Loading...
HomeMy WebLinkAbout04120031 Large Format Plans LARGE FORMAT PLANS 1\\ ARCHITECT: CSO 280 E. 96TH STREET, SUITE 200 INDIANAPOLIS, INDIANA 46240 (317) 848.7800 (377) 574.1869 FAX CONTRACTOR: �6i Duke REALTY CORPORATION 600 E. 96th STREET SUITE 100 INDIANAPOLIS, IN 46240 PHONE: (317)808-6000 INDEX OF DRAWING""S • COVER • A201 CONSTRUCTION PLANS • A601 ELEVATIONS DETAILS ® APPROVED AS SUBMITTED APPROVED AS NOTED 1:1 REJECTED SIGNATURE DATE COMPANY 4TH FLOOR KEYPLAN SCALE: NTS NORTH F- FOUR PARKWOOD SUITE 455 INDIANAPOLIS, INDIANA SPECIFICATIONS AND GENERAL NOTES 0 CONTRACT CONDITIONS 0.1 THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION, ENTITLED 'GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED AS FOLLOWS: 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION. 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND WORKMANSHIP. 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 0.2 WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, RULES AND REGULATIONS. 0.3 ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. 0.4 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. 0.5 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL GOVERN THE WORK. 0.6 NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT N01 CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. 0.7 INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 1 GENERAL REQUIREMENTS 1.1 WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANA01MENT. 1.2 THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA SECURITY, FURNITURE AND 'FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. 1.3 CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS kiD WORKMANSHIP. 1.4 SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITEC FOR THE FOLLOWING ITEMS: .1 METAL FABRICATIONS. .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. .3 DOORS, FRAMES AND HARDWARE. .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL PANEL ). .5 VCT FLOORING AND BASE ( COLOR SAMPLES ). .6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ). .7 PAINT ( 6" X 6' ON ACTUAL SURFACE ). .8 WALLCOVERINGS ( 9° X 9° DYE LOT CUTTING ). .9 SIGNAGE ( SAMPLE SIGN ). .10 LIGHT FIXTURES ( CATALOG CUTS ). 1.5 TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, TEMPORARY ENCLOSURES, ARE PROTECTION, HEAT AND POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNIR'S AGENT. 1.6 THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. 1.7 THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS CONTRACT EXITS, EXIT UGHTING, ARE PROTECTIVE DEVICES AND ALARMS TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. 1.8 SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDE COMPLETE PRODUCT DATA DRAWINGS AND DESCRIPTIONS OF PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO ACCOMMODATE THE SUBSTITUTION. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL AFFECT THE CONTRACT SUM AND CONTRACT TIME. 1.9 STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THOR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. 1.10 THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. 1.12 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 5 5.1 6 6.1 6.2 6.3 6.4 6.5 6.6 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL 6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR 12 FURNISHINGS CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, EXPECTED FROM A COMMERCIAL BUILDING CLEANNG AND MAINTENANCE 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, REINSTALL SUCH ITEMS. 