INDEX OF DRAWINGS
• COVER
• A201
CONSTRUCTION PLAN & ELEVATIONS
• A202
REFLECTED CEILING ELECTRICAL PLAN & DETAILS
• 401
ELEVATIONS AND DETAILS
• A801
FINISH PLAN & ELEVATIONS
0 APPROVED AS SUBYM ❑ A"PRCMED AS NOTED FGECU
MOM nur
CONPAW
KEYPLAN
SCALE: NOT TO SCALE
HAMILTON CROSSING VI
SPECIFICATIONS AND GENERAL NOTES
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
1
1.1
1.2
1.3
1.4
1.5
OR
CONTRACT CONDITIONS
THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION,
ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR
CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF
THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE
RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED
AS FOLLOWS:
3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND
FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE
PROCEEDING WITH CONSTRUCTION.
3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE
RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES.
3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY
GOVERNMENTAL FEES, LICENSES AND INSPECTIONS.
3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING
ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND
WORKMANSHIP.
10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY
PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE
CONTRACTOR'S RESPONSIBILITY.
WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES,
RULES AND REGULATIONS.
ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD
QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF
THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION
IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED
PROJECT.
WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE
SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND
WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTIUZE THE
SPECIFIED CAPACITIES OF THE EQUIPMENT.
WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS
ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING
JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL
GOVERN THE WORK.
NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE
SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN
DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT
CLARIFIED BY ADDENDUM, THE BETTER QUAUTY OR GREATER QUANTITY
OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S
INTERPRETATION.
INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS,
GENERAL REQUIREMENTS
WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS
WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR
BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT.
THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS
INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE
AND "FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL
COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING,
AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE
WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR
REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS.
CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING
ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND
WORKMANSHIP.
SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE
FOLLOWING ITEMS:
.1 METAL FABRICATIONS.
.2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS.
.3 DOORS, FRAMES AND HARDWARE.
.4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL
PANEL ).
.5 VCT FLOORING AND BASE ( COLOR SAMPLES ).
.6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ).
.7 PAINT ( 6' X 6' ON ACTUAL SURFACE ).
.8 WALLCOVERINGS ( 9' X 9' DYE LOT CUTTING ).
.9 SIGNAGE ( SAMPLE SIGN ).
.10 LIGHT FIXTURES ( CATALOG CUTS ).
TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES,
TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND POWER
WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR
THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING
CONSTRUCTION RULES PUBUSHED BY THE OWNER OR THE OWNER'S
AGENT.
THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND
OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR
SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS,
TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT
EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE.
THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES
ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT
ADDITIONAL CHARGE TO THE PARTY AFFECTED.
THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS
CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS
TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS.
SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT
PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED,
SUBMIT THE FOLLOWING INFORMATION:
.1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF
PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES.
.2 PROVIDE SAMPLES WHERE APPUCABL.E OR REQUESTED.
.3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING All
CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO
ACCOMMODATE THE SUBSTITUTION.
.4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL
AFFECT THE CONTRACT SUM AND CONTRACT TIME.
STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME
FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING.
THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR
HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE
BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN
REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS.
1.12
2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
2.10
411
5
5.1
6
6.1
6.2
6.3
6.4
6.5
6.6
p •L.
Sub1eCt to 'p r®R .
�ornrda� °^�sr
DFpT of,Sta•a arra ca "�ittl a» RUCT1`
C/TY oj: Ci.lco,l M LOcal e o aegulau
A4 Lj,N;17-Y
J0(!a.9
L v/��
CARMEL,
THESE PNHERE
ERE
CERTIFIED:
S HAVE BEEN ACU-Es,
-P...C: T-.. :E� )
D GTYI
�T
tI
-EDEPT OF ^t,UN�C„,.. ^
CARMEL rIE D- Fr..; 1 -LE . TNEYASUITE 125 INDIANA :-F,wE��+rriD ,`+::1 ;,(---'//N
1lT1✓ f 1f iS:,ui'. 9 F HALL
REGULATIONS OF S 5r=li• &,LO;a,�+,l_ CODES.CITY OF CARMEL/ CLAY TOWNSHI;; IND
PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL
CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION
EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE
PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION
NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND
MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN
THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE
INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL
PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD.
COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE
EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE
BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW
WORK.
WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR
EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT,
OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION
TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND
SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING
ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND
WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED
TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR
ADDITIONAL WORK RELATED TO SUCH ACTIVITIES.
WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED
MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL
BE INCLUDED.
REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE
DRAWINGS.
ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE
ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED
FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND
METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW
FINISHES.
EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL
REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR
NOTED TO BE REPAIRED.
SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS.
REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS
REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK
IN SCOPE OF CONTRACT.
PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING
DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS
ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS
SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT
THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS.
CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES
AT MAIN SOURCE OR MAN BRANCH WITHOUT DISRUPTING UTILITY
SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE -
OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED
CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO
DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS
PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS.
CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A
RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT" SET.
PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT,
SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE
DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN.
METAL FABRICATIONS
PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED
OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS
REQUIRED TO COMPLETE WORK.
WOOD AND PLASTIC
CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION
GRADE' LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE
CONTENT.
PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE
EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA
C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32'.
FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND
PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA
C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH
CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING
JURISDICTION.
FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE' AWI
STANDARDS.
.1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR
TO FABRICATION OF MULTIPLE UNITS.
COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH
NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS).
.1 EDGE TREATMENT. SAME AS LAMINATE CLADDING ON HORIZONTAL
SURFACES.
.2 PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE
ELECTRICAL OR DATA OUTLET LOCATIONS.
CABINETS: COMPLY WITH Al SECTION 400 AND ITS DIVISION 4008 FOR
PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS.
.1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS:
GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28
(0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL
THICKNESS).
.2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28.
.3 CABINET HARDWARE SCHEDULE:
.1 HINGES: FULLY CONCEALED, SELF-CLOSING "1000 SERIES"
BY GRASS OR EQUAL.
.2 PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER,
#4483 OR EQUAL AS MANUFACTURED BY STANLEY.
.3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH
MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS
MANUFACTURED BY STANLEY.
.4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES
WITH POSITIVE STOP AND LOCKOUT POSITION, WITH
HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS
MANUFACTURED BY KNAPE & VOGT.
.5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF
SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION
MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED
SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT
OR EQUAL
6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH
PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS.
6,8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING,
WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED
WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY
OPERATING FOR TEN DAYS.
6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND
STRAIGHT WITH NO DISTORTIONS.
6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM
WIDTH NOT TO EXCEED 1/8 U.O.N.
6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL
OUTLETS.
7 JOINT SEALERS
7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS
AND FIXTURES:
.1 "DOW CORNING 786"; DOW CORNING CORP.
.2 "SCS 1702 SANITARY"; GENERAL ELECTRIC CO.
.3 "863 #345 WHITE"; PECORA CORP.
.4 "PROGLAZE WHITE"; TREMCO CORP.
.5 "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS
7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING
SURFACES:
.1 "CHEM -CALK 600"; BOSTIK CONSTRUCTION PRODUCTS DIV.
.2 AC -20"; PECORA CORP.
.3 "SONOLAC'; SONNEBORN BUILDING PRODUCTS
.4 "TREMCO ACRYLIC LATEX 834% TREMCO, INC.
8 DOORS AND WINDOWS
8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS
NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER.
8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED
OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH.
8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH
AND LOCKSETS.
8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048
REQUIREMENTS FOR HEAT -STRENGTHENED GLASS.
9 FINISHES
9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645.
.1 INSTALL "ELIMINATOR" TYPE HEAD TRACK AT WALLS TERMINATING
AT CEILING. USE PREFORMED OUTSIDE CORNERS.
9.2 GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE 'X' TAPERED
EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND
JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE
WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS.
.1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED
INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH
MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA -
216 RECOMMENDED SPECIFICATION FOR THE APPUCATION AND
FINISHING OF GYPSUM BOARD.
9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM
DAMAGED OR SOILED TILES.
.1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS
IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL
REFLECTED CEILING PLAN SHALL GOVERN.
.2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN
LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS
UNLESS NOTED OTHERWISE.
9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR
CASED OPENING UNLESS NOTED OTHERWISE.
.1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET
MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH
CARPET,
9.6 RESILIENT FLOORING:
.1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS
ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT
OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO
AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER.
.2 BASE: AT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID
BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING
ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS.
9.7 USE AN APPROVED CEMENTITTOUS FILLER TO PATCH CRACKS, SMALL
HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM
SURFACE VARIATION OF %' IN 10 FEET, NON -CUMULATIVE.
