HomeMy WebLinkAboutC0.0.TSSITE
ROBEY SURGERY CENTER & CLINIC
SE CORNER OF HARLESTON ST & PETTIGRU DR
CIVIL CONSTRUCTION PLANS
PROJECT DEVELOPER:
CARMEL, INDIANA 46033
C0.0
VICINITY MAP
SHEET OF
PROJECT NUMBER
DRAWING NUMBER
ACG.065
PROJECT VICINITY
05/15/2024
ZXV INVESTMENTS, LLC
Dr. Ashley Robey
Email: robey@robeyplasticsurgery.com
Docket No: PZ-2024-00086
CONSTRUCTION PLAN INDEX
LAND DESCRIPTION
A PART OF THE SOUTHEAST QUARTER OF SECTION 29, TOWNSHIP 18 NORTH, RANGE 3 EAST, CLAY TOWNSHIP, HAMILTON
COUNTY, INDIANA, BEING MORE PARTICULARLY DESCRIBED AS BELOW:
A PART OF BLOCK “B” IN THE VILLAGE OF WESTCLAY, SECTION 6003-B, RECORDED AS INSTRUMENT NUMBER 2007013950
AND FILED IN PLAT CABINET 4, SLIDE 264 IN THE OFFICE OF THE RECORDER OF HAMILTON COUNTY, INDIANA, LOCATED IN
THE SOUTHEAST QUARTER SECTION 29, TOWNSHIP 18 NORTH, RANGE 3 EAST IN CLAY TOWNSHIP, HAMILTON COUNTY,
INDIANA AND MORE PARTICULARLY DESCRIBED AS FOLLOWS:
COMMENCING AT THE NORTHEAST CORNER OF SAID QUARTER SECTION; THENCE SOUTH 0 DEGREES 12 MINUTES 27
SECONDS WEST, 767.43 FEET; THENCE NORTH 89 DEGREES 48 MINUTES 43 SECONDS WEST, 84.87 FEET TO A CAPPED
REBAR MARKED MAJOR ENGINEERING; THENCE NORTH 89 DEGREES 48 MINUTES 43 SECONDS WEST, 411.47 FEET TO AN
UNCAPPED REBAR AND THE POINT OF BEGINNING OF THIS DESCIPTION; THENCE NORTH 0 DEGREES 12 MINUTES 41
SECONDS EAST, 190.00 FEET TO A CAPPED REBAR MARKED BORDENET 20100044; THENCE NORTH 89 DEGREES 49
MINUTES 51 SECONDS WEST, 94.84 FEET TO A CAPPED REBAR MARKED SCHNEIDER AND THE BEGINNING OF A
CURVE; THENCE 23.90 FEET ALONG SAID CURVE WITH A RADIUS OF 25.00 FEET AND BEING SUBTENDED BY A CHORD
BEARING SOUTH 62 DEGREES 53 MINUTES 30 SECONDS WEST AND BEING 23.00 FEET IN LENGTH TO A CAPPED REBAR
MARKED SCHNEIDER AND THE BEGINNING OF A CURVE; THENCE 34.32 FEET ALONG SAID CURVE WITH A RADIUS OF 100.00
FEEET AND BEING SUBTENDED BY A CHORD BEARING SOUTH 45 DEGREES 24 MINUTES 23 SECONDS WEST AND BEING
34.15 FEET IN LENGTH TO A CAPPED REBAR MARKED SCHNEIDER AND THE BEGINNING OF A CURVE; THENCE 23.92 FEET
ALONG SAID CURVE WITH A RADIUS OF 25.00 FEET AND BEING SUBTENDED BY A CHORD BEARING SOUTH 27 DEGREES 26
MINUTES 31 SECONDS WEST AND BEING 23.02 FEET IN LENGTH TO A CAPPED REBAR MARKED SCHNEIDER; THENCE
SOUTH 0 DEGREES 12 MINUTES 35 SECONDS WEST, 304.06 FEET TO A CAPPED REBAR MARKED MAJOR ENGINEERING;
THENCE NORTH 89 DEGREES 47 MINUTES 48 SECONDS WEST, 150.03 FEET TO A CAPPED REBAR MARKED MAJOR
ENGINEERING; THENCE NORTH 0 DEGREES 12 MINUTES 41 SECONDS EAST, 169.20 FEET TO AN UNCAPPED REBAR AND
THE POINT OF BEGINNING; CONTAINING 52,824 SQUARE FEET, 1.21 ACRES MORE OR LESS.PROF
E
SS
ION A L E NG INEERIND
IA NA
PE10910647
STATE OF
-oNREGIS TER
E
DBR IA N S CR
O
SSDEVELOPMENT SUMMARY
PROPOSED USE: MEDICAL CLINIC / OFFICES
TOTAL SITE AREA = 1.21± Ac.
