Loading...
HomeMy WebLinkAboutSite Plan 03-05-24PROPOSED BUILDING 22,440 SF ±10' B.S.L.10' B.S.L.6' PARKING LOT SETBACK6' PARKING LOT SETBACK 57 ON-SITE SPACES 13 STREET SPACES 2914 6 4 14 R/WR/WR/W 10' B.S.L.10' B.S.L.10' B.S.L. 26'± 25' E HARLESTON STREET PETIGRU STREET27.2' 10'43.5' Canopy Above12' 21.7'9'9'5' D.U.&S.E.5' D.U.&S.E.3 20'± 3 9' 20'±10' B.S.L. BR DB NO PARKINGPICK-UP50'50'50'40'50'ACEHARD WARE OUTD O OR GARDEN CENTER S 00°12'35" W 304.07'N 89°49'51" W 94.84' L=23.90', R=25.00' L=34.32', R=100.00' L=23.92', R=25.00' S 89°47'48" E 150.03'N 00°12'41" E 169.20'N 00°12'41" E 190.00'N 89°48'43" W 411.47'9'9'9'5'18'24'36'24' 18'9'24'20'20'6.5' 6.5' 11.4' 24'18'36'24'18'26.3'12' 21.7' R2' R8' R3' R5' R3'9' R3' R1 5 '5' D.U.&S.E.1.9' CANOPY CB CB CB CB CB T T FL DW FL SC RR SC D SS SS AAA1 A1 TT A A A A A A A A A A A SC TR 6' RC RC RC RC RC RC RC A2 A2 C C C C C C C C C C A1 A1 RC A2 A2 DC A A DC DC DC DC DC DC A2 A2 A1 A1 TT TT A1 D D D D D D D D D D D D D SW SW D D D D D D DD D6 D6 D D D A GN 5' 8' 8' T SC SC SC SC SC FL DW DW FL DW FL FLT DW FL 3.5' R6' 5' A T 8.42' D6 D6DB 5'20'20 ' 9.5'18'GS10' B.S.L.10' B.S.L.R20' R20' R5' DA DA 15' TYP.5'TYP.18.9' 25'15'30'15'1 6 . 5 ' 5.5'15'CANOPY CB CB 11.9' DB 6' 8'8'8'19.6' DB 03/01/2024 TOPOGRAPHIC & BOUNDARY NOTE ENGINEER: ARCHITECT: SURVEYOR: SITE LAYOUT NOTES PLAN NOTES: LEGEND: PLAN NOTES: A C D FL DW B6 CB G F T TR D6 NOTE REFER TO ARCHITECTURAL & FOUNDATION PLANS FOR ALL BUILDING DIMENSIONS. DB SW SS PROJECT NUMBER DRAWING NUMBER SHEET OF SCALE: DATE: DWN BY: CHKD. BY:CIVIL SITE GROUP, INC.GROUP, INC.PROF E SS ION A L E NG INEERIND IA NA PE10910647 STATE OF -oNREGIS TER E DBR IA N S CR O SSACG.066 C2.0INDIANAPOLIS, INDIANA 46225425 W SOUTH STREET, STE 100ALDERSON COMMERCIAL GROUP, INC.SITE PLANROBEY MEDICAL BUILDINGSE CORNER OF HARLESTON ST & PETIGRU DRCARMEL, IN 46033PRELI MI NARY NOT F O R C ONST R U CTI O N GS GN DEVELOPMENT SUMMARY PROPOSED BUILDING G.S.F. = 22,440± LOT AREA = 1.21± Ac ZONING: PUD - VILLAGE OF WEST CLAY PARKING SPACES PROVIDED = 70 PARKING SPACES REQ'D. = TBD by VoWC ANTICIPATED CONSTRUCTION START/END DATE: JUNE, 2024 / JULY, 2025 REVISION RECORD EXISTING CONDITIONS NOTE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, INCLUDING UTILITIES AND DRAINAGE INFRASTRUCTURE BEFORE COMMENCING WITH CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES. R/W RESTORATION NOTE ALL ROADS & R/W MUST BE BROUGHT BACK TO ORIGINAL OR BETTER CONDITION. REPAIRS (i.e. STRIPING, CURB, GRADING, SEEDING, & SIGNAGE) SHALL COINCIDE