9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING
STANDARDS:
FLAMMABILITY: ASTM 2859
SURFACE BURNING: ASTM E84
SMOKE DENSITY: ASTM E662
SOUND ABSORPTION: ASTM C423
FADE RESISTANCE: AATCC 16E
STATIC RESISTANCE: AATCC 134
WARRANTY: 10 YEARS
.1 INSTALL BROADLOOM CARPET BY DIRECT GLUE.
9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR
PROTECT HARDWARE, PLATES AND SIMILAR TRIM, AFTER PAINT IS DRY,
REINSTALL SUCH ITEMS.
.1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT
SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD
FOR THE VARIOUS SUBSTRATES, AS INDICATED.
1. FERROUS METAL:
A. ACRYLIC SEMI -GLOSS ENAMEL FINISH:
1. PRIMER: 1 COAT 141702 METALCLAD ACRYLIC
LATE( PRIMER.
2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC
SEMI -GLOSS ENAMEL.
2. NON-FERROUS METAL:
A. ACRYLIC SEMI -GLOSS ENAMEL FINISH:
1. PRIMER: 1 COAT 141702 METALCLAD ACRYLIC
LATEX PRIMER.
2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC
SEMI -GLOSS FINISH
3. FERROUS STRUCTURE:
A. ACRYLIC DRY FOG FIAT FINISH:
1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER
REDUCIBLE ACRYLIC DRY FOG COATING
4. NON-FERROUS STRUCTURE:
A. ACRYLIC DRY FOG FLAT FINISH:
1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER
REDUCIBLE ACRYLIC DRY FOG COATING.
8. WOOD:
A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH:
1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX
PRIMER -SEALER.
2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC
SEMI -GLOSS ENAMEL
B. STAIN -VARNISH RUBBED FINISH:
1. FILLER: 1 COAT #4800 WONDER WOODSTAIN
PASTE WOOD FILLER
OPEN GRAN WOODS.
2. STAIN: 1 COAT #96XX WONDER WOODSTAIN
ALKYD STAIN.
3. SEALER: 1 COAT 14900 WONDER WOODSEALER
QUICK DRY SEALER.
4. FINISH: 2 COATS #4600 WONDER WOODSTAIN
ALKYD SATIN VARNISH.
10. GYPSUM WALLBOARD:
A. ACRYLIC LATEX SATIN ENAMEL FINISH:
1. PRIMER: 1 COAT #50801 WONDER TONES LATEX
PRIMER -SEALER.
2. FINISH: 2 COATS #35XX WONDER TONE ACRYUC
LATEX SATIN ENAMEL.
13. PRECAST CONCRETE:
A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS)
1. PRIMER: 1 COAT #150? WONDER -SHIELD ACRYUC
LATEX HOUSE PAINT PRIMER.
2. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX
TEXTURE COATING.
9.11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND
WITHOUT WRINKLES, GAPS OR OVERLAPS.
.1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT
ACCEPTABLE.
.2 SEAMS MUST BE AT LEAST 2" FROM INSIDE CORNERS AND 6' FROM
OUTSIDE CORNERS.
10 SPECIALTIES
10.1 ARE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO
BUILDING STANDARD, PROVIDE JL INDUSTRIES "AMBASSADOR" SERIES,
SEMI RECESSED, DUO -PANEL, FIELD PAINTED.
12 FURNISHINGS
12.
1 CASEWORK
CITY OF CARMEL/CLAY T OWN a Enforcement
HIP
Dept. of Community Services -- Building
One Civic Square 1" Floor; Carmel, IN 46032
AUTHENTICATION CERTIFICATIONS AND AGREh M plans
`
PLAN
le'rvice
the authorized oatihose released foronsible construction by the Indiana Depart of Fire & Building
IDENTICALthat s. I also understand that if ias relsuired undedr the Ohdinnlcessreferenc dare not ebelow.a STOPORK O DER will be served, q �hie
Printed Name
uthorized Signature entitled "Building Code" and Section 29.42equired under Chapter 7, Section 10 of the Carmel City Code,nd Section der entitled "Administration". Required byCarmel / CLay Township Zoning Ordinance,Section
1.1 entitled"Violations and Penalties:Permits/Forms/AuthentStickerlI
0
W
ZLO
=0
U
LO
i
Na �
AR00910M } e
STATE
OF f'
ANP .(
11/18/04
CSO #24376
.1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE
FOLLOWING:
.1 IMPERIAL CABINET CO., INC.
.2 MERILLAT INDUSTRIES, INC.
.3 YORKTOWNE CABINETS
15/16
MECHANICAL AND ELECTRICAL
15/16.1
MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND
ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE
RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS
ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC
CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL
BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE,
INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND
ELECTRICAL SYSTEMS.
15/16.2
GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF
DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND
PLUMBING, SIGNED AND STAMPED FOR STATE RUNG PROCESS BY A
CERTIFIED ENGINEER.
15/16.3
IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S
DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS
DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN)
AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL
DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND
OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK.
15/16.4
SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE
OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT
SHALL COORDINATE WITH PATTERN OF UGHTING LAYOUT AND SHALL
COORDINATE WITH OTHER CEILING COMPONENTS.
15/16.5
DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS
SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR
OWNER'S AGENT.
15/16.6
OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED
WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED.
VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED
EQUIPMENT.
15/16.7
SWITCHES SHALL BE GANGED UNDER ONE PLATE, DIMMERS SHALL BE
GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER.
15/16.8
DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND
INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL
COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND
TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE
INSTALLATION SHALL OCCUR.
15/16.9
DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF
OUTLETS, UNLESS OTHERWISE NOTED.
15/16.10
ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD
COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE
IVORY.
15/16.11
WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY
SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL
PROVIDING PROPER ACCESS TO RECEPTACLES.
15/16.12
IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL
FOR SPECIFIC LOCATION.
15/16.13
CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET
LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO
OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN'
CONSTRUCTION.
GN
GENERAL NOTES
GNA
CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND
REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO
PROCEEDING WITH CONSTRUCTION.
GN.2
DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED:
A. TO FINISHED FACE OF GYPSUM BOARD.
B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS,
C. TO TOP OF FINISHED FLOORS.
D. TO BOTTOM OF FINISHED CEILINGS.
GN.3
SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION,
EXISTING CONSTRUCTION AND WALL TYPES.
GN.4
TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED
OTHERWISE.
GN.5
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION
LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS
SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT,
NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING
WITH CONSTRUCTION.
GN.6
CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT
FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT.
DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS
OBSERVATION.
GN.7
FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT
LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT
FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0' NON-
CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED.
GN.8
CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO
CLOSE -IN OF WALLS,
GNA
SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT
PERIMETER WITH ACOUSTICAL OR FIRE RATED SEALANT AS APPLICABLE.
PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE.
PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED
TO STUD FRAMING, AT THESE PARTITIONS, BACK TO BACK ELECTRICAL
JUNCTION BOXES ARE NOT PERMITTED.
GN.10
ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLED BY
TENANT.
CITY OF CARMEL/CLAY T OWN a Enforcement
HIP
Dept. of Community Services -- Building
One Civic Square 1" Floor; Carmel, IN 46032
AUTHENTICATION CERTIFICATIONS AND AGREh M plans
`
PLAN
le'rvice
the authorized oatihose released foronsible construction by the Indiana Depart of Fire & Building
IDENTICALthat s. I also understand that if ias relsuired undedr the Ohdinnlcessreferenc dare not ebelow.a STOPORK O DER will be served, q �hie
Printed Name
uthorized Signature entitled "Building Code" and Section 29.42equired under Chapter 7, Section 10 of the Carmel City Code,nd Section der entitled "Administration". Required byCarmel / CLay Township Zoning Ordinance,Section
1.1 entitled"Violations and Penalties:Permits/Forms/AuthentStickerlI
0
W
ZLO
=0
U
LO
i
Na �
AR00910M } e
STATE
OF f'
ANP .(
11/18/04
CSO #24376
TYPICAL WALL TYPE—
TYPICAL AT ALL EXTERIOR
WALLS- 5/8" TYPE X G.W.B.
FINISH BELOW EXISTING
WINDOW SILL COVER
PREFINISHED ALUMINUM RECEIVER TRIM
"GB350". FASTEN AT WINDOW SILL &
SET IN A CONTINUOUS BEAD OF
ACOUSTICAL SEALANT. TRIM COLOR TO
MATCH BLDG. WINDOW MULLIONS.
