Loading...
HomeMy WebLinkAbout04120037 Site Plan Scmeider Tho Schneider CorporaUoD 8901 otis Avenue Historic fon Harrison Indianapolis. Indiana 48216-1037 317-826-7100 317-826-7200 fAX ~ 3une7iD& landJcape Architeclure GIS 'US GeoIoU Plot Plan Prepcred for: R.H. of IndiCll!ft lot # 50, contoillng 8,218 5.F.:I:, In Stonford POlk Section # 1 Instrument # Unrecorded P.C. # X. Slide # X Clay Twp, HomDton County Sec 20, T29N, R3E 13811 Pmo Alto Court (SO' R/Yf) Prepcred Date: 00/16/04: By. J(J Proposed Bu)'8l'(8~ Model Home Plot Plan legend Community Restrictions: Side Yard =3' min. Rear Yard = N/A Aggregote = 6 (B.H.) []QQ]] Proposed Grades 000.0 Existing Grades __ 000.0-- Contour Grade * Approx. lateral location - . - Sanitary Sewer Lines -... - Storm Sewer lines - 1J - Water Service Lines - - - - - - - Sub-Surface Drain lines . Manhole (Sanitary or Storm) . Beehive Inlet (Storm) 11III . Curb Iniet (Storm) D End Section (Storm) ... fire Hydrant - 000 - "0" -Row line of swale Building Line (Bl / BSl) - - - - - - - Easement Line finished floor Elevation Information Pod Grode = 916.1 per pion Pod Grade + 0.7' = Garage FIT (916.8) (Bsmt) Gorage FIT + 1.5' = Residentiol FFE (918.3) Residential FIT - 9.0' = Basement FIT (909.3) Sanitary Sewer Costing Information Upstream Monh~e, TC= 916.10 Downstream l.lanhole, TC= 915.90 per plan. Note: Sump pump(s) to be ploced by builder as needed. Sidewalk to be placed l' from property line, 4' from back of curb, per plan. . ~I ~, ~ TYPICAL SWALE SECTION Sod Calculations: Drive = 784 Sf.! Public Wok = 230 SH PriYllte Walk = 53 Sf::t: Sod = 226 Sri , ~om rear of home. H)droseeding = 3,690 Sf.! Note: I This drawing is based on construction plans or record drawings, and is not based upan a field survey. The Schneider COrporation does not warrant the accuracy Of sufficiency of this information. Contractors should verify existing conditions prior to ony construction. Any discrepancy found on this drawing sh:ould be reported to The Schneider Corporation immediately, failing to do so results in the contractors ossumption of 011 liability'! I Note: I The basement elevation, depicted hereon, has been determined and based upon the pad grades and/or contours taken from the construction plans for this subdivision. Unless stated, no information about fluctuating water tobles, soil conditions, or soD t)pes' has been provided or stated on said plans. It is recommended that the basement finished floor elevations be at least two feet (2') above the normal pool elevation of any adjoining bodies of water, unless a study of facts reveals otherwise. If during the excavation process any ground water Is witnessed, The Schneider Corporation should be notified immediately. The ba;;;ement elevotion should be raised two froet (2') above the ground woter, and additional construction techniques should be incorporated to alleviate future problems. Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-five feet (25'), however a dwelling may be increased in height to thirty-five feet (35') provided the side and rear yards are increased on additional one foot (1') for each ooe foot (1') the structure exceeds the first twenty-five feet (25') in height. DetaD of Ground/ Storm Water flow pattern for individuollots. VB04.0022994 Lot # 60 ~ ~ I =~=I ! ~ Assumed North Scale: 1- = .10' :g: '0' I I \ I Note: BuUder to ensure positive drainage away from structure(s). Note : The garage finished noor elevation is 1.4' above the curb at the drive, per plan. ~ i'" g ill , 131.92' >, , ~~ ! , , , , I > I !i~ I jl\1:! m )> ~ '". Ie ~49.5' I n z I 2 lO ~ r- II > --I ill~ 26.0' 61.5' 0 en I, ~~ . '" U; ~ 0 '" -\ q I"; "'" 1 ~ ~ Cl 0 I~ I c I I >, :::0 , --I I JI^ 131.92 , Ii , I , 59.5' TC=915.90 PER PUN NOTE: THE WITHIN PLOT PLAN WAS PREPARED AT THE CLIENT'S REQUEST WITHOUT BENEFIT OF A RECORD PLAT, THE CONTRACTOR AND/OR BUILDER HAS BEEN CAUTIONED THAT THE DEPICTED LINES SHOWN HEREON ARE SUBJECT TO CHANGE.