Loading...
HomeMy WebLinkAboutC101 STORMWATER POLLUSION PREVENTION PLAN PHASE 2131ST STREETE(A)WWWW W W W W W W W W W W W W WWWWWWWWWWWWW W W W W W W W WDD D D D D D D D DDD DDDDDDDDDDDDDDDDDDDDDDDDD DDDDDDDDDDDDD D D*IPIPIPIPIPIPIPIPSD SD SD SD SD SDSF SF SF SF SF SF SF SF SF SFSFSFSFSFSF SFSFSFSFSFSFSFSFSFSFSFWATER QUALITYHYDRO INTERNATIONAL5' DIAMETER FIRST DEFENSECONTACT PERSON FOR EROSIONCONTROL & SEDIMENT PRACTICESWEIHE ENGINEERS, INC.10505 N. COLLEGE AVE.INDIANAPOLIS, IN 46268TELEPHONE: (317) 846-6611FAX: (317) 843-0546EMAIL: PARKERF@WEIHE.NETCONTACT PERSON: FRED PARKER, CPESC-WARNING-THIS PLAN TO BE USED FOR EROSION CONTROLPURPOSES ONLY. ADDITIONAL EROSIONCONTROL MEASURES MAY BE REQUIRED IN THEFIELD BY THE INSPECTOR.-NOTE- THIS PLAN INDICATES EROSION CONTROLMEASURES REQUIRED AFTER SOIL STRIPPINGAND PAD BUILDING HAS TAKEN PLACE.COORDINATE WITH DEVELOPER FORMEASURES REQUIRED UNTIL PROPERTYTURNED OVER FOR DEVELOPMENT.COORDINATE WITH SOIL CONSERVATIONDISTRICT REPRESENTATIVE FOR ANY OTHERMEASURES REQUIRED DUE TO SITECONDITIONS.DISTURBED ACREAGE= 1.98± AC.LAND DESCRIPTIONLOT 3 OF CMC PROPERTIES SUBDIVISION SECTION 2 RECORDED AS INSTRUMENTNUMBER 2006057917 IN THE OFFICE OF THE RECORDER OF HAMILTON COUNTY.BENCHMARK INFORMATIONVERTICAL DATUM: NAVD 88 (GEOID 12B)SITE TEMPORARY BENCHMARKS (TBM) ORIGIN DERIVED FROM TRIMBLE VRS NOWNETWORK GPS REFERENCE STATION IN_HAMCTBM 500:A 5/8 INCH DIAMETER REBAR WITH RED CAP STAMPED "SCHNEIDER RANDOMPOINT" LOCATED APPROXIMATELY CENTER OF SUBJECT PROPERTY.ELEVATION 871.94 (NAVD 88)TBM 501:MAG. NAIL & WASHER STAMPED "SCHNEIDER RANDOM POINT" SET IN TOP OF CURB,34 FEET SOUTHEAST OF NORTHWEST CORNER OF THE SUBJECT PROPERTY.ELEVATION 871.51 (NAVD 88)109a b c d8 76e f g h 1098765432Part of the NW/4 of Section 26, Township 18 North, Range 3 East, Clay Township, Hamilton County, Indiana1PREPARED FOR:PROJECT NO.SHEET NO.a b c d 5432e 1f h SUBMITTAL TO CITY OF CARMEL 03.20.2024 TAS RESUBMITTAL TO CITY OF CARMEL 05.15.2024 TAS RESUBMITTAL TO CITY OF CARMEL 06.04.2024 TAS g ALLAN H. WEIHE, P.E., L.S. - FOUNDER 10505 N. College Avenue Indianapolis, Indiana 46280 weihe.net Build with confidence.SM ENGINEERS 317 | 846 - 6611 800 | 452 - 6408 317 | 843 - 0546 fax W E I H E Land Surveying | Civil Engineering Landscape Architecture06/13/2024PROJECT NO.:REVISIONS AND ISSUES DATE BY DWG NAME: DESIGNED BY: DRAWN BY: CHECKED BY: DATE:WSNEKnow what'sbelow.before you dig.CallRPLAN CERTIFICATE NOTE:ORIGINAL ALTA, TOPOGRAPHY, UTILITIES, STORMSEWERS AND ALL OTHER EXISTING CONDITIONS ITEMSWERE PREPARED BY SCHNEIDER CORP., JOB# 11453.001, DATED: 01/11/2019STEVEN SCOTT RUCKER P.E. 11300279A P P R O V A L P E N D I N G N O T F O R C O N S T R U C T I O N RESUBMITTAL TO CITY OF CARMEL 06.13.2024 TASSWPPP PHASE 2 LEGEND- INLET PROTECTION - ONLY COMPLETELY BELOW THE GRATEPROTECTION IS ALLOWED IN THE PUBLIC RIGHT-OF-WAY-STONE FOR ASPHALT PAVEMENT- LIMITS OF DISTURBANCE (CONSTRUCTION LIMITS)- SILT FENCE- INSTALL STRAW WATTLES (GRASS AREA) OR SILT DIKES(PAVEMENT AREA) AS SHOWN. CONTRACTOR TO ADDADDITIONAL MEASURES AS CONSTRUCTION PHASING ANDSITE CONDITIONS DICTATE- SITE DISCHARGE POINTIP*DLINE TYPESUNDERGROUND GASUNDERGROUND WATERAERIAL ELECTRICUNDERGROUND ELECTRICUNDERGROUND COMMUNICATIONSRIGHT OF WAY LINEBUILDING SETBACK LINEBOUNDARY LINEFLOW LINEGGGWWE(A)E(A)EEECCCSECTION LINEINDEX CONTOURINTERMEDIATE CONTOURSANITARY SEWERSTORM SEWERSFSDEXISTING INDEX CONTOUREXISTING INTERMEDIATE CONTOUREXISTING SANITARY SEWEREXISTING STORM SEWERW220592-C101 swppp2 C101STORMWATER POLLUSION PREVENTION PLAN PHASE 2W22.0592TAS W22.0592 03.20.2024 SSR SSR COURTYARD BY MARRIOTT 13285 ILLINOIS ST., CARMEL, IN 46032 SITE PREPARATION / SWPPP PHASE 1 NOTESEXISTING MONUMENT (CONTRACTOR TO PROTECT AND PRESERVE THEM)1