Loading...
HomeMy WebLinkAboutC001 TITLE SHEET116th ST.DITCH RD.NO SCALE HAMILTON COUNTY PROJECT LOCATION PROJECT LOCATION LOCATION MAPAREA MAP CITY OF CARMEL STANDARD NOTES DESIGN DATA EXISTING ZONING S1 DISTRICT ZONING OVERLAY W 116TH ST OVERLAY TOTAL ACREAGE 38.68 ACRES BUILDING AREA (TOTAL PROPERTY) 4.95 ACRES BUILDING COVER RATIO (TOTAL PROPERTY) 13% PROJECT AREA (DISTURBED AREA) 4.29 ACERS PROJECT AREA IMPERVIOUS COVER 560.00 SQUARE FEET IMPERVIOUS COVER RATIO 0.30% W S N E CITY OF CARMEL PLANNING ONE CIVIC SQUARE CARMEL, IN 46032 ANGIE CONN / ALEXIA LOPEZ TEL: 317/571-2417 CITY OF CARMEL ENGINEERING ONE CIVIC SQUARE CARMEL, IN 46032 JOHN THOMAS / ALEX JORDAN TEL: 317/571-2441 CITY OF CARMEL BLDG SERVICES ONE CIVIC SQUARE CARMEL, IN 46032 BILL HOHLT TEL: 317/571-2444 CITY OF CARMEL FIRE DEPARTMENT TWO CIVIC SQUARE CARMEL, INDIANA 46032 CHRIS ELLISON TEL: 317/571-2600 CARMEL CITY UTILITIES 30 W MAIN ST, SUITE 220 CARMEL, INDIANA 46032 JOHN DUFFY TEL: 317/571-2648 HAMILTON COUNTY SURVEYOR ONE HAMILTON COUNTY SQUARE SUITE 188 NOBLESVILLE, INDIANA 46060 SAM CLARK TEL: 317/776-8495 HAMILTON COUNTY HEALTH DEPARTMENT 18030 FOUNDATION DR. SUITE A NOBLESVILLE, INDIANA 46060 JASON LEMASTER TEL: 317/776-8500 TRICO REGIONAL SEWER UTILITY 7236 MAYFLOWER PARK DR. ZIONSVILLE, IN 46077 RYAN HARTMAN TEL: 317/844-9200 DUKE ENERGY 100 SOUTH MILL CREEK RD. NOBLESVILLE, INDIANA 46060 TEL: 317/776-5352 COMCAST 9750 E. 150th STREET SUITE 1600 NOBLESVILLE, INDIANA 46060 TEL: 317/776-4495 VECTREN GAS P.O. BOX 1700 NOBLESVILLE, INDIANA, 46060 TEL: 317/776-5573 AT&T 5858 NORTH COLLEGE INDIANAPOLIS, INDIANA 46220 TEL: 317/252-5168 OPERATING AUTHORITIESGENERAL NOTES CONSTRUCTION PLANS FOR PRIVATE BALLFIELD 11303 DITCH ROAD CARMEL, IN 46032 LAND DESCRIPTION BENCH TIE SET +1' ABOVE GRADE IN THE EAST SIDE OF A UTILITY POLE ON THE WEST SIDE OF DITCH ROAD. SAIDS UTILITY POLES FALLS +34' WEST OF THE CENTERLINE OF DITCH ROAD AND +110' SOUTH OF THE CENTERLINE OF PICKWICK LANE ELEV. 864.56' (NAVD 88) BENCHMARK INFORMATION PLANS PREPARED FOR PRIVATE BALLFIELD 11303 DITCH ROAD CARMEL, IN 46032 TELEPHONE: (317) 514-7383 CONTACT PERSON: PETE CLEMENS EMAIL: PCLEMENS@LUCASOIL.COM W230487-C001 titleC001TITLE SHEETW23.0487ABW23.048704/26/2024WSWSPRIVATE BALLFIELD11303 DITCH ROAD, CARMEL, IN 46032PLANS PREPARED BY WEIHE ENGINEERS, INC. 10505 N. COLLEGE AVE. INDIANAPOLIS, INDIANA 46280 TELEPHONE: (317) 846-6611 FAX: (317) 843-0546 CONTACT PERSON: BILL SCHMIDT EMAIL: SCHMIDTB@WEIHE.NET 1.NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT 2.THESE PLANS COMPLY WITH ALL ADA REQUIREMENTS. 3.UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE OWNER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 4.ALL EXISTING PERIMETER ROAD DRAINAGE STRUCTURES AND BRIDGES ACROSS THE FRONTAGE OF THIS DEVELOPMENT ARE INDICATED ON THE PLANS. PROVISIONS HAVE BEEN MADE TO IMPROVE OR REPLACE ANY DRAINAGE STRUCTURES AND BRIDGES AS NECESSARY OR AS REQUEST BY THE CITY TO ACCOMMODATE THE PAVEMENT WIDENING, AUXILIARY LANES, MULTI-USE PATH, AND ANY OTHER REQUIRED IMPROVEMENTS TO THE PROPERTY OR THE ROADWAY. THE COST TO IMPROVE OR REPLACE ANY DRAINAGE STRUCTURES AND BRIDGES WILL BE BORNE BY THE DEVELOPER. 5.DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 6.ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT -OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. 1.THESE PLANS ARE BASED ON A SURVEY PREPARED BY WEIHE ENGINEERS DATED 04/04/2024. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY THAT THE IMPROVEMENTS EXIST AS SHOWN ON THE SURVEY. THE CONTRACTOR IS RESPONSIBLE FOR NOTIFYING THE OWNER CONSTRUCTION MANAGER AND THE ENGINEER OF ANY DEVIATIONS OR OMISSIONS THAT MAY EFFECT THE CONSTRUCTION OF THE PROPOSED IMPROVEMENTS. 2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING, OR VERIFYING THAT ALL PERMITS AND APPROVALS ARE OBTAINED FROM THE RESPECTIVE CITY, COUNTY, AND STATE AGENCIES PRIOR TO STARTING CONSTRUCTION. 3.IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES IN THE VICINITY OF THE CONSTRUCTION AREA PRIOR TO STARTING CONSTRUCTION 4.IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO NOTIFY AND COORDINATE CONSTRUCTION WITH ALL RESPECTIVE UTILITIES. 5.ALL QUANTITIES GIVEN ON THESE PRINTS, VERBALLY OR IN THE SCOPE OF WORK SECTION ARE ESTIMATES AND SHALL BE CONFIRMED BY THE BIDDING CONTRACTORS. 6.OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29 CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. 7.EXCAVATIONS EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRE THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER. 8.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN QUALITY CONTROL THROUGHOUT THIS PROJECT. 9.THE ENGINEER AND/OR OWNER DISCLAIM ANY ROLE IN THE CONSTRUCTION MEANS AND METHODS ASSOCIATED WITH THE PROJECT AS SET FORTH IN THESE PLANS. 10.ANY FIELD TILES ENCOUNTERED DURING EXCAVATION SHALL BE REPAIRED AND CONNECTED TO NEW STORM SEWERS AND POSITIVE DRAINAGE PRESERVED. 11.THE SITE DOES NOT LIE IN A SPECIAL FLOOD HAZARD AREA AS ESTABLISHED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY - NATIONAL FLOOD INSURANCE PROGRAM, WHEN PLOTTED BY SCALE ON FLOOD INSURANCE RATE MAP #18057C0208G, DATED 11/19/2014. 12.BEARINGS, DIMENSIONS AND EASEMENTS ARE SHOWN FOR REFERENCE ONLY. SEE RECORD SURVEYS & PLAT FOR EXACT INFORMATION. 13.THIS SITE DOES NOT CONTAIN ANY WETLANDS AT SHOWN ON THE U.S. DEPARTMENT OF THE INTERIOR FISH AND WILDLIFE SERVICE;INDIANA, NATIONAL WETLANDS INVENTORY MAP. 10 9abcd 8 7 6efgh109876 5 4 3 2 1 PREPARED FOR:PROJECT NO. SHEET NO.abcd5 4 3 2 e1 fhAPPROVAL PENDINGNOT FOR CONSTRUCTIONISSUED FOR CITY REVIEW04.26.2024WGS1gALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape Architecture05/09/2024PROJECT NO.:REVISIONS AND ISSUESDATEBYDWG NAME:DESIGNED BY:DRAWN BY:CHECKED BY:DATE:Know what's below. before you dig.Call R DARRELL A. EDWARDS P.E. #890047SPRING MILL RD.106th ST. 116th ST. 106th ST. 131st ST. 146th ST. 141st ST. 96th ST.TOWNE RD.SPRING MILL RD.DITCH RD.I-465 I-465US-421US 31Sheet List Table Sheet Number Sheet Title C001 TITLE SHEET C002 GENERAL NOTES C101 STORMWATER POLLUTION PREVENTION PLAN PHASE I C102 STORMWATER POLLUTION PREVENTION PLAN PHASE II C103 STORMWATER POLLUTION PREVENTION PLAN SPECS. C104 STORMWATER POLLUTION PREVENTION PLAN DETAILS C105 STORMWATER POLLUTION PREVENTION PLAN DETAILS C200 SITE PLAN C201 SITE PLAN DETAILS C300 GRADING PLAN C600 DRAINAGE PLAN C602 DRAINAGE PLAN DETAILS L100 LANDSCAPE PLAN L101 LANDSCAPE PLAN DETAILS