HomeMy WebLinkAboutS-10 Amend S-3 Regulating Soil Pike, Backfill, etc.
';;0
. .
ORDINANCE NO. S - ..l1J..
~
AN ORDINANCE AMENDING ORDINANCE NO. S-3
REGULATING TYPE OF SOIL PIPE, BACKFILL
AND CONNECTING JOINTS AND ESTABLISHING
SPECIFICATIONS THEREFOR PERTAINING TO
PUBLIC AND PRIVATE SEWl:,RS AND DRAINS
WHICH ARE USED IN THE DISCHARGE OF WATERS
AND WASTES INTO THE PUBLIC SEWER SYSTEM
OF THE TOWN OF CARMEL, INDIANA
BE IT ORDAINED BY THE BOARn OF TRUSTEES OF THE TOWN OF CARMEL,
INDIANA:
1) SECTION FOUR (4) (fl of Ordinance No. 5-3 be and the same
is hereby deleted and in its place .and stead the following is
inserted:
"The building sewer shall be cast iron soil pipe meeting
current ASTM specifications or the Department of Commerce
Commercial Standards for extra heavy cast iron soil pipe
and fittings: or, Vitrified Clay Pipe ASTM specification
(Designa'tion C 200-65T).
All Joints and connections shall be fitted with factory
made Resilient Compression Joints meeting the ASTM
specifications for vitrified clay pipe joints having
resilient properties (Designation C 425-64).
A5TM C 425-64 joint types I,
pipe diameters through 12".
12", only joint Types II and
II, & III are acceptable for
For pipe diameters larger than
III shall be used.
Instalation shall conform to ASTM "Installing Vitrified
Clay Sewer Pipe" (Designation C 12-64)."
2) SECTION FOUR (4) (j) of Ordinance No. 5-3 be and the
.0. .~
same is hereby deleted and in its place and stead the following is
inserted:
"All excavations required for the installations of a building
sewer shall be open trench work unless otherwise approved by the said
Inspector. Pipe laying and backfill shall be performed ih accordance
with ASTM specHication (Designation Cl2-64) EXCEPT that no backfill
.shall be placed until the work has been inspected by the inspector
or his representative."
3) SECTION FOUR (4) (k) of Ordinance No. S-3 be and the same
is hereby deleted and in'its place and stead the following is inserted:
"All joints and connections shall be made gas tight and water
tight. Cast iron pipe joints shall be firmly packed with oakum' '.
or hemp and filled with molten lead; Federal Specification QQ-L-156
not less than one (1) inch deep. Lead shall be run in one pouring
and calked tight. No peint, varnish or other coatings shall be
permitted on the jointed or jointing material until after the
joint has been tested and approved. All joints in vitrified .
clay pipe or between such pipe and metals shall be ASTM ,~
specification C 425-64~ Other jointing materials and methods;;(R2.
may be used ONLY by approval of the said Inspector" d
, ,
,
.
,
4) . All other parts and provisions of Ordinance No. S-3
shall remain unchanged and in full force and effect.
5) This ordinance shall be in full force and effect from
and after its passage .and publication as provided by law.
ADOPTED BY THE BOARD OF TRUSTEES OF THE TOWN OF CARMEL,
INDIANA THIS~..4 DAY OF t2;J , 1967.
Pres ent
ATTEST:
1 :
, '