HomeMy WebLinkAbout07030152 Site Plan
Note:
This drawing Is based on construction plans or record drawings,
and Is not based upon 0 fleld survey. The Schneid" Corporation
does not warrant the accuracy or sufffclency of this Information.
Contractors should verify existing conditions prior to any
construction. Any discrepancy found on this drawing shoUld be
reported to The Schneider Corporation Immsdlately; foiling to do
so results In the contractors assumption of 011 liability.
Note:
Plot Plan legend The basement elevation, depicted hereon, has been determined and based on
I]QQ]] Proposed Grades the pad ~ades and/<K contours taken from the constnJctlon pions for thla
000.0 Existing Grodes subdivisIon. Unless stated, no information about fluctuating water tables. BOn
__000.0- Contour Grade conditIons, or soH t)pes has been provided or alated on said plana.' This lot
* Approx. lateral location Is loooted near a body of water. lot or sol conditions may require: that the
_ . _ Sanitary Sewer Unes basement lloor etiMJtlon be hBld 2 foot obol'e 1I01JJ1~ pool e1ewtlon. Site
_ ,,_ Storm Sewer Unes investigation may be needed if water Is encountered during the exoovotlon
_ \I _ Water Service LInes process or If other known water elevation or solis conditions ore prueI'll
_ _ - - - - _ Sub-Surface Drain Unes Investlgatlon and any remedial procedures Is at the discretion of th'e buDder
. Manhole (Sanitary or Sto~ determine end take appropriate eteps of action. If any ground water Is
. Beehive Inlet (Storm) encountered during excavation the buDder Is encouraged to contact The
III Curb Inlet (Storm) Schneider Corporation to dlsCt.lBS possible courses of action.
D End Section (Storm)
AFire-Hydrant
_ 000 _ 000 _ Flow Une of swale
~
The Schneider CorporaUOD
8901 0LiI AftDue
---
Indianapolla, Indiana 48218-tOS'l
317-826-7100
317-828-7200 fAX
1Dalno.....
llunoJiDa
Londooape _ore
GIS'LIS
GeoIoc,
This Plot Plan Prepared For:
Trinity/Beazer Homes
Lot # 3 ,containing 8,076 SJ.:!:, in
Yorktown Woods
Sectioo # 1
Instrument # 200600017282
C.O.C. # 200600023419
P.C. # 4, Slide # 48
Hamilton County, Clay Township
Section 19, Township 18 N, Range 4 EAST
.14211 LAURA V1STA OR. (50' R/W)
Carmel, IN 46074
Prepared Date: 02/05/07 : By. KAG
Community Restrictions:
Side Yard = 6' (BH)
Rear Yard = 20'
Zoning = ROSO III
Note: Sanitary Sew"
Top of Costing Information
Upstream Manhole, TC= 826.30
Downstream Manhole, TC=823.50
Per Plan.
Finished Floor Elevation Information
Pod Grade = 827.73 per plan
Pod Grode + 0.33' = Garage FIT (828.06)
Garage FIT + 1.04' = Residential FIT (829.10)
Residential FIT - 9.0 ' = Basement FFE (820.10)
Driveway Slope = 4.1"
Note: Ths contractor Is to maintain
o minimum distance of ten feet (lD')
between the sanitary sewer and
water line laterals.
Note: The garage finished floor elevation
Is 2.6' above the curb at the drive, per
plan.
Ground Cover Calculations:
Drive = 1,198SF:!:
Public Walk = 242 SF:!:
Private Walk =11 SF:!:
Rear Yard = 1,861 SF:!:
Sod = 281 SY:!:, from rear of home.
FLOOD HAZARD STATEMENT
CERTlFICA TlON
""I\\\\lIIIIIIIIIII"lill/'
#~c. L /l'/ij~
~ ..~,.'~ . L1~1)/.. ~
~ ""'" ~'.................IT (/JJ'%-.
~ <..~...~G\s T.E:'1?i-.........A~
'" c::;:...~v No () ". ;<> ~
I ( 50303 \ ,
:::: ~ : =::
% \. STATE OF..... ~
'" <,," ..:;:::
~ '. I .... .' <'\. ~
~ ..(~;-...IvDIA"';:... ~~~
~;:{f ..S.U'R~\~~
'lillli'II/IIIIII\I\l11I1I
'\.)'-. l , f--f1
This drawing Is not Intended to be represented os 0 retracement or
original boundary survey, 0 route survey, or a Surveyor Location Report.
Flood Hazard Statement: The accuracy of any flood hazard data shown on
this plot plan Is subject to mop scale uncertainty and to any other
uncertainty In location or elevation on the referenced flood insurance rate
mote (FIRM). None of the within described land lies within thot special flood
hazard zone "A", os sold land plots by scale on Community Mop Panel #
18057C 0026 F of the fiood Insurance rate mops (FIRM) for the city of
Carmel, HamOton County, Indiana, Doled February 19, 2003.
NOlI:
SUMP PUMP{S) TO BE PLACED
BY BUILDER AS NEEDED.
LOT # 3
VB # 07.0068161
~
~
=~=
~
Assumed North
Scale: I" = 30'
o 10 20 30
~
SCALE l' = 30'
O.toll of t)lllcol Ground
Water flow pattern for
IndMdu~ lot..
l1t]
-M-
-w-
- - --
Note: Builder to ensure
positive drainage away
from structure{s).
00'lJ
148.59
I-I
73.00
lHREE CAR ~
GARAGe: l'J .00' q
36.00' ~ ~I~ a '"
in
~ a ~~~ r
00' 8.00'
. ~~
~, ;:;
a
,!
'~~
",['1
q
;;1-
q,
I~ p
;g~
"'I'"
S(lm
;;;0
=' .
!if~
26.5'
I~~
I~
I'" 10
120.62'
~
TYPICAL SWAlE SECTION
,
NOTE: I
IN THE RESIDENTIAL DISTRICTS UMITlNG
HEIGHT TO TWENTY-FIVE (25) FEET. A'
DWELLING MAYBE INCREASED IN HEIGHT
TO THIRTY-FIVE (35) FEET PRO<1DED
THE SIDE AND REAR YARDS ARE
INCREASED AN ADDITlONAL FOOT FOR
EACH FOOT SUCH STRUCTURE EXCEEDS
TWENTY-FIVE (25) FEET IN HEIGHT.
PER CARMEL ZONING ORDINANCE 26.1.1.