Loading...
HomeMy WebLinkAbout04120062 Signed Conditional PERMIT PLAN REVIEW STOPS PAGE 11 , PERMIT NUMBER: 04120062 - MARTIN CURDES PARCEL ID : 1610290107015000 PARCEL ADDRS : 120 FIRST CT CARMEL. IN 46033 APPLY DATE 12/10/04 ISSUE DATE C/O DATE CONTRACTOR : FOERSTER CONSTRUCTION . PHONE NUNBER.: (317) a.J4 718i:~'1{'-2~?J FAX NUMBER : 317..1174rJ1'" ______________________________________________________________________~J~~~~J REVIEW STOP: BLDG - BUILDING INSPECTOR REVIEW REV NO: 1 STATUS: C DATE: 12/15/04 CONT 10: REVIEW SENT BY: aschrine DATE: 12/15/04 TIME: 13:19 TIME SPENT: REV RECEIVD BY: aschrine DATE: 12/13/04 TIME: 08:34 SENT TO: REVIEW NOTES: 2004-12-15 13:22:05 Conditions of Permit: Smoke detectors must be brouaht to current code throughout entire house (see handout). Signature: TYPE: I RESREMODEL I I 0:00 I , I CONDITIONAL .tw RELEASED FOR CONSTRUCTI~N SubjeCt to compliance with all regulations ot State 2.nd Local Codes. DEPT OF COMMUNITY SERVICES CITY OF CARMEL / CLAY TOWNSHIP l~mIANA ENCOMPASS - Pentamation permit.4ge (permit5.4g1) RUN DATE:12/15/04 Smoke Alarms IRe Section 317 . R317.1 Labeling. Each smoke alarm shall be listed. i R317.Z Required smoke alarms locations. At least one (I) smoke alarm shall be installed in each of the following locations: (a) In the living area remote from the kitchen and cooking appliances. Smoke alarms located within twenty (20) feet horizontally of a cooking appliance must incorporate a temporal)' silencing feature or be photoelectric type. (b) In each room designed for sleeping. (e) On the ceiling of the upper level near the top or above each stairway, other than a basement stairway, in any multistory dwelling. The alam1 shall be located so that smoke rising in the stairway call1lot be prevented from reaching the alarm by an intervening door or obstruction. (d) In the basement near the stairway. R317.2.1 Alterations and additions. 'Vhen interior alterations or additions requiring a permit occur, or when oue or more sleepiug rooms are added or created in existing dwellings, the iudividual dwelling unit shall be provided with smoke alarms located as required for new dwelliugs; the smoke alarms shall be interconnected and hard wired. EXCEPTIONS: 1. Smoke alarms in existing areas shall not be required to meet the requirements of R317.5 where the alterations do not result in the removal of the interior wall or ceiling finishes exposing the structure unless there is an attic, crawl space, or basement available which could provide access for hard wiriug and interconnection without the removal of interior finishes. 2. Repairs are exempt from the requirements of the section. R317.3 Prohibited smoke alarm locations. A smoke alarm required under this section shall not be placed; 1. within three (3) feet horizontally from any grill moving conditioned air within the living space; or 2. in any location or environment that is prohibited by the terms of the listing. R317.4 Mounting requirements. Smoke alarms required by Section R317.2 shall be mounted in accordance with their listing, instructions, and the requirements of this section. R317.4.1 Flat CejJjngs. In rooms with flat, peaked sloping or single slope ceiling with a slope ofless than 1.5/12, smoke alarms shall be mounted either: 1. on the ceiling at least four (4) inches from each wall; or , 2. on a wall with the top of the alarm not less than foW" (4) inches below the ceiling and not farther from the ceiling than twelve (12) inches or the distance from the ceiling specified in the smoke alarm manufacturer's listing and instructions whichever is less. R3l7.4..Z Peaked Sloping Ceilings. in rooms with peaked sloping ceiling with a slope of 1.5/12 or greater, smoke alarms shall be: 1. mounted on the ceiling or wall within three (3) feet measured horizontally, from the peak of the ceiling; 2. not closer than four (4) inches from any adjoining wall surfaces or any projection structural element. R317.4.4 Visible and tactile notification appliances. In addition to the smoke alarms required pursuant to this section, listed visible and tactile notification appliances, when installed, shall meet the following: R3l7.4.4.l Candela Rated-Sleeping Room. A visible notification appliance, when installed in a room designed for sleeping shall have a minimum rating of one hundred seventy-seven (177) candela, except that when the visible notification appliance is wall- mounted or suspended more than twenty-four (24) inches below the ceiling, a minimum rating of one hundred ten (110) candela is pemutted. R317.4.4.2 Candela Rated-Non-Sleeping Room. A visible notification appliance, when installed in an area other than a room designed for sleeping, shall have a minimum rating of fifteen (I 5) candela. R31 7.5 Connection to Power Source. Each smoke alarm shall be powered from: 1. the electrical system of the home as the primary power source and a battery as a secondary as power source; or 2. a battery rated for ten-(10) year life, provided the smoke alarm is listed for use with a ten - (10) year battery. EXCEPTION: Visible and tactile notification appliances are requiTed to operate from the primary power source, but are not required to operate from a secondary power source. R317.5.1 Circuitry. Each smoke alarm whose primary power source is the home electrical system shall be mounted on an elecn'ical box and be cormected by a permanent wiring method to a general branch circuit. The same branch circuit may serve more than one smoke alalm. The branch circuit for the alarm shall not include any switches between the circuit over cunent protective device and the alarm, and shall not be protected by a ground-fault-circuit interrupter. R317.5.2 Interconnection. When more than one smoke alarm is required to be installed within an individual dwelling unit the alarm devices shall be intercoilllected in such a mamler that the actuation of one alarm will activate all of the alarms in the individual unit. (675 lAC 14-4.2-3 I) Effective March 24, 2004