Loading...
HomeMy WebLinkAbout04120034 Large Format Plans LARGE FORMAT PLANS '* ,. ARCHITECT: CSO 280 E. 96TH STREET, SUITE 200 INDIANAPOLIS, INDIANA 46240 13171 848.7800 (317) 574.0857 FAX CONTRACTOR: VAI Duke CONSTRUCTION 600 E. 96th STREET SUITE 100 INDIANAPOLIS, IN 46240 PHONE: (317)808-6000 INDEX OF DRAWINGS • COVER • A201 CONSTRUCTION PLAN & ELEVATIONS • A202 REFLECTED CEILING ELECTRICAL PLAN & DETAILS • 401 ELEVATIONS AND DETAILS • A801 FINISH PLAN & ELEVATIONS 0 APPROVED AS SUBYM ❑ A"PRCMED AS NOTED FGECU MOM nur CONPAW KEYPLAN SCALE: NOT TO SCALE HAMILTON CROSSING VI SPECIFICATIONS AND GENERAL NOTES 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 1 1.1 1.2 1.3 1.4 1.5 OR CONTRACT CONDITIONS THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION, ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED AS FOLLOWS: 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION. 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND WORKMANSHIP. 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, RULES AND REGULATIONS. ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTIUZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL GOVERN THE WORK. NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT CLARIFIED BY ADDENDUM, THE BETTER QUAUTY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, GENERAL REQUIREMENTS WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE AND "FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE FOLLOWING ITEMS: .1 METAL FABRICATIONS. .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. .3 DOORS, FRAMES AND HARDWARE. .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL PANEL ). .5 VCT FLOORING AND BASE ( COLOR SAMPLES ). .6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ). .7 PAINT ( 6' X 6' ON ACTUAL SURFACE ). .8 WALLCOVERINGS ( 9' X 9' DYE LOT CUTTING ). .9 SIGNAGE ( SAMPLE SIGN ). .10 LIGHT FIXTURES ( CATALOG CUTS ). TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING CONSTRUCTION RULES PUBUSHED BY THE OWNER OR THE OWNER'S AGENT. THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .2 PROVIDE SAMPLES WHERE APPUCABL.E OR REQUESTED. .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING All CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO ACCOMMODATE THE SUBSTITUTION. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL AFFECT THE CONTRACT SUM AND CONTRACT TIME. STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. 1.12 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 411 5 5.1 6 6.1 6.2 6.3 6.4 6.5 6.6 p •L. Sub1eCt to 'p r®R . �ornrda� °^�sr DFpT of,Sta•a arra ca "�ittl a» RUCT1` C/TY oj: Ci.lco,l M LOcal e o aegulau A4 Lj,N;17-Y J0(!a.9 L v/�� CARMEL, THESE PNHERE ERE CERTIFIED: S HAVE BEEN ACU-Es, -P...C: T-.. :E� ) D GTYI �T tI -EDEPT OF ^t,UN�C„,.. ^ CARMEL rIE D- Fr..; 1 -LE . TNEYASUITE 125 INDIANA :-F,wE��+rriD ,`+::1 ;,(---'//N 1lT1✓ f 1f iS:,ui'. 9 F HALL REGULATIONS OF S 5r=li• &,LO;a,�+,l_ CODES.CITY OF CARMEL/ CLAY TOWNSHI;; IND PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW WORK. WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL BE INCLUDED. REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE DRAWINGS. ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW FINISHES. EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR NOTED TO BE REPAIRED. SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK IN SCOPE OF CONTRACT. PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES AT MAIN SOURCE OR MAN BRANCH WITHOUT DISRUPTING UTILITY SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE - OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS. CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT" SET. PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. METAL FABRICATIONS PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS REQUIRED TO COMPLETE WORK. WOOD AND PLASTIC CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION GRADE' LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE CONTENT. PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32'. FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE' AWI STANDARDS. .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR TO FABRICATION OF MULTIPLE UNITS. COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS). .1 EDGE TREATMENT. SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACES. .2 PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE ELECTRICAL OR DATA OUTLET LOCATIONS. CABINETS: COMPLY WITH Al SECTION 400 AND ITS DIVISION 4008 FOR PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. .1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 (0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL THICKNESS). .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. .3 CABINET HARDWARE SCHEDULE: .1 HINGES: FULLY CONCEALED, SELF-CLOSING "1000 SERIES" BY GRASS OR EQUAL. .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER, #4483 OR EQUAL AS MANUFACTURED BY STANLEY. .3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS MANUFACTURED BY STANLEY. .4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES WITH POSITIVE STOP AND LOCKOUT POSITION, WITH HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS MANUFACTURED BY KNAPE & VOGT. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT OR EQUAL 6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. 6,8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY OPERATING FOR TEN DAYS. 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM WIDTH NOT TO EXCEED 1/8 U.O.N. 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL OUTLETS. 7 JOINT SEALERS 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS AND FIXTURES: .1 "DOW CORNING 786"; DOW CORNING CORP. .2 "SCS 1702 SANITARY"; GENERAL ELECTRIC CO. .3 "863 #345 WHITE"; PECORA CORP. .4 "PROGLAZE WHITE"; TREMCO CORP. .5 "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS 7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING SURFACES: .1 "CHEM -CALK 600"; BOSTIK CONSTRUCTION PRODUCTS DIV. .2 AC -20"; PECORA CORP. .3 "SONOLAC'; SONNEBORN BUILDING PRODUCTS .4 "TREMCO ACRYLIC LATEX 834% TREMCO, INC. 8 DOORS AND WINDOWS 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH AND LOCKSETS. 