Loading...
HomeMy WebLinkAbout04120057 Site Plan Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey. The Schneider, Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any constructioo. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; foiling to do so results in the contractors assumption of all liability. Note: Bu~der to ensure positive drainage away from structure(s). ~~ Scmeider The Schneider Corporation 8901 otia Avenue Historic Fort Harrison ludlaoapollio, Iud!"", 4<l216-1037 317-626-7100 317-626-7200 fAX ~ 3urveyiDg I.aJubcape ArchII.dun GIll.US GeoIOD Plot Pllll Prepared for. R.H. of Indlono BLOC< 1 Lot' 271, contolnlng 2,089 5.r.:i:, In Stonford Park SectIon f3 Instrument , Unrec:orded P.c. , X. Slide , X Clay Twp, HcrnDtonCounty See 20, T29N, R3E _GOLDEN GAlE DRI\'E (24' R/W) l'rep<I'ed Date: 11/18/2004: By. NAA Proposed Bu)'8l'(s}. SPEc. OeteU of Ground/ Storm Water flow pattern for individual lots. Plot Pion leqend Lot # 271 Vb04,0026102 ~ Proposed Grades 000.0 ExistilgGrodes _000.0- Contour Grode * Approx. lotfl(al location - . - SanJtCl'Y Sewer Liles -.- Starn Sewer Liles - w - Water SeMce Unes - - - - - - - Sub-Surface Drain lines . Manhole (SanitCl'y or Storm) . Beeiiive-lnleqStarn) -- ill Curb Inl.t (StO'Tll) D End Section (StO'Tll) A fn H~rant - ... - ... -Row Une of swale - Bui~"g LIn. (Bl / BSL) ----~-- EasementLile t t t \ I I In, ,~, ~ ~ =~= ~ Assumed North Scale: 1- = 20' ~. ~ b '1 .1 ~t - ., TYPICAl SWALE SECTlON Community Restrictions: Side Yard =3' min. Reor Yard = N(A Aggregate = 6 (S.H.) Sanitary Sewer Casting Information Upstream Manhole, TC= 916.90 Downstream Manhole, TC= 916.40 per plan evotion Information er plan = Gar09' FFE (917.6) 0.5' = Residential FFE (918.1) NOTE: THE WITHIN PLOT PLAN WAS PREPARED AT THE CLIENT'S REQUEST WITHOUT BENEFIT OF A RECORD PLAT. THE CONTRACTOR AND lOR BUILDER HAS SEEN CAUTIONED THAT THE DEPICTED LINES SHOWN HEREON ARE SUBJECT TO CHANGE. Sod Calculations: Drive = 225 SF:I: Privet. Walk = 181 SF! Sod = 96 SYi , whole }'Ird o <( o 0::: W :z: 0::: o m ---1 W ::r::: (/) w > - ,., 0::: <Xl .,; * 0 0; 15,0'.. - ~ W "'- I- ~c:: <( Cl 81 * i3 C) :z: no' Ww CI::l'" . "'" ...l..Jw CD~ Ow . c:: "" ~ '" '" w c:: "" :z . ."'" ::.: '-' 0 --' m 30.5' ,-,. u:- 38.16f1' '" RE~DENCE IS ON OR NEAR PROPERTY UNE -..... CDCD>- N ~~~w a, d ffid~a5 ~ N 0: .:::EQ g~a:~ 38.76' RE~DENCE IS ON <ll NEAR PROPERTY UNE <<>- F "'" c... I- --' "'" :I: c... '" "'" o 3' WALK 24.5' ~I ~I 28.5' ~ I I Lo I I \. ~ 30, R.D,E. Note: The contractor is to maintain a minimum distance of ten feet (10') between the sanitry sewer and water line laterals. REVISION #1 CHANGED LOT NUMBERS 12(08(04 AMA Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-five feet (25'), however a dwelling may be increased in height to thirty-five feet (35') provided th6 side and rear }Ords are increased an additional one foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height.