HomeMy WebLinkAboutSG_Life Safety Plan_2024-04-30_sg Carmel IN CD Delivery SetDISTANCE BETWEEN EXITS = 36' -6" MIN DISTANCE BETWEEN EXITS REQUIRED = 27' -8" DIAGONAL DISTANCE = 83' -1" 1/3 DIAGONAL DISTANCE = 27' -8" COOLER DINING KITCHEN PATIO REST/CIRC MIN. CLEAR44"MIN. CLEAR44"84 1,256 SF DINING 122 SF COOLER 192 SF REST/CIRC 5 944 SF KITCHEN 7 1 3 5 2 6 10 8 9 4 1 2 10 10 4 6 6 7 3 10 95 SF PATIO MAXIMUM PATH OF EGRESS TRAVEL:81'-5"MAXIMUM LENGTH ALLOWABLE: 250'-0"10 #OCCUPANCY LOAD PATH OF TRAVEL X TYPE OF OCCUPANCY: OCCUPANCY SEPARATION: TYPE OF CONSTRUCTION: AREA (TENANT ONLY): AREA & HEIGHT MODIFICATIONS: ACCESSIBLE SEATING (5% OF TOTAL) DINING: PATIO: DINING PATIO TOTAL SEATS PROVIDED: SEAT COUNTS/ ACCESSIBLE SEATING REQUIREMENTS: 3 REQUIRED 1 REQUIRED 76 3 PROVIDED 1 PROVIDED 58 18 EGRESS & FIRE SAFETY REQUIREMENTS: FIRE SPRINKLERS: NUMBER OF EXITS REQUIRED: NUMBER OF EXITS PROVIDED: MINIMUM DISTANCE BETWEEN EXITS REQUIRED: DISTANCE BETWEEN EXITS PROVIDED: MAXIMUM TRAVEL DISTANCE TO EXIT ALLOWED: TRAVEL DISTANCE TO EXIT PROVIDED: MAXIMUM DEAD-END CORRIDOR ALLOWED: MAXIMUM DEAD-END CORRIDOR DESIGNED: A-2 1 HOUR III-B 2504 SF NONE PROPOSED 2 2 OCCUPANCY & USE DATA: 27' -8" 36' -6" 20' -0" 0" Yes 250' -0" 81' -5" FIXTURE WATER CLOSET REQ'D PROVIDE REQ'D PROVIDE NOT REQUIRED N/A LAVATORIES URINALS DRINKING FOUNTAIN NOT REQUIRED N/A 1 1 MEN: (59)WOMEN: (59) 1 1 1 TOTAL PLUMBING OCCUPANTS: 118 0 1 1 0 1 THESE DRAWINGS & SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF SWEETGREEN CORPORATION. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF SWEETGREEN CORPORATION. THESE DRAWINGS & SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL SWEETGREEN STORE (WHICH IS SUBJECT TO CHANGE AT ANY TIME) AND MAY NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT AS STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED. PROJECT NO: DRAWN BY: CHECKED BY: PROJECT MANAGER: 3102 W. 36TH STREET LOS ANGELES, CALIFORNIA 90018 ARCHITECT OF RECORD:PROJECT INFORMATION:SG DESIGN MANAGER: SG CONSTR. MANAGER: STAMP:PROJECT INFORMATION:REVISIONS REV. DATE DESCRIPTION TEMPLATE VERSION: 05.20.2022.01 CD DELIVERY SET TO SWEETGREEN SG DM CHECKED BY:4/30/2024 12:45:53 PM120123 LIFE SAFETY PLAN G-20014400 CLAY TERRACE BLVD.TENANT BAY #D01CARMELET ST 04/30/2024 AS AL ST CARMEL, IN 46032AS A. REFER TO DOOR & HARDWARE SCHEDULE FOR ACCESSIBLE EGRESS DOOR AND HARDWARE REQUIREMENTS. B. LANDLORD TO PROVIDE CONTINUATION OF ACCESSIBLE EGRESS ROUTE OF TRAVEL BEYOND LEASE LINE. C. ACCESSIBLE ROUTE OF TRAVEL NOT TO EXCEED RUNNING SLOPE OF 1:20, MAX. CROSS SLOPE OF 1:50. NOTIFY ARCHITECT OF NON-COMPLIANCE. D. DURING CONSTRUCTION, AT LEAST ONE FIRE EXTINGUISHER SHALL BE PROVIDED ON EACH FLOOR LEVEL AT EACH STAIRWAY, IN ALL STORAGE AND CONSTRUCTION SHEDS, IN LOCATIONS WHERE FLAMMABLE OR COMBUSTIBLE LIQUIDS ARE STORED OR USED, AND WHERE OTHER SPECIAL HAZARDS ARE PRESENT. E. EXITS, EXIT SIGNS, FIRE ALARM PANELS, HOSE CABINETS, FIRE EXTINGUISHER LOCATIONS, AND STANDPIPE CONNECTIONS SHALL NOT BE CONCEALED BY CURTAINS, MIRRORS, OR OTHER DECORATIVE MATERIAL. F. ELECTRICAL CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF A ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING EQUIPMENT SHALL BE LOCATED WITHIN ALLOWABLE REACH RANGES. LOW REACH SHALL BE MEASURED TO BE BOTTOM OF THE OUTLET BOX AND HIGH REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. G. ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED WITHIN ALLOWABLE REACH RANGES. LOW REACH SHALL BE MEASURED TO BE BOTTOM OF THE OUTLET BOX AND HIGH REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. H. REFER TO ACCESSIBILITY SHEETS FOR ADDITIONAL DETAILS AND REQUIREMENTS FOR ACCESSIBLE FEATURES. 1 EXIT PATH OF TRAVEL, 44" MIN 2 ILLUMINATED EXIT SIGNAGE, SEE LIGHTING SCHEDULE 3 FIRE EXTINGUISHER. CONFIRM FINAL LOCATIONS AND QUANTITIES WITH LOCAL FIRE JURISDICTION. 4 PROVIDE SIGN ABOVE DOOR: "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED"; SEE SIGNAGE SCHEDULE 5 MAXIMUM OCCUPANCY SIGNAGE, SEE SIGNAGE SCHEDULE 6 36" CLEARANCE IN FRONT OF ELECTRICAL PANELS 7 EXISTING DEMISING WALL. REFER TO DEMISED PREMISES PLAN. 8 ACCESSIBLE TRANSACTION COUNTER. MIN. 36" LENGTH AT 34" AFF. CLEAR FLOOR SPACE IN FRONT OF COUNTER TO BE MIN. 30"x 48" FOR SIDE APPROACH. 9 ACCESSIBLE BEVERAGE STATION AT 34" AFF 10 ACCESSIBLE SEATING TRUE NORTH PLAN NORTH 1/4" = 1'-0" 1 LIFE SAFETY PLAN GENERAL NOTES CODED NOTES CODE REVIEW LIFE SAFETY LEGEND BUILDING OCCUPANT LOAD ROOM NAME AREA SF / LOAD FACTOR = OCC. LOAD COOLER 122 SF / = 0 DINING 1,256 SF / 15 SF = 84 KITCHEN 944 SF / 200 SF = 5 REST/CIRC 192 SF / = 0 2,514 SF 89 TOTAL OCC. 2,514 SF 89 OCCUPANT LOAD- PLUMBING ROOM NAME AREA SF / LOAD FACTOR = OCC. LOAD COOLER 122 SF / = 0 DINING 1,256 SF / 15 SF = 84 KITCHEN 944 SF / 200 SF = 5 PATIO 414 SF / 15 SF = 29 REST/CIRC 192 SF / = 0 2,928 SF 118