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. 9 FINISHES 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. .1 INSTALL "ELIMINATOR" TYPE HEAD TRACK AT WALLS TERMINATING AT CEILING. USE PREFORMED OUTSIDE CORNERS. 9.2 GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE 'X' TAPERED EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. .1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA - 216 RECOMMENDED SPECIFICATION FOR THE APPUCATION AND FINISHING OF GYPSUM BOARD. 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM DAMAGED OR SOILED TILES. .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL REFLECTED CEILING PLAN SHALL GOVERN. .2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS UNLESS NOTED OTHERWISE. 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR CASED OPENING UNLESS NOTED OTHERWISE. .1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH CARPET, 9.6 RESILIENT FLOORING: .1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER. .2 BASE: AT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. 9.7 USE AN APPROVED CEMENTITTOUS FILLER TO PATCH CRACKS, SMALL HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM SURFACE VARIATION OF %' IN 10 FEET, NON -CUMULATIVE. 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING STANDARDS: FLAMMABILITY: ASTM 2859 SURFACE BURNING: ASTM E84 SMOKE DENSITY: ASTM E662 SOUND ABSORPTION: ASTM C423 FADE RESISTANCE: AATCC 16E STATIC RESISTANCE: AATCC 134 WARRANTY: 10 YEARS .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR PROTECT HARDWARE, PLATES AND SIMILAR TRIM, AFTER PAINT IS DRY, REINSTALL SUCH ITEMS. .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD FOR THE VARIOUS SUBSTRATES, AS INDICATED. 1. FERROUS METAL: A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT 141702 METALCLAD ACRYLIC LATE( PRIMER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SEMI -GLOSS ENAMEL. 2. NON-FERROUS METAL: A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT 141702 METALCLAD ACRYLIC LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC SEMI -GLOSS FINISH 3. FERROUS STRUCTURE: A. ACRYLIC DRY FOG FIAT FINISH: 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER REDUCIBLE ACRYLIC DRY FOG COATING 4. NON-FERROUS STRUCTURE: A. ACRYLIC DRY FOG FLAT FINISH: 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER REDUCIBLE ACRYLIC DRY FOG COATING. 8. WOOD: A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX PRIMER -SEALER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SEMI -GLOSS ENAMEL B. STAIN -VARNISH RUBBED FINISH: 1. FILLER: 1 COAT #4800 WONDER WOODSTAIN PASTE WOOD FILLER OPEN GRAN WOODS. 2. STAIN: 1 COAT #96XX WONDER WOODSTAIN ALKYD STAIN. 3. SEALER: 1 COAT 14900 WONDER WOODSEALER QUICK DRY SEALER. 4. FINISH: 2 COATS #4600 WONDER WOODSTAIN ALKYD SATIN VARNISH. 10. GYPSUM WALLBOARD: A. ACRYLIC LATEX SATIN ENAMEL FINISH: 1. PRIMER: 1 COAT #50801 WONDER TONES LATEX PRIMER -SEALER. 2. FINISH: 2 COATS #35XX WONDER TONE ACRYUC LATEX SATIN ENAMEL. 13. PRECAST CONCRETE: A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS) 1. PRIMER: 1 COAT #150? WONDER -SHIELD ACRYUC LATEX HOUSE PAINT PRIMER. 2. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX TEXTURE COATING. 9.11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND WITHOUT WRINKLES, GAPS OR OVERLAPS. .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT ACCEPTABLE. .2 SEAMS MUST BE AT LEAST 2" FROM INSIDE CORNERS AND 6' FROM OUTSIDE CORNERS. 10 SPECIALTIES 10.1 ARE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO BUILDING STANDARD, PROVIDE JL INDUSTRIES "AMBASSADOR" SERIES, SEMI RECESSED, DUO -PANEL, FIELD PAINTED. 12 FURNISHINGS 12. 1 CASEWORK CITY OF CARMEL/CLAY T OWN a Enforcement HIP Dept. of Community Services -- Building One Civic Square 1" Floor; Carmel, IN 46032 AUTHENTICATION CERTIFICATIONS AND AGREh M plans ` PLAN le'rvice the authorized oatihose released foronsible construction by the Indiana Depart of Fire & Building IDENTICALthat s. I also understand that if ias relsuired undedr the Ohdinnlcessreferenc dare not ebelow.a STOPORK O DER will be served, q �hie Printed Name uthorized Signature entitled "Building Code" and Section 29.42equired under Chapter 7, Section 10 of the Carmel City Code,nd Section der entitled "Administration". Required byCarmel / CLay Township Zoning Ordinance,Section 1.1 entitled"Violations and Penalties:Permits/Forms/AuthentStickerlI 0 W ZLO =0 U LO i Na � AR00910M } e STATE OF f' ANP .( 11/18/04 CSO #24376 .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: .1 IMPERIAL CABINET CO., INC. .2 MERILLAT INDUSTRIES, INC. .3 YORKTOWNE CABINETS 15/16 MECHANICAL AND ELECTRICAL 15/16.1 MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND ELECTRICAL SYSTEMS. 15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND PLUMBING, SIGNED AND STAMPED FOR STATE RUNG PROCESS BY A CERTIFIED ENGINEER. 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. 15/16.4 SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT SHALL COORDINATE WITH PATTERN OF UGHTING LAYOUT AND SHALL COORDINATE WITH OTHER CEILING COMPONENTS. 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR OWNER'S AGENT. 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED EQUIPMENT. 15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE, DIMMERS SHALL BE GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE INSTALLATION SHALL OCCUR. 15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF OUTLETS, UNLESS OTHERWISE NOTED. 15/16.10 ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE IVORY. 15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL PROVIDING PROPER ACCESS TO RECEPTACLES. 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL FOR SPECIFIC LOCATION. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN' CONSTRUCTION. GN GENERAL NOTES GNA CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO PROCEEDING WITH CONSTRUCTION. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: A. TO FINISHED FACE OF GYPSUM BOARD. B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS, C. TO TOP OF FINISHED FLOORS. D. TO BOTTOM OF FINISHED CEILINGS. GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, EXISTING CONSTRUCTION AND WALL TYPES. GN.4 TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED OTHERWISE. GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION. GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS OBSERVATION. GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0' NON- CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CLOSE -IN OF WALLS, GNA SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT PERIMETER WITH ACOUSTICAL OR FIRE RATED SEALANT AS APPLICABLE. PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED TO STUD FRAMING, AT THESE PARTITIONS, BACK TO BACK ELECTRICAL JUNCTION BOXES ARE NOT PERMITTED. GN.10 ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLED BY TENANT. CITY OF CARMEL/CLAY T OWN a Enforcement HIP Dept. of Community Services -- Building One Civic Square 1" Floor; Carmel, IN 46032 AUTHENTICATION CERTIFICATIONS AND AGREh M plans ` PLAN le'rvice the authorized oatihose released foronsible construction by the Indiana Depart of Fire & Building IDENTICALthat s. I also understand that if ias relsuired undedr the Ohdinnlcessreferenc dare not ebelow.a STOPORK O DER will be served, q �hie Printed Name uthorized Signature entitled "Building Code" and Section 29.42equired under Chapter 7, Section 10 of the Carmel City Code,nd Section der entitled "Administration". Required byCarmel / CLay Township Zoning Ordinance,Section 1.1 entitled"Violations and Penalties:Permits/Forms/AuthentStickerlI 0 W ZLO =0 U LO i Na � AR00910M } e STATE OF f' ANP .( 11/18/04 CSO #24376 TYPICAL WALL TYPE— TYPICAL AT ALL EXTERIOR WALLS- 5/8" TYPE X G.W.B. FINISH BELOW EXISTING WINDOW SILL COVER PREFINISHED ALUMINUM RECEIVER TRIM "GB350". FASTEN AT WINDOW SILL & SET IN A CONTINUOUS BEAD OF ACOUSTICAL SEALANT. TRIM COLOR TO MATCH BLDG. WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW METAL .STUD CONTINUOUS BEAD OF ACOUSTICAL SEALANT WINDOW MULLION DETAIL A201 SCALE: 1/2"= 1'-0" 1 /2"HW, 1 /2"CW, & 1-1/4"V SII I � i I I CONNECT TO RI III IANC, I iwo, PLUMBING 2 ISOMETRIC A201 SCALE: 1/2"= 1'-0" 2"W TO BUILDING DRAIN DOOR SCHEDULE fl. PILL VYMLLJ OFWALL UL \,"MULRLV VI I I VR ULJIVI9LR J RLVILVV Ur Nr VV WALL LUllJIKU(JIIUN DOOR I. FRAME .)k nrUULt HARDWARE REMARKS SIZE FAX 317.574.0957 ®Copyright 2001 CD — WITH 5/8" GYPSUM WALL BOARD EACH "� J. t MY SIDE. WALLS TO EXTEND TO 10'-0" AND BRACE TO STRUCTURAL BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARTION FOR NEW FINISHES. DECK ABOVE. PROVIDE 2 .1/2" SOUND INSULATION IN HORIZONTAL LLJ � FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR SURFACE ABOVE CIELING AND INSIDE WALL. INSULATION TO EXTEND 0 af FINISHES AS SCHEDULED. 2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF WALL. U F— OO �i � BUILDING OWNER AND/OR G.C. TO PROVIDE MINISBUNDS AT ALL PERIMETER O o C-� WINDOWS. EXISTING MINIBLINDS TO BE CLEANED AT COMPLETION OF CONSTRUCTION. DENOTES AREA NOT IN CONTRACT M. ALL NEW AND EXISTING FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING HARDWARE IL CO) TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE Z Z z �o�� N ZmLai om N OF AESTHETIC PURPOSES ONLY. 0 OO N. EXISTING DOORS AND DOOR FRAMES TO BE REUSED DURING CONSTRUCTION o NEW DOOR AND FRAME, REFER TO DOOR SCHEDULE >¢ DOORS THAT ARE QUESTIONABLE FOR REUSE, PLEASE CALL FOR DESIGNERS hhft111NN��o 41, Drawing Number: REVIEW AND APPROVAL OF REUSE BEFORE INSTALLATION. o w ALL NEW WORKSURFACES TO RECIVE 2-1/2" GROMMETS. NEW GROMMET LOCATIONS 24376 9 Q u u n u n u CONSTRUCTION PLAN NOTES: O Z p0 U Q FP1 ALIGN FINISHED FACES. _ F- FP2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS W =LV J V)___1 m L� J(nO_UnU) 100A LOBBY Iw EXISTING TO REMAIN 1008 LOBBY 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 SF,S 101 CONFERENCE S-0" 8'-0" 1 3/4" WOOD D3 HM D3 L,S FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MFG. MANUAL. 103 CONFERENCE 3'-0" 8'-O" 1 3/4" WOOD D3 HM D3 PS,S 104 CONFERENCE S-0" 8'-0" 1 3/4" WOOD D3 HM D3 PS,S 105 OFFICE S-0" 8'-0" 1 3/4" WOOD D2 HM D2 L,S 106 OFFICE S-0" 8'-0" 1 3/4" WOOD D2 HM D2 L,S 107 OFFICE S-0" 8'-O" 1 3/4" WOOD D2 HM D2 L,S 108 CONFERENCE 3'-0" 8'-0" 1 3/4" WOOD D3 HM D3 PS,S 110 FILE/EQUIP. 3'-0" 8'-0" 1 3/4" WOOD D4 HM D4 SF,S 113 OPEN OFFICE 4'-0" 8'-O" 1 3/4" WOOD I D5 HM D5 L,S,CL,SF 90 MIN. RATED DOOR DOOR SCHEDULE NOTES 2. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD WHERE NEEDED. 3. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 4. COORDINATE KEYING LOCKSETS WITH TENANT. w �z o O I >_ co o X �(n f):fz 0 O U Uj �o om A 1 n)1 ,0 n)1 WELDED FRAME 1/4" TEMPERED SIDELIGHT LEVER c HARDWARE « D1 DOOR ELEVATIONS SCALE: 1/411= 1'-0" n .- WALL LEGEND: GENERAL CONSTRUCTION NOTES: NOTES: _ _ = EXISTING CONSTRUCTION TO BE REMOVED A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS EXISTING PARTITION TO REMAIN NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE NEW WALL PARTITION TO BE VERIFIED BY DESIGNER- DO NOT SCALE DRAWINGS. NOTE: ALL NEW WALLS ARE TO BE W1 UNLESS NOTED OTHERWISE. B. PROVIDE WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. C. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN W1 3-5/8" 25 GAUGE METAL STUDS 024"O.C. , ; ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). WITH 5/8" GYPSUM WALL BOARD EACH M D. REFER TO CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE E. REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH 2 1/2" SOUND INSULATION IN HORIZONTAL SURFACE ABOVE WITH ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE. CEILING AND INSIDE WALL. INSULATION TO EXTEND 2'-0" IN F. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. BOTH DIRECTIONS FROM CENTER LINE OF WALL. t)I11I 11 `L1 L ') ` '/'L VII JVIYI I�P\LL UVP11\U 2HR RATED fl. PILL VYMLLJ OFWALL UL \,"MULRLV VI I I VR ULJIVI9LR J RLVILVV Ur Nr VV WALL LUllJIKU(JIIUN EACH SIDE. UL -0419 I. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE .)k nrUULt FRAME OF DOOR UNLESS NOTED OTHERWISE TO MEET CURRENT ADA CODE REGULATIONS W3 3-5/8" 25 GAUGE METAL STUDS 024"O.C. FAX 317.574.0957 ®Copyright 2001 CD — WITH 5/8" GYPSUM WALL BOARD EACH "� J. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS AND DEMISING WALLS) SHALL SIDE. WALLS TO EXTEND TO 10'-0" AND BRACE TO STRUCTURAL BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARTION FOR NEW FINISHES. DECK ABOVE. PROVIDE 2 .1/2" SOUND INSULATION IN HORIZONTAL K. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR SURFACE ABOVE CIELING AND INSIDE WALL. INSULATION TO EXTEND 0 af FINISHES AS SCHEDULED. 2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF WALL. L. BUILDING OWNER AND/OR G.C. TO PROVIDE MINISBUNDS AT ALL PERIMETER O o C-� WINDOWS. EXISTING MINIBLINDS TO BE CLEANED AT COMPLETION OF CONSTRUCTION. DENOTES AREA NOT IN CONTRACT M. ALL NEW AND EXISTING FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING HARDWARE IL CO) TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE � Z EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER D DENOTES NEW MILLWORK N LOCATIONS ARE NEEDED A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW om N OF AESTHETIC PURPOSES ONLY. 0 OO N. EXISTING DOORS AND DOOR FRAMES TO BE REUSED DURING CONSTRUCTION o NEW DOOR AND FRAME, REFER TO DOOR SCHEDULE U DOORS THAT ARE QUESTIONABLE FOR REUSE, PLEASE CALL FOR DESIGNERS hhft111NN��o 41, Drawing Number: REVIEW AND APPROVAL OF REUSE BEFORE INSTALLATION. Of Sheets 0. ALL NEW WORKSURFACES TO RECIVE 2-1/2" GROMMETS. NEW GROMMET LOCATIONS 24376 9 TO BE VERIFIED WITH TENANT IN FIELD AND WITH RESPECT TO NEW ELECTRICAL LAYOUT CONSTRUCTION PLAN NOTES: FP1 ALIGN FINISHED FACES. Io FP2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS U m USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT Iw BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 1/A201. FP3 NEW OR RELOCATED RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. �o FP4 PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE MAKER AND COFFEEMAKER. VERIFY EXACT LOCATION OF ALL APPLIANCES, REQUIRING A WATER SOURCE WITH TENANT. w FP5 CENTER WALL ON CENTER LINE OF COLUMN, FPs COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MFG. MANUAL. ICEMAKER TO BE PROVIDED AND INSTALLED BY TENANT 0 0UNDERCOUNTER G.C. TO PROVIDE POWER SOURCE AND DRAIN FOR ICEMAKER. VERIFY EXACT LOCATION WITH TENANT. Fp8 UNDERCOUNTER REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER N �s PROVIDE 30" x 4' x 8' FIRE RETARDANT PLYWOOD PHONE BOARD. PHONE BD. PAINTED WTH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH 1/4" CLEAR TEMPERED GLASS 5/8" GYPSUM WALL BOARD ALUMINUM GLASS RECIEVER TRACK 3 5/8" X 25 GAUGE METAL STUDS 0 24" O.C. 5/8" GYPSUM WALL BOARD GYPSUM WALL BOARD 48n 3 SILL DETAIL SCALE: 1 1/2'$ = 1'-0" 2" SEE 9" -I'l w VHRILJ _ 12 kk' —O .)k nrUULt FRAME 280 East 96th Street, Suite 200 I FAX 317.574.0957 ®Copyright 2001 CD O -- LEVER C:> I w ] U O = �z T M� 00 0 af U 3 LEVER o o O o C-� w Z LEVER HARDWARE IL CO) I 1 � Z � HARDWARE N Ckf z om N 0 OO (� �m I1o a2o1 10W U o i hhft111NN��o 41, Drawing Number: A201 Of Sheets Duke Job Number: I 24376 9 °O Io U m Iw �o w N it W 1'-6" w 3'-0" WELDED FRAME // w Architecture _ 1/4" TEMPERED SIDELIGHMPERED Z FRAME 280 East 96th Street, Suite 200 �z FAX 317.574.0957 ®Copyright 2001 CD O -- LEVER C:> I w ] U O = �z T M� 00 0 af U 3 LEVER o o O o C-� w Z LEVER HARDWARE IL CO) LEVER HARDWARE Z 0 HARDWARE OQ U CO) Ckf z om Q v 0 OO �s 10W U hhft111NN��o 41, Drawing Number: D3 WELDED FRAME CSO Architecture _ 1/4" TEMPERED = SIDELIGHT FRAME 280 East 96th Street, Suite 200 �z FAX 317.574.0957 ®Copyright 2001 CD O -- LEVER w HARDWARE °O O = �z T M� O O MM N w U 3 �w V) O o CD w IlllWA% D4 WELDED CSO Architecture RATED TIMELY FRAME = Land Surveying FRAME 280 East 96th Street, Suite 200 w FAX 317.574.0957 ®Copyright 2001 0 Q) ob O = 90 MIN. RATED T M� z MM N w DOOR 3 o V) M CD w 'o Z LEVER ZD IL CO) LEVER HARDWARE Z a0 LLJJ� HARDWARE OQ U CO) Ckf z 0 Q v 0 OO �s 10W U hhft111NN��o 41, Drawing Number: A201 Of Sheets Duke Job Number: A/E Job Number: 24376 o� U m D5 Ue REALr cORPORATtoN 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone:(317) 808-6000 Fax: (317) 808-6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying GorRorste Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 0 Q) ob O T M� MM N w r 3 U V) M U Z � a Z J IL CO) z LU 0 U-) o Z Z ONO 0 Z a0 LLJJ� W OQ U CO) _ J Z 0 Q v Certif' �s 10W STATE hhft111NN��o 41, Drawing Number: A201 Of Sheets Duke Job Number: A/E Job Number: 24376 n IN GENERAL CEILING NOTES: ACOUSTICAL CEILING A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWI;;E NOTED. FIXTURE TO BE REMOVED B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO irm ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES 280 East 96th Street, Suite 200 IN CLOSE PROXIMITY ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION. .1� C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY BUILDING STANDARD DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH :K NEW DOWNLIGHT FIXTURE, CONSTRUCTION. �l7:11• • �114�' TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND I JV■ NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, TO MATCH BUILDING STANDARD. ill „ COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE MACORE VENEER BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER EXISTING 4X4 CEILING SUSPENSION SYSTEM. TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR MACORE VENEER TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS z FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. Ei BREAK COPY E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL CEILING SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT 2 DETAIL OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS ETC.