HomeMy WebLinkAbout04120053 Site Plan
0 uJ' t:J I
<( ~I I -il
0 ~ CD 38.76'
D:::: """ ""'I I 0
"-
...- RE~OENCE IS ON OR NEAR PROPERTY UNE
I- .......
-' 3' WALK
W """ <<>-
:z: :I: '" ~Q;:~LiJ
"- 26.5' N
l/l I U") E5d~ffi
D:::: """ en ...-
0 "" c d
'0 I 30.5' g>-,~w N
OJ _HI) '"
38.76'
-.J \. RE~OENCE IS ON OR NEAR PROPERTY UNE
W 30.0 .......
:::r:: ~--
(J) R.D.E.
sf1
The Schneider Corporation
6901 Otis Avenue
Historic Fort Harrison
IDdleDapolls. IDdIeDa 462l6-1037
317-626-7100
317-626-7200 FAX
En&lneeriDI
Sunoylna
LandJcape Arcll!toct....
GIS .113
Geo1<>&l'
Plot P1C111 Prepared for: R.H. of Indiana
BLOCK 1 Lot' 268, containing 2,028 5.F.:t, In
Stanford POlk
SectIon" 3
I stru t , U ---l.... [@l) Proposed Grades
n men n............. 000.0 ExI.tilg Grades
pc., X. Slide' X _000.0- Contour Grode
. * App". lot... locatloo
Oay Twp, HamDton County - . - Sanlt..y Sew.. Liles
-.- Storm Sewer Liles
See 20, T29N, R3E - , - Wat.. s.n.;", Unes
GOlDEN GAlE DRIVE (?" R /vii - - - - - - - Sub-Surla", O"ln Unes
~ . ~\_.tt- IWJ~ --~.--Monhoie-(Saiiaarfur-Slur((\)
Dra.v.r...t Date: 11/18/2004' By. NAA . Beohl.. Inl.t (St,,",,)
, '''1''''- . . III Curt> Inl.t (5t,,",,)
Proposed Buyer(8~ SPEc. 0 End SooUoo (St,,",,)
..... F'n H~rant
- 00. _ 00. -Flow Una of swale
- Buldilg Uno (Bl / Bst)
------- EasementUne
Plot Ploo Leqend
Community Restrictions:
Side Yard =3' min.
Rear Yard = N/A
Aggragat. = 6 (B.H.)
Sanitary Sewer Costing Information
Upstraam Manhot.. TC= 916.90
Downstream Manhole, Te= 916.40
per pion
Finished Floor Elevation Information
Pad Grade "" 91; per plan
Pad Grad. + O. = Garog. FIT (917.6)
(Slab) Garog. FIT " = R. . ential FIT (91B.1)
Sod Calculations:
Drive = 195 SF:I::
Privote Walk = 189 SF:I::
Sad = 96 SYi , whot. )<Ird
Note:
The contractor is to maintain 0 minimum
distance of ten feet (10') between the
sanitry sewer and water line laterals.
Nota:
This drawing is based on constructioo plans or record drawings,
and is not based upon a field survey. The Schneider Corporation
does not warrant the accuracy or sufficiency of this information.
Contractors should verify existing conditions prior to any
construction. Any discrepancy found on this drawing should be
r'Port.d to Th. Schneid" Carporatian imm.diot.ly. failing to do
so "suits in tho contractors assumption of all liability.
Note:
Buader to ensure positive drainage
away fram struclura(s).
Lot # 268
Vb04,0026098
O.tai af Ground/ Staim
Water flow pattern for
individual lots.
t t
t \ I I
,UII
, I \ , I
~
~
=~=
~~
b
. ;.!. ~ l
TYPICAL SWAL.E SECTION
~
Assumed North
Scale: 1- = 20'
NOTE: THE II1THIN PLOT PLAN WAS
PREPARED AT THE CLlENIS
REQUEST II1THOUT BENEFIT OF A
RECORD PLAT. THE CONTRACTOR
AND lOR BUILDER HAS BEEN
CAUTIONED THAT THE DEPICTED
LINES SHOWN HEREON ARE SUBJECT
TO CHANGE.
m
~ I
0101
~I
"'I
I
I~
x
<
I
1
-t
W
::>
D::::I-
01:5
, :::;;
W
Wl/l
f-'-LJ
<el/l
C)~
0::
<!>
w
:z: ........
W~
O~
-.J~
0.-
C):"
""
u
o
-'
CD
REVISION #1
CHANGED LOT NUMBERS
12/08/04 AMA
Note:
Per Carmel zoning ordinance 26.1.1 :
The residential district limits height to twenty-five
feet (25'), however a dwelling may be increased in height
ta thirty-fi", f"t (35') providad tho sid. and roar )<Ird.
are increased an additional one foot (1') for each
one foot (1') the structure exceeds the first
tw"ty-fi.. I"t (25') in h.lghl