WITH THE ADJOINING ROAD. PAVING WITHIN CITY R/W NOTE ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY. IF IT WILL BE NECESSARY TO RELOCATE EXISTING UTILITIES, THE EXPENSE OF SUCH RELOCATION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. ALL UTILITY POLES SHALL BE LOCATED WITHIN ONE-FOOT OF THE PROPOSED RIGHT-OF-WAY. SIDEWALK NOTE ALL SIDEWALKS CONSTRUCTED WITHIN THE PUBLIC RIGHT-OF-WAY SHALL COMPLY WITH STANDARD CITY OF CARMEL AND/OR INDOT DETAILS. ALL PROPERTY CORNER MONUMENTS SHOULD BE MARKED PRIOR TO COMMENCING WITH CONSTRUCTION AND PROTECTED DURING ALL CONSTRUCTION ACTIVITY. PROPERTY CORNER MONUMENTS NOTE BR D A1 A2 RC DC RR A2 DA DA CITY OF CARMEL STANDARDS CONTRACTOR TO CONSTRUCT ALL APPLICABLE SITE IMPROVEMENTS WITHIN THE PUBLIC RIGHT-OF-WAY TO THE CITY OF CARMEL CURRENT STANDARDS AND SPECIFICATIONS. PROVIDE CURB TO DIRECT PEDESTRIAN TRAFFIC TO DESIGNATED CROSSING LOCATION. EXISTING TREE, STREET LIGHTING, ELECTRICAL, AND IRRIGATION SYSTEMS TO BE PROTECTED AND OR RESTORED TO PROCONSTRUCTION CONDITIONS TO THE ACCEPTANCE OF THE VILLAGE OF WESTCLAY OWNERS ASSOCIATION BUILDER TO CONTACT WESTCLAY OA 317-574-1164 TO COORDINATE FLAGGING OF THE WESTCLAY PRIVATE UTILITIES. BUILDER WILL BE RESPONSIBLE FOR DAMAGES TO STREET LIGHT WIRING AND PROJECT IRRIGATION SYSTEM CAUSED BY CONTRACTORS. PLEASE CALL 48 HOURS PRIOR TO START OF CONSTRUCTION TO ASSURE LOCATES ARE COMPLETED PRIOR TO EXCAVATION SANITARY SEWER SERVICE CONNECTION TO BE COORDINATED WITH AND PERMITTED THROUGH THE CITY OF CARMEL DEPARTMENT OF ENGINEERING AND CLAY TOWNSHIP REGIONAL WASTE DISTRICT BUILDER SHALL NOT ALTER ELEVATION OF DRAINAGE SWALES, INLETS, FIRE HYDRANTS, WATER VALVES, MANHOLES, CURBS OR ASPHALT WITHOUT PRIOR APPROVAL FROM THE CITY OF CARMEL BUILDER AND LOT OWNER SHALL ASSUME ALL LIABILITY ASSOCIATED WITH REQUIRED MINIMUM FLOOD PROTECTION GRADES AND MINIMUM LOWEST ADJACENT GRADES ALL WORK WITH RIGHT-OF-WAY SHALL BE COORDINATED WITH AND PERMITTED THROUGH THE CITY OF CARMEL DEPARTMENT OF ENGINEERING 317-571-2441 ALL MUD IN STREETS AND OR ADJACENT PARKING AREAS FROM TRUCKS LEAVING LOT TO BE CLEANED AT THE END OF EACH DAY BUILDER MUST COMPLY WITH ALL ORDINANCES GOVERNING SITE EROSION & SEDIMENT CONTROL EXISTING CURB TO BE SAWCUT, PROPOSED CURB SHALL BE DOWELED INTO EXISTING CURB IN COORDINATION WITH REQUIREMENTS OF THE CITY OF CARMEL DEPARTMENT OF ENGINEEING 317-571-2441 EXISTING CURB TO BE SAWCUT, PROPOSED CURB SHALL BE DOWELED INTO EXISTING CURB IN COORDINATION WITH REQUIREMENTS OF THE CITY OF CARMEL DEPARTMENT