Loading...
HomeMy WebLinkAboutC3.0.GPR/WR/WR/W HARLESTON STREET PETIGRU STREETFFE =906.90±NO PARKINGPICK-UPRF EX. 30" RCPCURB INLET TYPE A TC=906.75 GUT=906.25 INV=902.75 (S-12" RCP)EX. 30" RCPEX. 18" RCP202 5' Ø FIRST DEFENSE HC BMP TC= 908.5± INV=901.51 (E-12" RCP) INV=901.45 (N-15" RCP) INV=901.20 (W-18" RCP) CURB INLET TYPE A TC=907.00 GUT=906.50 INV=902.51 (N-12" RCP) INV=902.00 (W-12" RCP) 201 200 300 301 BMP M.E.CURB INLET TYPE A TC=906.50 GUT=906.00 INV=902.35 (N-12" PVC) INV=902.25 (W-15" RCP) CURB INLET TYPE A TC=906.75 GUT=906.25 INV=902.07 (E-15" RCP) INV=901.97 (S-15" RCP) CURB INLET TYPE M TC=906.55 GUT=906.05 INV=901.95 (N-15" RCP) INV=901.85 (S-15" RCP)M.E.C.O. INV.=903.0± EXISTING STORM MH TC=907.63 INV=901.12 (E-18" RCP) INV=899.92 (N-30" RCP) INV=899.92 (S-36" RCP) EXISTING CURB INLET TC=904.78 GUT=904.22 INV=900.58 (NW-15" RCP) INV=900.54 (SW-18" RCP) 05/15/2024 TOPOGRAPHIC & BOUNDARY NOTE ENGINEER: ARCHITECT: SURVEYOR: PROJECT NUMBER DRAWING NUMBER SHEET OF SCALE: DATE: DWN BY: CHKD. BY:CIVIL SITE GROUP, INC.GROUP, INC.PROF E SS ION A L E NG INEERIND IA NA PE10910647 STATE OF -oNREGIS TER E DBR IA N S CR O SSACG.065 C3.0INDIANAPOLIS, INDIANA 46225425 W SOUTH STREET, STE 100ALDERSON COMMERCIAL GROUP, INC.GRADING AND DRAINAGE PLANROBEY SURGERY CENTER & CLINICSE CORNER OF HARLESTON ST & PETIGRU DRCARMEL, IN 46033PRELI MI NARY NOT F O R C ONST R U CTI O N REVISION RECORD EXISTING CONDITIONS NOTE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, INCLUDING UTILITIES AND DRAINAGE INFRASTRUCTURE BEFORE COMMENCING WITH CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES. R/W RESTORATION NOTE ALL ROADS & R/W MUST BE BROUGHT BACK TO ORIGINAL OR BETTER CONDITION. REPAIRS (i.e. STRIPING, CURB, GRADING, SEEDING, & SIGNAGE) SHALL COINCIDE WITH THE ADJOINING ROAD. UTILITY LOCATE NOTE UTILITY VALVE NOTE LEGEND: PLAN NOTES: FLOOD NOTE ALL CONCRETE PIPE JOINTS SHALL BE CONTINUOUS O-RING RUBBER GASKET CONFORMING TO ASTM C 443 BENCHMARK ### GRADING NOTES RF NOTE REFER TO ARCHITECTURAL & FOUNDATION PLANS FOR ALL BUILDING DIMENSIONS. CONTRACTOR NOTE NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. GENERAL NOTES CONTRACTOR TO KEEP EXISTING PAVEMENT SURROUNDING THE SITE (I.E. COMMUNITY DRIVE & EQUALITY BLVD.) "BROOM CLEAN" AND FREE OF SOIL OR AGGREGATE THAT MIGHT BE BROUGHT OFF-SITE. DEPENDING ON THE CONSTRUCTION SEASON, MOISTURE CONTENT AND PROPERTIES OF THE SOILS ON SITE, CHEMICAL MODIFICATIONS AND/OR LIME STABILIZATION MAY BE REQUIRED. SEE SHEET C9.0 FOR SPECIFICATIONS. ALL CONCRETE PIPE JOINTS SHALL BE CONTINUOUS O-RING RUBBER GASKET CONFORMING TO ASTM C 443 CONTRACTOR (NOT THE PROJECT SITE OWNER) WILL BE RESPONSIBLE FOR THE DISPOSAL OF ANY SOIL, MATERIALS, ETC. NO OFF-SITE BORROWS OR STOCKPILES WILL BE NEEDED FOR THIS PROJECT. This project is located within The Village of West Clay at the southeast corner of Harleston Street and Pettigru Drive in Hamilton County, Indiana. The subject site is 1.21 +/- acres in size; however, the proposed land disturbance of the project will be 1.44+/- acres, including street parking, walks, and utility services. The entire site generally sheet drains to the perimeter streets via overland flow. Stormwater is collected within the storm sewer system routed to the south then west into existing wet detention ponds discharging into the JM Brendle regulated drain, to Long Branch, to Eagle Creek. The proposed improvements will consist of building a two (2) story 22,400 +/- square foot medical use building. Additional proposed improvements will be adding associated parking, drainage, utility infrastructure, street parking along Pettigru Drive, streetscape improvements, and landscaping. Post Developed release rates: 2yr = 3.63cfs; 10yr = 5.45cfs; 100yr = 7.69cfs DRAINAGE SUMMARY