Loading...
HomeMy WebLinkAbout07030157 Site Plan ~., Schneider Note: ThIs drawing Is based on construction plans or record drawings, ond is not bosed upon 0 fi~d survey. Th. Schn~der Corporation does not worrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. My discrepancy found on this drawing should b. reported to Th. Schn.ider Ccrporatlon hnmedlat~y. faUlng to do so resuits In the controctors assumption of ~i lIabUity. Piot Pion Legend Not. ~ Proposed Grades The basement e1eYCIUon, depicted hereon. has been determliled and basecl 000.0 Existing Grades on the pod !/'OdeS and/or contours taken from tho con.struction plan. for -000.0--- Contour Grade this subdMslon. Unless stated, no information about ~uctuatlng woter * Approx. lateral location tabla. soB conditions, or soD twes has been provided or stated on said _ . _ Sanitary Sewer Unes plans. this lot Is located near a body of water. Lot or 801: condItions may _ ,,_ Storm Sewer Unes require that the basement floor elevation be held 2 foot obOYll normal pool _ \I _ Water SenicI _ Unes e1ewrtlon. Site lnY8lltlgatlon moy be needed If water Is encountered during _ _ _ _ _ _ _ Sub-SUrface Drain Unes the IXCO'I'Utlon process or If other known water e1eYCItlon or soDs . M h I (So It St) condiUon. ore present In...UgoUon and any rsmodid procedures is ot th. . 8 a~lo e I I t" (~? or) ann dfteretIon of the buDder to determine and take appropriate step8 of action. e 'Ie n e arm If any ground water is enCCltJntered during exCQVOtion the buDder Is IlIII CUrb Inl.t (Storm) encouraged to contoct Th. Schn~d.. Corporotlon to discuss poosibl. D End Section (Storm) c""... of octlon. NOlE: ... Flre Hydrant - . .. - . . . - Flow LIn. of swal. LOT # 6 SUMP PUMP(S) TO BE PLACED BY BUILOER AS NEEDEO. VB # 07.0069332 The ScImoldor CorporoUoa 8iOI ou. AlOllUll IIIItorlc Fort _ ""fin'.p"'H" lndI.ana 46215-1037 317-626-7100 317-626-7200 FAI IacIDeor!D( SumJ!Ila IAndIoapo - GIlI.Ull GooIoc1 I I I I I I I 1--------- I 15' D.U.&S.E This Plot Plan Prepared For: Arbor Homes Lot # 6 ,containing 12.599 S.F.:I:, in The Trails at Hoyden Run Sec. 1 INSTR. # 200500069468 Cloy Twp, Hamilton County Sec 20, T29N, R3E 14230 BRANOT LANE Westfield, IN 46074 Prepared Dote: 03/06/07: By: KAG (50'R/W) CommunIty Restrictions: Sid. Yard -J' min. R.ar Yard _ N/A Aggregate _ 6 (B.H.) ARBOR HOMES Pad Grade = 920.2 per plan Pad Grad. + 1.0' = Garag. FFE (921.2) Garage FFE + 0.5' = Residential FfE (921.7 ) Residential FFE - 10.0' = Basement FFE (911.7 Driveway Slope = 4.1" Note: The garage finished fioor elevation Is 1.6' above the curb at the drive, per plan. GROUND COVER CALCULATIONS: Drive = 921 SF:!: Public Walk =370 SF:!: Prl",te Walk = 77 SF:!: Seeding = 2,918SF:!: Sod = 6 401 SF:!: , even with the rear of house. 64.1 "0 o c:i O'l w ~ w ..( ::li ...J 1Q I PER PLAN Note: Sanitary Sewer Top of Costing Information Upstream Manhole, TC= 920.88 Downstream Manhole, Te= 920.02 PER RECORD DRA\\1NG. D.toU of t)l>lc~ Storm Water. flow pattern for lnd'lViduollots. o ~ =~= [J1] =W= - --- Note: The contractor Is to malntoin 0 mlnhnum distance of ten foot (10') between the sanltry sewer ond water line laterals. o Assumed North Scale: l' . 30' ~.H.1806 TC-920.B8 PER RECORO ORAllUlG Note: Bunder to ensure posItive drainage away from .tructure(s). III :> I " 140.00' :> 30.0' B-B 52 20.33 >- w '" 16' II w I en ...J1lr!!!/~ · cD ~l!;~ "'NI 0 ~ 1<l 29.3 39.3' . - ~ .. In I I I :> I I I I I I I :> ~ ~ "" hi ;j~~ 15~1.6 ~~ 10 ~ I ~ Ii l ~ 5.0' z: PER PlAN <( I ~ ! I OJ IO::i! I -: ~ '~~ti 11 ~ I :> ~ '" ~ I 7.00' :!: 26. III " 16.3'16.0' I 140.00' ......"a.... ~.H.f605 TC=92D.02 PER RfCOOD ORA\\lNG FLOOD HAZARD STATEMENT CERn FICA nON ~\I\I\I\\\\IIII"I/{""II/, ~~\'\ L I'ij~ ~ "S 'c/' '0, ~~~"\ ............... /f' c0-ft;, ~ .{G\S Telfe.... "'A~ ~~ ..,~ No - ().... ;<>~ I ( S0303 ..'j , ~ . . - % ..... STATE OF..... ~ ~ <";';>Ilvol A~\;"~~# %'2!:f "'S'UR'~\~ flll/(/(IJIJIII\\I\I\\II\~ ~l'fi1 Note: Per Ccrm~ zoning ordinance 26.1.1 : Th. resldentl~ ~ district ihnits h.ight to twenty-five foot (25'), however . ;. a dw.lllng may b. Increased in height to thlrty-flve foot (35') pro~ded tho sid. and roar )'lI'ds are Increased ""ICAl SWAlE SECTION an additional one foat (1') for oech one roat (1') the structure "coeds tho first twenty-five feet (25') In height This drawing is not intended to be represented as a retracement or original boundary survey, a route survey, or a Surveyor Location Report. Flood Hazard Statsment The accuracy of any flood hazcrd dato shown on th~ report is subject to map. scale uncertainty <lid to CIly other uncertoi1ty i1 location or elevation on the referenced ftood InSUllllCO rate map. All. of the with" doscr1bod land DO€S NOT UE within that spocIaI flood hazard zone A as said land plots by scaI. on flood Insurance rate map , 18057C0205f for City of Ccrm~, Indlona (maps dated FebnlCry 19, 2003).