12.1 CASEWORK: PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND OPERATING FOR TEN DAYS. SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD FOLLOWING: MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND FOR THE VARIOUS SUBSTRATES, AS INDICATED. .1 IMPERIAL CABINET CO., INC. THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE STRAIGHT WITH NO DISTORTIONS. .2 MERILLAT INDUSTRIES, INC. INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM 1. FERROUS METAL: .3 YORKTOWNE CABINETS PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. WIDTH NOT TO EXCEED 1/8 U.O.N. A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC 15/16 MECHANICAL AND ELECTRICAL DEMOLITION OUTLETS. LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ,',NYUC 15/16.1 MECHANICAL (INCLUDING PLUMBING, ARE PROTECTION AND HVAC) AND COORDINATE DEMOLITION WITH CONSTRUCTION PUNS TO DETERMINE SEMI -GLOSS ENAMEL. ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE 7 JOINT SEALERS 2. NON-FERROUS METAL RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC WORK. 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT, THE CONTRACTOR SHALL WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR AND FIXTURES: LATEX PRIMER. BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, .1 "DOW CORNING 786"; DOW CORNING CORP. 2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION .2 "SCS 1702 SANITARY"; GENERAL ELECTRIC CO. SEMI -GLOSS FINISH ELECTRICAL SYSTEMS. TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND .3 "863 1345 WHITE'; PECORA CORP. 3. FERROUS STRUCTURE: 15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING .4 "PROGLAZE WHITE'; TREMCO CORP. A. ACRYLIC DRY FOG FLAT FINISH: DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND ADJACENT SURFACES, INCLUDING WITH REGARD TD MATERIALS AND .5 "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED REDUCIBIR ACRYLIC DRY FOG COATING CERTIFIED ENGINEER. TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR 7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING 4. NON-FERROUS STRUCTURE: 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. SURFACES: A. ACRYLIC DRY FOG FLAT FINISH: DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED .1 "CHEM -CALK 600°; BOSTIK CONSTRUCTION PRODUCTS DIV. 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL .2 "AC -20"; PECORA CORP. REDUCIBLE ACRYLIC DRY FOG COATING. AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL BE INCLUDED. .3 SONOLAC ; SONNEBORN BUILDING PRODUCTS 8, WOOD: DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE .4 "FREMCO ACRYLIC LATEX 834"; TREMCO, INC. A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. DRAWINGS. 1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX 15/16.4 SUBMIT ARE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE 8 DOORS AND WINDOWS PRIMER -SEALER. OWNER OR THE OWNER'S AGENT, PATTERN OF SPRINKLER LAYOUT ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS SEMI -GLOSS ENAMEL COORDINATE WITH OTHER CEILING COMPONENTS. METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. B. STAIN -VARNISH RUBBED FINISH: 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS FINISHES. 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED 1. FILLER: 1 COAT 14800 WONDER WOODSTAIN SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. PASTE WOOD FILLER (OPEN GRAIN WOODS). OWNER'S AGENT. REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH 2. STAIN: 1 COAT 196XX WONDER WOODSTAIN 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED NOTED TO BE REPAIRED. AND LOCKSETS. ALKYD STAIN. WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 3. SEALER: 1 COAT #4900 WONDER WOODSEALER VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. QUICK DRY SEALER. EQUIPMENT. REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK 4. FINISH: 2 COATS #4600 WONDER WOODSTAIN 15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE IN SCOPE OF CONTRACT. 9 FINISHES ALKYD SATIN VARNISH. GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING 10. GYPSUM WALLBOARD: 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. A. ACRYLIC LATEX SATIN ENAMEL FINISH: INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS 1. PRIMER: 1 COAT #50801 WONDER TONES LATEX COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT .1 INSTALL 'ELIMINATOR" TYPE HEAD TRACK AT WALLS TERMINATING PRIMER -SEALER. TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. AT CEILING. USE PREFORMED OUTSIDE CORNERS. 