Loading...
HomeMy WebLinkAbout07030148 Site Plan . ~~ The &hneideT CO'J'O"Uon . 8901 OUt Avenue Historic fort Harrison Indianapollil, Incti!l.n8 46218-1037 317-826-7100 Scmeider 317-828-7200 ~.AX This Plot Plan Prepared For: R.H. of Indiana Lot # 142 , containing 7,800 S.F.:I:', in Stanford Park Section' 2A INSlR. , 200600014565 PC 4, Slide 42 ; Clay Twp, HamDton County . Sec 29, T18N, R3E 3443 Burlingame Boulevard (50'R/W) Carmel, IN 46074 Prepared Date: 03/14/07: By. AMA Proposed Buyer(s): Santash-Pandey Engineerina; Sun-eJln<< Landscape Architecture GIS .lJS Geology Plot Plan Legend [QQ[[] Proposed Grode, 000.0 E,isting Grodes __000.0-- Contour Grade * Appro,. Lateral Locotion - . - Sanitary Sewer Lines -" - Storm Sewer Lines - 1,/ - Water Service Lines - - - - - - - Sub-Surface Drain lines . Monhole (Sanitary or Storm) . Beehive Inlet (Storm) II1II Curb Inlet (Storm) D End Section (Storm) .... Fire H)'Iront - " " " - " c " _ Flow line of swole Buiiding Line -(BL / BSL) - - - - - - - Easement Line Community Restrictions: Side Yard =3' min. Rear Yard = N/A Aggregate = 6 (B.H.) Note: Sanitary Sewer Top of Casting Information Upstream Manhole, TC= 915.BO Downstream Manhole, TC=915.79 per plan. 'RH. of Indiana . Finished Floor Elevation Information ;pad Grode = 915.5 per plan .,Pad Grode + 0.7' = Garage FFE (916.2) :'Garage FFE + 1.5' = Residential FFE (917.7) ','Residential m - 9.0' = Basement FFE (908.7) .. Note: The garoge finished floor elevation Is 2.0' above the curb at the drive, per plan. Note: 1he contractor is to maintain a minimum distance of ten feet (10') between the sonitry sewer and water line laterols. Ground Cover Calculations: ,Orive =513 SFI \'Public Walk =244 SFI Private Walk = 70 SF I : H)'Iroseeding =2,541 SFI . Sod = 343 SYI. from Rear of residence. Optional Sod Pockoge H)'Iraseeding = 975 SF I Add!. Sod Pkg.= 174 SYt. 10 Rear easement. - TC=9H.00 ER PUN BURUNGAME BOULEVARD 30.0' . B-B APRON ~ 914.6 SIR. # 735 !5' .G.B.L. TC=915.79 ~2.5 B.L. PER PLAN 5' WAU< . . 914. 36.0' 26.0' 16' ORIVE 20' O.U.&S. 22.5' B. - -=-r --=- -----J 25:-;) I 20' O.U.&S.S.E. 22.5' 8.L. 25' .B.L 16.0' 20.08 "'8 ~ }.62 1 "TWOCAR !:<j 8. GARAGE ~ -I 4.00'1 1 I I I I SOIl . 16.0' 050, c:: . 013.63' ~ SUl.lP PUMP PUR &6.67' o o c:i N BSMNT SOIl ~ ~ l" ~_ HARRISON A FRM&MSY RE~OENCE 40.00' '" t; I en. '" 1 b '" 39.6' 19f5.0 1 I _ _ 34.6~ -2"lION~ S.QQJ PACKAGE 15' O.E. en. '" b '" 1914.8 I 65.00' I 914.B I EXISTING lAKE #J N.P. ElfV=90B.BO 100 '11l ElfV.=91274 This drawing is not intended to be presented as 0 retrocement or original boundary survey, o route survey, or 0 Surveyor Location ~Mt-Iazard Statement: The accuracy of any flood hazard data shown on this report is Subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced nood insurance rate map. ALL of the within described land DOES NOT LIE within that special nood haZArd zone A as said land plots by scale on nood insurance rate map #. 18057 0205F for City of Carmel, Indiana (maps dated February 19. 2003). ~GNA lURE : DAlE: ~GN^ lURE REPRESENTS CON~RM^ TION Of RECEIPT Of PLOT PLAN BY CUSTIlIlER. Note: This drawing is based on construction pIons or record drawings, and is not bosed upon Q field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately. foiling to do so results in the contractors assumption of 011 liability. Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-five feet (25'), however a dwelling may be increased in height to thirty-five feet (35') pra~ded the ,ide and reor )'lrd, ore increased on additional one foot (1') for each one foat (1') the structure exceeds the first twenly-five feet (25') in height. Lot # 142 , Detoil of Grouod/ Storm Vb07.0070085 Water flow pattern for individuol lots. ~ ~ =~= ~ :M: 1/7-fi I I Assumed North Scale : 1" = 30' Note: Builder to ensure positive drainage away from ,tructure(,). Sidewalk to be placed l' from property line, 4' from bock of curb, per plan. .. ~I ~~t ~ TYPICAL SWALE SECTION SIR. , 740 le.9IS.80 PER PLAN . I 1 I~ 1;1; I Note: The basement eJevatJoo, depIcted hereon, has been determined and based on the pod grades and/or contours taken from the construction plans for this subdIvision. Unless stated, no information about fluctuating water tables, sol conditions, or soli t)1les has been provided or stated on sold plans. This lot Is located near a body of water. lot or sol conditions may reqtJire that the basement floor elevotlon be held 2 foot above normal PO<X elevation. Site investigation may be needed if water Is encountered during the excavation process or if other known water elevation or sols conditions are present Investigation and any remedial procedures Is at the discretion of the buMder to determine and take approprlate steps of action. If any ground water Is encountered during excavation the bulder is encouraged to contact The Schneider CorpOrotion to discuss possible COUrses of action. I I I I I L Note: Sump pump(s) to be placed by buDder as needed. FLOOO HAZARD STATEMENT: CERnFICA nON ' ,,\\\\\\\1111111/1/1/1/1111. : ,,\"'~ L W% I ~,~ . Cp ~ ~;:".~'\ .............../('h~ ~ ~....~G\S T~I?~.........A~ "'~ ,<<- No O--.-o"? i ( 50303 \) Ii % ..... STATE OF ..... ,~ ?: <" .... .... ~ i? ~ ..(.I;":'':(DIA~.!:'" ~~~ ~ /f/) S....U..ii\t\.~ #' I ~4111. l\' ~\~~ ~'":'"'N