LINE OF EXISTING WINDOW SILL
COVER BELOW
METAL
.STUD
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
WINDOW MULLION
DETAIL
A201 SCALE: 1/2"= 1'-0"
1 /2"HW,
1 /2"CW,
&
1-1/4"V
SII
I � i
I
I CONNECT TO
RI III IANC, I iwo,
PLUMBING
2 ISOMETRIC
A201 SCALE: 1/2"= 1'-0"
2"W
TO BUILDING DRAIN
DOOR SCHEDULE
fl.
PILL VYMLLJ OFWALL UL \,"MULRLV VI I I VR ULJIVI9LR J RLVILVV Ur Nr VV WALL LUllJIKU(JIIUN
DOOR
I.
FRAME
.)k nrUULt
HARDWARE
REMARKS
SIZE
FAX 317.574.0957 ®Copyright 2001
CD
— WITH 5/8" GYPSUM WALL BOARD EACH "�
J.
t MY
SIDE. WALLS TO EXTEND TO 10'-0" AND BRACE TO STRUCTURAL
BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARTION FOR NEW FINISHES.
DECK ABOVE. PROVIDE 2 .1/2" SOUND INSULATION IN HORIZONTAL
LLJ
�
FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR
SURFACE ABOVE CIELING AND INSIDE WALL. INSULATION TO EXTEND
0 af
FINISHES AS SCHEDULED.
2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF WALL.
U
F— OO
�i �
BUILDING OWNER AND/OR G.C. TO PROVIDE MINISBUNDS AT ALL PERIMETER
O
o
C-�
WINDOWS. EXISTING MINIBLINDS TO BE CLEANED AT COMPLETION OF CONSTRUCTION.
DENOTES AREA NOT IN CONTRACT
M.
ALL NEW AND EXISTING FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING
HARDWARE
IL
CO)
TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE
Z
Z
z
�o��
N
ZmLai
om
N
OF AESTHETIC PURPOSES ONLY.
0
OO
N.
EXISTING DOORS AND DOOR FRAMES TO BE REUSED DURING CONSTRUCTION
o NEW DOOR AND FRAME, REFER TO DOOR SCHEDULE
>¢
DOORS THAT ARE QUESTIONABLE FOR REUSE, PLEASE CALL FOR DESIGNERS
hhft111NN��o
41,
Drawing Number:
REVIEW AND APPROVAL OF REUSE BEFORE INSTALLATION.
o
w
ALL NEW WORKSURFACES TO RECIVE 2-1/2" GROMMETS. NEW GROMMET LOCATIONS
24376
9
Q
u u n u n u
CONSTRUCTION PLAN NOTES:
O Z
p0
U Q
FP1 ALIGN FINISHED FACES.
_
F-
FP2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS
W
=LV
J
V)___1 m L�
J(nO_UnU)
100A
LOBBY
Iw
EXISTING TO REMAIN
1008
LOBBY
3'-0"
8'-0"
1 3/4"
WOOD
D1
HM
D1
SF,S
101
CONFERENCE
S-0"
8'-0"
1 3/4"
WOOD
D3
HM
D3
L,S
FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MFG. MANUAL.
103
CONFERENCE
3'-0"
8'-O"
1 3/4"
WOOD
D3
HM
D3
PS,S
104
CONFERENCE
S-0"
8'-0"
1 3/4"
WOOD
D3
HM
D3
PS,S
105
OFFICE
S-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
L,S
106
OFFICE
S-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
L,S
107
OFFICE
S-0"
8'-O"
1 3/4"
WOOD
D2
HM
D2
L,S
108
CONFERENCE
3'-0"
8'-0"
1 3/4"
WOOD
D3
HM
D3
PS,S
110
FILE/EQUIP.
3'-0"
8'-0"
1 3/4"
WOOD
D4
HM
D4
SF,S
113
OPEN OFFICE
4'-0"
8'-O"
1 3/4"
WOOD
I D5
HM
D5
L,S,CL,SF
90 MIN. RATED DOOR
DOOR SCHEDULE NOTES
2. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD
WHERE NEEDED.
3. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION.
4. COORDINATE KEYING LOCKSETS WITH TENANT.
w
�z
o O
I >_
co o X
�(n
f):fz
0
O U
Uj
�o
om
A 1 n)1 ,0 n)1
WELDED
FRAME
1/4" TEMPERED
SIDELIGHT
LEVER c
HARDWARE «
D1
DOOR ELEVATIONS
SCALE: 1/411= 1'-0"
n .-
WALL LEGEND: GENERAL CONSTRUCTION NOTES:
NOTES: _ _ = EXISTING CONSTRUCTION TO BE REMOVED A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS
EXISTING PARTITION TO REMAIN NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE
NEW WALL PARTITION TO BE VERIFIED BY DESIGNER- DO NOT SCALE DRAWINGS.
NOTE: ALL NEW WALLS ARE TO BE W1 UNLESS NOTED OTHERWISE. B. PROVIDE WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS.
C. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN
W1 3-5/8" 25 GAUGE METAL STUDS 024"O.C. , ; ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A).
WITH 5/8" GYPSUM WALL BOARD EACH M D. REFER TO CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES.
SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE E. REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH
2 1/2" SOUND INSULATION IN HORIZONTAL SURFACE ABOVE WITH ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE.
CEILING AND INSIDE WALL. INSULATION TO EXTEND 2'-0" IN F. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL.
BOTH DIRECTIONS FROM CENTER LINE OF WALL.
t)I11I 11 `L1 L ') ` '/'L
VII JVIYI I�P\LL UVP11\U 2HR RATED
fl.
PILL VYMLLJ OFWALL UL \,"MULRLV VI I I VR ULJIVI9LR J RLVILVV Ur Nr VV WALL LUllJIKU(JIIUN
EACH SIDE. UL -0419
I.
ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE
.)k nrUULt
FRAME
OF DOOR UNLESS NOTED OTHERWISE TO MEET CURRENT ADA CODE REGULATIONS
W3 3-5/8" 25 GAUGE METAL STUDS 024"O.C.
FAX 317.574.0957 ®Copyright 2001
CD
— WITH 5/8" GYPSUM WALL BOARD EACH "�
J.
ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS AND DEMISING WALLS) SHALL
SIDE. WALLS TO EXTEND TO 10'-0" AND BRACE TO STRUCTURAL
BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARTION FOR NEW FINISHES.
DECK ABOVE. PROVIDE 2 .1/2" SOUND INSULATION IN HORIZONTAL
K.
FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR
SURFACE ABOVE CIELING AND INSIDE WALL. INSULATION TO EXTEND
0 af
FINISHES AS SCHEDULED.
2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF WALL.
L.
BUILDING OWNER AND/OR G.C. TO PROVIDE MINISBUNDS AT ALL PERIMETER
O
o
C-�
WINDOWS. EXISTING MINIBLINDS TO BE CLEANED AT COMPLETION OF CONSTRUCTION.
DENOTES AREA NOT IN CONTRACT
M.
ALL NEW AND EXISTING FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING
HARDWARE
IL
CO)
TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE
�
Z
EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER
D DENOTES NEW MILLWORK
N
LOCATIONS ARE NEEDED A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW
om
N
OF AESTHETIC PURPOSES ONLY.
0
OO
N.
EXISTING DOORS AND DOOR FRAMES TO BE REUSED DURING CONSTRUCTION
o NEW DOOR AND FRAME, REFER TO DOOR SCHEDULE
U
DOORS THAT ARE QUESTIONABLE FOR REUSE, PLEASE CALL FOR DESIGNERS
hhft111NN��o
41,
Drawing Number:
REVIEW AND APPROVAL OF REUSE BEFORE INSTALLATION.
Of Sheets
0.
ALL NEW WORKSURFACES TO RECIVE 2-1/2" GROMMETS. NEW GROMMET LOCATIONS
24376
9
TO BE VERIFIED WITH TENANT IN FIELD AND WITH RESPECT TO NEW ELECTRICAL LAYOUT
CONSTRUCTION PLAN NOTES:
FP1 ALIGN FINISHED FACES.
Io
FP2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS
U m
USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION
FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT
Iw
BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 1/A201.
FP3 NEW OR RELOCATED RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED
IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF.
�o
FP4 PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE
MAKER AND COFFEEMAKER. VERIFY EXACT LOCATION OF ALL
APPLIANCES, REQUIRING A WATER SOURCE WITH TENANT.
w
FP5 CENTER WALL ON CENTER LINE OF COLUMN,
FPs COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE
FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MFG. MANUAL.
ICEMAKER TO BE PROVIDED AND INSTALLED BY TENANT
0 0UNDERCOUNTER
G.C. TO PROVIDE POWER SOURCE AND DRAIN FOR ICEMAKER. VERIFY EXACT LOCATION
WITH TENANT.