2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC INSTALLATION SHALL OCCUR. CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES LATEX SATIN ENAMEL 15/16.9 DIMENSIONS IF IDENTIFIED ARE TO CENTERLINE OF OUTLET OR GANG OF AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY 9.2 GYPSUM BOARD: PROVIDE 5/8° THICK REGULAR AND TYPE "X' TAPERED 13. PRECAST CONCRETE: OUTLETS, UNLESS OTHERWISE NOTED. SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE- EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS) 15/16.10 ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE 1. PRIMER: 1 COAT #1502 WONDER -SHIELD ACRYLIC CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. LATEX HOUSE PAINT PRIMER. COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE IVORY. DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS 2. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX 15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY PLUMBING, HVAC, ELECTRICAL, AND ARE PROTECTION SYSTEMS. .1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED TEXTURE COATING. SHALL BE DATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH PROVIDING PROPER ACCESS TO RECEPTACLES. RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT" SET. MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA- 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND 9,11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND FOR SPECIFIC LOCATION. SETTLEMENT OR COLLAPSE OF STRUCTURE OR E17MENT TO BE FINISHING OF GYPSUM BOARD. WITHOUT WRINKLES, GAPS OR OVERLAPS. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET DEMOLISHED, AND ADJACENT FACILITIES OR WORk TO REMAIN. LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL TRUE AND FREE FROM .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN" METAL FABRICATIONS DAMAGED OR SOILED TILES. r ACCEPTABLE. CONSTRUCTION. .2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CORNERS AND 6" F PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS OUTSIDE CORNERS. OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL 4GN GENERAL NOTES REQUIRED TO COMPLETE WORK. REFLECTED CEILING PLAN SHALL GOVERN. 10 SPECIALTIES .2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND WOOD AND PLASTIC LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS 10.1 FIRE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO _ UNLESS NOTED OTHERWISE. BUILDING STANDARD, PROVIDE JL INDUSTRIES "AMBASSADOR" SERIES, PROCEEDING WITH CONSTRUCTION, CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE 'CONSTRUCTION SEMI RECESSED, DUO -PANEL, FIELD PAINTED. 4 GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: GRADE' LUMBER Of ANY SPECIES WITH MAXIMUM 19% MOISTURE 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CONTERUNE OF DOOR OR CONTENT. CASED OPENING UNLESS NOTED OTHERWISE. A. TO FINISHED FACE OF GYPSUM BOARD. PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE 1 INSTALL JOHNSONfTE TRIM STRIPS AT DOOR WHERE CARPETx B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA' C. TO TOP Of FINISHED FLOORS. C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32 MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCHCARPET D. TO BOTTOM OF FINISHED CEILINGS. FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND ro PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH 9.6 RESILIENT FLOORING: EXISTING CONSTRUCTION AND WALL TYPES. CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING ' P GN.4 TERMINATE WALLS AT UNDERSIDE Of CEILING UNLESS INDICATED JURISDICTION. .1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS s .r OTHERWISE FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT GN.S DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO STANDARDS. LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS AVOID USE OF CUT WIDTHS LESS THAN 3 AT ROOM PERIMETER. SHALL BE AS SHOWN ON CONSTRUCTION PLAN, IN CASE OF CONFLICT, .