULATIONS. 11. APPLY SEALANT AT ALL PLUMBING FIXTURES, AT JUNCTURE WITH WALL, AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. 12. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. 13. ALL FINISHES ON WALLS SCHEDULED TO REMAIN SHALL BE CLEANED, PATCHED, AND REPAIRED TO PROVIDE A LIKE NEW APPEARANCE. CONSTRUCTION PLAN NOTES: FP1 ALIGN FINISHED FACES. FP2 PROVIDE STORE—FRONT DOOR AND WINDOW SYSTEM TO MATCH OPPOSITE ENTRY. FP3 PROVIDE CLERESTORY WINDOW SYSTEM O W/ PATTERNED GLASS TO MATCH EXISTING CLERESTORY IN SPACE. FP4 INSTALL COAT ROD AND SHELF REMOVED DURING DEMOLITION. VERIFY LOCATION OF NEW WING WALL W/LENGTH OF SHELF. FP5 REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. GC TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. FP6 PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE MAKER, REFRIGERATOR, AND/OR COFFEE MAKER. VERIFY EXACT LOCATION OF ALL APPLIANCES REQUIRING A WATER SOURCE WITH TENANT. FP7 PLOTTER PROVIDED AND INSTALLED BY TENANT. GC TO PROVIDE POWER SOURCE FOR PLOTTER. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. FP8 NEW SHELVING W/RECESSED STANDARDS AND ADJUSTABLE BRACKETS BY OWNER. GC TO INSTALL RECESSED STANDARDS SUPPLIED BY OWNER. WALL LEGEND: NOTES: EXISTING PARTITION TO REMAIN NEW WALL PARTITION ® NEW LOW WALL PARTITION W1 2-1/2" 20 GAUGE METAL STUDS 0 16" O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. W2 2-1/2" 20 GAUGE METAL STUDS @ 16" O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE 2-1/2" SOUND INSULATION INSIDE WALL AND IN HORIZONTAL SURFACE ABOVE CEILING. INSULATION TO EXTEND 2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF WALL. W3 NEW WALL CONSTRUCTION TO MATCH BUILDING STANDARD DEMISING WALL CONSTRUCTION. W4 NEW WALL CONSTRUCTION TO MATCH EXISTING ADJACENT PARTITION CONSTRUCTION. W5 EXTEND EXISTING PARTIAL HEIGHT WALL TO UNDERSIDE OF CEILING. Drawn By Checked By DENOTES AREA NOT IN CONTRACT. FRAME DENOTES NEW MILLWORK. Fgh NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. F� EXISTING DOOR AND FRAME TO REMAIN. DOOR SCHEDULE Drawn By Checked By DOOR FRAME MC HARDWARE REMARKS SIZE iin W w=�[ L5�Lj0!:(nck: U W= z Q z O Q z O N �cavWin O¢O¢WOO� Z m W O = U Y U W F- Q F— Q >> Lr l J d U II it II II II II it O = 0:::= F— :2W :2 W Y U�� __Ja- a a Uwc>cn 2000 RECEPTION 3'-0" 8'-4" 1 3/4" AL/GL D1 AL/GL D1 L,CR,ES,CL,S 2001 CONFERENCE 3'-0" 8'-0" 1 3/4" AL/GL — I AL/GL — PS,S SEE ELEVATION 1/A203 2002 BREAK ROOM 3'-0" 8'-0" 1 3/4" WOOD D3 AL D3 PK REUSE DEMO'D DOOR 2006 LIBRARY 3'-0" 8'-0" 1 3/4" AL/GL D4 AL D4 L,S REUSE DEMO'D DOOR DOOR SCHEDULE NOTES: 1. ALL WOOD DOORS TO BE PAINTED TO MATCH BUILDING STANDARD. 2. ALL HOLLOW METAL DOOR FRAMES TO MATCH BUILDING STANDARD. 3. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 4. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD. 5. COORDINATE KEYING LOCKSETS WITH TENANT. Owner: CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2004 Project: LACE RENOVATION SEVEN PARKWOOD 280 E. 96TH ST. INDIANAPOLIS, INDIANA 46240 Scope Drawings: These drawings indir,ate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. Drawing Title: DEMOLITIO CONSTRUCTION PLAN Revisions: 10/5/04 PRICING SET 10 19/04 ADD 1 zL 10/20/04 ADD 2,1 12/3/04 CONSTRUCTION SETD Issue Date Drawn By Checked By 9/21/04 MC MC WL T 0.919 a ARM100361 `TATE Of � CJ CHI Drawing Number: A201 Project Number: LACE 04 2ND FLOOR REFLECTED CEILING PLAN SCALE: 1/811= i #_O" 2ND FLOOR FINISH PLAN SCALE: 1/811=1 $—On NORTH NORTH GENERAL CEILING NOTES: 1. MECHANICAL AND ELECTRICAL IS DESIGN—BUILD. DESIGN—BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN—BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. 2. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN—BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. 3. ALL WALLS GO TO BOTTOM OF CEILING UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. 4. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. 5. CEILING HEIGHT IS 9'-0" A.F.F. UNLESS NOTED OTHERWISE. 6. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS TO NOT SHOW LINE OF DEMOLITION. 7. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING. G.C. TO VERIFY EXISTING GRID LAYOUT AND CONDITION. 8. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. 9. RE—USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED, RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION. 10. LOCATE NEW AND RELOCATED SMOKE DETECTORS DUE TO NEW LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGN—BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. CEILING PLAN NOTES: S EXTEND EXISTING CEILING GRID AT THIS LOCATION. cP2 CONFERENCE ROOM DIMMERS: FLUORESCENT DIMMER — LUTRON #NTF-10-277; INCANDESCENT DIMMERS — LUTRON #NT -600. MOUNT EACH DIMMER IN A SEPARATE BACKBOX. 3 8 PROVIDE A BULKHEAD AT 8'-6" AFF. 8 REPLACE WIRE GRID TILES WITH ACOUSTICAL TILES. REFLECTED CEILING LEGEND: EXISTING 2' X 4' FLUORESCENT FIXTURE TO BE REMOVED. EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN. RELOCATED 2' X 4' FLUORESCENT FIXTURE. NE 2' X 4' FLUORESCENT FIXTURE TO BE: LITHONIA #2AVG432—MDR—SMD-277FDB, W/& F32RS-3500K AND HI—LUME DIMMING BALLAST'S. � EXISTING INDIRECT PENDENT LIGHT FIXTURE TO REMAIN. C_===3 EXISTING INDIRECT PENDENT LIGHT FIXTURE TO BE REMOVED. o NEW 4' UNDER CABINET LIGHT FIXTURE TO BE: XXX. Op EXISTING DOWNLIGHT FIXTURE TO BE REMOVED. EXISTING DOWNLIGHT TO REMAIN. OR RELOCATED DOWNLIGHT FIXTURE. NEW 5" APERTURE DOWNLIGHT FIXTURE TO BE: EDISON PRICE, SEMI—SPECULAR ON CONE, #A19/5—EFL W/75 WATT, A -191F AND FLUSH TRIM. AT� NEW RECEPTION AREA WALL WASHER LIGHT FIXTURE TO BE: ARDEE A #DL30W— PERISCOPE— LLFRP W/50 WATT MR16 MEDIUM FLOOD AND FROSTED LENS. NOT USED NEW PENDANT LIGHT FIXTURES OVER THE RECEPTION DESK ARE TO BE: 120V LINE VOLTAGE, 60 WATT EACH, FIXTURES PROVIDED BY LACE, INSTALLED BY CONTRACTORE. EXISTING CEILING MOUNTED EXIT LIGHT W/ DIRECTION INDICATION DUAL—LITE TO REMAIN. EXISTING 2 X 2 LAY—IN GRID SUSPENSION SYSTEM. GYPSUM BOARD CEILING. � TWO WAY SWITCH. �p DIMMER SWITCH. T NL NIGHTLIGHT LOCATION. GENERAL FINISH NOTES: 1. ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION. 2. ALL NEW WOOD DOORS TO BE PAINTED P5 TO MATCH EXISTING DOORS. 3. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH TRANSITION FROM FINISH TO FINISH. 4. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND VINYL TILE TRANSITIONS TAKE PLACE. 5. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. 6. PAINT ALL EXPOSED METAL SURFACES (i.e.. GRILLS, HEATERS, AND FIRE EXTINGUISHER CABINETS) TO MATCH ADJACENT SURFACE. ALTERNATES: 1. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF DESIGNER. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW, FINISH PLAN NOTES: FNS PATCH EXISTING CARPET W/ATTIC STOCK OR DEMO'D CARPET IF FEASABLE. FN2 PATCH EXISTING CORRIDOR FINISHES. FN3 TOUCH—UP ZOLATONE PAINT AS NEEDED ALONG THIS WALL. FINISH LEGEND: FLOORCOVERINGS c1 CARPET — DIRECT GLUE MFG: SHAW PATTERN: CUSTOM COLOR: #7427H-03, POP ART LOCATION: "CIRCLE" CARPET G CARPET — DIRECT GLUE MFG: DESIGNWEAVE PATTERN: Z6361 FREEZE FRAME COLOR: 00277 RIO GRANDE LOCATION: RECEPTION, CONFERENCE , VCT1 VINYL COMPOSITE TILE MFG: AZROCK—CORTINA COLORS COLOR: V-964 SKYLINE STEEL SIZE: 12"x12" LOCATION: BREAK AREA BASES s1 VINYL BASE MFG: JOHNSONITE COLOR: CUSTOM TO MATCH EXISTING SIZE: 2-1/2" STRAIGHT LOCATION: GENERAL a2 VINYL BASE MFG: JOHNSONITE COLOR: STIR 68 WHITESAND SIZE: 2-1/2" STRAIGHT LOCATION: ZOLATONE WALLS 63 VINYL BASE MFG: JOHNSONITE COLOR: 34 ALMOND SIZE: 2-1/2" STRAIGHT R LOCATION: RECEPTION/CONF. ROOM PAINTS P1 PAINT MFG: DURON COLOR: 8662W JOGGING PATH FINISH: SATIN LOCATION: GENERAL P2 PAINT MFG: BENJIMAN MOORE COLOR: 1475 FINISH: SATIN LOCATION: ACCENT P3 PAINT MFG: SURFACE PROTECTION INDUSTRIES PRODUCT: ZOLATON COLOR: MATCH EXISTING COLOR LOCATION: COLUMN LINE WALLS E PAINT MFG: SHERWIN WILLIAMS COLOR: SW6055 FIERY BROWN FINISH: SEMI—GLOSS LOCATION: ACCENT P5 PAINT MFG: DURON COLOR: 8661W LIGHT ALMOND FINISH: SEMI—GLOSS LACQUER LOCATION: DOORS E PAINT MFG: SHERWIN WILLIAMS COLOR: SW6386 NAPERY FINISH: SATIN LOCATION: RECEPTION/CONF. ROOM PLASTIC LAMINATES Pu PLASTIC LAMINATE MFG: NEVAMAR COLOR: SILVERLINE HAUTELINK HLT004T FINISH: TEXTURED LOCATION: HORIZONTAL SURFACES PL2 PLASTIC LAMINATE MFG: NEVAMAR COLOR: SPA WHITE S -7-40T FINISH: TEXTURED LOCATION: VERTICAL SURFACES Owner: !i CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 @Copyright 2004 Project: LACE RENOVATION SEVEN PARKWOOD 280 E. 96TH ST. INDIANAPOLIS, INDIANA 46240 Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. DnxYnO Title: REFLECTED CEILING/FINISH PLAN Revisions: 10/5/04 PRICING SET 10/19/04 ADD 10 10 20 04 ADD 2 0 12/3/04 CONSTRUCTION SETD Issue Date Drawn By Checked By 9/21/04 MC MC 3 THREE—WAY SWITCH. N DENOTES NEW SWITCH LOCATION. NL NIGHTLIGHT LOCATION. GENERAL FINISH NOTES: 1. ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION. 2. ALL NEW WOOD DOORS TO BE PAINTED P5 TO MATCH EXISTING DOORS. 3. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH TRANSITION FROM FINISH TO FINISH. 4. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND VINYL TILE TRANSITIONS TAKE PLACE. 5. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. 6. PAINT ALL EXPOSED METAL SURFACES (i.e.. GRILLS, HEATERS, AND FIRE EXTINGUISHER CABINETS) TO MATCH ADJACENT SURFACE. ALTERNATES: 1. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF DESIGNER. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW, FINISH PLAN NOTES: FNS PATCH EXISTING CARPET W/ATTIC STOCK OR DEMO'D CARPET IF FEASABLE. FN2 PATCH EXISTING CORRIDOR FINISHES. FN3 TOUCH—UP ZOLATONE PAINT AS NEEDED ALONG THIS WALL. FINISH LEGEND: FLOORCOVERINGS c1 CARPET — DIRECT GLUE MFG: SHAW PATTERN: CUSTOM COLOR: #7427H-03, POP ART LOCATION: "CIRCLE" CARPET G CARPET — DIRECT GLUE MFG: DESIGNWEAVE PATTERN: Z6361 FREEZE FRAME COLOR: 00277 RIO GRANDE LOCATION: RECEPTION, CONFERENCE , VCT1 VINYL COMPOSITE TILE MFG: AZROCK—CORTINA COLORS COLOR: V-964 SKYLINE STEEL SIZE: 12"x12" LOCATION: BREAK AREA BASES s1 VINYL BASE MFG: JOHNSONITE COLOR: CUSTOM TO MATCH EXISTING SIZE: 2-1/2" STRAIGHT LOCATION: GENERAL a2 VINYL BASE MFG: JOHNSONITE COLOR: STIR 68 WHITESAND SIZE: 2-1/2" STRAIGHT LOCATION: ZOLATONE WALLS 63 VINYL BASE MFG: JOHNSONITE COLOR: 34 ALMOND SIZE: 2-1/2" STRAIGHT R LOCATION: RECEPTION/CONF. ROOM PAINTS P1 PAINT MFG: DURON COLOR: 8662W JOGGING PATH FINISH: SATIN LOCATION: GENERAL P2 PAINT MFG: BENJIMAN MOORE COLOR: 1475 FINISH: SATIN LOCATION: ACCENT P3 PAINT MFG: SURFACE PROTECTION INDUSTRIES PRODUCT: ZOLATON COLOR: MATCH EXISTING COLOR LOCATION: COLUMN LINE WALLS E PAINT MFG: SHERWIN WILLIAMS COLOR: SW6055 FIERY BROWN FINISH: SEMI—GLOSS LOCATION: ACCENT P5 PAINT MFG: DURON COLOR: 8661W LIGHT ALMOND FINISH: SEMI—GLOSS LACQUER LOCATION: DOORS E PAINT MFG: SHERWIN WILLIAMS COLOR: SW6386 NAPERY FINISH: SATIN LOCATION: RECEPTION/CONF. ROOM PLASTIC LAMINATES Pu PLASTIC LAMINATE MFG: NEVAMAR COLOR: SILVERLINE HAUTELINK HLT004T FINISH: TEXTURED LOCATION: HORIZONTAL SURFACES PL2 PLASTIC LAMINATE MFG: NEVAMAR COLOR: SPA WHITE S -7-40T FINISH: TEXTURED LOCATION: VERTICAL SURFACES Owner: !i CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 @Copyright 2004 Project: LACE RENOVATION SEVEN PARKWOOD 280 E. 96TH ST. INDIANAPOLIS, INDIANA 46240 Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. DnxYnO Title: REFLECTED CEILING/FINISH PLAN Revisions: 10/5/04 PRICING SET 10/19/04 ADD 10 10 20 04 ADD 2 0 12/3/04 CONSTRUCTION SETD Issue Date Drawn By Checked By 9/21/04 MC MC a� ` A STATE OF HIL 9 Drawing Number: A202 Project Number: LACE 04 r e 3'-0" S-3" 1. 9/21/44 fr 2ND FLOOR ELECTRICAL/DA SCALE: 1/8"=l'—O" TA PLAN NORTH 1/4" CLEAR TEMPERED GLASS IN 2" BRUSHED ALUMINUM FRAMEWORKS FRAME. 2'-113/x" 2'-113/," / 2'-11%" 1. 1. 2'-11-" A RECEPTION 2000 1 ELEVATION A203 J SCALE: 1/2" = 1'-0" REFRIGERATOR 6 N GENERAL ELECTRICAL/DATA NOTES: 1. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED © 18" AFF UNLESS NOTED OTHERWISE. 2. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. 3. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO MATCH COLOR OF COVER PLATES SIMILAR COLORED WALLS. 4. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN -BUILD CONTRACTOR PRIOR TO INSTALLATION. 5. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. 6. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. 7. ELECTRICAL CONTRACTOR TO COORDINATE FURNITURE SUPPLIERS BASE POWER/DATA FEED AND/OR POWER POLES. COORDINATE ELECTRICAL LOCATIONS AND CIRCUITING REQUIREMENTS WITH TENANT AND/OR FURNITURE DEALERSHIP. ELECTRICAL CONTRACTOR TO HARDWIRE FURNITURE SYSTEM TO BUILDING POWER SOURCE. ELECTRICAL/DATA PLAN NOTES: EPS PROVIDE DEDICATED POWER FOR PLOTTER. ELECTRICAL CONTRACTOR TO VERIFY POWER REQUIREMENTS WITH TENANT EQUIPMENT. S-3" 3'-0" S-3" Checked By 9/21/44 MC MC —1 — r ' t -L — — r`. W GENERAL ELECTRICAL/DATA NOTES: 1. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED © 18" AFF UNLESS NOTED OTHERWISE. 2. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. 3. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO MATCH COLOR OF COVER PLATES SIMILAR COLORED WALLS. 4. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN -BUILD CONTRACTOR PRIOR TO INSTALLATION. 5. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. 6. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. 7. ELECTRICAL CONTRACTOR TO COORDINATE FURNITURE SUPPLIERS BASE POWER/DATA FEED AND/OR POWER POLES. COORDINATE ELECTRICAL LOCATIONS AND CIRCUITING REQUIREMENTS WITH TENANT AND/OR FURNITURE DEALERSHIP. ELECTRICAL CONTRACTOR TO HARDWIRE FURNITURE SYSTEM TO BUILDING POWER SOURCE. ELECTRICAL/DATA PLAN NOTES: EPS PROVIDE DEDICATED POWER FOR PLOTTER. ELECTRICAL CONTRACTOR TO VERIFY POWER REQUIREMENTS WITH TENANT EQUIPMENT. S-3" 3'-0" S-3" Checked By 9/21/44 MC MC —1 — — �— -L — — — — 'IF � \� I I i� T=7_\ COFFEE MICROWAVE BREAK AREA 2002 2 ELEVATION A203 J SCALE: 1/2" = 1'-0" PLASTIC LAMINATE UPPER CABINETS W/(2) ADJUSTABLE SHELVES AND 4" WIRE PULLS. FINISH PL2. SINGLE BOWL STAINLESS STEEL SINK W/GOOSENECK FAUCET AND BLADE CONTROLS. 3/4" PLASTIC LAMINATE COUNTER W/1-1/2" LIP AND 4" BACK SPLASH. FINISH PL1. PLASTIC LAMINATE BASE CABINETS W/DRAWERS, (1) ADUSTABLE SHELF, AND 4" WIRE PULLS. FINISH PL2. PLASTIC LAMINATE SINK BASE W/FULL CLEARANCE INSIDE, RETRACTABLE DOORS, AND 4" WIRE PULLS. FINISH PL2. ELECTRICAL/DATA LEGEND: DUPLEX WALL OUTLET. QUADRAPLEX WALL OUTLET. �D DEDICATED CIRCUIT OUTLET. dGFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. DUPLEX RECEPTACLE AND DUPLEX DATA OUTLET IN COMBINATION COVER MOUNTED IN SURFACE RACEWAY. (1) JUNCTION BOX FOR SYSTEM FLEX CONDUIT POWER FEED TO WORKSTATION RACEWAY. (1) 2 -GANG JUNCTION BOX FOR (2) 3/4 FLEX CONDUIT DATA FEEDS TO WORKSTATION RACEWAY. V PHONE/DATA WALL OUTLET (BOX AND PULL STRING). V TELEPHONE WALL OUTLET (BOX AND PULL STRING). FLOOR MOUNTED TOMBSTONE/FLUSH MOUNT DUPLEX OUTLET. FLOOR MOUNTED TOMBSTONE/FLUSH MOUNT TELEPHONE OUTLET. JUNCTION BOX. N DENOTES NEW OUTLET LOCATION. +44" HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. ADJUSTABLE SHELVES 3 ELEVATION A203 J SCALE: 1/2" = 1'-0" EXISTING ADJUSTABLE SHELVING. 