Fp8 UNDERCOUNTER REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER
SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER
N
�s PROVIDE 30" x 4' x 8' FIRE RETARDANT PLYWOOD PHONE BOARD. PHONE BD.
PAINTED WTH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH
1/4" CLEAR TEMPERED
GLASS
5/8" GYPSUM WALL BOARD ALUMINUM GLASS
RECIEVER TRACK
3 5/8" X 25 GAUGE METAL
STUDS 0 24" O.C.
5/8" GYPSUM WALL BOARD GYPSUM WALL BOARD
48n
3 SILL DETAIL
SCALE: 1 1/2'$ = 1'-0"
2" SEE 9"
-I'l
w
VHRILJ
_
12
kk' —O
.)k nrUULt
FRAME
280 East 96th Street, Suite 200
I
FAX 317.574.0957 ®Copyright 2001
CD
O
-- LEVER
C:>
I
w
] U
O
=
�z
T M�
00
0 af
U
3
LEVER
o o
O
o
C-�
w
Z
LEVER
HARDWARE
IL
CO)
I
1
�
Z
�
HARDWARE
N
Ckf z
om
N
0
OO
(�
�m
I1o
a2o1
10W
U
o
i
hhft111NN��o
41,
Drawing Number:
A201
Of Sheets
Duke Job Number:
I
24376
9
°O
Io
U m
Iw
�o
w
N
it
W
1'-6" w 3'-0"
WELDED
FRAME
//
w
Architecture
_
1/4" TEMPERED
SIDELIGHMPERED
Z
FRAME
280 East 96th Street, Suite 200
�z
FAX 317.574.0957 ®Copyright 2001
CD
O
-- LEVER
C:>
I
w
] U
O
=
�z
T M�
00
0 af
U
3
LEVER
o o
O
o
C-�
w
Z
LEVER
HARDWARE
IL
CO)
LEVER
HARDWARE
Z
0
HARDWARE
OQ
U CO)
Ckf z
om
Q v
0
OO
�s
10W
U
hhft111NN��o
41,
Drawing Number:
D3
WELDED
FRAME
CSO
Architecture
_
1/4" TEMPERED
=
SIDELIGHT
FRAME
280 East 96th Street, Suite 200
�z
FAX 317.574.0957 ®Copyright 2001
CD
O
-- LEVER
w
HARDWARE °O
O
=
�z
T M�
O O
MM
N w
U
3
�w
V)
O
o
CD
w
IlllWA%
D4
WELDED
CSO
Architecture
RATED TIMELY
FRAME
=
Land Surveying
FRAME
280 East 96th Street, Suite 200
w
FAX 317.574.0957 ®Copyright 2001
0
Q)
ob
O
=
90 MIN. RATED
T M�
z
MM
N w
DOOR
3
o
V)
M
CD
w
'o
Z
LEVER
ZD
IL
CO)
LEVER
HARDWARE
Z
a0 LLJJ�
HARDWARE
OQ
U CO)
Ckf z
0
Q v
0
OO
�s
10W
U
hhft111NN��o
41,
Drawing Number:
A201
Of Sheets
Duke Job Number:
A/E Job Number:
24376
o�
U m
D5
Ue
REALr cORPORATtoN
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone:(317) 808-6000
Fax: (317) 808-6797
CSO
Architecture
Engineering
Interiors
Landscape Architecture
Land Surveying
GorRorste Office
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 ®Copyright 2001
0
Q)
ob
O
T M�
MM
N w
r
3
U
V)
M
U
Z
� a
Z J
IL
CO)
z
LU 0 U-) o Z
Z ONO 0
Z
a0 LLJJ�
W
OQ
U CO)
_ J
Z
0
Q v
Certif'
�s
10W
STATE
hhft111NN��o
41,
Drawing Number:
A201
Of Sheets
Duke Job Number:
A/E Job Number:
24376
n IN
GENERAL CEILING NOTES:
ACOUSTICAL CEILING
A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWI;;E NOTED.
FIXTURE TO BE REMOVED
B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO
irm
ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES
280 East 96th Street, Suite 200
IN CLOSE PROXIMITY ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION.
.1�
C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY
BUILDING STANDARD
DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH
:K NEW DOWNLIGHT FIXTURE,
CONSTRUCTION.
�l7:11•
•
�114�'
TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND
I JV■
NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS,
TO MATCH BUILDING STANDARD.
ill
„
COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE
MACORE VENEER
BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER
EXISTING 4X4 CEILING SUSPENSION SYSTEM.
TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR
MACORE VENEER
TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS
z
FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING.
Ei
BREAK COPY
E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL
CEILING
SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT
2 DETAIL
OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS ETC.} AND VERIFY
NEW 2 X 2 INTERMEDIATE CEILING T'S AND PADS.
CONFORMANCE WITH LOCAL AND STATE CODES. LIFE�AFEIY CONTRACTOR
Y�
IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND
A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT
OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR
SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION
OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC
GYPSUM BOARD CEILING
REVIEW ONLY.
,�_
F. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING.
GENERAL CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION.
p NEW PENDANT FIXTURE.
FIXTURE TO BE XXXX
G. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS,
LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED.
NL INDICATES NIGHT LIGHT LOCATION.
CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT
N Q
CONDITION AS TO NOT SHOW LINE OF DEMOLITION.
Z
H. RE -USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT
0
FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED
,
FIXTURES TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED,
a
RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION.
a
I. CEILING HEIGHT IS 9'-0" A.F.F. UNLESS OTHERWISE NOTED.
_j
CEILING PLAN NOTES:
TENANT SUPPLIED AND INSTALLED CEILING MOUNTED PROJECTOR LOCATION.
0
CP1
VERIFY EXACT LOCATION WITH TENANT.
;fR.
• •
``�
CP2 RATED LID. HEIGHT TO MATCH
,� •
EXIOSTING GRHD IN CORR DOR.ALL
ACOUSTICAL CEILING
2'-6-
+10'-6"
2'-4Y"
�
I
W ICATED CIRCUIT OUTLET.
NE DED
a
=
.:
7■7
W
.:......
040
V
m
W
C
J
B INSTALLED IN CONDUIT.
E
B. ALL CONDUCTORS SHALL ST
r
■
,. ,. , , { >
..:..::..+ ..::
.:..:.. .....:.._
m
ti -
•
N0:
AR0091
STATE OF j 1 .
�iintttaa�
Drawing Number:
A202
Of Sheets
Duke Job Number:
A/E Job Number:
CEILING MOUNTED OUTLET.
NEW TELEPHONE COMB. CABLE, ADMINISTRATIVE NETWORK DROP.
C. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL
STAIR
MmEEN
...
`-,.
- ; ;
,'`
2-
■
NEW JUNCTION BOX FOR SYSTEMS FURNITURE. VERIFY EXACT
REQUIREMENTS TO BE COMPATIABLE WITH TENANT EQUIPMENT.
-.
EUVA
, .
- ,
� -
_- ..: , ... _.
., _ -.
_ -.- _
� � ,.
REQUIREMENTS WITH FURNITURE VENDOR.
POFURNI
LOCATION AND POWERD.
FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO
1
-
■
s
LOCATIONS AND CIRCUITING REQUIREMENTS
COORDINATE ELECTRICAL LO ON WITH TENANT AND/OR
1
■
"=
N D FAULT INTERUPT CIRCUIT OUTLET
NEW GROUND
TMS BASE FEED AND OR POWER
FURNITURE DEALERSHIP FOR SYSTEMS POLES.
10
m
9M0
9M0
9M
0
�
■
a
������ �� �� � ����� ����
�
GFI
�iErmornoRUNES
�
■7
+44
INDICATES HEIGHT A.F.F.
E. ALL RECEPTACLES THAT ARE SHOWN DASHED ARE TO BE REMOVED FROM EXISTING WALLS
IT
, .-
_, : ; .. ,.
� .
, ;
f , J
J
O
, / ,
, ;
:,,.. :
PP
POWER POLES SUPPLIED BY TENANT.
AND SHALL BE PATCHED AND REPAIRED WITH DRYWALL PRIOR TO NEW WALL FINISH
:
■
■
FILE
MP SET
CO UP
F. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18 A.F.F.
r ,,
mammon
■
0
UNLESS OTHERWISE NOTED.
t
110 109
T
I,
ELECTRICAL�, PLAN NOTES:
, :
:E1
777,177 ,-
..PROVIDE
DEDICATED POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY
REQUIREMENTS WITH TENANT EQUIPMENT.
