Loading...
HomeMy WebLinkAboutSPP200 - Topographic Survey'OST FOR GATE ).5' N. OF LINE 775 18" RCP EXISTING INVERT—\ IF-774.24 GRASS 24" RCP EXISTING INVERT IE-774.27 ASSUMED NORTH SCALE 1" = 30' 30 0 15 30 SHEET 2 AlIIInvaI►I0-101VA,F_r0•)111LI With regard to utility lines shown hereon, source information from plans and markings, where provided, was combined with observed evidence of utilities to develop a view of those underground utilities. However, lacking excavation, the exact location of underground features cannot be accurately, completely and reliably depicted. Where additional or more detailed information is required, the client is advised that excavation may be necessary. Member utilities are as follows: Call —in Ticket No.2308141314 dated 08/14/2023. COMCAST CABLE (INDIANAPOLIS) CABLE TV DUKE ENERGY ELECTRIC CENTERPOINT ENERGY (NORTH) GAS METRO FIBERNET, LLC FIBER OPTIC CITY OF CARMEL STREET DEPARTMENT TRAFFIC LIGHTS CARMEL UTILITIES SEWER, WATER CHARTER COMMUNICATIONS MARION CABLE TV, FIBER OPTIC CITY OF NOBLESVILLE SEWER EVERSTREAM, LLC (SOUTH) COMMUNICATIONS, FIBER OPTIC CHARTER COMMUNICATIONS INDIANAPOLIS CABLE TV, FIBER OPTIC AT&T — DISTRIBUTION COMMUNICATIONS 1&N11A1qP05FLW 17.1' N. Of (INST. 9 Il BENCHMARK INFORMATION: VICINITY MA Originating Benchmark: The horizontal and vertical location data shown on this survey are based upon a positional solution derived from Global Positioning System (GPS) observations. The coordinate values shown are in the Indiana State Plane Coordinate System (East Zone) reference to the 1983 North American Datum utilizing the Continuously Operating Reference Stations (CORS) adjustment as determined by NGS (NAD 83 (CORS 96)(EPOCH 2002.0000) and reported on the 1988 North American Vertical Datum (NAVD88). This orthometric elevation was computed using Geoid18. CP 100 — N:1727799 E:214435 Elev: 780.31' 5/8" Rebar w/ Schneider Control Cap CP 217 — N:1727332 E:214183 Elev: 781.21' 5/8" Rebar w/ Schneider Control Cap CP 219 — N:1727312 E:214729 Elev: 780.28' Mag Nail in Concrete SPECIAL NOTES: 1. Any building dimensions shown on this survey are best as collected in the field. Buildings may not be closed figures due to the types of construction materials used and plumbness of walls measured. 2. This drawing is not intended to be represented as a retracement or original boundary survey, a route survey, or a Surveyor's Location Report. Any boundary lines shown are for informational purposes only and are excluded from the certification. CERTIFICATE OF SURVEY: I, the undersigned, hereby certify that to the best of my professional knowledge and belief the within plat represents a topographic survey of the real estate shown or described hereon. The nature, size and location of utilities shown on this plat are per plans and/or locations provided by the respective utility companies or their representatives together with field observation as further noted hereon. The topographic data was gathered using standard radial surveying techniques with an electronic total station and data collector and/or using a Global Positioning System (GPS). Elevations on hard surfaces or structures are accurate to within 0.05 feet, elevations on natural surfaces are accurate to within 0.1 feet. Contours are plotted based upon interpolation of spot elevations shown hereon and are accurate to generally within one half contour interval. The field data was collected on August 29, 2023. ♦```����t,\A —-------------------------- _ o: , orman H. Hiselman, PS =zc N O • Z= egistered Land Surveyor #LS80040461 = SO461 nhiselman@schneidergeomatics.com STATE OF September 9, 2023 <1; A;O �..DIANP•yp��� $UR`1 `��♦` ��numn�a N'v Ilr r3nule Elr pelican rl .t•• 7A CURB 4 co � 20037 II oQ 3 I N 0 20039 I I IRAs� ' \ 00 II P X t Sa?pi ii D's 3 SITE - Wxli:er Wa N J. rrr -Puffin Pi — - Warbler Wary r F�J;"��' F ,vCfalrurr Pi MEET 2 a G lauuua Ur z u53mz ❑f v hranah�s Wzv - nrau•rfin, ol pPacl�fir!�rr -. L EGF�N 7D ®®® INLET OR CATCH BASIN 0 0 STORM & SEWER MANHOLE TELEPHONE MANHOLE • MANHOLE 0 ACCESS COVER TO TRAFFIC MANHOLE 0 WATER MANHOLE 'COCLEANOUT AREA LIGHT ------1 UTILITY POLE WITH GUY WIRE �R UTILITY POLE WITH RISER O TRAFFIC POLE 1.1J UTILITY PEDESTAL OE ELECTRIC METER cu CONDITIONING UNIT -►o- UTILITY VALVE ® ELECTRIC TRANSFORMER 'C' HYDRANT O WELL WATER VALVE OW WATER METER GAS VALVE OG GAS METER SIGNS ® MAILBOX d TREE, SHRUB SOIL BORING BENCHMARK (TBM) CONTROL POINT O MONUMENT FOUND O MONUMENT SET O SET 5/8" REBAR WITH YELLOW CAP OR MAGNAIL WITH WASHER STAMPED "SCHNEIDER — FIRM #0001" (UNLESS OTHERWISE NOTED Z ROW MONUMENT ROW OVERHEAD UTILITY LINES TV UNDERGROUND TELEVISION E UNDERGROUND ELECTRIC T UNDERGROUND TELEPHONE FO UNDERGROUND FIBER OPTIC F UNDERGROUND FORCE MAIN G UNDERGROUND GAS LINE W UNDERGROUND WATER LINE _ = UNDERGROUND STORM SEWER UNDERGROUND SANITARY SEWER EDGE OF WOODS X X X FENCE LINE FLOW LINE Schneider GEOMATICS Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216-1037 Telephone: 317.826.7100 www.schneidergeomatics.com C o � WF4 0 CQ E­ F4 En W Q Hti a W W cc o W� m W N C> W ­:� O o c�-�'ti ^' EU 0-�)z O P_ O O � z Q z o o Q o I— U w Z � z CC d J U DATE: PROJECT NO On/05/202�J 17226 DRAWN BY: CHECKED BY: NMG NHH REVISIONS: DRAWING FILES: T: \17K\17226\CAD\17226_S.DWG SHFFT NO.: 2