HomeMy WebLinkAboutC010.0.28 - Perimeter Protection Silt Fence Detail4"
Post
Silt Fence
PLAN VIEW
JOINT DETAIL
SECTION A-A
Temporary Geotextile
Flow
Post
Compacted Soil
Ground Line
Roadway
Silt Fence
Fill Slope
Roadway
Fill Slope
Silt Fence
A
Channel
1
6'-0" (max.)(min.)1'-6"(max.)3'-0"6' (typ.)
or Wood Post
Metal, Synthetic,A
PLACEMENT WITH
CHANNEL IN RIGHT OF WAY
PLACEMENT
RELATIVE TO RIGHT-OF-WAY LINE
R/W Line
R/W Line
ELEVATION
10' (min.) From Toe of Slope
E 205-TECD-11
INDIANA DEPARTMENT OF TRANSPORTATION
STANDARD DRAWING NO.
DATECHIEF ENGINEER
DATEDESIGN STANDARDS ENGINEER
Filter Sock shall be used instead of silt fence at or below Q .3.
Additional post depth or tiebacks may be required in unstable soils
The spacing of the tiebacks shall equal the spacing of the posts. 2.
be placed as close as possible to the edge of construction limits.
Dimensions will vary based on right-of-way availability. Silt fence shall 1
NOTES:
SEPTEMBER 2019
100
SILT FENCE
PERIMETER PROTECTION,8" (min.)5/2/2019
5/31/2019
Attachment E