HomeMy WebLinkAboutSG_Life Safety Plan_2024-04-30_sg Carmel IN CD Delivery SetDISTANCE BETWEEN EXITS = 36' -6"
MIN DISTANCE BETWEEN EXITS REQUIRED = 27' -8"
DIAGONAL DISTANCE = 83' -1"
1/3 DIAGONAL DISTANCE = 27' -8"
COOLER
DINING
KITCHEN
PATIO
REST/CIRC
MIN. CLEAR44"MIN. CLEAR44"84
1,256 SF
DINING
122 SF
COOLER
192 SF
REST/CIRC
5
944 SF
KITCHEN
7
1
3
5
2
6
10
8
9
4
1
2
10
10
4
6 6
7
3
10
95 SF
PATIO
MAXIMUM PATH OF EGRESS TRAVEL:81'-5"MAXIMUM LENGTH ALLOWABLE: 250'-0"10
#OCCUPANCY LOAD
PATH OF TRAVEL
X
TYPE OF OCCUPANCY:
OCCUPANCY SEPARATION:
TYPE OF CONSTRUCTION:
AREA (TENANT ONLY):
AREA & HEIGHT MODIFICATIONS:
ACCESSIBLE SEATING (5% OF TOTAL)
DINING:
PATIO:
DINING
PATIO
TOTAL SEATS PROVIDED:
SEAT COUNTS/ ACCESSIBLE SEATING REQUIREMENTS:
3 REQUIRED
1 REQUIRED
76
3 PROVIDED
1 PROVIDED
58
18
EGRESS & FIRE SAFETY REQUIREMENTS:
FIRE SPRINKLERS:
NUMBER OF EXITS REQUIRED:
NUMBER OF EXITS PROVIDED:
MINIMUM DISTANCE BETWEEN EXITS REQUIRED:
DISTANCE BETWEEN EXITS PROVIDED:
MAXIMUM TRAVEL DISTANCE TO EXIT ALLOWED:
TRAVEL DISTANCE TO EXIT PROVIDED:
MAXIMUM DEAD-END CORRIDOR ALLOWED:
MAXIMUM DEAD-END CORRIDOR DESIGNED:
A-2
1 HOUR
III-B
2504 SF
NONE PROPOSED
2
2
OCCUPANCY & USE DATA:
27' -8"
36' -6"
20' -0"
0"
Yes
250' -0"
81' -5"
FIXTURE
WATER CLOSET
REQ'D PROVIDE REQ'D PROVIDE
NOT REQUIRED
N/A
LAVATORIES
URINALS
DRINKING FOUNTAIN NOT REQUIRED
N/A
1
1
MEN: (59)WOMEN: (59)
1
1 1
TOTAL PLUMBING OCCUPANTS: 118
0
1
1
0
1
THESE DRAWINGS & SPECIFICATIONS ARE CONFIDENTIAL
AND SHALL REMAIN THE SOLE PROPERTY OF SWEETGREEN
CORPORATION. THEY SHALL NOT BE REPRODUCED (IN
WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR
USED IN ANY MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR
WRITTEN CONSENT OF SWEETGREEN CORPORATION.
THESE DRAWINGS & SPECIFICATIONS ARE INTENDED TO
EXPRESS DESIGN INTENT FOR A PROTOTYPICAL
SWEETGREEN STORE (WHICH IS SUBJECT TO CHANGE AT
ANY TIME) AND MAY NOT REFLECT ACTUAL SITE
CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION
NOR LIABILITY TO THE OTHER (EXCEPT AS STATED ABOVE)
UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED.
PROJECT NO:
DRAWN BY:
CHECKED BY:
PROJECT MANAGER:
3102 W. 36TH STREET
LOS ANGELES, CALIFORNIA 90018
ARCHITECT OF RECORD:PROJECT INFORMATION:SG DESIGN MANAGER:
SG CONSTR. MANAGER:
STAMP:PROJECT INFORMATION:REVISIONS
REV. DATE DESCRIPTION
TEMPLATE VERSION: 05.20.2022.01
CD DELIVERY
SET TO
SWEETGREEN
SG DM CHECKED BY:4/30/2024 12:45:53 PM120123
LIFE SAFETY PLAN
G-20014400 CLAY TERRACE BLVD.TENANT BAY #D01CARMELET
ST
04/30/2024
AS
AL
ST CARMEL, IN 46032AS
A. REFER TO DOOR & HARDWARE SCHEDULE FOR ACCESSIBLE EGRESS DOOR AND HARDWARE
REQUIREMENTS.
