Loading...
HomeMy WebLinkAbout04120053 Site Plan 0 uJ' t:J I <( ~I I -il 0 ~ CD 38.76' D:::: """ ""'I I 0 "- ...- RE~OENCE IS ON OR NEAR PROPERTY UNE I- ....... -' 3' WALK W """ <<>- :z: :I: '" ~Q;:~LiJ "- 26.5' N l/l I U") E5d~ffi D:::: """ en ...- 0 "" c d '0 I 30.5' g>-,~w N OJ _HI) '" 38.76' -.J \. RE~OENCE IS ON OR NEAR PROPERTY UNE W 30.0 ....... :::r:: ~-- (J) R.D.E. sf1 The Schneider Corporation 6901 Otis Avenue Historic Fort Harrison IDdleDapolls. IDdIeDa 462l6-1037 317-626-7100 317-626-7200 FAX En&lneeriDI Sunoylna LandJcape Arcll!toct.... GIS .113 Geo1<>&l' Plot P1C111 Prepared for: R.H. of Indiana BLOCK 1 Lot' 268, containing 2,028 5.F.:t, In Stanford POlk SectIon" 3 I stru t , U ---l.... [@l) Proposed Grades n men n............. 000.0 ExI.tilg Grades pc., X. Slide' X _000.0- Contour Grode . * App". lot... locatloo Oay Twp, HamDton County - . - Sanlt..y Sew.. Liles -.- Storm Sewer Liles See 20, T29N, R3E - , - Wat.. s.n.;", Unes GOlDEN GAlE DRIVE (?" R /vii - - - - - - - Sub-Surla", O"ln Unes ~ . ~\_.tt- IWJ~ --~.--Monhoie-(Saiiaarfur-Slur((\) Dra.v.r...t Date: 11/18/2004' By. NAA . Beohl.. Inl.t (St,,",,) , '''1''''- . . III Curt> Inl.t (5t,,",,) Proposed Buyer(8~ SPEc. 0 End SooUoo (St,,",,) ..... F'n H~rant - 00. _ 00. -Flow Una of swale - Buldilg Uno (Bl / Bst) ------- EasementUne Plot Ploo Leqend Community Restrictions: Side Yard =3' min. Rear Yard = N/A Aggragat. = 6 (B.H.) Sanitary Sewer Costing Information Upstraam Manhot.. TC= 916.90 Downstream Manhole, Te= 916.40 per pion Finished Floor Elevation Information Pad Grade "" 91; per plan Pad Grad. + O. = Garog. FIT (917.6) (Slab) Garog. FIT " = R. . ential FIT (91B.1) Sod Calculations: Drive = 195 SF:I:: Privote Walk = 189 SF:I:: Sad = 96 SYi , whot. )<Ird Note: The contractor is to maintain 0 minimum distance of ten feet (10') between the sanitry sewer and water line laterals. Nota: This drawing is based on constructioo plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be r'Port.d to Th. Schneid" Carporatian imm.diot.ly. failing to do so "suits in tho contractors assumption of all liability. Note: Buader to ensure positive drainage away fram struclura(s). Lot # 268 Vb04,0026098 O.tai af Ground/ Staim Water flow pattern for individual lots. t t t \ I I ,UII , I \ , I ~ ~ =~= ~~ b . ;.!. ~ l TYPICAL SWAL.E SECTION ~ Assumed North Scale: 1- = 20' NOTE: THE II1THIN PLOT PLAN WAS PREPARED AT THE CLlENIS REQUEST II1THOUT BENEFIT OF A RECORD PLAT. THE CONTRACTOR AND lOR BUILDER HAS BEEN CAUTIONED THAT THE DEPICTED LINES SHOWN HEREON ARE SUBJECT TO CHANGE. m ~ I 0101 ~I "'I I I~ x < I 1 -t W ::> D::::I- 01:5 , :::;; W Wl/l f-'-LJ <el/l C)~ 0:: <!> w :z: ........ W~ O~ -.J~ 0.- C):" "" u o -' CD REVISION #1 CHANGED LOT NUMBERS 12/08/04 AMA Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-five feet (25'), however a dwelling may be increased in height ta thirty-fi", f"t (35') providad tho sid. and roar )<Ird. are increased an additional one foot (1') for each one foot (1') the structure exceeds the first tw"ty-fi.. I"t (25') in h.lghl