} AND VERIFY NEW 2 X 2 INTERMEDIATE CEILING T'S AND PADS. CONFORMANCE WITH LOCAL AND STATE CODES. LIFE�AFEIY CONTRACTOR Y� IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC GYPSUM BOARD CEILING REVIEW ONLY. ,�_ F. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING. GENERAL CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION. p NEW PENDANT FIXTURE. FIXTURE TO BE XXXX G. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. NL INDICATES NIGHT LIGHT LOCATION. CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT N Q CONDITION AS TO NOT SHOW LINE OF DEMOLITION. Z H. RE -USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT 0 FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED , FIXTURES TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED, a RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION. a I. CEILING HEIGHT IS 9'-0" A.F.F. UNLESS OTHERWISE NOTED. _j CEILING PLAN NOTES: TENANT SUPPLIED AND INSTALLED CEILING MOUNTED PROJECTOR LOCATION. 0 CP1 VERIFY EXACT LOCATION WITH TENANT. ;fR. • • ``� CP2 RATED LID. HEIGHT TO MATCH ,� • EXIOSTING GRHD IN CORR DOR.ALL ACOUSTICAL CEILING 2'-6- +10'-6" 2'-4Y" � I W ICATED CIRCUIT OUTLET. NE DED a = .: 7■7 W .:...... 040 V m W C J B INSTALLED IN CONDUIT. E B. ALL CONDUCTORS SHALL ST r ■ ,. ,. , , { > ..:..::..+ ..:: .:..:.. .....:.._ m ti - • N0: AR0091 STATE OF j 1 . �iintttaa� Drawing Number: A202 Of Sheets Duke Job Number: A/E Job Number: CEILING MOUNTED OUTLET. NEW TELEPHONE COMB. CABLE, ADMINISTRATIVE NETWORK DROP. C. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL STAIR MmEEN ... `-,. - ; ; ,'` 2- ■ NEW JUNCTION BOX FOR SYSTEMS FURNITURE. VERIFY EXACT REQUIREMENTS TO BE COMPATIABLE WITH TENANT EQUIPMENT. -. EUVA , . - , � - _- ..: , ... _. ., _ -. _ -.- _ � � ,. REQUIREMENTS WITH FURNITURE VENDOR. POFURNI LOCATION AND POWERD. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO 1 - ■ s LOCATIONS AND CIRCUITING REQUIREMENTS COORDINATE ELECTRICAL LO ON WITH TENANT AND/OR 1 ■ "= N D FAULT INTERUPT CIRCUIT OUTLET NEW GROUND TMS BASE FEED AND OR POWER FURNITURE DEALERSHIP FOR SYSTEMS POLES. 10 m 9M0 9M0 9M 0 � ■ a ������ �� �� � ����� ���� � GFI �iErmornoRUNES � ■7 +44 INDICATES HEIGHT A.F.F. E. ALL RECEPTACLES THAT ARE SHOWN DASHED ARE TO BE REMOVED FROM EXISTING WALLS IT , .- _, : ; .. ,. � . , ; f , J J O , / , , ; :,,.. : PP POWER POLES SUPPLIED BY TENANT. AND SHALL BE PATCHED AND REPAIRED WITH DRYWALL PRIOR TO NEW WALL FINISH : ■ ■ FILE MP SET CO UP F. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18 A.F.F. r ,, mammon ■ 0 UNLESS OTHERWISE NOTED. t 110 109 T I, ELECTRICAL�, PLAN NOTES: , : :E1 777,177 ,- ..PROVIDE DEDICATED POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY REQUIREMENTS WITH TENANT EQUIPMENT. E2 PROVIDE POWER FOR TENANT SUPPLIED CEILING MOUNTED PROJECTOR. ELECTRICAL PLAN VERIFY POWER REQUIREMENTS WITH MANUFACTURER. ALTERNATES: MENEEMENEEN SCALE: 1 /8"-1'-0" 1. PROVIDE POWER PANELS IN FILE/EQUIPMENT ROOM 110. SPACE TO BE SUBMETERED. NORTH VERIFY EXACT LOCATION WITH TENANT AND PROPERTY MANAGER. 9a, 7,E 070 i0 . Ell, I M 7 7 7 1- .ErnErmormormormo I- mHEEMENUENE 1ffW4",- 0,9F.N9 MAN W 0 km rm 0 rm 0 rm 0 rm 0 rN 0 FAIN logo" mom U! all 111HErmormillrnmem INHERE logo INEENE MEN AM OFFI OFFICE io,,,OFFI CE F1 03 1 NMI AL AL REFLECTED CEILING LEGEND: GENERAL CEILING NOTES: ACOUSTICAL CEILING A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWI;;E NOTED. FIXTURE TO BE REMOVED B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO EXISTING 2' X 4' FLUORESCENT ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES 280 East 96th Street, Suite 200 IN CLOSE PROXIMITY ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION. NEW 2' X 4' FLUORESCENT FIXTURE, TO MATCH C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY BUILDING STANDARD DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH :K NEW DOWNLIGHT FIXTURE, CONSTRUCTION. D. MECHANICAL AND ELECTRICAL IS DESIGN -BUILD. DESIGN -BUILD CONTRACTOR 102 TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND 13 NEW CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, TO MATCH BUILDING STANDARD. EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN -BUILD CONTRACTOR TO „ COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE MACORE VENEER BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER EXISTING 4X4 CEILING SUSPENSION SYSTEM. TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR MACORE VENEER TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS z FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. Ei BREAK COPY E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL CEILING SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT 2 DETAIL OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS ETC.} AND VERIFY NEW 2 X 2 INTERMEDIATE CEILING T'S AND PADS. CONFORMANCE WITH LOCAL AND STATE CODES. LIFE�AFEIY CONTRACTOR Y� IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC GYPSUM BOARD CEILING REVIEW ONLY. ,�_ F. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING. GENERAL CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION. p NEW PENDANT FIXTURE. FIXTURE TO BE XXXX G. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. NL INDICATES NIGHT LIGHT LOCATION. CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT N Q CONDITION AS TO NOT SHOW LINE OF DEMOLITION. Z H. RE -USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT 0 FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED , FIXTURES TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED, a RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION. a I. CEILING HEIGHT IS 9'-0" A.F.F. UNLESS OTHERWISE NOTED. _j CEILING PLAN NOTES: TENANT SUPPLIED AND INSTALLED CEILING MOUNTED PROJECTOR LOCATION. 