B. LANDLORD TO PROVIDE CONTINUATION OF ACCESSIBLE EGRESS ROUTE OF TRAVEL BEYOND LEASE LINE.
C. ACCESSIBLE ROUTE OF TRAVEL NOT TO EXCEED RUNNING SLOPE OF 1:20, MAX. CROSS SLOPE OF 1:50.
NOTIFY ARCHITECT OF NON-COMPLIANCE.
D. DURING CONSTRUCTION, AT LEAST ONE FIRE EXTINGUISHER SHALL BE PROVIDED ON EACH FLOOR LEVEL AT
EACH STAIRWAY, IN ALL STORAGE AND CONSTRUCTION SHEDS, IN LOCATIONS WHERE FLAMMABLE OR
COMBUSTIBLE LIQUIDS ARE STORED OR USED, AND WHERE OTHER SPECIAL HAZARDS ARE PRESENT.
E. EXITS, EXIT SIGNS, FIRE ALARM PANELS, HOSE CABINETS, FIRE EXTINGUISHER LOCATIONS, AND STANDPIPE
CONNECTIONS SHALL NOT BE CONCEALED BY CURTAINS, MIRRORS, OR OTHER DECORATIVE MATERIAL.
F. ELECTRICAL CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF A ROOM OR AREA TO
CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING
EQUIPMENT SHALL BE LOCATED WITHIN ALLOWABLE REACH RANGES. LOW REACH SHALL BE MEASURED TO
BE BOTTOM OF THE OUTLET BOX AND HIGH REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX.
G. ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION
SYSTEM RECEPTACLES SHALL BE LOCATED WITHIN ALLOWABLE REACH RANGES. LOW REACH SHALL BE
MEASURED TO BE BOTTOM OF THE OUTLET BOX AND HIGH REACH SHALL BE MEASURED TO THE TOP OF THE
OUTLET BOX.
H. REFER TO ACCESSIBILITY SHEETS FOR ADDITIONAL DETAILS AND REQUIREMENTS FOR ACCESSIBLE
FEATURES.
1 EXIT PATH OF TRAVEL, 44" MIN
2 ILLUMINATED EXIT SIGNAGE, SEE LIGHTING SCHEDULE
3 FIRE EXTINGUISHER. CONFIRM FINAL LOCATIONS AND QUANTITIES WITH LOCAL FIRE JURISDICTION.
4 PROVIDE SIGN ABOVE DOOR: "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED"; SEE
SIGNAGE SCHEDULE
5 MAXIMUM OCCUPANCY SIGNAGE, SEE SIGNAGE SCHEDULE
6 36" CLEARANCE IN FRONT OF ELECTRICAL PANELS
7 EXISTING DEMISING WALL. REFER TO DEMISED PREMISES PLAN.
8 ACCESSIBLE TRANSACTION COUNTER. MIN. 36" LENGTH AT 34" AFF. CLEAR FLOOR SPACE IN FRONT OF
COUNTER TO BE MIN. 30"x 48" FOR SIDE APPROACH.
9 ACCESSIBLE BEVERAGE STATION AT 34" AFF
10 ACCESSIBLE SEATING
TRUE
NORTH
PLAN
NORTH
1/4" = 1'-0"
1 LIFE SAFETY PLAN
GENERAL NOTES CODED NOTES CODE REVIEW LIFE SAFETY LEGEND
BUILDING OCCUPANT LOAD
ROOM NAME AREA SF /
LOAD
FACTOR =
OCC.
LOAD
COOLER 122 SF / = 0
DINING 1,256 SF / 15 SF = 84
KITCHEN 944 SF / 200 SF = 5
REST/CIRC 192 SF / = 0
2,514 SF 89
TOTAL OCC. 2,514 SF 89
OCCUPANT LOAD- PLUMBING
ROOM NAME AREA SF /
LOAD
FACTOR =
OCC.
LOAD
COOLER 122 SF / = 0
DINING 1,256 SF / 15 SF = 84
KITCHEN 944 SF / 200 SF = 5
PATIO 414 SF / 15 SF = 29
REST/CIRC 192 SF / = 0
2,928 SF 118