12"d WOOD SHELVES W/ 1-1/2" WOOD TRIM EDGE. TO MATCH ADJACENT SHELVES. (BY OWNER) "RAKKS" - "C" STANDARDS . RECESS INTO G.W,B, PROVIDE ACCESS SLOT 0 BOTTOM OF STANDARDS. BRACKET TO BE "RAKKS" BR -012. TO MATCH ADJACENT STANDARDS AND BRACKETS. (SUPPLIED BY 'BWNER, INSTALLED BY GC) CSOI Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 Wapyright 2004 Project: LACE RENOVATION SEVEN PARKWOOD 280 E. 96TH ST. INDIANAPOLIS, INDIANA 46240 Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. (I Drawing Title: I ELECTRICAL/ DATA PLAN Revisions: 10/5/04 PRICING SET .10/19/04 ADD 1 10/20/04 ADD 2A, 12/3/04 CONSTRUCTION SET Issue Date Drawn By Checked By 9/21/44 MC MC S-3" IL S-0� 0- S-3�-3' BREAK AREA 2002 2 ELEVATION A203 J SCALE: 1/2" = 1'-0" PLASTIC LAMINATE UPPER CABINETS W/(2) ADJUSTABLE SHELVES AND 4" WIRE PULLS. FINISH PL2. SINGLE BOWL STAINLESS STEEL SINK W/GOOSENECK FAUCET AND BLADE CONTROLS. 3/4" PLASTIC LAMINATE COUNTER W/1-1/2" LIP AND 4" BACK SPLASH. FINISH PL1. PLASTIC LAMINATE BASE CABINETS W/DRAWERS, (1) ADUSTABLE SHELF, AND 4" WIRE PULLS. FINISH PL2. PLASTIC LAMINATE SINK BASE W/FULL CLEARANCE INSIDE, RETRACTABLE DOORS, AND 4" WIRE PULLS. FINISH PL2. ELECTRICAL/DATA LEGEND: DUPLEX WALL OUTLET. QUADRAPLEX WALL OUTLET. �D DEDICATED CIRCUIT OUTLET. dGFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. DUPLEX RECEPTACLE AND DUPLEX DATA OUTLET IN COMBINATION COVER MOUNTED IN SURFACE RACEWAY. (1) JUNCTION BOX FOR SYSTEM FLEX CONDUIT POWER FEED TO WORKSTATION RACEWAY. (1) 2 -GANG JUNCTION BOX FOR (2) 3/4 FLEX CONDUIT DATA FEEDS TO WORKSTATION RACEWAY. V PHONE/DATA WALL OUTLET (BOX AND PULL STRING). V TELEPHONE WALL OUTLET (BOX AND PULL STRING). FLOOR MOUNTED TOMBSTONE/FLUSH MOUNT DUPLEX OUTLET. FLOOR MOUNTED TOMBSTONE/FLUSH MOUNT TELEPHONE OUTLET. JUNCTION BOX. N DENOTES NEW OUTLET LOCATION. +44" HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. ADJUSTABLE SHELVES 3 ELEVATION A203 J SCALE: 1/2" = 1'-0" EXISTING ADJUSTABLE SHELVING. 12"d WOOD SHELVES W/ 1-1/2" WOOD TRIM EDGE. TO MATCH ADJACENT SHELVES. (BY OWNER) "RAKKS" - "C" STANDARDS . RECESS INTO G.W,B, PROVIDE ACCESS SLOT 0 BOTTOM OF STANDARDS. BRACKET TO BE "RAKKS" BR -012. TO MATCH ADJACENT STANDARDS AND BRACKETS. (SUPPLIED BY 'BWNER, INSTALLED BY GC) CSOI Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 Wapyright 2004 Project: LACE RENOVATION SEVEN PARKWOOD 280 E. 96TH ST. INDIANAPOLIS, INDIANA 46240 Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. (I Drawing Title: I ELECTRICAL/ DATA PLAN Revisions: 10/5/04 PRICING SET .10/19/04 ADD 1 10/20/04 ADD 2A, 12/3/04 CONSTRUCTION SET Issue Date Drawn By Checked By 9/21/44 MC MC 11 Drawing Number: 11 A203 Project Number: LACE 04