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR 2 BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING TO FABRICATION OF MULTIPLE UNITS. BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING = WITH CONSTRUCTION. ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS, GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS). 9.7 USE AN APPROVED CEMENTTTIOUS FILLER TO PATCH CRACKS, SMALL DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM OBSERVATION. 1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACE VARIATION OF '4" IN 10 FEET, NON -CUMULATIVE. FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT SURFACES. LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT .2 PROVIDE 2' DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0" NON- ELECTRICAL OR DATA OUTLET LOCATIONS. 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING _ CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. STANDARDS:GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 4006 FOR ` _ CLOSE -IN OF WALLS. PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. FLAMMABILITY: ASTM 2859 GN.9 SOUND INSULATED AND ARE RATED PARTITIONING SHALL BE CAULKED AT SURFACE BURNING: ASTM E84 PERIMETER WITH ACOUSTICAL OR ARE RATED SEALANT AS APPLICABLE. .1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: SMOKE DENSITY: ASTM E662 PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 SOUND ABSORPTION: ASTM C423 - w. `, PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED (0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL FADE RESISTANCE AATCC 16E -. TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL THICKNESS). STATIC RESISTANCE: AATCC 134 JUNCTION BOXES ARE NOT PERMITTED. .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. WARRANTY: 10 YEARS i ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY .3 CABINET HARDWARE SCHEDULE:"` „ . TENANT. " .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. .1 HINGES: FULLY CONCEALED, SELF-CLOSING 1000 SERIES" BY GRASS OR EQUALS .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER, t l: #4483 OR EQUAL AS MANIFACTURED BY STANLEY. .3 CABINET CATCHES: ADJUS[ABLE MAGNETIC CATCHES WITH MINIMUM 8 LBS. PULL; SP 45 OR SP 46 OR EQUAL AS MANUFACTURED BY STANLLY. .4 DRAWER GLIDES: SIDE AID BOTTOM MOUNTED SLIDES WITH POSITIVE STOP AND LOCKOUT POSITION, WITH HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS MANUFACTURED BY KNAPE & VOGT. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED -� SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT OR EQUAL 1 � , w r r rac) .. v y C) M �I y 0 r x 0 6 o RY is 0 a m CL �0�`�� q CO o su UJ &0 Z,< <O Cn C7 y CITY OF CARMEL/CLAY TO NSHIP €xR. Dept. of Community Services -- Building & Code Enforcement 1 One Civic Square 1.1' Floor; Carmel, IN 46032 PLAN AUTHENTICATION CERTIFICATIONS AND AGREE AW f 4 As the authorized agent responsible for obtaining a permit or permits', I certify that these plans %- ' are IDENTICAL to those released for construction by the Indiana Depart. of Fire & Building it Services. I also understand that if it is determined that these plans are not identical, a STOP WORK ORDER willbe served, s required under the Ordinances referenced below. - Authorized Signature Printed Name ` 'Required under Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.4.2 and Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township Zoning Ordinance, Section 31.1 entitled "Violations and Penalties". S:Permits /Forms /AuthentStickerll-O] m dfIMlflp�� 74 :STATE OF -`Hi,�; nfffOffot� 11/22/04 CSO #24367 i GENERAL CONSTRUCTION NOTES: A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER- DO NOT SCALE DRAWINGS. B. PROVIDE WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. C. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). D. REFER TO CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. E. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. F. APPLY SEALANT AT ALL PLUMBING FIXTURES AT JUNCTURE WITH WALL AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. G. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION H. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR UNLESS NOTED OTHERWISE TO MEET CURRENT ADA CODE REGULATIONS I. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. J. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. K. BUILDING OWNER TO PROVIDE MINIBLINDS AT ALL PERIMETER WINDOWS. EXISTING MINIBLINDS TO BE CLEANED AT COMPLETION OF CONSTRUCTION. L. ALL NEW FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY. M. ALL NEW WORKSURFACES TO RECEIVE 2-1/2" GROMMETS. NEW GROMMET LOCATIONS TO BE VERIFIED WITH TENANT IN FIELD AND WITH RESPECT TO NEW ELECTRICAL LAYOUT CONSTRUCTION PLAN NOTES: 4TH FLOOR DEMO/CONSTRUCTION PLAN �' ALIGN FINISHED FACES. SCALE: 1/8" = 1'-0" FPz CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION NORTH FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 8/A601. (s REMOVE SECTION OF WALL AND PREP FOR NEW DOOR OPENING. 9 REMOVE ELECTRICAL/DATA OUTLET AND PREP FOR NEW FINISHES. 3'-0" 1'-5" 3'-0" 3'-0" FPS NEW RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. co Co FPs PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE MAKER/REFRIGERATOR. VERIFY EXACT LOCATION OF ALL APPLIANCES, REQUIRING A WATER SOURCE WITH TENANT. UNDERCOUNTER GARBAGE DISPOSAL TO BE PROVIDED AND INSTALLED BY G.C. �7 REQUIREMENTSTOPRIDEPOMNOURCEFQRAUL E DISPOSAL. VERIFY ELECTRICAL EU GARBAGE co REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER FPs G.C.R WORKING ORDER AALL TENANT D SIS NOTLEAKING BEFORE TURNINGTOUNITONFIRM OVER TO UNIT TENANT. D1 D2 D3 DOORFRAME ELEVATION �01 SCALE: 1/4" = 1'-0" 4TH FLOOR REFLECTED CEILING SCALE: 1/8" = 1'-0" GENERAL CEILING NOTES: A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWISE NOTED. B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. D. MECHANICAL AND ELECTRICAL IS DESIGN -BUILD. DESIGN -BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN -BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR AESTHETIC REVIEW ONLY. F. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING. GENERAL CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION. G. RE -USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED, RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION. H. CEILING HEIGHT IS 8'-8" A.F.F. UNLESS OTHERWISE NOTED. CEILING PLAN NOTES: cPi NEW GYPSUM BOARD CEILING SOFFIT TO ALIGN WITH MILLWORK COUNTER CONSTRUCTION PLAN LEGEND: NOTES: _ _ = EXISTING CONSTRUCTION TO BE REMOVED EXISTING PARTITION TO REMAIN NEW WALL PARTITION ® NEW LOW WALL PARTITION W1 2-1/2" 25 GAUGE METAL STUDS @24-O.C. WITH 5/8 GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. W2_2-1/2" 25 GAUGE METAL STUDS ®24"O.C. M WITH 5/8" GYPSUM WALL BOARD EACH M SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE 2 1/2" SOUND INSULATION IN HORIZONTAL SURFACE ABOVE CEILING AND INSIDE WALL. INSULATION TO EXTEND 2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF WALL. W3 NEW LOW WALL CONSTRUCTION TO BE 42" A.F.F.: 2-1/2" 25 GAUGE METAL STUDS 016-O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO +42" A.F.F. PROVIDE WOOD CAP TO BE STAINED TO MATCH DOOR STAIN DENOTES AREA NOT IN CONTRACT DENOTES NEW MILLWORK FMhNEW DOOR AND FRAME. REFER TO DOOR SCHEDULE EXISTING DUPLEX WALL OUTLET TO BE DEMOLISHED EXISTING IN -FLOOR DUPLEX OUTLET TO BE DEMOLISHED �a EXISTING IN -FLOOR TELEPHONE OUTLET TO BE DEMOLISHED P2 P2 P2 CONFERENCE ROOM OFFICE OFFICE 402 403 F4041 ,r C2 B1 Q 61 C2 _ - B1 P1 P1 P1 V 1 OF3 VCT2 ` OPEN