HomeMy WebLinkAbout04120058 Site Plan
~~
Schneider
The Schneider Corporation
89010UsAvenue
Bistorlc Fort Harrisoo
bldlaDapoIla. IlIdiaDa _6-1037
317-626-7100
317-626-7200 FAX
EnaJneerln&
s.n.ym"
LondJcape ArcldtecbJn
GJ:l.llS
Geology
Plot P1C1l Prepared for: R.H. of Indiana
III..Oa( 1 Lot # 272, contoililg 2,029 S.F.:I:, il
Stanford Park
SectlCIl # J
Instrument # Unrecordecl
P.c. # X. Slide # X
Cay Twp, HomDtCll County
see 20, T29N, RJE
_GallEN GAlE DRIVE (24' RjW)
Prepcred Dote:_ll/18/2004":_Ily._AIIA
Proposed Buyer{s}. SPEc.
Community Restrictions:
Side Yard =3' min,
Reer Yard = N/A
Aggregate = 6 (S.H.)
P10tPlalleqend
l]OOJ] Proposed Grades
000.0 ExistilgGrodes
_000.0- Contour Grode
* Approx. Lateral location
- . - SonitCl"Y Sewer Liles
-.- Storm Sewer Liles
-v-WoterServlceUnes
- - - - - - - Sub-Surface Drain lines
. Manhole (Sonitay or Storm)
. Beehive Inlet (Storm)
- -lii- . - Curt> '"'ot (Storm)-
D EIld SOCU", (Storm)
..... FhHpont
- 0.0_ ... -Row Line of swole
- Bul,ng UIl. (Bl / BSt.)
------- EasementLile
Sanitary Sewer Costing Information
Upstream Woohale, TC= 916.90
Downstream lAanhole, TC= 916.40
per plan
Finished Floor Ele
Pad Grade = 916.9
Pad Grade + 0.7' =
(Sob) Gorage fFE +
Information
100
e fFE (917.6)
Res" tial fFE (918.1)
Sod CalctJlations:
Drive = 195 SH
Private Walk = 189 SF!
Sod = 96 SYf , whalo }Ord
Note:
The contractor is to maintain 0 minimum
distance of ten feet (10') between the
sanitry sewer and water line laterals.
Note:
This drawing is based on coostruction plans or record drawings,
and is not based upon a field survey. The Schneider Corporation
does not warrant the accuracy or sufficiency of this informatioo.
Contractors should verify existing conditions prior to any
construction. Any discreponcy found on this drawing should be
reported to The Schneider Corporation immediotely, foiling to do
so results in the contractors assumptioo of aU liabmty.
Nate:
Buijder to ensure positive drainage
away from structure(s).
Detail of Ground/ Storm
Water flaw pattern for
individuallats.
Lot # 272
Vb04, 0026103
o
~
=~=
o
Assumed North
Scale: I" = 20'
I I
t \ I I
,Pi
I ,
. ~I E
~
TYPICAl SWALE SECTION
NOTE: THE WITHIN PLOT PLAN WAS
PREPARED AT THE CLlENrS
REQUEST WITHOUT BENEFIT OF A
RECORD PLAT. THE CONTRACTOR
AND lOR BUILDER HAS BEEN
CAUTIONED THAT THE DEPICTED
LINES SHOWN HEREON ARE SUBJECT
TO CHANGE.
TC-916.90
PER PLAN
0
<:( I ..J
0 I I /:
0:::: I :::HnG:i:t:
F I 28.5' .... 38.76'
<( ~ RESDENCE IS ON OR NEAR PROPERTY UNE
W 0- ......
:z: I- 3' WALK @5 <<>-
-' "- w Vl
0:::: <( u!1 I 26.5' '" -O<:::E~
0 :r: U"l ffi~"'i5
0- m
(j) _~I I S....,:::I:fB
CO <( 30.5'
--.J b ...JVlfEo::::
W U"ll I ~ 38.76'
::c:: RESDENCE IS ON OR NEAR PROPERTY UNE
IJ) "- 30.0
R.D.E.
W
81 >
II -
0::::
0
I W
~ ~ :1 I-
<:( ;;t;
I C)
I .,;
-1 a;
:z:
w
~, 0 I-
:z
--.J w
0 :::;;
w
(j)
C) <(
w
(j)
(j)
w
""
'-"
~
(j)
(j)
w
""
'-"
~
.
<(
.
'"
U
0
-'
CD
REVISION #1
CHANGED LOT NUMBERS
12/08/04 AMA
Note:
Per Cannel zoning ordinance 26.1.1 :
The residential district limits height to twenty-five
feet (25'), however a dwelling may be inaeased in height
to thirty-five feet (35') pro,;ded the side and rear }Ords
ore inaeosed on additional one foot (1') for each
one foot (1') the structure exceeds the first
twenty-five feel (25') in height.