HomeMy WebLinkAboutDumpster enclosure26'-0"12'-0 3/8"12'-0 3/4"7 5/8"7 5/8"16'-0" 14'-8 3/4" 7 5/8"7 5/8" 16'-0"15'-4 3/8"7 5/8"26'-0"8 3/8"7 5/8"8'-4"3'-4"12'-4"4"7 5/8"8'-0" 9'-4" 9'-4"8" CMU FOUNDATION AND EXTERIORWALL WITH (1) #5 REBAR AT 4'-0"O.C. AND SOLID GROUT - LAP ALLREBARS ACCORDING TO CODE8" CMU BOND BEAM WITH (2)#5 REBARS AT BOTTOMDOUBLE 2x10 BAND BOARDS WITHEXPANSION ANCHORS AT 2'-0" O.C.STAGGERED2x10 ROOF JOISTS AT 16" O.C.WITH JOIST HANGERS ATBOTH ENDSCONTINUOUS PRESSURETREATED 2x12 PLATEANCHORED INTO CMU BLOCKCONTINUOUS HORIZONTALREINFORCEMENT AT 16" O.C.VERTICALLYCONTINUOUS CONCRETE FOOTINGWITH (2) #5 CONTINUOUS REBARSAT BOTTOM1'-0"2'-0"CONTINUOUS 1/2" EXPANSIONJOINT AROUND CONCRETE SLABPERIMETER (TYPICAL)3/4" OSB ROOF DECKINGWITH "H" CLIPSROOFING MEMBRANE ON MINIMUM1 1/2" RIGID INSULATION4" REINFORCED CONCRETESLAB WITH 6"x6" 10/10W.W.M. ON CHAIRSEXTEND ROOFING MEMBRANEUP AND OVER PARAPET WALLPROVIDE TERMINATIONBARS WHERE REQUIRED8" REINFORCED CONCRETESLAB (SEE CIVIL DRAWINGSFOR DETAILS)3'-10" (TYPICAL) 3'-2" (TYPICAL)6" DIAMETER GALVANIZED STEELPIPE BOLLARD FILLED WITHCONCRETE AND TOPPED WITH AHALF MOON CONCRETE CAP (FIELDPAINT)1'-6"CONCRETE COLD JOINT ATALL CONCRETE BOLLARDSCONTINUOUS 1/2" EXPANSIONJOINT AROUND CONCRETE SLABPERIMETER (TYPICAL)PREFORMED AND PREFINISHEDALUMINUM DOWN SPOUT ANDGUTTER SYSTEM (TYPICAL)CONTINUOUS METAL FLASHINGDRIP EDGECONTINUOUS METAL COPING(MATCH EIFS FINISH COLOR)PAINT INTERIOR CMU SURFACESAND METAL PIPE BOLLARDS(TYPICAL)8" REINFORCED CONCRETESLAB (SEE CIVILDRAWINGS FOR DETAILS)20'-0" (MINIMUM)MATCH GATE OPENING PLAN WIDTHELEV. 100'-0"T/FINISH FLOORELEV. 109'-5 1/2"T/WALLELEV. 96'-4"BTM/FOOTING3'-8"9'-5 1/2"PAINT ALL INTERIOR CMUSURFACES AND METAL PIPEBOLLARDS (TYPICAL)8" REINFORCED CONCRETESLAB (SEE CIVILDRAWINGS FOR DETAILS)6'-0"YARD HYDRANT WITH SHUTOFF BELOW FROST DEPTH(TYPICAL)3'-0"6'-0"EQUALEQUALCLCLCLCL6'-0"3'-0"CLCL9"2'-0"CLCL 2'-0"CL9"CL9"CL9"CLDUMPSTER (TYPICAL)CONCRETE CONTROL JOINTS(TYPICAL)8"CL 8"CL4"HEAVY DUTY GALVANIZEDFENCE POSTS WITH GALVANIZEDMETAL GATE FRAMING COVEREDWITH SOLID VINYL FENCEBOARDS8" CMU FOUNDATION ANDEXTERIOR WALL WITH (1)#5 REBAR AT 4'-0" O.C.AND SOLID GROUT - LAPALL REBARS ACCORDINGTO CODECONTINUOUS CONCRETEFOOTING WITH (2) #5CONTINUOUS REBARS ATBOTTOM4" REINFORCED CONCRETESLAB WITH 6"x6" 10/10W.W.M. ON CHAIRSCONTINUOUS CONCRETEFOOTING WITH (2) #5CONTINUOUS REBARS ATBOTTOMSLOPESLOPE SLOPE(2) <3 1/2" x 3 1/2" x 5/16"STEEL ANGLES WITH 6" ENDBEARING AT EACH ENDSEALED CONCRETEFLOOR (TYPICAL)18" DIAMETER STEEL PIPECONCRETE FOOTING(TYPICAL)ELEV. 100'-0"T/FINISH FLOORELEV. 