OF ENGINEEING 317-571-2441 EXISTING CURB TO BE SAWCUT, PROPOSED CURB SHALL BE DOWELED INTO EXISTING CURB IN COORDINATION WITH REQUIREMENTS OF THE CITY OF CARMEL DEPARTMENT OF ENGINEEING 317-571-2441 EXISTING CURB TO BE SAWCUT, PROPOSED CURB SHALL BE DOWELED INTO EXISTING CURB IN COORDINATION WITH REQUIREMENTS OF THE CITY OF CARMEL DEPARTMENT OF ENGINEEING 317-571-2441 SITE MUST MEET ALL CURRENT ADA GUIDELINES SIDEWALK JOINTING PATTERNS TO MATCH CURRENTLY ESTABLISHED PATTERNS. BUIDER TO COORDINATE FINAL LAYOUT WITH THE OWNERS ASSOCIATION DECLARANT RESERVES THE RIGHT FOR ITSELF AND THE ASSOCIATION TO RECONFIGURE THE COMMON PARKING LOTS FROM TIME TO TIME, WHICH RECONFIGURATION MAY INCREASE OR DECREASE THE NUMBER OF PARKING SPACES AVAILABLE ALL SITE LIGHTING SHALL CONFORM TO VILLAGE OF WESTCLAY STANDARD CLASSIC STYLE FLUTED POLE WITH ACORN STYLE LUMINAIRE, SEE OTHER SITES FOR COMPARISON. COORDINATE FIXTURE SELECTION AND APPROVAL WITH OWNERS ASSOCIATION BUILDER MUST SUPPLY DUMPSTER AND TEMPORARY TOILET FACILITIES AT ALL TIMES DURING CONSTRUCTION DUMPSTER ENCLOSURE TO MATCH ARCHITECTURAL MATERIALS OF THE PRIMARY STRUCTURE APPROVED AS NOTED KDK 03/27/2024 SEE PRELIMINARY SITE APPROVAL FOR WALK, LANDSCAPE BED, AND LIGHTING COMMENTS EXISTING CURB TO BE SAWCUT, PROPOSED CURB SHALL BE DOWELED INTO EXISTING CURB IN COORDINATION WITH REQUIREMENTS OF THE CITY OF CARMEL DEPARTMENT OF ENGINEEING 317-571-2441 R/WR/WR/W HARLESTON STREET PETIGRU STREETFFE =906.90±NO PARKINGPICK-UPRF EX. 30" RCPCURB INLET TYPE A TC=906.75 GUT=906.25 INV=903.0 (S-12" RCP)EX. 30" RCPEX. 18" RCP202 5' Ø DOWNSTREAM DEFENDER BMP TC= 908.5± INV=902.0 (E-12" RCP) INV=901.0 (N-18" RCP) INV=900.5 (W-18" RCP) CURB INLET TYPE A TC=907.00 GUT=906.50 INV=902.75 (N-12" RCP) INV=902.65 (W-12" RCP) 201 200 300 301 BMP M.E.CURB INLET TYPE A TC=906.50 GUT=906.00 INV=902.25 (W-15" RCP) CURB INLET TYPE A TC=906.75 GUT=906.25 INV=902.1 (E-15" RCP) INV=902.0 (S-15" RCP) CURB INLET TYPE M TC=906.55 GUT=906.05 INV=901.9 (N-15" RCP) INV=901.8 (S-18" RCP) 03/01/2024 TOPOGRAPHIC & BOUNDARY NOTE ENGINEER: ARCHITECT: SURVEYOR: PROJECT NUMBER DRAWING NUMBER SHEET OF SCALE: DATE: DWN BY: CHKD. BY:CIVIL SITE GROUP, INC.GROUP, INC.PROF E SS ION A L E NG INEERIND IA NA PE10910647 STATE OF -oNREGIS TER E DBR IA N S CR O SSACG.066 C3.0INDIANAPOLIS, INDIANA 46225425 W SOUTH STREET, STE 100ALDERSON COMMERCIAL GROUP, INC.GRADING AND DRAINAGE PLANROBEY MEDICAL BUILDINGSE CORNER OF HARLESTON ST & PETIGRU DRCARMEL, IN 46033PRELI MI NARY NOT F O R C ONST R U CTI O N