E2 PROVIDE POWER FOR TENANT SUPPLIED CEILING MOUNTED PROJECTOR.
ELECTRICAL
PLAN
VERIFY POWER REQUIREMENTS WITH MANUFACTURER.
ALTERNATES:
MENEEMENEEN
SCALE: 1 /8"-1'-0"
1. PROVIDE POWER PANELS IN FILE/EQUIPMENT ROOM 110. SPACE TO BE SUBMETERED.
NORTH
VERIFY EXACT LOCATION WITH TENANT AND PROPERTY MANAGER.
9a,
7,E
070
i0
.
Ell,
I
M
7
7
7
1-
.ErnErmormormormo
I-
mHEEMENUENE
1ffW4",-
0,9F.N9
MAN
W
0
km rm 0 rm 0
rm 0 rm 0 rN 0
FAIN
logo"
mom
U! all
111HErmormillrnmem
INHERE
logo
INEENE
MEN
AM
OFFI
OFFICE io,,,OFFI CE
F1 03 1
NMI
AL AL
REFLECTED CEILING LEGEND:
GENERAL CEILING NOTES:
ACOUSTICAL CEILING
A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWI;;E NOTED.
FIXTURE TO BE REMOVED
B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO
EXISTING 2' X 4' FLUORESCENT
ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES
280 East 96th Street, Suite 200
IN CLOSE PROXIMITY ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION.
NEW 2' X 4' FLUORESCENT FIXTURE, TO MATCH
C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY
BUILDING STANDARD
DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH
:K NEW DOWNLIGHT FIXTURE,
CONSTRUCTION.
D. MECHANICAL AND ELECTRICAL IS DESIGN -BUILD. DESIGN -BUILD CONTRACTOR
102
TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND
13 NEW CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION
NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS,
TO MATCH BUILDING STANDARD.
EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN -BUILD CONTRACTOR TO
„
COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE
MACORE VENEER
BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER
EXISTING 4X4 CEILING SUSPENSION SYSTEM.
TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR
MACORE VENEER
TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS
z
FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING.
Ei
BREAK COPY
E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL
CEILING
SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT
2 DETAIL
OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS ETC.} AND VERIFY
NEW 2 X 2 INTERMEDIATE CEILING T'S AND PADS.
CONFORMANCE WITH LOCAL AND STATE CODES. LIFE�AFEIY CONTRACTOR
Y�
IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND
A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT
OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR
SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION
OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC
GYPSUM BOARD CEILING
REVIEW ONLY.
,�_
F. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING.
GENERAL CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION.
p NEW PENDANT FIXTURE.
FIXTURE TO BE XXXX
G. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS,
LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED.
NL INDICATES NIGHT LIGHT LOCATION.
CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT
N Q
CONDITION AS TO NOT SHOW LINE OF DEMOLITION.
Z
H. RE -USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT
0
FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED
,
FIXTURES TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED,
a
RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION.
a
I. CEILING HEIGHT IS 9'-0" A.F.F. UNLESS OTHERWISE NOTED.
_j
CEILING PLAN NOTES:
TENANT SUPPLIED AND INSTALLED CEILING MOUNTED PROJECTOR LOCATION.
0
CP1
VERIFY EXACT LOCATION WITH TENANT.
;fR.
• •
``�
CP2 RATED LID. HEIGHT TO MATCH
,� •
EXIOSTING GRHD IN CORR DOR.ALL
ACOUSTICAL CEILING
2'-6-
+10'-6"
2'-4Y"
WALL
CEILI
SCALE: 1 "=1'-0"
9/8" GYPSUM WALL BOARD
DRYWALL CEILING
+10'-0"
0 0
SCALE: 1 "=1'-O"
5/8" DRYWALL ---/
M /4- I'LYWUUU
W/ MACORE VENEER
PANELS
A
5/8" PLYWOOD
IL WOOD WRAPPED 21 /2" METAL STUDS
K73T�\ COLUMN SECTION
SCALE: 3/4"=1'-0"
--- 3/4" PLYWOOD
W/ MACORE VENEER
PANELS
5/8" PLYWOOD
5/8" METAL STUDS
WOOD WRAPPED
COLUMN DETAIL
SCALE: 3"=1'-0"
'
ACOUSTICAL CEILING
Engineering
RECEPTION :r
+9'-0"
OL DRYWALL CEILING
Corporate Office
280 East 96th Street, Suite 200
+8'-6"
}
ai
0
Q)
GENERAL ELECTRICAL NOTES:
C
PLYWOOD
102
COFFEE /
M
PLYWOOD
'
3/4" PLYWOOD W/
„
MACORE VENEER
3/4" PLYWOOD W/
v
MACORE VENEER
z
Ei
BREAK COPY
a
CEILING
BULKHEAD
2 DETAIL
SCALE: 1 "=1'-O"
5/8" DRYWALL ---/
M /4- I'LYWUUU
W/ MACORE VENEER
PANELS
A
5/8" PLYWOOD
IL WOOD WRAPPED 21 /2" METAL STUDS
K73T�\ COLUMN SECTION
SCALE: 3/4"=1'-0"
--- 3/4" PLYWOOD
W/ MACORE VENEER
PANELS
5/8" PLYWOOD
5/8" METAL STUDS
WOOD WRAPPED
COLUMN DETAIL
SCALE: 3"=1'-0"
--
ukeREALTY
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone:(317) 808-6000
Fax: (317) 808-6797
CSO
Architecture
Engineering
RECEPTION :r
Landscape Architecture
Land Surveying
Corporate Office
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 1 2001
ai
0
Q)
GENERAL ELECTRICAL NOTES:
C
102
COFFEE /
M
m '
o�
r
„
cn
o
o
v
z
Ei
BREAK COPY
a
J
CL
Y�
A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT
a
112 111
0
,�_
o�
J
~
NEW DUPLEX WALL OUTLET.
AT PHONE AND DATA LOCATIO S AS INDICATED ON PLANS. COMPLETE PHONE AND DATA
� BY THE TENANT UNLESS
z
Q
.. 1<
-...
N Q
W
Z
�
0
Z
,
z
a
�
a
SYSTEMS (MATERIAL & LABOR PROVIDED OTHERWISE INDICATED
_j
Z
0
z
U
s_
J
J
�
I
W ICATED CIRCUIT OUTLET.
NE DED
a
=
.:
W
.:......
:..:..::..
V
W
C
J
B INSTALLED IN CONDUIT.
E
B. ALL CONDUCTORS SHALL ST
r
■
,. ,. , , { >
..:..::..+ ..::
.:..:.. .....:.._
m
ti -
•
N0:
AR0091
STATE OF j 1 .
�iintttaa�
Drawing Number:
A202
Of Sheets
Duke Job Number:
A/E Job Number:
CEILING MOUNTED OUTLET.
NEW TELEPHONE COMB. CABLE, ADMINISTRATIVE NETWORK DROP.
C. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL
STAIR
...
`-,.
- ; ;
,'`
2-
■
NEW JUNCTION BOX FOR SYSTEMS FURNITURE. VERIFY EXACT
REQUIREMENTS TO BE COMPATIABLE WITH TENANT EQUIPMENT.
-.
, .
- ,
� -
_- ..: , ... _.
., _ -.
_ -.- _
� � ,.
REQUIREMENTS WITH FURNITURE VENDOR.
POFURNI
LOCATION AND POWERD.
FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO
1
-
■
s
LOCATIONS AND CIRCUITING REQUIREMENTS
COORDINATE ELECTRICAL LO ON WITH TENANT AND/OR
1
■
"=
N D FAULT INTERUPT CIRCUIT OUTLET
NEW GROUND
TMS BASE FEED AND OR POWER
FURNITURE DEALERSHIP FOR SYSTEMS POLES.
■
������ �� �� � ����� ����
GFI
I FURNITURE SYSTEM TO BUIL
ELECTRICAL CONTRATOR TO HARDWIRE DING POWER SOURCE
+44
INDICATES HEIGHT A.F.F.
E. ALL RECEPTACLES THAT ARE SHOWN DASHED ARE TO BE REMOVED FROM EXISTING WALLS
IT
, .-
_, : ; .. ,.
� .
, ;
f , J
J
O
, / ,
, ;
:,,.. :
PP
POWER POLES SUPPLIED BY TENANT.
AND SHALL BE PATCHED AND REPAIRED WITH DRYWALL PRIOR TO NEW WALL FINISH
:
■
■
FILE
MP SET
CO UP
F. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18 A.F.F.
r ,,
■
EU
� P
UNLESS OTHERWISE NOTED.
t
110 109
T
I,
ELECTRICAL�, PLAN NOTES:
, :
:E1
777,177 ,-
..PROVIDE
DEDICATED POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY
REQUIREMENTS WITH TENANT EQUIPMENT.
