HomeMy WebLinkAboutC5.0.UPR/WR/WR/W E HARLESTON STREET PETIGRU STREETFV C.O. INV.=901.9± L FFE =906.90± G GAS SERVICE METER W/ BOLLARD PROTECTION PER CENTERPOINT ENERGY STDS.FIELD VERIFY LOCATION/DEPTHOF EXISTING SAN. LATERALNO PARKINGPICK-UP50'50'RF WM PIV FDC 6 3 6 6-INCH WET TAP/VALVE EXISTING MAIN SE ET A A A A A A A A A AA GAS MAIN TO BE RELOCATED BY CENTERPOINT ENERGY T PH EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT 18 18 A EX. SANITRY MH TC=905.86 INV=893.80 (E-8" PVC) INV=893.00 (W-8" PVC) EX. SANITRY MH TC=906.47 INV=898.48 (W-8" PVC)40'40'40'A EX. GAS MAIN TO BE RELOCATED BY CENTERPOINT ENERGY 05/15/2024 TOPOGRAPHIC & BOUNDARY NOTE ENGINEER: ARCHITECT: SURVEYOR: PROJECT NUMBER DRAWING NUMBER SHEET OF SCALE: DATE: DWN BY: CHKD. BY:CIVIL SITE GROUP, INC.GROUP, INC.PROF E SS ION A L E NG INEERIND IA NA PE10910647 STATE OF -oNREGIS TER E DBR IA N S CR O SSACG.065 C5.0INDIANAPOLIS, INDIANA 46225425 W SOUTH STREET, STE 100ALDERSON COMMERCIAL GROUP, INC.UTILITY PLANROBEY SURGERY CENTER & CLINICSE CORNER OF HARLESTON ST & PETIGRU DRCARMEL, IN 46033PRELI MI NARY NOT F O R C ONST R U CTI O N REVISION RECORD EXISTING CONDITIONS NOTE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, INCLUDING UTILITIES AND DRAINAGE INFRASTRUCTURE BEFORE COMMENCING WITH CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES. R/W RESTORATION NOTE ALL ROADS & R/W MUST BE BROUGHT BACK TO ORIGINAL OR BETTER CONDITION. REPAIRS (i.e. STRIPING, CURB, GRADING, SEEDING, & SIGNAGE) SHALL COINCIDE WITH THE ADJOINING ROAD. UTILITY LOCATE NOTE UTILITY VALVE NOTE IRRIGATION NOTE ISDH NOTES THE WATER LINES THROUGHOUT THE PROJECT SHALL BE INSTALLED WITH AT LEAST 60-INCHES OF COVER TO PROVIDE PROTECTION FROM FREEZING. WHERE WATER LINES AND SEWERS (STORM AND/OR SANITARY) CROSS AND THE WATER LINE CANNOT BE PLACED ABOVE/BELOW THE SEWER WITH A MINIMUM OF 18-INCHES VERTICAL CLEARANCE, THE SEWER MUST BE CONSTRUCTED OF WATER WORKS GRADE DUCTILE IRON PIPE WITH MECHANICAL JOINTS OR SDR 26 PVC PRESSURE SEWER PIPE WITH COMPRESSION FITTINGS, & SHALL BE PRESSURE TESTED TO ASSURE WATER TIGHTNESS PRIOR TO BACK-FILLING. SANITARY SEWERS SHOULD HAVE A MINIMUM OF 3 FEET OF COVER. LEGEND: UTILITY NOTES 1. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO THEIR PHASE OF WORK. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATIONS FOR EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. 2. STANDARD SPECIFICATIONS FOR THE LOCAL GOVERNING AGENCY SHALL APPLY FOR ALL SANITARY SEWERS, STORM SEWERS, AND WATER MAINS. 3.ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING UNDER PAVED AREAS TO BE BACKFILLED WITH GRANULAR MATERIAL. 4. ALL WATER MAINS TO HAVE 60" MINIMUM COVER OVER TOP OF PIPE. 5. STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE WITH STATE BOARD OF HEALTH REQUIREMENTS. (APPLIES TO COMMERCIAL ONLY) 6. CONTRACTOR RESPONSIBLE TO INSTALL ALL UNDERGROUND CONDUIT PER UTILITY COMPANY'S SPECIFICATIONS. 7. CONTRACTOR RESPONSIBLE FOR RESTORATION TO ALL AREAS AFFECTED DURING CONSTRUCTION. REFER TO THE TOWN OF FISHERS STANDARDS FOR RESTORATION REQ'S. 8. CONTRACTOR TO LOCATE ALL EXISTING UTILITIES AT ANY PROPOSED CROSSING AND PROVIDE EXISTING TOP OF PIPE ELEVATIONS WITHIN 10 DAYS OF NOTICE TO PROCEED. PROVIDE CONCRETE CRADLE AS REQUIRED FOR ANY VERTICAL SEPARATION LESS THAN 18 INCHES. PLAN NOTES: UX L A FDC PIV CC 18 FV ET RPM E PH WM 6 3 B RF SE T VILLAGE OF WEST CLAY NOTES ALL UTILITY, HVAC, AND MECHANICAL EQUIPMENT SHALL BE SCREENED FROM ALL PUBLIC VIEWSHEDS. BUILDER TO CONTACT WESTCLAY OA (317-574-1164) TO COORDINATE FLAGGING OF THE WESTCLAY PRIVATE UTILITIES. BUILDER WILL BE RESPONSIBLE FOR DAMAGES TO STREET LIGHT WIRING AND PROJECT IRRIGATION SYSTEM CAUSED BY CONTRACTORS. PLEASE CALL 48 HOURS PRIOR TO START OF CONSTRUCTION TO ASSURE LOCATES ARE COMPLETED PRIOR TO EXCAVATION. SANITARY SEWER SERVICE CONNECTION TO BE COORDINATED WITH AND PERMITTED THROUGH THE CITY OF CARMEL DEPARTMENT OF ENGINEERING AND TRICO REGIONAL REGIONAL WASTE DISTRICT. ALL SITE LIGHTING SHALL CONFORM TO VILLAGE OF WESTCLAY STANDARD CLASSIC STYLE FLUTED POLE WITH ACORN STYLE LUMINAIRE, SEE OTHER SITES FOR COMPARISON. COORDINATE FIXTURE SELECTION AND APPROVAL WITH OWNERS ASSOCIATION PRIOR TO ORDERING & INSTALLING. BUILDER MUST SUPPLY DUMPSTER AND TEMPORARY TOILET FACILITIES AT ALL TIMES DURING CONSTRUCTION