0 CP1 VERIFY EXACT LOCATION WITH TENANT. ;fR. • • ``� CP2 RATED LID. HEIGHT TO MATCH ,� • EXIOSTING GRHD IN CORR DOR.ALL ACOUSTICAL CEILING 2'-6- +10'-6" 2'-4Y" WALL CEILI SCALE: 1 "=1'-0" 9/8" GYPSUM WALL BOARD DRYWALL CEILING +10'-0" 0 0 SCALE: 1 "=1'-O" 5/8" DRYWALL ---/ M /4- I'LYWUUU W/ MACORE VENEER PANELS A 5/8" PLYWOOD IL WOOD WRAPPED 21 /2" METAL STUDS K73T�\ COLUMN SECTION SCALE: 3/4"=1'-0" --- 3/4" PLYWOOD W/ MACORE VENEER PANELS 5/8" PLYWOOD 5/8" METAL STUDS WOOD WRAPPED COLUMN DETAIL SCALE: 3"=1'-0" ' ACOUSTICAL CEILING Engineering RECEPTION :r +9'-0" OL DRYWALL CEILING Corporate Office 280 East 96th Street, Suite 200 +8'-6" } ai 0 Q) GENERAL ELECTRICAL NOTES: C PLYWOOD 102 COFFEE / M PLYWOOD ' 3/4" PLYWOOD W/ „ MACORE VENEER 3/4" PLYWOOD W/ v MACORE VENEER z Ei BREAK COPY a CEILING BULKHEAD 2 DETAIL SCALE: 1 "=1'-O" 5/8" DRYWALL ---/ M /4- I'LYWUUU W/ MACORE VENEER PANELS A 5/8" PLYWOOD IL WOOD WRAPPED 21 /2" METAL STUDS K73T�\ COLUMN SECTION SCALE: 3/4"=1'-0" --- 3/4" PLYWOOD W/ MACORE VENEER PANELS 5/8" PLYWOOD 5/8" METAL STUDS WOOD WRAPPED COLUMN DETAIL SCALE: 3"=1'-0" -- ukeREALTY 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone:(317) 808-6000 Fax: (317) 808-6797 CSO Architecture Engineering RECEPTION :r Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 1 2001 ai 0 Q) GENERAL ELECTRICAL NOTES: C 102 COFFEE / M m ' o� r „ cn o o v z Ei BREAK COPY a J CL Y� A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT a 112 111 0 ,�_ o� J ~ NEW DUPLEX WALL OUTLET. AT PHONE AND DATA LOCATIO S AS INDICATED ON PLANS. COMPLETE PHONE AND DATA � BY THE TENANT UNLESS z Q .. 1< -... N Q W Z � 0 Z , z a � a SYSTEMS (MATERIAL & LABOR PROVIDED OTHERWISE INDICATED _j Z 0 z U s_ J J � I W ICATED CIRCUIT OUTLET. NE DED a = .: W .:...... :..:..::.. V W C J B INSTALLED IN CONDUIT. E B. ALL CONDUCTORS SHALL ST r ■ ,. ,. , , { > ..:..::..+ ..:: .:..:.. .....:.._ m ti - • N0: AR0091 STATE OF j 1 . �iintttaa� Drawing Number: A202 Of Sheets Duke Job Number: A/E Job Number: CEILING MOUNTED OUTLET. NEW TELEPHONE COMB. CABLE, ADMINISTRATIVE NETWORK DROP. C. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL STAIR ... `-,. - ; ; ,'` 2- ■ NEW JUNCTION BOX FOR SYSTEMS FURNITURE. VERIFY EXACT REQUIREMENTS TO BE COMPATIABLE WITH TENANT EQUIPMENT. -. , . - , � - _- ..: , ... _. ., _ -. _ -.- _ � � ,. REQUIREMENTS WITH FURNITURE VENDOR. POFURNI LOCATION AND POWERD. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO 1 - ■ s LOCATIONS AND CIRCUITING REQUIREMENTS COORDINATE ELECTRICAL LO ON WITH TENANT AND/OR 1 ■ "= N D FAULT INTERUPT CIRCUIT OUTLET NEW GROUND TMS BASE FEED AND OR POWER FURNITURE DEALERSHIP FOR SYSTEMS POLES. ■ ������ �� �� � ����� ���� GFI I FURNITURE SYSTEM TO BUIL ELECTRICAL CONTRATOR TO HARDWIRE DING POWER SOURCE +44 INDICATES HEIGHT A.F.F. E. ALL RECEPTACLES THAT ARE SHOWN DASHED ARE TO BE REMOVED FROM EXISTING WALLS IT , .- _, : ; .. ,. � . , ; f , J J O , / , , ; :,,.. : PP POWER POLES SUPPLIED BY TENANT. AND SHALL BE PATCHED AND REPAIRED WITH DRYWALL PRIOR TO NEW WALL FINISH : ■ ■ FILE MP SET CO UP F. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18 A.F.F. r ,, ■ EU � P UNLESS OTHERWISE NOTED. t 110 109 T I, ELECTRICAL�, PLAN NOTES: , : :E1 777,177 ,- ..PROVIDE DEDICATED POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY REQUIREMENTS WITH TENANT EQUIPMENT. E2 PROVIDE POWER FOR TENANT SUPPLIED CEILING MOUNTED PROJECTOR. ELECTRICAL PLAN VERIFY POWER REQUIREMENTS WITH MANUFACTURER. ALTERNATES: SCALE: 1 /8"-1'-0" 1. PROVIDE POWER PANELS IN FILE/EQUIPMENT ROOM 110. SPACE TO BE SUBMETERED. NORTH VERIFY EXACT LOCATION WITH TENANT AND PROPERTY MANAGER. -- ukeREALTY 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone:(317) 808-6000 Fax: (317) 808-6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 1 2001 ai 0 Q) O C Win �eM r M m ' o� or o cn o o v z a J CL J a > o� ~ 0 z Q Ujv J W N Q W Z 0 04 0 Z cc T- z z a � a _j Z 0 z U s_ J J � W V a = o W V W J U. W C e rt i ' Tu�ii���� • F • m ti - • N0: AR0091 STATE OF j 1 . �iintttaa� Drawing Number: A202 Of Sheets Duke Job Number: A/E Job Number: 24376 FILLER PANEL. —� CUSTOM PLASTIC LAMINATE UPPER CABINETS. ADJ. SHELVES AN 4" WIRE PULLS. PLASTIC LAMINATE COUNTER 36" A.F.F. WITH 1 1/2" EDGE & 4" BACKSPLASH. PL1 CUSTOM PLASTIC LAMINATE BASE CABINETS. W/ (2) ADJ. SHELVES AND 4" WIREF PULLS. PL2 FILLER PANEL. E 23 3'-0" V-3" 2'-0" I �D I Engineering `° N OPEN OP N OPEN y � I x OPEN OPEN OPEN WD1 7 I WD1 V) .5 0 0 I n LO LO 5'-7%" 2'-6" 5'-4y" 2'-6" 0 I 2'-6" 29'-93/8" L� in U 2'-6" 4'-6J/2" 2'-6" EQ 2'-6" EQ 2'-6" 4'-6Y2" � 32'-2V4" a 0 Z Uj X Q CO) Loa W Z Q O ND I I L-7 I Z � --Z Z a a LA Ll—�A— �W � z Z O Q PLASTIC LAMINATE COUNTER 0 3/4" x 25 34" A.F.F. WITH 1 1/2" EDGE W/1/2" LI & 3 1/2" APRON, SS DOUBLE BOWL SINK. a a W = J W Certif' "SNO, ruC��s� m low TENANT PROVIDED Drawing Number: A601 Of Sheets Duke Job Number: A/E Job Number: 24376 3 CEMAKER A601 &REFRIGERATOR. L-- 2'-9" 1, 2'-9" L 3'-0" L. S-5" t BREAK ROOM 112 MILLWORK ELEVATION SCALE: 1/2"=l' -On BREAK ROOM 112 WALL ELEVATION SCALE: 1/4"=l' -O" I �D I Engineering `° N OPEN OP N OPEN y � I x OPEN OPEN OPEN WD1 7 I WD1 V) .5 0 0 I n LO LO 5'-7%" 2'-6" 5'-4y" 2'-6" 0 I 2'-6" 29'-93/8" L� in U 2'-6" 4'-6J/2" 2'-6" EQ 2'-6" EQ 2'-6" 4'-6Y2" � 32'-2V4" BREAK ROOM 112 WALL ELEVATION SCALE: 1/4"=l' -O" 6 A601 COMP. SET UP 109 WALL ELEVATION SCALE: 1/4"= 1'-0" FILLER PANEL. PLASTIC LAMIfTE (PI -1) COUNTER AND 4" BACKISPLASH. 5/8" GYPSUM BOARD. 3/4" PLYWOOD TO BE BUTT JOINTED. WOOD TO MATCH WD1. 3/4" PLYWOOD TO BE BUTT JOINTED. WOOD TO MATCH WD1. 1, h3/4" PLYWOOD TO BE BUTT JOINTED. WOOD TO MATCH WD1. 5/8" GYPSUM BOARD. OPEN OFFICE 113 9 WALL DETAIL �01 SCALE: 1" = 1'-0" TENANT PROVIDED COPIER. COPY ROOM 111 CABINET ELEVATION SCALE: 1/2"=V-0" 4'-0" N CUSTOM PLASTIC LAMINATE -UPE�— — — —R CABINETS W/ (2)ADJ. \ \ i SHELVES AND 4" WIRE PULLS PL2 PLASTIC LAMINATE COUNTER N 36" A.F.F. WITH1 1/2" EDGE PL1 & 4" BACKSPLASH. OM PLASTIC LAMINATE BASE CABINETS W/ (2) ADJ. SHELVES AND 4" WIRE PULLS. p� L 4' -0 - I Architecture Engineering `° N OPEN OP N OPEN y � I Corporate Office 280 East 96th Street, Suite 200 n FAX 317.574.0957 ®Copyright 2001 WD1 V) .5 0 0 I LO LO 5'-7%" 2'-6" 5'-4y" 2'-6" 5'-2y" 2'-6" 6'-1 4" 2'-6" 29'-93/8" L� 6 A601 COMP. SET UP 109 WALL ELEVATION SCALE: 1/4"= 1'-0" FILLER PANEL. PLASTIC LAMIfTE (PI -1) COUNTER AND 4" BACKISPLASH. 