E2 PROVIDE POWER FOR TENANT SUPPLIED CEILING MOUNTED PROJECTOR.
ELECTRICAL
PLAN
VERIFY POWER REQUIREMENTS WITH MANUFACTURER.
ALTERNATES:
SCALE: 1 /8"-1'-0"
1. PROVIDE POWER PANELS IN FILE/EQUIPMENT ROOM 110. SPACE TO BE SUBMETERED.
NORTH
VERIFY EXACT LOCATION WITH TENANT AND PROPERTY MANAGER.
--
ukeREALTY
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone:(317) 808-6000
Fax: (317) 808-6797
CSO
Architecture
Engineering
Interiors
Landscape Architecture
Land Surveying
Corporate Office
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 1 2001
ai
0
Q)
O
C
Win
�eM
r
M
m '
o�
or
o
cn
o
o
v
z
a
J
CL
J
a
>
o�
~
0
z
Q
Ujv
J
W
N Q
W
Z
0 04
0
Z
cc T- z
z
a
�
a
_j
Z
0
z
U
s_
J
J
�
W
V
a
=
o
W
V
W
J
U.
W
C e rt i ' Tu�ii����
•
F •
m
ti -
•
N0:
AR0091
STATE OF j 1 .
�iintttaa�
Drawing Number:
A202
Of Sheets
Duke Job Number:
A/E Job Number:
24376
FILLER PANEL. —�
CUSTOM PLASTIC LAMINATE
UPPER CABINETS.
ADJ. SHELVES AN
4" WIRE PULLS.
PLASTIC LAMINATE COUNTER
36" A.F.F. WITH 1 1/2" EDGE
& 4" BACKSPLASH. PL1
CUSTOM PLASTIC LAMINATE
BASE CABINETS. W/ (2)
ADJ. SHELVES AND 4"
WIREF PULLS. PL2
FILLER PANEL.
E
23
3'-0" V-3" 2'-0"
I
�D
I
Engineering
`°
N
OPEN OP N OPEN
y
�
I
x
OPEN OPEN OPEN
WD1
7
I
WD1
V)
.5
0
0
I
n
LO
LO
5'-7%"
2'-6" 5'-4y"
2'-6"
0
I
2'-6"
29'-93/8"
L�
in
U
2'-6"
4'-6J/2" 2'-6" EQ 2'-6" EQ 2'-6" 4'-6Y2"
�
32'-2V4"
a
0
Z
Uj
X
Q
CO)
Loa
W
Z
Q
O ND
I I L-7 I
Z
� --Z
Z
a
a
LA
Ll—�A—
�W
�
z
Z
O
Q
PLASTIC LAMINATE COUNTER 0 3/4" x 25
34" A.F.F. WITH 1 1/2" EDGE W/1/2" LI
& 3 1/2" APRON, SS DOUBLE
BOWL SINK.
a
a
W
=
J
W
Certif' "SNO,
ruC��s�
m
low
TENANT
PROVIDED
Drawing Number:
A601
Of Sheets
Duke Job Number:
A/E Job Number:
24376
3
CEMAKER
A601 &REFRIGERATOR.
L--
2'-9"
1, 2'-9"
L 3'-0" L. S-5" t
BREAK ROOM 112
MILLWORK ELEVATION
SCALE: 1/2"=l' -On
BREAK ROOM 112
WALL ELEVATION
SCALE: 1/4"=l' -O"
I
�D
I
Engineering
`°
N
OPEN OP N OPEN
y
�
I
x
OPEN OPEN OPEN
WD1
7
I
WD1
V)
.5
0
0
I
n
LO
LO
5'-7%"
2'-6" 5'-4y"
2'-6"
0
I
2'-6"
29'-93/8"
L�
in
U
2'-6"
4'-6J/2" 2'-6" EQ 2'-6" EQ 2'-6" 4'-6Y2"
�
32'-2V4"
BREAK ROOM 112
WALL ELEVATION
SCALE: 1/4"=l' -O"
6
A601 COMP. SET UP 109
WALL ELEVATION
SCALE: 1/4"= 1'-0"
FILLER PANEL.
PLASTIC LAMIfTE (PI -1) COUNTER
AND 4" BACKISPLASH.
5/8" GYPSUM
BOARD.
3/4" PLYWOOD TO
BE BUTT JOINTED.
WOOD TO MATCH WD1.
3/4" PLYWOOD TO
BE BUTT JOINTED.
WOOD TO MATCH WD1.
1, h3/4" PLYWOOD TO
BE BUTT JOINTED.
WOOD TO MATCH WD1.
5/8" GYPSUM
BOARD.
OPEN OFFICE 113
9 WALL DETAIL
�01
SCALE: 1" = 1'-0"
TENANT PROVIDED COPIER.
COPY ROOM 111
CABINET ELEVATION
SCALE: 1/2"=V-0"
4'-0"
N CUSTOM PLASTIC LAMINATE
-UPE�— — — —R CABINETS W/ (2)ADJ.
\ \ i SHELVES AND 4"
WIRE PULLS PL2
PLASTIC LAMINATE COUNTER
N 36" A.F.F. WITH1 1/2" EDGE
PL1 & 4" BACKSPLASH.
OM PLASTIC LAMINATE
BASE CABINETS W/ (2)
ADJ. SHELVES AND
4" WIRE PULLS. p�
L
4' -0 -
I
Architecture
Engineering
`°
N
OPEN OP N OPEN
y
�
I
Corporate Office
280 East 96th Street, Suite 200
n
FAX 317.574.0957 ®Copyright 2001
WD1
V)
.5
0
0
I
LO
LO
5'-7%"
2'-6" 5'-4y"
2'-6"
5'-2y" 2'-6" 6'-1 4"
2'-6"
29'-93/8"
L�
6
A601 COMP. SET UP 109
WALL ELEVATION
SCALE: 1/4"= 1'-0"
FILLER PANEL.
PLASTIC LAMIfTE (PI -1) COUNTER
AND 4" BACKISPLASH.
5/8" GYPSUM
BOARD.
3/4" PLYWOOD TO
BE BUTT JOINTED.
WOOD TO MATCH WD1.
3/4" PLYWOOD TO
BE BUTT JOINTED.
WOOD TO MATCH WD1.
1, h3/4" PLYWOOD TO
BE BUTT JOINTED.
WOOD TO MATCH WD1.
5/8" GYPSUM
BOARD.
OPEN OFFICE 113
9 WALL DETAIL
�01
SCALE: 1" = 1'-0"
TENANT PROVIDED COPIER.
COPY ROOM 111
CABINET ELEVATION
SCALE: 1/2"=V-0"
4'-0"
N CUSTOM PLASTIC LAMINATE
-UPE�— — — —R CABINETS W/ (2)ADJ.
\ \ i SHELVES AND 4"
WIRE PULLS PL2
PLASTIC LAMINATE COUNTER
N 36" A.F.F. WITH1 1/2" EDGE
PL1 & 4" BACKSPLASH.
OM PLASTIC LAMINATE
BASE CABINETS W/ (2)
ADJ. SHELVES AND
4" WIRE PULLS. p�
L
4' -0 -
r5"'*�
A601 OPEN OFFICE 113
WALL ELEVATION
SCALE: 1/4"=11-0"
8
A601
A601 % SCALE: 1/2"=1'-0"
do
BLACK PAINTED REVEAL
2" BLACK PAINTED REVEAL
" CERAMIC BASE
3'-0"
00o I
0
�I O O
A
NOTE:
SINK PIPES BELOW ARE TO BE
WRAPPED FOR COMPLIANCE WITH
ADA GUIDELINES.
BLOCKING AS REQUIRED
SINK AND HARDWARE ABOVE
RETRACTABLE HAEFLEE
HARDWARE
INDICATES DOOR IN RETRACTED
POSITION
ADJACENT CABINET
RECESSED BASE LINE BELOW
ARROW INDICATES DIRECTION
OF MOVEMENT BY RECTACTABLE
CABINET
ASTRAGAL ON CABINET DOOR
TOUCH LATCH HARDWARE ON
CABINET FRONTS
ADA SINK
3 BASE SECTION
�11
SCALE: 1"=1'-0"
LOBBY WOOD
8 WALL SECTION
A601 SCALE: 1" = 1'-0"
EVEAL
ue
IFREALTY CORPORATION
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: 317 808-6000
ax: 317 808-6797
■
to
I
Architecture
Engineering
WD1
`D
OPEN OPEN OPEN
Corporate Office
280 East 96th Street, Suite 200
N
FAX 317.574.0957 ®Copyright 2001
WD1
V)
.5
0
0
I
LO
CM
a Q
4'-6Y" 2'-6"
EQ 2'-6" EQ 2'-6" 4'-6Y"
2'-6"
32'-3Y"
r5"'*�
A601 OPEN OFFICE 113
WALL ELEVATION
SCALE: 1/4"=11-0"
8
A601
A601 % SCALE: 1/2"=1'-0"
do
BLACK PAINTED REVEAL
2" BLACK PAINTED REVEAL
" CERAMIC BASE
3'-0"
00o I
0
�I O O
A
NOTE:
SINK PIPES BELOW ARE TO BE
WRAPPED FOR COMPLIANCE WITH
ADA GUIDELINES.