TOTAL DISTURBED AREA = XXXXX± SF = X.X± Ac
PROPOSED TOTAL BUILDING COVERAGE RATIO = XX% OF SITE AREA
PROPOSED IMPERVIOUS AREA SITE INCREASE = XXXXX± S.F.
CURRENT ZONING = WEST CLAY VILLAGE PUD
SETBACK DISTANCES (PROPOSED) BUILDING SETBACK DISTANCES (REQ'D)
FRONT = 15.7' (Harleston); 16.7' (Pettigru) FRONT = 10' (MIN.)
REAR = 226'± (South PL) REAR = 10' (MIN.)
SIDE = 11.5' (CANOPY OVERHANG) SIDE = 10' (MIN.)
ANTICIPATED CONSTRUCTION START/COMPLETION DATE
JULYT, 2024 / JULY, 2025
TOTAL PARKING SPACES = 67 (INCLUDES STREET PARKING SPACES)
EXISTING RIGHT-OF-WAY NOTE
DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE
SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR
IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START
OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY.
OPERATING AUTHORITY
CITY OF CARMEL DEPT. OF ENGINEERING
ONE CIVIC SQUARE
CARMEL, INDIANA 46032
PHONE: 317-571-2441 FAX: 317-571-2439
CARMEL ENGINEERING DEPT. NOTE
ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE
REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE
DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE
DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED
INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE
DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY.
BENCHMARK
REVISION RECORD
Carmel, Indiana 46032
Ph: (317) 810-1677 Fax: (317) 810-1679
718 Adams Street, Ste E
ENGINEER:
GROUP, INC
SURVEYOR:
Zionsville, Indiana 46077
Contact: Brady Kuhn, PLS
P.O. Box 70
Email: brady@kgsurveying.com
Ph: (317) 654-8829
Natural Gas:
Vectren Energy
Chad Miller
1 (800) 990-1930 (new service)
chad.r.miller@centerpointenergy.com
Sanitary Sewer:
TriCo Regional Sewer Utility
Ryan Hartman
10701 N. College Avenue, Ste. A
Indianapolis, IN 46280
(317) 660-6604
Drainage:
Carmel Engineering
Alex Jordan or John Thomas
1 Civic Square
Carmel, IN 46032
(317) 571-2441
ajordan@carmel.in.gov
Telephone:
AT&T
Wendy Noble
(317) 403-6673
wendy.noble@att.com
Fire Service:
Office of Fire Chief, Fire Station #1
Chris Ellison
10701 N College Ave.
Carmel, IN 46032
(317) 571-2600
cellison@carmel.in.gov
Streets:
Carmel Street Department
Ryan Murt
3400 West 131st Street
Carmel, IN 46074
(317) 733-2014
CATV:
Brighthouse Networks
Jason Kirkman
(317)632-9077 x291
jason.kirkman@mybrighthouse.com
Water:
Carmel City Utilities
John Duffy
30 W Main Street, Ste 220
Carmel, IN 46032
(317) 571-2443
Electric:
Duke Energy
Travis Krick
16475 Southpark Street
Westfield, IN 46074
(317) 385-1225
UTILITY CONTACTS