Loading...
HomeMy WebLinkAbout07030152 Site Plan Note: This drawing Is based on construction plans or record drawings, and Is not based upon 0 fleld survey. The Schneid" Corporation does not warrant the accuracy or sufffclency of this Information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing shoUld be reported to The Schneider Corporation Immsdlately; foiling to do so results In the contractors assumption of 011 liability. Note: Plot Plan legend The basement elevation, depicted hereon, has been determined and based on I]QQ]] Proposed Grades the pad ~ades and/<K contours taken from the constnJctlon pions for thla 000.0 Existing Grodes subdivisIon. Unless stated, no information about fluctuating water tables. BOn __000.0- Contour Grade conditIons, or soH t)pes has been provided or alated on said plana.' This lot * Approx. lateral location Is loooted near a body of water. lot or sol conditions may require: that the _ . _ Sanitary Sewer Unes basement lloor etiMJtlon be hBld 2 foot obol'e 1I01JJ1~ pool e1ewtlon. Site _ ,,_ Storm Sewer Unes investigation may be needed if water Is encountered during the exoovotlon _ \I _ Water Service LInes process or If other known water elevation or solis conditions ore prueI'll _ _ - - - - _ Sub-Surface Drain Unes Investlgatlon and any remedial procedures Is at the discretion of th'e buDder . Manhole (Sanitary or Sto~ determine end take appropriate eteps of action. If any ground water Is . Beehive Inlet (Storm) encountered during excavation the buDder Is encouraged to contact The III Curb Inlet (Storm) Schneider Corporation to dlsCt.lBS possible courses of action. D End Section (Storm) AFire-Hydrant _ 000 _ 000 _ Flow Une of swale ~ The Schneider CorporaUOD 8901 0LiI AftDue --- Indianapolla, Indiana 48218-tOS'l 317-826-7100 317-828-7200 fAX 1Dalno..... llunoJiDa Londooape _ore GIS'LIS GeoIoc, This Plot Plan Prepared For: Trinity/Beazer Homes Lot # 3 ,containing 8,076 SJ.:!:, in Yorktown Woods Sectioo # 1 Instrument # 200600017282 C.O.C. # 200600023419 P.C. # 4, Slide # 48 Hamilton County, Clay Township Section 19, Township 18 N, Range 4 EAST .14211 LAURA V1STA OR. (50' R/W) Carmel, IN 46074 Prepared Date: 02/05/07 : By. KAG Community Restrictions: Side Yard = 6' (BH) Rear Yard = 20' Zoning = ROSO III Note: Sanitary Sew" Top of Costing Information Upstream Manhole, TC= 826.30 Downstream Manhole, TC=823.50 Per Plan. Finished Floor Elevation Information Pod Grade = 827.73 per plan Pod Grode + 0.33' = Garage FIT (828.06) Garage FIT + 1.04' = Residential FIT (829.10) Residential FIT - 9.0 ' = Basement FFE (820.10) Driveway Slope = 4.1" Note: Ths contractor Is to maintain o minimum distance of ten feet (lD') between the sanitary sewer and water line laterals. Note: The garage finished floor elevation Is 2.6' above the curb at the drive, per plan. Ground Cover Calculations: Drive = 1,198SF:!: Public Walk = 242 SF:!: Private Walk =11 SF:!: Rear Yard = 1,861 SF:!: Sod = 281 SY:!:, from rear of home. FLOOD HAZARD STATEMENT CERTlFICA TlON ""I\\\\lIIIIIIIIIII"lill/' #~c. L /l'/ij~ ~ ..~,.'~ . L1~1)/.. ~ ~ ""'" ~'.................IT (/JJ'%-. ~ <..~...~G\s T.E:'1?i-.........A~ '" c::;:...~v No () ". ;<> ~ I ( 50303 \ , :::: ~ : =:: % \. STATE OF..... ~ '" <,," ..:;::: ~ '. I .... .' <'\. ~ ~ ..(~;-...IvDIA"';:... ~~~ ~;:{f ..S.U'R~\~~ 'lillli'II/IIIIII\I\l11I1I '\.)'-. l , f--f1 This drawing Is not Intended to be represented os 0 retracement or original boundary survey, 0 route survey, or a Surveyor Location Report. Flood Hazard Statement: The accuracy of any flood hazard data shown on this plot plan Is subject to mop scale uncertainty and to any other uncertainty In location or elevation on the referenced flood insurance rate mote (FIRM). None of the within described land lies within thot special flood hazard zone "A", os sold land plots by scale on Community Mop Panel # 18057C 0026 F of the fiood Insurance rate mops (FIRM) for the city of Carmel, HamOton County, Indiana, Doled February 19, 2003. NOlI: SUMP PUMP{S) TO BE PLACED BY BUILDER AS NEEDED. LOT # 3 VB # 07.0068161 ~ ~ =~= ~ Assumed North Scale: I" = 30' o 10 20 30 ~ SCALE l' = 30' O.toll of t)lllcol Ground Water flow pattern for IndMdu~ lot.. l1t] -M- -w- - - -- Note: Builder to ensure positive drainage away from structure{s). 00'lJ 148.59 I-I 73.00 lHREE CAR ~ GARAGe: l'J .00' q 36.00' ~ ~I~ a '" in ~ a ~~~ r 00' 8.00' . ~~ ~, ;:; a ,! '~~ ",['1 q ;;1- q, I~ p ;g~ "'I'" S(lm ;;;0 =' . !if~ 26.5' I~~ I~ I'" 10 120.62' ~ TYPICAL SWAlE SECTION , NOTE: I IN THE RESIDENTIAL DISTRICTS UMITlNG HEIGHT TO TWENTY-FIVE (25) FEET. A' DWELLING MAYBE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PRO<1DED THE SIDE AND REAR YARDS ARE INCREASED AN ADDITlONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1.