BLOCKING AS REQUIRED
SINK AND HARDWARE ABOVE
RETRACTABLE HAEFLEE
HARDWARE
INDICATES DOOR IN RETRACTED
POSITION
ADJACENT CABINET
RECESSED BASE LINE BELOW
ARROW INDICATES DIRECTION
OF MOVEMENT BY RECTACTABLE
CABINET
ASTRAGAL ON CABINET DOOR
TOUCH LATCH HARDWARE ON
CABINET FRONTS
ADA SINK
3 BASE SECTION
�11
SCALE: 1"=1'-0"
LOBBY WOOD
8 WALL SECTION
A601 SCALE: 1" = 1'-0"
EVEAL
ue
IFREALTY CORPORATION
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: 317 808-6000
ax: 317 808-6797
■
CSO
Architecture
Engineering
Interiors
Landscape Architecture
Land Surveying
Corporate Office
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 ®Copyright 2001
0
V)
.5
0
CM
a Q
o
L�
C
U
�
J
a
0
Z
Uj
X
Q
CO)
Loa
W
Z
Q
O ND
0
Z
� --Z
Z
a
a
V W ..
�W
�
Z v):2
O
Z
O
Q
U
�■
a
a
W
=
J
W
Certif' "SNO,
ruC��s�
m
low
STATE OF r
AA
Drawing Number:
A601
Of Sheets
Duke Job Number:
A/E Job Number:
24376
--------------
-1-71
CONF RM OFFICE OFFICE OFFICE
CONF. RM F1-0-4-1 F1051106 107
c1 103
C1 C1 OC,
C1
B1 P1 �¶ F-\ B1 P1 1 (I� 00 00
II II 8O 1 B1 PB1 P1 B1 P1
OPEN OFFICE
113
c1
B1 P1
CONFERENCE
(LjD 1 108
(Be
NORTH
ENLARGED
r_i"� FLOOR PLAN
A801 SCALE: 1/2" = 1'-0"
FINISH LEGEND:
FLOORCOVERINGS62 4" CERAMIC TILE BASE
MFG: CROSSVILLE
c1 CARPET - DIRECT GLUE SERIES: AMERICANA
MFG: J & J INDUSTRIES COLOR: AV114 GRAND CANYON
PATTERN: 2815 FILM FEST SIZE: 4"X12" BULLNOSE
COLOR: 1104 SOME LIKE IT HOT
WALLCOVERING
c2 CARPET - DIRECT GLUE W1 MFG: VERSA D.L. COUCH
MFG: ATLAS PATTERN: CARIBE
PATTERN: KAGO COLOR: A-47 HAITIAN
COLOR: 33 TAN STONE
aill MEN
—�
ONE
F_
CERAMIC TILE
Land Surveying
PATTERN: TBD
131
r%ION\
0
COLOR: TBD
o'
SERIES: AMERICANA
RECEPTION
A801
COLOR: AV114 GRAND CANYON
N
TD
m m
- ----- --10_1
SIZE: 12X12
r--
3
o
v
PLASTIC LAMINATE
o
MFG: ICI
v
CO)
P1
COLOR: 719 PILLAR
S
VINYL COMPOSITION TILE
OPEN OFFICE
113
c1
B1 P1
CONFERENCE
(LjD 1 108
(Be
NORTH
ENLARGED
r_i"� FLOOR PLAN
A801 SCALE: 1/2" = 1'-0"
FINISH LEGEND:
FLOORCOVERINGS62 4" CERAMIC TILE BASE
MFG: CROSSVILLE
c1 CARPET - DIRECT GLUE SERIES: AMERICANA
MFG: J & J INDUSTRIES COLOR: AV114 GRAND CANYON
PATTERN: 2815 FILM FEST SIZE: 4"X12" BULLNOSE
COLOR: 1104 SOME LIKE IT HOT
WALLCOVERING
c2 CARPET - DIRECT GLUE W1 MFG: VERSA D.L. COUCH
MFG: ATLAS PATTERN: CARIBE
PATTERN: KAGO COLOR: A-47 HAITIAN
COLOR: 33 TAN STONE
LAMINATE ON 3/4"
D W/
BACKSPLASH.
LAMINATE
f, AS REQUIRED.
COMP./SET UP 109
WORKSURFACE SECTION
SCALE: 1''= 1'-0"
GENERAL FINISH NOTES:
A. ALL DOORS TO BE FINISHED TO MATCH EXISTING DOORS.
B. ALL DOOR FRAMES TO BE FINISHED TO MATCH BUILDING STANDARD.
C. ALL WOOD TRIM TO BE FINISHED TO MA1CH EXISITNG STAIN.
D. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPORVAL OF ARCHITECT.
SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW.
E. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS
TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE
A SMOOTH TRANSITION FROM FINISH TO FINISH
F. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPETS IN PROJECT SCOPE
FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING
INSTALLATION.
G. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND
VINYL TILE TRANSITIONS TAKE PLACE.
H. VERIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS.
IF NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD.
I. EXISTING WOOD DOORS AND TRIM THAT ARE TO REMAIN ARE TO BE SANDED AND
TOUCHED -UP TO MATCH EXISTING STAIN.
J. PAINT NEW OR EXISTING PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT,
COLOR TO MATCH ADJACENT WALL FINISH.
K. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK, TO ARCHITECT
AND/OR DESIGNER FOR REVIEW AND APPROVAL, BEFORE PROCEEDING WITH
MILLWORK FINISHING PROCESS.
L. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH
INFORMATION.
M. EXTINGUISHER CABINETS) TO MATCH ADJ(ACENRISUf FACEEATERS, AND FIRE
N. ALL DRYWALL BULKHEADS ARE TO BE PAINTED (PX), UNLESS OTHERWISE NOTED
ON REFLECTED CEILING PLANS.
0. GROUT COLOR TO BE 100% EPDXY, COLOR TO BE SELECTED BY DESIGNER.
P. ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO
AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION.
FINISH PLAN NOTES:
F1 12" CARPET BORDER TO BE CT1
FINISHES TO MATCH EXISTING CORRIDOR FINISHES
F2
CSO
W2
MFG: TBD
cT1
CERAMIC TILE
Land Surveying
PATTERN: TBD
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
MFG: CROSSVILLE
0
COLOR: TBD
o'
SERIES: AMERICANA
W/ 4" BACKSPLASH.
A801
COLOR: AV114 GRAND CANYON
N
TD
m m
m�
'�
SIZE: 12X12
PAINT
3
o
v
PLASTIC LAMINATE
o
MFG: ICI
v
CO)
P1
COLOR: 719 PILLAR
VCT1
VINYL COMPOSITION TILE
Q
FINISH: EGGSHELL
X z W
MFG: ARMSTRONG
EQ EQ
EQ Q
a�EJa
PATTERN: STONETEX EXCELON
~ ~ U Q
J J
- a
COLOR: 52149 COCOA BROWN
a =
MFG: ICI
z
LL
P2
COLOR: 528 GOLDEN NEEDLES
vcT2
VINYL COMPOSITION TILE
'STATE OF
FINISH: EGGSHELL
Drawing Number:
MFG: ARMSTRONG
Of Sheets
Duke Job Number:
A/E Job Number:
STONETEX EXCELON
❑PATTERN:
COLOR: 52128 DESERT DUST
MFG: ICI
P3
o
COLOR: 1550 ARDEN FORGE
FINISH: EGGSHELL
VCT3
VINYL COMPOSITION TILE
MFG: ARMSTRONG
PATTERN: STONETEX EXCELON
PLASTIC LAMINATE
COLOR: 52150 PEAT GRAY
PL1
MANUFACTURER: NEVAMAR
COLOR: TM -2 -IT OCHRE TEMPERA
VCT4
VINYL COMPOSITION TILE
FINISH: MATTE
MFG: ARMSTRONG
PATTERN: STONETEX EXCELON
COLOR: 52156 BAMBOO YELLOW
F -PL -2-1
MANUFACTURER: NEVAMAR
COLOR: SH -2-2T MAIZE SHIBORI
FINISH: MATTE
BASE
S
VINYL BASE -4" COVE BASE
MANUFACTURER: JOHNSONITE
WOOD
FINISH
COLOR: 80 FAWN
WOOD STAIN AND SPECIES
wo1
TO MATCH HEAD QUARTERS LOBBY
LAMINATE ON 3/4"
D W/
BACKSPLASH.