OFFICE O 62 PL1 401 BREAK f 405 62 C1 B1 P2 B1 F` P1 S P1 P1 RECEPTION 400 F1 C 1 TP, =L1 ` ST1 `F2 FINISH PLAN NOTES: 4TH FLOOR F1 ALIGN FLOOR TILE WITH GYPSUM BOARD CEILING ABOVE. FINISH PLAN F2 FINISH NEW WALLS WITH WALLCOVERING TO MATCH EXISTING CORRIDOP WALLCOVERING. SCALE: 1/8" = 1'-0" NORTH F3 FLOOR TILE TO BE INSTALLED IN A 12"x12" CHECKERBOARD PATTERN. GENERAL FINISH NOTES: A. ALL NEW DOORS TO BE FINISHED TO MATCH BUILDING STANDARD. B. ALL DOOR FRAMES TO BE FINISHED TO MATCH BUILDING STANDARD. C. ALL WOOD TRIM TO BE STAINED TO MATCH DOORS, UNLESS NOTED OTHERWISE. D. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF ARCHITECT. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. E. CARPET TO CARPET ANDOR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS R QUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH TRANSITION FROM FINISH TO FINISH F. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPETS IN PROJECT SCOPE FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING INSTALLATION. G. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND VINYL TILE TRANSITIONS TAKE PLACE. H. VERIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS. IF NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD. I. PAINT NEW PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT, COLOR TO MATCH ADJACENT WALL FINISH. J. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK, TO ARCHITECT AND/OR DESIGNER FOR REVIEW AND APPROVAL, BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. K. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. L. PAINT ALL EXPOSED METAL SURFACESie. GRILLS HEATERS, AND FIRE EXTINGUISHER CABINETS) TO MATCH AD AGENT SURFACE. DOOR SCHEDULE NEW BUILDING STANDARD CEILING MTD. EXIT LIGHT Architecture DOOR CARPET - DIRECT GLUEB1 FRAME HARDWARE SIZE To NEW DIMMER SWITCH NL NIGHTLIGHT LOCATION PATTERN: EDGE N COLOR: 47 BROWN U W = Q Z J Q Z O J Q Z O J C.D aC O �a_U)V)o 12 Z m CARPET - DIRECT GLUE J CO) QZ W Q PAINT Q UOQOn �c�r�avo W O ~ �_ U U LL LL_ ES W FW— W II II II 11 II O Z ft� VINYL COMPOSITION TILE = F- W A201 W _j 400 RECEPTION 3'-0" 8'-0" 1 3/4" WD/GL D1 MTL D1 L,DB,S,CL 402 CONFERENCE 3'-0" 8'-0" 1 3/4" WD/GL D2 MTL D2 PS,S 403 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D3 MTL D3 L,S 404 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D3 MTL D3 L,S 405 BREAK 3'-0" 8'-0" 1 3/4-1 WOOD I D3 I MTL I D3 PS,S DOOR SCHEDULE NOTES 1. ALL NEW DOORS ARE TO BE STAINED TO MATCH DESIGNER'S SAMPLE 2. ALL METAL DOOR FRAMES ARE TO BE PAINTED P1 3. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD 4. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 5. COORDINATE KEYING LOCKSETS WITH TENANT. REFLECTED CEILING LEGEND: -D EXISTING 2' X 4' FLUORESCENT FIXTURE TO BE REMOVED NEW OR RELOCATED 2' X 4' FLUORESCENT FIXTURE, TO MATCH BUILDING STANDARD. NEW 2' X 2' FLUORESCENT FIXTURE, TO MATCH BUILDING STANDARD. :K NEW BUILDING STANDARD DOWNLIGHT FIXTURE. NEW PENDANT LIGHT FIXTURE TO BE: LBL LIGHTING VENETO, MODEL #HS317-AM-SC-2J-100 (SIZE: 16 1/2" X 4 1/2") 4TH FLOOR ELECTRICAL/DATA PLAN SCALE: 1/8" = V-0" NORTH GENERAL ELECTRICAL NOTES: A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. B. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. C. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. D. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO COORDINATE ELECTRICAL LOCATIONS AND CIRCUITING REQUIREMENTS WITH TENANT AND/OR FURNITURE DEALERSHIP FOR SYSTEMS BASE FEED AND/OR POWER POLES. ELECTRICAL CONTRACTOR TO HARDWIRE FURNITURE SYSTEM TO BUILDING POWER SOURCE. E. ALL RECEPTACLES THAT ARE SHOWN DASHED ARE TO BE REMOVED FROM EXISTING WALLS AND SHALL BE PATCHED AND REPAIRED WITH DRYWALL PRIOR TO NEW WALL FINISH. F. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" A.F.F. UNLESS OTHERWISE NOTED. ELECTRICAL PLAN NOTES: E1 PROVIDE DEDICATED POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY POWER REQUIREMENTS WITH TENANT EQUIPMENT. E2 PROVIDE POWER SUPPLY AND HOOK-UP FOR GARBAGE DISPOSAL. VERIFY REQUIREMENTS WITH MANUFACTURERS MANUAL. FINISH LEGEND: FLOORCOVERINGS NEW BUILDING STANDARD CEILING MTD. EXIT LIGHT Architecture W/DIRECTION INDICATION DUAL -LITE. CARPET - DIRECT GLUEB1 EXISTING 2 X 2 LAY -IN GRID SUSPENSION SYSTEM. VINYL BASE -4" COVE BASE NEW TWO WAY SWITCH To NEW DIMMER SWITCH NL NIGHTLIGHT LOCATION PATTERN: EDGE GYPSUM BOARD CEILING 4TH FLOOR ELECTRICAL/DATA PLAN SCALE: 1/8" = V-0" NORTH GENERAL ELECTRICAL NOTES: A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. B. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. C. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. D. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO COORDINATE ELECTRICAL LOCATIONS AND CIRCUITING REQUIREMENTS WITH TENANT AND/OR FURNITURE DEALERSHIP FOR SYSTEMS BASE FEED AND/OR POWER POLES. ELECTRICAL CONTRACTOR TO HARDWIRE FURNITURE SYSTEM TO BUILDING POWER SOURCE. E. ALL RECEPTACLES THAT ARE SHOWN DASHED ARE TO BE REMOVED FROM EXISTING WALLS AND SHALL BE PATCHED AND REPAIRED WITH DRYWALL PRIOR TO NEW WALL FINISH. F. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" A.F.F. UNLESS OTHERWISE NOTED. ELECTRICAL PLAN NOTES: E1 PROVIDE DEDICATED POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY POWER REQUIREMENTS WITH TENANT EQUIPMENT. E2 PROVIDE POWER SUPPLY AND HOOK-UP FOR GARBAGE DISPOSAL. VERIFY REQUIREMENTS WITH MANUFACTURERS MANUAL. FINISH LEGEND: FLOORCOVERINGS BASE Architecture Engineering CARPET - DIRECT GLUEB1 Landscape Architecture VINYL BASE -4" COVE BASE C1 MFG: J & J INDUSTRIES 317.848.7800 FAX 317.574.0957 ®Copyright 2001 MANUFACTURER: JOHNSONITE a� PATTERN: EDGE 0 COLOR: 47 BROWN COLOR: 903 BRANCUSI all \ LOCATION: RECEPTION & OPEN OFFICE62 WOOD BASE -4" 12 STAINED TO MATCH DOORS CARPET - DIRECT GLUE J CO) QZ D MFG: J & J INDUSTRIES PAINT Q to 3:: Z Z (n O PATTERN: TEXTURES COLOR: 8426 CORDUROY P1 MFG: DURON W Mz LOCATION: PRIVATE OFFICES LL LL_ ES COLOR: 8224M BALSAM PARK 0 V �i FINISH: EGGSHELL vcT1 VINYL COMPOSITION TILE AR00910036 1 LOCATION: GENERAL PAINT MFG: ARMSTRONG A201 MFG: DURON Duke Job Number: PATTERN: STANDARD EXCELON P2 COLOR: 8225D AUTUMN WHEAT COLOR: 51869 HUMUS LOCATION: BREAK ROOM FINISH: EGGSHELL LOCATION: ACCENT WALL vCT2 VINYL COMPOSITION TILE MFG: ARMSTRONG PLASTIC LAMINATE PATTERN: STANDARD EXCELON F_P__L1_1 MANUFACTURER: NEVAMAR COLOR: 51868 SMOKEY BROWN COLOR: MANHATTAN GLITZ MH4001T LOCATION: BREAK ROOM FINISH: TEXTURED sT1 FLOOR TILE LOCATION: COUNTERTOP MFG: DALTILE PATTERN: ROCKY MOUNTAIN _P _L2 MANUFACTURER: NEVAMAR COLOR: RM06 NERO COLOR: FOUNDRY S2084T LOCATION: RECEPTION FINISH: TEXTURED GROUT: MAPEI 09 GRAY LOCATION: SUPPORT PANELS ELECTRICAL LEGEND: d) NEW DUPLEX WALL OUTLET. 8D NEW DEDICATED CIRCUIT OUTLET. 0 NEW PHONE/DATA WALL OUTLET (BOX AND PULL STRING). O NEW JUNCTION BOX. 8GFI NEW GROUND FAULT INTERRUPT CIRCUIT OUTLET. +44" HEIGHT TO CENTER OF OUTLET ABOVE FINISHED FLOOR. _' ue rtEALrr t�oRFORA7ION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 51 - I CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 0 a� 0 0 all \ v aD o\ r 12 J CO) QZ Q 4 _ V oQ a Z oo Q to 3:: Z Z (n O I?_ LU 0-o LJ U W Mz u. O Q LL LL_ ES Z Z 0 V �i s L AR00910036 1 STATE pt< �' '9 �' SNA � �•�' Drawing Number: A201 Of Sheets Duke Job Number: 0000 A/E Job Number: 24367 3/4" PLASTIC LAMINATE COUNTER 2'-0' TOP W/1-1/2- LIP AND 4" BACK SPLASH. PL1 1" PLASTIC LAMINATE TAPERED SUPPORT W/HIDDEN CLEAT, o GROMMET, AND ADJUSTABLE GLIDES. °O PL2 t N WOOD BLOCKING. RECEPTION DESK FULL WINDOWS 6 SECTION 3 ELEVATION 3/4" STAINED SOLID WOOD TYPICAL WALL TYPE SCALE: 1/2"=1'-0" �01 TRIM W/ROUNDED EDGES. 