Loading...
HomeMy WebLinkAboutC2.0.SPPROPOSED BUILDING 22,440 SF ±10' B.S.L.10' B.S.L.6' PARKING LOT SETBACK6' PARKING LOT SETBACK 54 ON-SITE SPACES 13 STREET SPACES 13 14 6 4 13 R/WR/WR/W 10' B.S.L.10' B.S.L.10' B.S.L. 26'± 25' HARLESTON STREET PETIGRU STREET27.2' 10'43.5' Canopy Above12' 21.7'9'9'5' D.U.&S.E.5' D.U.&S.E.3 20'± 3 9' 20'±10' B.S.L. BR DB NO PARKINGPICK-UPACEHARD WARE OUTD O OR GARDEN CENTER S 00°12'35" W 304.07'N 89°49'51" W 94.84' L=23.90', R=25.00' L=34.32', R=100.00' L=23.92', R=25.00' S 89°47'48" E 150.03'N 00°12'41" E 169.20'N 00°12'41" E 190.00'N 89°48'43" W 411.47'9'9'9'5'18'24'36'24' 18'9'24'20'20'6.5' 7.8' 11.4' 24'18'36'24'18'26.3'12' 21.7' R2' R8' R3' R5' R3'9' R3' R1 5 '5' D.U.&S.E.1.9' CANOPY CB CB CB CB CB T T FL DW FL SC RR SC D SS SS AAA1 A1 TT A A A A A A A A A SC TR 3.4' RC RC RC RC RC RC RC A2 A2 C C C C C C C C C C A1 A1 RC A2 A2 DC A A DC DC DC DC DC DC A2 A2 A1 A1 TT TT A1 D D D D D D D D D D D D D SW SW D D D D D D DD D6 D6 D D D GN 5' 7.8' 7' T SC SC SC SC SC FL DW DW FL DW FL FLT DW FL 3.5' R6' 5' A T 8' D6 D6DB 5'20'20 ' 9.5'18'GS10' B.S.L.10' B.S.L.R20' R20' R5' DA DA 15' TYP.5'TYP.18.9' 25'15'30'15'1 6 . 5 ' 5.5'15'CANOPY CB CB 11.5' DB 6' 8'8'8'19.6' DB SCCB 5' 14 A A R3.5' R3.5' R3.5' R3.5' R3.5' R3.5' R3.5' R5' R3.5' 05/15/2024 TOPOGRAPHIC & BOUNDARY NOTE ENGINEER: ARCHITECT: SURVEYOR:SITE LAYOUT NOTES PLAN NOTES: LEGEND: PLAN NOTES: A C D FL DW B6 CB G F T TR D6 NOTE REFER TO ARCHITECTURAL & FOUNDATION PLANS FOR ALL BUILDING DIMENSIONS. DB SW SS PROJECT NUMBER DRAWING NUMBER SHEET OF SCALE: DATE: DWN BY: CHKD. BY:CIVIL SITE GROUP, INC.GROUP, INC.PROF E SS ION A L E NG INEERIND IA NA PE10910647 STATE OF -oNREGIS TER E DBR IA N S CR O SSACG.065 C2.0INDIANAPOLIS, INDIANA 46225425 W SOUTH STREET, STE 100ALDERSON COMMERCIAL GROUP, INC.SITE PLANROBEY SURGERY CENTER & CLINICSE CORNER OF HARLESTON ST & PETTIGRU DRCARMEL, IN 46033PRELI MI NARY NOT F O R C ONST R U CTI O N GS GN DEVELOPMENT SUMMARY PROPOSED BUILDING G.S.F. = 22,440± LOT AREA = 1.21± Ac ZONING: PUD - VILLAGE OF WEST CLAY PARKING SPACES PROVIDED = 67 PARKING SPACES REQ'D. = 1 SPACE/500 GSF = 45 REQ'D ANTICIPATED CONSTRUCTION START/END DATE: JULY, 2024 / JULY, 2025 REVISION RECORD EXISTING CONDITIONS NOTE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, INCLUDING UTILITIES AND DRAINAGE INFRASTRUCTURE BEFORE COMMENCING WITH CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES. R/W RESTORATION NOTE ALL ROADS & R/W MUST BE BROUGHT BACK TO ORIGINAL OR BETTER CONDITION. REPAIRS (i.e. STRIPING, CURB, GRADING, SEEDING, & SIGNAGE) SHALL COINCIDE WITH THE ADJOINING ROAD. PAVING WITHIN CITY R/W NOTE ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY. IF IT WILL BE NECESSARY TO RELOCATE EXISTING UTILITIES, THE EXPENSE OF SUCH RELOCATION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. ALL UTILITY POLES SHALL BE LOCATED WITHIN ONE-FOOT OF THE PROPOSED RIGHT-OF-WAY. SIDEWALK NOTE ALL SIDEWALKS CONSTRUCTED WITHIN THE PUBLIC RIGHT-OF-WAY SHALL COMPLY WITH STANDARD CITY OF CARMEL AND/OR INDOT DETAILS. ALL PROPERTY CORNER MONUMENTS SHOULD BE MARKED PRIOR TO COMMENCING WITH CONSTRUCTION AND PROTECTED DURING ALL CONSTRUCTION ACTIVITY. PROPERTY CORNER MONUMENTS NOTE BR D A1 A2 RC DC RR A2 DA DA CITY OF CARMEL STANDARDS CONTRACTOR TO CONSTRUCT ALL APPLICABLE SITE IMPROVEMENTS WITHIN THE PUBLIC RIGHT-OF-WAY TO THE CITY OF CARMEL CURRENT STANDARDS AND SPECIFICATIONS. CURB SAWCUT NOTE EXISTING CURBS TO BE SAWCUT, PROPOSED CURBS SHALL BE DOWELED INTO EXISTING CURB IN COORDINATION WITH REQUIREMENTS OF THE CITY OF CARMEL DEPARTMENT OF ENGINEEING - 317-571-2441 VILLAGE OF WEST CLAY NOTES EXISTING TREE, STREET LIGHTING, ELECTRICAL, AND IRRIGATION SYSTEMS TO BE PROTECTED AND OR RESTORED TO PROCONSTRUCTION CONDITIONS TO THE ACCEPTANCE OF THE VILLAGE OF WESTCLAY OWNERS ASSOCIATION. BUILDER TO CONTACT WESTCLAY OA (317-574-1164) TO COORDINATE FLAGGING OF THE WESTCLAY PRIVATE UTILITIES. BUILDER WILL BE RESPONSIBLE FOR DAMAGES TO STREET LIGHT WIRING AND PROJECT IRRIGATION SYSTEM CAUSED BY CONTRACTORS. PLEASE CALL 48 HOURS PRIOR TO START OF CONSTRUCTION TO ASSURE LOCATES ARE COMPLETED PRIOR TO EXCAVATION. SANITARY SEWER SERVICE CONNECTION TO BE COORDINATED WITH AND PERMITTED THROUGH THE CITY OF CARMEL DEPARTMENT OF ENGINEERING AND TRICO REGIONAL REGIONAL WASTE DISTRICT. BUILDER SHALL NOT ALTER ELEVATION OF DRAINAGE SWALES, INLETS, FIRE HYDRANTS, WATER VALVES, MANHOLES, CURBS OR ASPHALT WITHOUT PRIOR APPROVAL FROM THE CITY OF CARMEL. BUILDER AND LOT OWNER SHALL ASSUME ALL LIABILITY ASSOCIATED WITH REQUIRED MINIMUM FLOOD PROTECTION GRADES AND MINIMUM LOWEST ADJACENT GRADES. ALL MUD IN STREETS AND OR ADJACENT PARKING AREAS FROM TRUCKS LEAVING LOT TO BE CLEANED AT THE END OF EACH WORK DAY. DECLARANT RESERVES THE RIGHT FOR ITSELF AND THE ASSOCIATION TO RECONFIGURE THE COMMON PARKING LOTS FROM TIME TO TIME, WHICH RECONFIGURATION MAY INCREASE OR DECREASE THE NUMBER OF PARKING SPACES AVAILABLE. ALL SITE LIGHTING SHALL CONFORM TO VILLAGE OF WESTCLAY STANDARD CLASSIC STYLE FLUTED POLE WITH ACORN STYLE LUMINAIRE, SEE OTHER SITES FOR COMPARISON. COORDINATE FIXTURE SELECTION AND APPROVAL WITH OWNERS ASSOCIATION PRIOR TO ORDERING & INSTALLING. BUILDER MUST SUPPLY DUMPSTER AND TEMPORARY TOILET FACILITIES AT ALL TIMES DURING CONSTRUCTION