109'-5 1/2"T/WALL9'-5 1/2"CONTINUOUS METAL COPING(MATCH EIFS FINISH COLOR)8" CMU FOUNDATION AND EXTERIORWALL WITH (1) #5 REBAR AT 4'-0"O.C. AND SOLID GROUT - LAP ALLREBARS ACCORDING TO CODEELEV. 100'-0"T/FINISH FLOORELEV. 109'-5 1/2"T/WALL9'-5 1/2"PROVIDE DROP PIN LOCKS(TYPICAL)SCALE: 1/2" = 1'-0"1DUMPSTER PLAN(SEE SITE PLAN)SCALE: 1/2" = 1'-0"3DUMPSTER ELEVATIONGATE ELEVATIONSCALE: 1/2" = 1'-0"4DUMPSTER SECTIONSLOPESLOPECONTINUOUS METAL COPING(MATCH EIFS FINISH COLOR)8" CMU FOUNDATION AND EXTERIORWALL WITH (1) #5 REBAR AT 4'-0"O.C. AND SOLID GROUT - LAP ALLREBARS ACCORDING TO CODESCALE: 1/2" = 1'-0"2DUMPSTER ELEVATIONTYPICAL SIDE ELEVATION4A410SLOPE 2A4103A410MASONRY (MATCH HOTEL FIRSTFLOOR MASONRY DESIGN ANDPATTERN)CONTINUOUS METAL FLASHINGAND WEEP HOLES (TYPICAL)MASONRY (MATCH HOTELFIRST FLOOR MASONRYDESIGN AND PATTERN)MASONRY (MATCH HOTEL FIRSTFLOOR MASONRY DESIGN ANDPATTERN)MASONRY (MATCH HOTEL FIRSTFLOOR MASONRY DESIGN ANDPATTERN)ALL CMU IN STORAGE ROOM TOHAVE DRI-BLOCK ADDITIVE ANDTO BE LEFT UNPAINTED6" DIAMETER GALVANIZEDSTEEL PIPE BOLLARDFILLED WITH CONCRETEAND TOPPED WITH A HALFMOON CONCRETE CAP(FIELD PAINT)HEAVY DUTY GALVANIZEDFENCE POSTS WITHGALVANIZED METAL GATEFRAMING COVERED WITHSOLID VINYL FENCE BOARDS6" DIAMETER GALVANIZEDSTEEL PIPE BOLLARD FILLEDWITH CONCRETE AND TOPPEDWITH A HALF MOONCONCRETE CAP (FIELD PAINT)PROVIDE (1) FLURESCENTSTRIP LIGHT WITH SWITCHAND (2) GFI OUTLETSS2 x 1 0 R O O F J O I S T S A T 1 6 " O . C .WIT H J O I S T H A N G E R S A T B O T H E N D SGALVANIZED HOLLOW METALDOOR AND FRAME WITH HARDWARESET T-16 (SEE SHEET A702)GALVANIZED HOLLOW METALDOOR AND FRAME WITH HARDWARESET T-16 (SEE SHEET A702)A410DUMPSTER PLANS,SECTIONS, AND ELEVATIONSCARMEL, INThese drawings are the property of Maust Architectural Services and may not be reprinted, copied or reused in any manner without the expressed written consent of Maust Architectural Services. GENERAL NOTESMAUST ARCHITECTURAL SERVICES GOSHEN, INDIANA 46526 PHONE (574) 537-8500 FAX (574) 537-0808 * Architects * Planners * Consultants DIVISION OF 112 NORTH MAIN STREET * Construction Mgmt. * Rule 5 and MS4 Filing L.E.M., INC.DATE :JOB NO. :SHEET:MAS-21-123NAME:REVISIONS :-ALTHOUGH DRAWINGS ARE DRAWN TO SCALE, THE ACCURACY OF THE DRAWING CANNOT BE GUARANTEED DUE TO DISCREPANCIES IN THE METHODS OF REPRODUCTION. DIMENSIONS SHOULD BE DERIVED FROM DIMENSIONED PLANS. -ALL DIMENSIONS, ROUGH OPENING SIZES, AND ELEVATION MARKERS MUST BE FIELD VERIFIED BY THE GENERAL CONTRACTOR. MAUST ARCHITECTURAL SERVICES SHALL NOT BE HELD RESPONSIBLE FOR ANY DIMENSIONAL DISCREPANCIES WHICH HAVE NOT BEEN BROUGHT TO THEIR ATTENTION PRIOR TO CONSTRUCTION.COURTYARDBY MARRIOTT04-07-21SHEET SIZE 24x36