6" PREFINISHED ALUMINUM RECEIVER TRIM EQUAL EQUAL PARTIAL HEIGHT WALL W/3/4" TYPICAL AT ALL EXTERIOR "G13,350". FASTEN AT WINDOW SILL & 2'-0" 3'-0" _0= SQUARE NATURAL UPPER STAINED SOLID WOOD FRAMING. STAINED WOOD TOP CAP. SET IN A CONTINUOUS BEAD OF WALLS- 5/8" TYPE X G.W.B. FINISH BELOW EXISTING ACOUSTICAL SEALANT. TRIM COLOR TO CABINETS W/ADJUSTABLE 1/4" STAINED QUARTER -ROUND 6 A601 24"d x 3/4" PLASTIC LAMINATE WINDOW SILL COVER MATCH BLDG. WINDOW MULLIONS. SHELVES AND 4" WIRE PULLS. GLASS STOPS. WWORKSURFACE W/1-1 2" LIP AND LINE OF EXISTING WINDOW SILL BACK SPLASH. PL1o COVER BELOW' - SETTING BLOCK. N _ N — 1/4" CLEAR TEMPERED GLASS. " 0 0 REFRIGERATOR v__ LALI-i is BY TENANT. t PENCIL I RAWER. SINGLE BOWL STAINLESS STEEL SINK W/GOOSENECK FAUCET i N � 0 1741 METAL \\—CONTINUOUS AND BLADE CONTROLS. t M STUD BEAD OF cq ANGIIED EQUAL EQUAL EQUAL ANGLED ACOUSTICAL SEALANT 25"d x 3/4" PLASTIC LAMINATE ` PLASTIC LAMINATE PED STORAGE UNIT 1" PLASTIC LAMINATE TAPERED PLASTIC LAMINATE COUNTER W/1-1/2" LIP AND W/1-1/2" LIP AND FULL END SUPPORT. BY TENANT. SUPPORT. FULL END SUPPORT. TYPICAL WINDOW MULLION %COUNTER 2-1/2" METAL STUDS. PL2 RECEPTION PL2 PL2 8 DETAIL 1 ELEVATION A601 SCALE: 1/2" = 1'-0" A601 SCALE: 1/2"=1'-0" NOTE: FIELD CUT GROMMETS IN COUNTER. G.C. t 5/8" PAINTED GYPSUM BOARD. Y TO COORDINATE EXACT LOCATION WITH TENANT. 1/2"HW 1 /2"CW, & 1-1/4"V r CONNECT TO BUILDING MAINS SINK 2"W TO BUILDING DRAIN TYPICAL PLUMBING CLERESTORY g ISOMETRIC 7 SECTION SCALE: NTS �01 11 �01 SCALE: 1-1/2"=1'-0" 1 " WOOD TOP CAP WITH QUARTER -ROUND TRIM STAINED TO MATCH DOOR STAIN WOOD DOOR W/GLASS INSERT 1/4" CLEAR TEMPERED GLASS AT CONFERENCE ROOM; SOLID IN BRUSHED ALUMINUM WOOD DOOR AT OFFICE. WINDOW FRAMES. 3/4" PLASTIC LAMINATE COUNTER 2'-0' TOP W/1-1/2- LIP AND 4" BACK SPLASH. PL1 1" PLASTIC LAMINATE TAPERED SUPPORT W/HIDDEN CLEAT, o GROMMET, AND ADJUSTABLE GLIDES. °O PL2 t N D4 BACK SPLASH. PL1 _ 4 BACK SPLASH. PL1 NEW TIMBERLAKE CASCADE SQUARE NATURAL BASE CABINETS o o \ W/DRAWER, ADJUSTABLE SHELVES �•, _ _ = i AND 4" WIRE PULLS. NEW TIMBERLAKE BASE CABINET i TO BE MODIFIED TO MEET ADA SINK REQUIREMENTS 2'-0" L 3'-0" BREAK ROOM BREAK ROOM rT ELEVATION 4 ELEVATION A601 SCALE: 1/2"=1'-0" A6Q1 SCALE: 1/2"=1'-0" ED ue REALTY CoaPow►7toN 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 Drawing Number: A601 Of Sheets Duke Job Number: 0000 A/E Job Number: 24367 RECEPTION DESK FULL WINDOWS 6 SECTION 3 ELEVATION SCALE: 1-1/2"=1'-0" �01 SCALE: 1/2"=1'-0" �01 6" 3'-0" EQUAL EQUAL EQUAL D4 BACK SPLASH. PL1 _ 4 BACK SPLASH. PL1 NEW TIMBERLAKE CASCADE SQUARE NATURAL BASE CABINETS o o \ W/DRAWER, ADJUSTABLE SHELVES �•, _ _ = i AND 4" WIRE PULLS. NEW TIMBERLAKE BASE CABINET i TO BE MODIFIED TO MEET ADA SINK REQUIREMENTS 2'-0" L 3'-0" BREAK ROOM BREAK ROOM rT ELEVATION 4 ELEVATION A601 SCALE: 1/2"=1'-0" A6Q1 SCALE: 1/2"=1'-0" ED ue REALTY CoaPow►7toN 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 Drawing Number: A601 Of Sheets Duke Job Number: 0000 A/E Job Number: 24367 RECEPTION DESK FULL WINDOWS 6 SECTION 3 ELEVATION SCALE: 1-1/2"=1'-0" �01 SCALE: 1/2"=1'-0" �01 NEW TIMBERLAKE UPPER NEW TIMBERLAKE CASCADE CABINETS W/ADJUSTABLE 2'-0" 3'-0" _0= SQUARE NATURAL UPPER SHELVES AND 4" WIRE PULLS. CABINETS W/ADJUSTABLE SHELVES AND 4" WIRE PULLS. - co -- _— _ N — REFRIGERATOR v__ LALI-i BY TENANT. SINGLE BOWL STAINLESS STEEL SINK W/GOOSENECK FAUCET AND BLADE CONTROLS. cq 25"d x 3/4" PLASTIC LAMINATE 25"d x 3/4" PLASTIC LAMINATE COUNTER W/1-1/2" LIP AND W/1-1/2" LIP AND %COUNTER D4 BACK SPLASH. PL1 _ 4 BACK SPLASH. PL1 NEW TIMBERLAKE CASCADE SQUARE NATURAL BASE CABINETS o o \ W/DRAWER, ADJUSTABLE SHELVES �•, _ _ = i AND 4" WIRE PULLS. NEW TIMBERLAKE BASE CABINET i TO BE MODIFIED TO MEET ADA SINK REQUIREMENTS 2'-0" L 3'-0" BREAK ROOM BREAK ROOM rT ELEVATION 4 ELEVATION A601 SCALE: 1/2"=1'-0" A6Q1 SCALE: 1/2"=1'-0" ED ue REALTY CoaPow►7toN 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 Drawing Number: A601 Of Sheets Duke Job Number: 0000 A/E Job Number: 24367