REVISION RECORD EXISTING CONDITIONS NOTE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, INCLUDING UTILITIES AND DRAINAGE INFRASTRUCTURE BEFORE COMMENCING WITH CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES. R/W RESTORATION NOTE ALL ROADS & R/W MUST BE BROUGHT BACK TO ORIGINAL OR BETTER CONDITION. REPAIRS (i.e. STRIPING, CURB, GRADING, SEEDING, & SIGNAGE) SHALL COINCIDE WITH THE ADJOINING ROAD. UTILITY LOCATE NOTE UTILITY VALVE NOTE LEGEND: PLAN NOTES: FLOOD NOTE ALL CONCRETE PIPE JOINTS SHALL BE CONTINUOUS O-RING RUBBER GASKET CONFORMING TO ASTM C 443 GENERAL NOTES CONTRACTOR TO KEEP EXISTING PAVEMENT SURROUNDING THE SITE "BROOM CLEAN" AND FREE OF SOIL OR AGGREGATE THAT MIGHT BE BROUGHT OFF-SITE. DEPENDING ON THE CONSTRUCTION SEASON, MOISTURE CONTENT AND PROPERTIES OF THE SOILS ON SITE, CHEMICAL MODIFICATIONS AND/OR LIME STABILIZATION MAY BE REQUIRED. SEE SHEET C9.0 FOR SPECIFICATIONS. BENCHMARK ### GRADING NOTES RF NOTE REFER TO ARCHITECTURAL & FOUNDATION PLANS FOR ALL BUILDING DIMENSIONS. CONTRACTOR NOTE NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. BUILDER SHALL NOT ALTER ELEVATION OF ADJOINING LAND BUILDER SHALL NOT ALTER ELEVATION OF ADJOINING LAND BUILDER SHALL NOT ALTER ELEVATION OF ADJOINING LAND BUILDER TO ENSURE POSITIVE DRAINAGE AWAY FROM STRUCTURE SITE MUST MEET ALL CURRENT ADA GUIDELINES APPROVED AS NOTED KDK 03/27/2024 R/WR/WR/W E HARLESTON STREET PETIGRU STREETFV C.O. INV.=901.9± L FFE =906.90± G GAS SERVICE METER W/ BOLLARD PROTECTION PER CENTERPOINT ENERGY STDS.FIELD VERIFY LOCATION/DEPTHOF EXISTING SAN. LATERALNO PARKINGPICK-UP50'50'50'40'50'RF WM PIV FDC 3 6 6 6-INCH WET TAP/VALVE EXISTING MAIN SE ET A A A A A A A A A A AA GAS MAIN TO BE RELOCATED BY CENTERPOINT ENERGY T PH EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT 18 18 A EX. SANITRY MH TC=905.86 INV=893.80 (E-8" PVC) INV=893.00 (W-8" PVC) EX. SANITRY MH TC=906.47 INV=898.48 (W-8" PVC) 03/01/2024 TOPOGRAPHIC & BOUNDARY NOTE ENGINEER: ARCHITECT: SURVEYOR: PROJECT NUMBER DRAWING NUMBER SHEET OF SCALE: DATE: DWN BY: CHKD. BY:CIVIL SITE GROUP, INC.GROUP, INC.PROF E SS ION A L E NG INEERIND IA NA PE10910647 STATE OF -oNREGIS TER E DBR IA N S CR O SSACG.066 C5.0INDIANAPOLIS, INDIANA 46225425 W SOUTH STREET, STE 100ALDERSON COMMERCIAL GROUP, INC.UTILITY PLANROBEY MEDICAL BUILDINGSE CORNER OF HARLESTON ST & PETIGRU DRCARMEL, IN 46033PRELI MI NARY NOT F O R C ONST R U CTI O N REVISION RECORD EXISTING CONDITIONS NOTE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, INCLUDING UTILITIES