LAMINATE
f, AS REQUIRED.
COMP./SET UP 109
WORKSURFACE SECTION
SCALE: 1''= 1'-0"
GENERAL FINISH NOTES:
A. ALL DOORS TO BE FINISHED TO MATCH EXISTING DOORS.
B. ALL DOOR FRAMES TO BE FINISHED TO MATCH BUILDING STANDARD.
C. ALL WOOD TRIM TO BE FINISHED TO MA1CH EXISITNG STAIN.
D. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPORVAL OF ARCHITECT.
SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW.
E. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS
TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE
A SMOOTH TRANSITION FROM FINISH TO FINISH
F. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPETS IN PROJECT SCOPE
FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING
INSTALLATION.
G. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND
VINYL TILE TRANSITIONS TAKE PLACE.
H. VERIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS.
IF NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD.
I. EXISTING WOOD DOORS AND TRIM THAT ARE TO REMAIN ARE TO BE SANDED AND
TOUCHED -UP TO MATCH EXISTING STAIN.
J. PAINT NEW OR EXISTING PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT,
COLOR TO MATCH ADJACENT WALL FINISH.
K. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK, TO ARCHITECT
AND/OR DESIGNER FOR REVIEW AND APPROVAL, BEFORE PROCEEDING WITH
MILLWORK FINISHING PROCESS.
L. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH
INFORMATION.
M. EXTINGUISHER CABINETS) TO MATCH ADJ(ACENRISUf FACEEATERS, AND FIRE
N. ALL DRYWALL BULKHEADS ARE TO BE PAINTED (PX), UNLESS OTHERWISE NOTED
ON REFLECTED CEILING PLANS.
0. GROUT COLOR TO BE 100% EPDXY, COLOR TO BE SELECTED BY DESIGNER.
P. ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO
AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION.
FINISH PLAN NOTES:
F1 12" CARPET BORDER TO BE CT1
FINISHES TO MATCH EXISTING CORRIDOR FINISHES
F2
COMP./SET UP 109
WORKSURFACE ELEVATION
SCALE: 1/2"= V-0"
NOTE: MAX. OF 4'-0" BETWEEN
SUPPORT PANELS.
FDUke
st 96th Street
00
polis, IN 46240
{317) 808-6000
(317) 808-6797
CSO
i
OPEN
OPEN
�
OPEN
Land Surveying
Corporate Office
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
325"
0
DEEP WORKSURFACE
o'
R
Oll
W/ 4" BACKSPLASH.
A801
PO -71
N
TD
m m
m�
'�
v CO
a r
\
o r
3
o
v
PLASTIC LAMINATE
o
o
v
CO)
SUPPORT, AS REQUIRED.
— 0
Q
PO -71
X z W
EQ
EQ EQ
EQ Q
COMP./SET UP 109
WORKSURFACE ELEVATION
SCALE: 1/2"= V-0"
NOTE: MAX. OF 4'-0" BETWEEN
SUPPORT PANELS.
FDUke
st 96th Street
00
polis, IN 46240
{317) 808-6000
(317) 808-6797
CSO
Architecture
Engineering
Interiors
Landscape Architecture
Land Surveying
Corporate Office
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 ®Copyright 2001
0
Ln
Q)
o'
R
Oll
N
TD
m m
m�
'�
v CO
a r
\
o r
3
o
v
cn
o
o
v
CO)
z
— 0
Q
Z >
X z W
CoJ
W to o W
Z 0 NZ
Z - Q
a�EJa
zW
D
H- 0 W Z
~ ~ U Q
J J
- a
a =
= CO)
z
LL
Certif'
r
AM10036 )
'STATE OF
Drawing Number:
A801
Of Sheets
Duke Job Number:
A/E Job Number:
24376
i
280 280 1 330
CFM CFM CFM
E. ,.r ,rtsp�
tq'
Ob
1
n
i
.._, R
CONE.
CNF. R:, . __ I _ R d—.
��._Y � _ �QNF RSI
101
K 103
104
# c 1210
\r
12T � -=� �Y � �t 3T y
1 IW0B
8"0.:
, I r
I 220 220
I yt,GFM CF
1iQ a i q
c
` � p
s ` I'i� ♦ rip § ?� ''\3 \ i
A 4: 1 1 .5T — +- ' � 3T
r
-- 00
L 110 8"0 L
CFM
220 1 220
b
._ CFM
�RECEPTION'v
i
s �I
i
102. �I
ycI
r
WA
FAffA , ra 0, MA
FzrzzAPff' ...........
M
310
CFM
JLWS-ly6 11-1y4A
300 300 1 300
CFM CFM I CFM
150
CFM
1 t z }
1 ,
/0 If8"o
d I "� „
11"WO
150r
—
I C
8„0 250
CFM
OFFICE
F
ate' 4.
I
fl
OFFICE OFFICE
I IfE-- __ -- _—_ _. —_ --- -- cod — {1;, ._.__—. .___.�•`� _. _ .�'-�__-.__„_.__ _ ;ry”
- 1,106
----- - ---- _
—107
—
:3
,f
"• -' ; r � � , , .: I! • i IIA. ; � , , � i °yv , [ / �. �` ,�'_ ; ,_.:: F
{� E ...ENCS
d
it
W,
/i
I
v V
1 _ . ,,, 108
' ', A i � '� , a V' r 1 0
.
1..2...m -.\J
_- > -
TENANT _ ; ; 14
220 119 L / Q
CFM 270 270 �� 1 .0 265CEM
8"0
10„� 10„0 t0b0
F7-/
F _ _
m..R
0 10 m \, , r k.\ 265 ,
ML10„o a
°O f 3T
L
1 _ i 8.0
220 _ I f ,
_•r r
�.:. CFM
8"0 COFFEE ;I x�_
1 f ( :A
SBR a � IAll
3T _,, M 4I a
i >
5
i I
1 170 ,� /' t L 10 0 z
,i
_..__.-CFM „ i f _ r _ _'� - �..a,„ ws� __ � _.� ` �m
_CFM _8„� COPY - 8 b� i - i1 10 —265 / j_ CFM
111 I _
8
d,
k14"d I
:
w
t a
3TI\
395
w w I I
V` „�
T�
I
1T 1
( I
,y
v ,
00
4F s
3 _.
-
F f
3
E ;
,F71
_
a I
,,� • /1 1 365 i; � � .__., �, F \ � � +E � 0 � �.�.,� �,�a��:� �v,�� _ Y
`CFM_''E.C.;CFM g 305
pi
� \ t% `T
/ s 11 CFM',
_
I
o
d IF IL
1
ri 4`
.0
s a e'
{�
' COMP SET UP
„ r
r
s � 10' I
E
I
`.c
_ __ EXIT CORRIDOR
FIRST FLOOR HVAC PLAN
scnce��=r-0^
250
CFM
300
CFM
CFM GENERAL NOTES:
1.A
LL DUCT GALVANIZED CONSTRUCTION
2.ALL NEW DUCT,FLEX,DIFFUSERS,GRILLES AND REGISTERS
200
CFM
200
CFM
200
CFM
Duke
600 Fast 96th Street
Sure 1100
indionc:polis, iN 4.6240
Phone; (317) 808-6000
Fox: a317) 808-679'
1BMGlMS= 141!>ErALC®14?MY1NC.
2749 TOBEY DRIVE * INDIANAPOLIS, IN. 46219
(317)895-3939 * Fax (317)895-3940
(ONSMANTS
7825 E. 89th STREET
FG INDIANAPOLIS, INDIANA 46256
MQlnft B h1C (317)849-521' FAX: (317; 576.1;_'24
mmfgenaireers.com
O
d'
1
0
J
t�
00
a
�'
z
v
r '
Drowinq Number:
SNI -1
Of Sheets
Duke -Meeks uv'b, Number:
A/E Job Number:
1404-192
/
Q
J
t�
a
z
Q
z
U
Q
♦cf)
V /
Ln
Q
0
CN
z
0
0
Cn
Ir
U
LL
.J
Z
U.
Drowinq Number:
SNI -1
Of Sheets
Duke -Meeks uv'b, Number:
A/E Job Number:
1404-192