5/8" GYPSUM BOARD. 3/4" PLYWOOD TO BE BUTT JOINTED. WOOD TO MATCH WD1. 3/4" PLYWOOD TO BE BUTT JOINTED. WOOD TO MATCH WD1. 1, h3/4" PLYWOOD TO BE BUTT JOINTED. WOOD TO MATCH WD1. 5/8" GYPSUM BOARD. OPEN OFFICE 113 9 WALL DETAIL �01 SCALE: 1" = 1'-0" TENANT PROVIDED COPIER. COPY ROOM 111 CABINET ELEVATION SCALE: 1/2"=V-0" 4'-0" N CUSTOM PLASTIC LAMINATE -UPE�— — — —R CABINETS W/ (2)ADJ. \ \ i SHELVES AND 4" WIRE PULLS PL2 PLASTIC LAMINATE COUNTER N 36" A.F.F. WITH1 1/2" EDGE PL1 & 4" BACKSPLASH. OM PLASTIC LAMINATE BASE CABINETS W/ (2) ADJ. SHELVES AND 4" WIRE PULLS. p� L 4' -0 - r5"'*� A601 OPEN OFFICE 113 WALL ELEVATION SCALE: 1/4"=11-0" 8 A601 A601 % SCALE: 1/2"=1'-0" do BLACK PAINTED REVEAL 2" BLACK PAINTED REVEAL " CERAMIC BASE 3'-0" 00o I 0 �I O O A NOTE: SINK PIPES BELOW ARE TO BE WRAPPED FOR COMPLIANCE WITH ADA GUIDELINES. BLOCKING AS REQUIRED SINK AND HARDWARE ABOVE RETRACTABLE HAEFLEE HARDWARE INDICATES DOOR IN RETRACTED POSITION ADJACENT CABINET RECESSED BASE LINE BELOW ARROW INDICATES DIRECTION OF MOVEMENT BY RECTACTABLE CABINET ASTRAGAL ON CABINET DOOR TOUCH LATCH HARDWARE ON CABINET FRONTS ADA SINK 3 BASE SECTION �11 SCALE: 1"=1'-0" LOBBY WOOD 8 WALL SECTION A601 SCALE: 1" = 1'-0" EVEAL ue IFREALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 ax: 317 808-6797 ■ to I Architecture Engineering WD1 `D OPEN OPEN OPEN Corporate Office 280 East 96th Street, Suite 200 N FAX 317.574.0957 ®Copyright 2001 WD1 V) .5 0 0 I LO CM a Q 4'-6Y" 2'-6" EQ 2'-6" EQ 2'-6" 4'-6Y" 2'-6" 32'-3Y" r5"'*� A601 OPEN OFFICE 113 WALL ELEVATION SCALE: 1/4"=11-0" 8 A601 A601 % SCALE: 1/2"=1'-0" do BLACK PAINTED REVEAL 2" BLACK PAINTED REVEAL " CERAMIC BASE 3'-0" 00o I 0 �I O O A NOTE: SINK PIPES BELOW ARE TO BE WRAPPED FOR COMPLIANCE WITH ADA GUIDELINES. BLOCKING AS REQUIRED SINK AND HARDWARE ABOVE RETRACTABLE HAEFLEE HARDWARE INDICATES DOOR IN RETRACTED POSITION ADJACENT CABINET RECESSED BASE LINE BELOW ARROW INDICATES DIRECTION OF MOVEMENT BY RECTACTABLE CABINET ASTRAGAL ON CABINET DOOR TOUCH LATCH HARDWARE ON CABINET FRONTS ADA SINK 3 BASE SECTION �11 SCALE: 1"=1'-0" LOBBY WOOD 8 WALL SECTION A601 SCALE: 1" = 1'-0" EVEAL ue IFREALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 ax: 317 808-6797 ■ CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 0 V) .5 0 CM a Q o L� C U � J a 0 Z Uj X Q CO) Loa W Z Q O ND 0 Z � --Z Z a a V W .. �W � Z v):2 O Z O Q U �■ a a W = J W Certif' "SNO, ruC��s� m low STATE OF r AA Drawing Number: A601 Of Sheets Duke Job Number: A/E Job Number: 24376 -------------- -1-71 CONF RM OFFICE OFFICE OFFICE CONF. RM F1-0-4-1 F1051106 107 c1 103 C1 C1 OC, C1 B1 P1 �¶ F-\ B1 P1 1 (I� 00 00 II II 8O 1 B1 PB1 P1 B1 P1 OPEN OFFICE 113 c1 B1 P1 CONFERENCE (LjD 1 108 (Be NORTH ENLARGED r_i"� FLOOR PLAN A801 SCALE: 1/2" = 1'-0" FINISH LEGEND: FLOORCOVERINGS62 4" CERAMIC TILE BASE MFG: CROSSVILLE c1 CARPET - DIRECT GLUE SERIES: AMERICANA MFG: J & J INDUSTRIES COLOR: AV114 GRAND CANYON PATTERN: 2815 FILM FEST SIZE: 4"X12" BULLNOSE COLOR: 1104 SOME LIKE IT HOT WALLCOVERING c2 CARPET - DIRECT GLUE W1 MFG: VERSA D.L. COUCH MFG: ATLAS PATTERN: CARIBE PATTERN: KAGO COLOR: A-47 HAITIAN COLOR: 33 TAN STONE aill MEN —� ONE F_ CERAMIC TILE Land Surveying PATTERN: TBD 131 r%ION\ 0 COLOR: TBD o' SERIES: AMERICANA RECEPTION A801 COLOR: AV114 GRAND CANYON N TD m m - ----- --10_1 SIZE: 12X12 r-- 3 o v PLASTIC LAMINATE o MFG: ICI v CO) P1 COLOR: 719 PILLAR S VINYL COMPOSITION TILE OPEN OFFICE 113 c1 B1 P1 CONFERENCE (LjD 1 108 (Be NORTH ENLARGED r_i"� FLOOR PLAN A801 SCALE: 1/2" = 1'-0" FINISH LEGEND: FLOORCOVERINGS62 4" CERAMIC TILE BASE MFG: CROSSVILLE c1 CARPET - DIRECT GLUE SERIES: AMERICANA MFG: J & J INDUSTRIES COLOR: AV114 GRAND CANYON PATTERN: 2815 FILM FEST SIZE: 4"X12" BULLNOSE COLOR: 1104 SOME LIKE IT HOT WALLCOVERING c2 CARPET - DIRECT GLUE W1 MFG: VERSA D.L. COUCH MFG: ATLAS PATTERN: CARIBE PATTERN: KAGO COLOR: A-47 HAITIAN COLOR: 33 TAN STONE LAMINATE ON 3/4" D W/ BACKSPLASH. LAMINATE f, AS REQUIRED. COMP./SET UP 109 WORKSURFACE SECTION SCALE: 1''= 1'-0" GENERAL FINISH NOTES: A. ALL DOORS TO BE FINISHED TO MATCH EXISTING DOORS. B. ALL DOOR FRAMES TO BE FINISHED TO MATCH BUILDING STANDARD. C. ALL WOOD TRIM TO BE FINISHED TO MA1CH EXISITNG STAIN. D. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPORVAL OF ARCHITECT. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. E. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH TRANSITION FROM FINISH TO FINISH F. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPETS IN PROJECT SCOPE FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING INSTALLATION. G. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND VINYL TILE TRANSITIONS TAKE PLACE. H. VERIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS. IF NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD. I. EXISTING WOOD DOORS AND TRIM THAT ARE TO REMAIN ARE TO BE SANDED AND TOUCHED -UP TO MATCH EXISTING STAIN. J. PAINT NEW OR EXISTING PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT, COLOR TO MATCH ADJACENT WALL FINISH. K. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK, TO ARCHITECT AND/OR DESIGNER FOR REVIEW AND APPROVAL, BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. L. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. M. EXTINGUISHER CABINETS) TO MATCH ADJ(ACENRISUf FACEEATERS, AND FIRE N. ALL DRYWALL BULKHEADS ARE TO BE PAINTED (PX), UNLESS OTHERWISE NOTED ON REFLECTED CEILING PLANS. 0. GROUT COLOR TO BE 100% EPDXY, COLOR TO BE SELECTED BY DESIGNER. P. ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION. FINISH PLAN NOTES: F1 12" CARPET BORDER TO BE CT1 FINISHES TO MATCH EXISTING CORRIDOR FINISHES F2 CSO W2 MFG: TBD cT1 CERAMIC TILE Land Surveying PATTERN: TBD 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 MFG: CROSSVILLE 0 COLOR: TBD o' SERIES: AMERICANA W/ 4" BACKSPLASH. A801 COLOR: AV114 GRAND CANYON N TD m m m� '� SIZE: 12X12 PAINT 3 o v PLASTIC LAMINATE o MFG: ICI v CO) P1 COLOR: 719 PILLAR VCT1 VINYL COMPOSITION TILE Q FINISH: EGGSHELL X z W MFG: ARMSTRONG EQ EQ EQ Q a�EJa PATTERN: STONETEX EXCELON ~ ~ U Q J J - a COLOR: 52149 COCOA BROWN a = MFG: ICI z LL P2 COLOR: 528 GOLDEN NEEDLES vcT2 VINYL COMPOSITION TILE 'STATE OF FINISH: EGGSHELL Drawing Number: MFG: ARMSTRONG Of Sheets Duke Job Number: A/E Job Number: STONETEX EXCELON ❑PATTERN: COLOR: 52128 DESERT DUST MFG: ICI P3 o COLOR: 1550 ARDEN FORGE FINISH: EGGSHELL VCT3 VINYL COMPOSITION TILE MFG: ARMSTRONG PATTERN: STONETEX EXCELON PLASTIC LAMINATE COLOR: 52150 PEAT GRAY PL1 MANUFACTURER: NEVAMAR COLOR: TM -2 -IT OCHRE TEMPERA VCT4 VINYL COMPOSITION TILE FINISH: MATTE MFG: ARMSTRONG PATTERN: STONETEX EXCELON COLOR: 52156 BAMBOO YELLOW F -PL -2-1 MANUFACTURER: NEVAMAR COLOR: SH -2-2T MAIZE SHIBORI FINISH: MATTE BASE S VINYL BASE -4" COVE BASE MANUFACTURER: JOHNSONITE WOOD FINISH COLOR: 80 FAWN WOOD STAIN AND SPECIES wo1 TO MATCH HEAD QUARTERS LOBBY LAMINATE ON 3/4" D W/ BACKSPLASH. LAMINATE f, AS REQUIRED. COMP./SET UP 109 WORKSURFACE SECTION SCALE: 1''= 1'-0" GENERAL FINISH NOTES: A. ALL DOORS TO BE FINISHED TO MATCH EXISTING DOORS. B. ALL DOOR FRAMES TO BE FINISHED TO MATCH BUILDING STANDARD. C. ALL WOOD TRIM TO BE FINISHED TO MA1CH EXISITNG STAIN. D. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPORVAL OF ARCHITECT. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. E. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH TRANSITION FROM FINISH TO FINISH F. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPETS IN PROJECT SCOPE FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING INSTALLATION. G. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND VINYL TILE TRANSITIONS TAKE PLACE. H. VERIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS. IF NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD. I. EXISTING WOOD DOORS AND TRIM THAT ARE TO REMAIN ARE TO BE SANDED AND TOUCHED -UP TO MATCH EXISTING STAIN. J. PAINT NEW OR EXISTING PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT, COLOR TO MATCH ADJACENT WALL FINISH. K. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK, TO ARCHITECT AND/OR DESIGNER FOR REVIEW AND APPROVAL, BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. L. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. M. EXTINGUISHER CABINETS) TO MATCH ADJ(ACENRISUf FACEEATERS, AND FIRE N. ALL DRYWALL BULKHEADS ARE TO BE PAINTED (PX), UNLESS OTHERWISE NOTED ON REFLECTED CEILING PLANS. 0. GROUT COLOR TO BE 100% EPDXY, COLOR TO BE SELECTED BY DESIGNER. P. ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION. FINISH PLAN NOTES: F1 12" CARPET BORDER TO BE CT1 FINISHES TO MATCH EXISTING CORRIDOR FINISHES F2 COMP./SET UP 109 WORKSURFACE ELEVATION SCALE: 1/2"= V-0" NOTE: MAX. OF 4'-0" BETWEEN SUPPORT PANELS. FDUke st 96th Street 00 polis, IN 46240 {317) 808-6000 (317) 808-6797 CSO i OPEN OPEN � OPEN Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 325" 0 DEEP WORKSURFACE o' R Oll W/ 4" BACKSPLASH. A801 PO -71 N TD m m m� '� v CO a r \ o r 3 o v PLASTIC LAMINATE o o v CO) SUPPORT, AS REQUIRED. — 0 Q PO -71 X z W EQ EQ EQ EQ Q COMP./SET UP 109 WORKSURFACE ELEVATION SCALE: 1/2"= V-0" NOTE: MAX. OF 4'-0" BETWEEN SUPPORT PANELS. FDUke st 96th Street 00 polis, IN 46240 {317) 808-6000 (317) 808-6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 0 Ln Q) o' R Oll N TD m m m� '� v CO a r \ o r 3 o v cn o o v CO) z — 0 Q Z > X z W CoJ W to o W Z 0 NZ Z - Q a�EJa zW D H- 0 W Z ~ ~ U Q J J - a a = = CO) z LL Certif' r AM10036 ) 'STATE OF Drawing Number: A801 Of Sheets Duke Job Number: A/E Job Number: 24376 i 280 280 1 330 CFM CFM CFM E. ,.r ,rtsp� tq' Ob 1 n i .._, R CONE. CNF. R:, . __ I _ R d—. ��._Y � _ �QNF RSI 101 K 103 104 # c 1210 \r 12T � -=� �Y � �t 3T y 1 IW0B 8"0.: , I r I 220 220 I yt,GFM CF 1iQ a i q c ` � p s ` I'i� ♦ rip § ?� ''\3 \ i A 4: 1 1 .5T — +- ' � 3T r -- 00 L 110 8"0 L CFM 220 1 220 b ._ CFM �RECEPTION'v i s �I i 102. �I ycI r WA FAffA , ra 0, MA FzrzzAPff' ........... M 310 CFM JLWS-ly6 11-1y4A 300 300 1 300 CFM CFM I CFM 150 CFM 1 t z } 1 , /0 If8"o d I "� „ 11"WO 150r — I C 8„0 250 CFM OFFICE F ate' 4. I fl OFFICE OFFICE I IfE-- __ -- _—_ _. —_ --- -- cod — {1;, ._.__—. .___.�•`� _. _ .�'-�__-.__„_.__ _ ;ry” - 1,106 ----- - ---- _ —107 — :3 ,f "• -' ; r � � , , .: I! • i IIA. ; � , , � i °yv , [ / �. �` ,�'_ ; ,_.:: F {� E ...ENCS d it W, /i I v V 1 _ . ,,, 108 ' ', A i � '� , a V' r 1 0 . 1..2...m -.\J _- > - TENANT _ ; ; 14 220 119 L / Q CFM 270 270 �� 1 .0 265CEM 8"0 10„� 10„0 t0b0 F7-/ F _ _ m..R 0 10 m \, , r k.\ 265 , ML10„o a °O f 3T L 1 _ i 8.0 220 _ I f , _•r r �.:. CFM 8"0 COFFEE ;I x�_ 1 f ( :A SBR a � IAll 3T _,, M 4I a i > 5 i I 1 170 ,� /' t L 10 0 z ,i _..__.-CFM „ i f _ r _ _'� - �..a,„ ws� __ � _.� ` �m _CFM _8„� COPY - 8 b� i - i1 10 —265 / j_ CFM 111 I _ 8 d, k14"d I : w t a 3TI\ 395 w w I I V` „� T� I 1T 1 ( I ,y v , 00 4F s 3 _. - F f 3 E ; ,F71 _ a I ,,� • /1 1 365 i; � � .__., �, F \ � � +E � 0 � �.�.,� �,�a��:� �v,�� _ Y `CFM_''E.C.;CFM g 305 pi � \ t% `T / s 11 CFM', _ I o d IF IL 1 ri 4` .0 s a e' {� ' COMP SET UP „ r r s � 10' I E I `.c _ __ EXIT CORRIDOR FIRST FLOOR HVAC PLAN scnce��=r-0^ 250 CFM 300 CFM CFM GENERAL NOTES: 1.A LL DUCT GALVANIZED CONSTRUCTION 2.ALL NEW DUCT,FLEX,DIFFUSERS,GRILLES AND REGISTERS 200 CFM 200 CFM 200 CFM Duke 600 Fast 96th Street Sure 1100 indionc:polis, iN 4.6240 Phone; (317) 808-6000 Fox: a317) 808-679' 1BMGlMS= 141!>ErALC®14?MY1NC. 2749 TOBEY DRIVE * INDIANAPOLIS, IN. 46219 (317)895-3939 * Fax (317)895-3940 (ONSMANTS 7825 E. 89th STREET FG INDIANAPOLIS, INDIANA 46256 MQlnft B h1C (317)849-521' FAX: (317; 576.1;_'24 mmfgenaireers.com O d' 1 0 J t� 00 a �' z v r ' Drowinq Number: SNI -1 Of Sheets Duke -Meeks uv'b, Number: A/E Job Number: 1404-192 / Q J t� a z Q z U Q ♦cf) V / Ln Q 0 CN z 0 0 Cn Ir U LL .J Z U. Drowinq Number: SNI -1 Of Sheets Duke -Meeks uv'b, Number: A/E Job Number: 1404-192