AND DRAINAGE INFRASTRUCTURE BEFORE COMMENCING WITH CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES. R/W RESTORATION NOTE ALL ROADS & R/W MUST BE BROUGHT BACK TO ORIGINAL OR BETTER CONDITION. REPAIRS (i.e. STRIPING, CURB, GRADING, SEEDING, & SIGNAGE) SHALL COINCIDE WITH THE ADJOINING ROAD. UTILITY LOCATE NOTE UTILITY VALVE NOTE IRRIGATION NOTE ISDH NOTES THE WATER LINES THROUGHOUT THE PROJECT SHALL BE INSTALLED WITH AT LEAST 60-INCHES OF COVER TO PROVIDE PROTECTION FROM FREEZING. WHERE WATER LINES AND SEWERS (STORM AND/OR SANITARY) CROSS AND THE WATER LINE CANNOT BE PLACED ABOVE/BELOW THE SEWER WITH A MINIMUM OF 18-INCHES VERTICAL CLEARANCE, THE SEWER MUST BE CONSTRUCTED OF WATER WORKS GRADE DUCTILE IRON PIPE WITH MECHANICAL JOINTS OR SDR 26 PVC PRESSURE SEWER PIPE WITH COMPRESSION FITTINGS, & SHALL BE PRESSURE TESTED TO ASSURE WATER TIGHTNESS PRIOR TO BACK-FILLING. SANITARY SEWERS SHOULD HAVE A MINIMUM OF 3 FEET OF COVER. LEGEND: UTILITY NOTES 1. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO THEIR PHASE OF WORK. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATIONS FOR EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. 2. STANDARD SPECIFICATIONS FOR THE LOCAL GOVERNING AGENCY SHALL APPLY FOR ALL SANITARY SEWERS, STORM SEWERS, AND WATER MAINS. 3.ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING UNDER PAVED AREAS TO BE BACKFILLED WITH GRANULAR MATERIAL. 4. ALL WATER MAINS TO HAVE 60" MINIMUM COVER OVER TOP OF PIPE. 5. STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE WITH STATE BOARD OF HEALTH REQUIREMENTS. (APPLIES TO COMMERCIAL ONLY) 6. CONTRACTOR RESPONSIBLE TO INSTALL ALL UNDERGROUND CONDUIT PER UTILITY COMPANY'S SPECIFICATIONS. 7. CONTRACTOR RESPONSIBLE FOR RESTORATION TO ALL AREAS AFFECTED DURING CONSTRUCTION. REFER TO THE TOWN OF FISHERS STANDARDS FOR RESTORATION REQ'S. 8. CONTRACTOR TO LOCATE ALL EXISTING UTILITIES AT ANY PROPOSED CROSSING AND PROVIDE EXISTING TOP OF PIPE ELEVATIONS WITHIN 10 DAYS OF NOTICE TO PROCEED. PROVIDE CONCRETE CRADLE AS REQUIRED FOR ANY VERTICAL SEPARATION LESS THAN 18 INCHES. PLAN NOTES: UX L A FDC PIV CC 18 FV ET RPM E PH WM 6 3 B RF SE T REVISED LIGHT POLE (TYP.) LOCATION, MATCH SPACING AND PLACMENT SCHEME ESTABLISHED FOR OTHER COMMERCIAL BUIDINGS ALLONG PETIGRU STREET ALL UTILITY, HVAC, AND MECHANICAL EQUIPMENT SHALL BE SCREENED FROM ALL PUBLIC VIEWSHEDS APPROVED AS NOTED KDK 03/27/2024 REVISED LIGHT POLE (TYP.) LOCATION, MATCH SPACING AND PLACMENT SCHEME ESTABLISHED FOR OTHER COMMERCIAL BUIDINGS ALLONG PETIGRU STREET