HomeMy WebLinkAbout07030150 Site Plan
MANCHESTER - ELEV 2C
RIGHT HAND - Full Brick
FULL BSMT - 9' Walls
3 CAR - Side Entry
Wd Deck "1"
Gar. FFE - 768.6
11st Fir FFE = 770.4
ljOW = 769.4
!:Ismt FFE = 760.6
qlrive Slope = 3.2%
I
"BASE HOUSE STANDARD FEATURES"
9' FULL BASEMENT
BRICK 3 SIDES
PATIO
3 CAR SIDE ENTRY GARAGE
(2) 4X4 WINDOW WELLS & (1) 2X2
WINDOW WELL
"SELECTED FEATURES"
BRICK 4 SIDES
(3) 4x4 WINDOW WELLS
DECK"1"
STMINLET
TC=765.40
'"
w
;:
W
lfJ
~ ::;
f-
lfJ
Co
N 7.9'
co W
(") lfJ
.,- ""
::i
ci
Co
CL~
I'"
'"
"-
/'
~I
Flood Hazard Note:
"-
14'
~ Q
"
a
, ~r
4.00'
, ~
w
~ti
/
Note:
Minimum Front yard - 25'
Minimum Side Yard - 3'
Minimum Aggregate - 6'
(Between Houses)
Minimum Rear Yard - N/A
LOT # 208
+14,759~SE__
NO PAD PER PLAN
MFPG 768.6 PER PLAN
143.84'
==!ill}=
--
,
~
0:
'" ~
I "0:0 ~
w<(~
wcoz N
L 0: ~
I ~
e-
18.46'
e- "
~ N
~ o:~
m we-
e-~
<n~
wm
I~
"S
Z~
"'~
~
J\,
.R\
Lot Number 208 lies within Flood Hazard Zone "X" per the
scaled location on the Flood Insurance Rate Maps for
Hamilton County, Indiana (Community Pahel #18057C0235F,
dated February 19, 2003).
Note:
This drawing is based upon construction plans and/or record
drawings prepared by others and is not b~sed upon a field survey.
COOR Consulting & Land Services, Corp] does not warrant the
correctness or integrity of this informationl The contractor/owner
should verify existing conditions prior to oonstruction. Any varying
field conditions or any discrepancy with the information contained
hereon should be immediately reported tol COOR Consulting & Land
Services, Corp.; failure to do so would re ult in the contractor/owners
assumption of liability.
@@lJj)"'OlJ~ijUlJj)gD!! !~@@fS'
@@C?~@C?~llo@[jj)
303 WEST MAIN STREET tNIGHTSTOWN.INOIANA
(666) 593-2667 (765) 345-5943 FAX#: (765) 345-5692
DATE: 03/15/07 JOB #2003-100. 06 REVISIONS:
I
I
3 .7'
Note:
&@@Q!JDlJi]@@ [f!]@[[U[lD
~@@lD@8 1] II = ~@'
I
SAN MH 742
TC=766.12!
I
IXX.XI = Proposed IGrade
--- = Drainage Flow
I
XX.X = Existing Grade
Conc Flatwork Sq. Ft = :1'1643
Public Walk Sq Ft = :t143
Sod Sq Y ds = :t353
Seeding Sq Ft = :t7711
Contractor should verify site specific information depicted
hereon with the approved construction plans for this
development. Also, Contractor should reference Architectural
plans for foundation orientation and dimensions.
Note:
The proposed construction grades, contours, and proposed structure
elevations as depicted hereon are based upon information provided
upon the approved construction documents prepared for this
development. Unless otherwise stated hereon, no information
pertaining to but not limited to, fluctuating water tables elevations,
soil types, and conditions within the building areas of this
development have been provided and \or referenced on said
documents. With the excavation of the proposed structure
foundations, certain care and observations should be made in regard
to such conditions as soil types and fluctuating water tables. During
the excavation process should any unsuitable soils or ground water
be witnessed, the builder shall be immediately notified for further
examination and consultation. At the builders discretion, additional
construction techniques may be necessary to alleviate future
problems.
@[}{]rn:ffilffil';'7@ffilrn:rn:~
rn:~U&Urn:~
~~@LJO@1m ~
INSTR. #200500009933
PC 3, SLIDE 580
C.O.C.#200500011991
LOT # 208
14046 BRAZOS DRIVE
CARMEL, IN 46033
PLOT PLAN
Prepared For:
~
n.~:,
~~1"7LeL/
'i!.."liE.b
!!!~.,- I
Pulte Homes of Indiana