HomeMy WebLinkAboutElevationsREFER TO DESIGN STANDARDS "LOBBY AREAS" CHAPTERFOR MAIN REQUIREMENTS RELATED TO THIS SHEET.ARCHITECT IS RESPONSIBLE FOR DESIGNING PROJECT INACCORDANCE WITH THE ENTIRE DESIGN STANDARDS.REFER TO THE 700 SERIES CRITERIA PLANS FOR ADDITIONALINFORMATION.REFERENCE NOTESA.B.1.2.3.ALL SWITCH AND RECEPTACLE DEVICES IN THE LOBBYSHALL BE SIMILAR TO "DECORA" STYLE, OR ACCEPTEDSUBSTITUTION BY LISTED MANUFACTURERS. COLOR OFTHE DEVICES AND COVER PLATES IS SPECIFIED UNDER THECOVER PLATE COLOR TABLE IN THE BUILDING PRODUCTMANUAL.COORDINATE PLACEMENT OF ELECTRICAL DEVICES,DIFFUSERS, ACCESS PANELS, SYSTEMS INTERFACE ANDINTERIOR GRAPHICS SO AS NOT TO ENCROACH ON KEYFOCAL ELEMENTS.ALL RECEPTACLE AND SWITCH COVERS ON DARK ACCENTWALLS TO RECEIVE BLACK SWITCHES AND FACEPLATES.ALL OTHER RECEPTACLE AND SWITCHFACEPLATES ANDSWITCHES ARE TO BE WHITE.GENERAL NOTESCRITERIA NOTESCRITERIA NOTES ARE SHOWN CATEGORIZED BY DISCIPLINE ANDCOULD BE INTERPRETED TO APPLY TO MORE THAN ONEDISCIPLINE. FOR EFFICIENCY, NOTES ARE ONLY SHOWN UNDERONE PREDOMINANT DISCIPLINE. CONSULTANTS SHOULDFAMILIARIZE THEMSELVES WITH ALL CRITERIA NOTES.ENGINEERINGE0STRUCTURALS0INTERIOR DESIGNID0ARCHITECTURALA0E8PROVIDE DATA, TV CABLE, & DUPLEX OUTLET DEDICATED TOTV. MOUNT AT HEIGHT SHOWN ON DRAWING.S7PROVIDE STRUCTURAL SUPPORT IN CEILING FOR MOVABLEPARTITION SYSTEM.S10PROVIDE BLOCKING ABOVE THE CEILING AS REQUIRED FORSPECIALTY PENDANT LIGHTING. REFERENCE THE ID SPECMANUAL FOR LIGHT FIXTURE SPECIFICATION AND WEIGHTINFORMATION.ID20CENTER LIGHT FIXTURE ABOVE TABLE BELOW.ID56CENTER LIGHT FIXTURE ABOVE MENU BOARDS.ID75REFER TO THE ART ARRANGEMENT SECTION IN THE IDSMFOR ARTWORK PLACEMENT AND CONFIGURATION.ID76LM-500 ARTWORK TO BE USED WITH V-329 WALLCOVERING.IF USING V-304, NO ARTWORK IS NEEDED.A89PROVIDE BLOCKING AS REQUIRED FOR SPECIALTYARTWORK.REQUIRED WALL FINISH LEVELS1.ALL WALLS TO RECEIVE VINYL WALL COVERING ARE TOHAVE A LEVEL 3 (MINIMUM) GYPSUM BOARD FINISH.ALLWALLS TO RECEIVE PAINT (OR LIGHT TO MED WEIGHT WALLCOVERING) ARE TO HAVE A LEVEL 4 GYPSUM BOARD FINISH.ALL WALLS TO RECEIVE GLOSS, ENAMEL PAINT, OR MURALSTO HAVE A LEVEL 5 GYPSUM BOARD FINISH.LM-100LM-100LM-100LM-100PTW-012PTW-012PTW-012PTW-012PTW-012LM-232LM-232LM-232LM-405LM-200LM-230LM-200LM-200LM-230PTW-012V-329LM-606LM-606MLM-244LM-244LM-0026'-10 3/4"TB-002OR V-330OR V-330OR V-330OR V-330OR V-330OR V-329SCALE: 1/4" = 1'-0"1LOBBY SOUTH ELEVATIONPTW-012PTW-012PTW-012PTW-012LM-216RLM-300LM-300BLM-244LM-212LM-244LM-300LM-300BLM-216LLM-100TYP.PTW-012SP-002V-329A89LM-220PLM-219PLM-220PLM-219PLM-500LM-860LM-411LM-411ID20ID20TB-002LM-002OR V-330OR V-330OR V-330OR V-330OR V-330S10S10SCALE: 1/4" = 1'-0"2LOBBY NORTH ELEVATIONOPEN TOBEYONDOPEN TOCORRIDORGL-003PTW-01213A620V-301V-301V-330GL-005GL-005SP-001SP-001SP-001GL-005LM-605LM-605MGL-002V-301LM-225LM-2116' - 0"EQEQS7E8GL-005SP-001LM-002SP-001SP-001SP-001LM-860LM-203LM-203WTR-001MT-005MT-005MT-005WP-002S13LM-201LM-408LM-408LM-408ID56MT-005LM-411LM-411LM-411ID20ID20TB-002ML-004S10S10S10SCALE: 1/4" = 1'-0"3LOBBY WEST ELEVATIONOPEN TOCORRIDOROPEN TOBEYONDPTW-012SP-001SP-002SP-001V-329 or V-304SP-001A89LM-500WTR-001SP-001OR V-330ID75ID76SCALE: 1/4" = 1'-0"4LOBBY EAST ELEVATIONSP-001LM-002V-301V-301WTR-001LA-007TB-002TB-002SCALE: 1/4" = 1'-0"9FOOD PREP ENTRY ELEVATION9A620LM-407/LM-407BCT-003CT-003PTW-012V-301SCALE: 1/4" = 1'-0"5ELEVATION @ COLUMNCARMEL, INThese drawings are the property of Maust Architectural Services and may not be reprinted, copied
or reused in any manner without the expressed written consent of Maust Architectural Services.
GENERAL NOTESMAUST
ARCHITECTURAL
SERVICES
GOSHEN, INDIANA 46526
PHONE (574) 537-8500
FAX (574) 537-0808
* Architects
* Planners
* Consultants
DIVISION OF
112 NORTH MAIN STREET
* Construction Mgmt.
* Rule 5 and MS4 Filing
L.E.M., INC.DATE :JOB NO. :SHEET:MAS-21-123NAME:REVISIONS :-ALTHOUGH DRAWINGS ARE DRAWN TO SCALE, THE
ACCURACY OF THE DRAWING CANNOT BE
GUARANTEED DUE TO DISCREPANCIES IN THE METHODS
OF REPRODUCTION. DIMENSIONS SHOULD BE DERIVED
FROM DIMENSIONED PLANS.
-ALL DIMENSIONS, ROUGH OPENING SIZES, AND
ELEVATION MARKERS MUST BE FIELD VERIFIED BY THE
GENERAL CONTRACTOR. MAUST ARCHITECTURAL
SERVICES SHALL NOT BE HELD RESPONSIBLE FOR ANY
DIMENSIONAL DISCREPANCIES WHICH HAVE NOT BEEN
BROUGHT TO THEIR ATTENTION PRIOR TO
CONSTRUCTION.COURTYARDBY MARRIOTT04-07-21SHEET SIZE 24x36A161LOBBY AREA ELEVATIONS