Loading...
HomeMy WebLinkAboutDink House CoverCOURT 6 32'x57'-6" COURT 7 32'x57'-6" COURT 8 32'x57'-6" COURT 1 32'x61' COURT 2 32'x61' COURT 3 32'x61' COURT 4 32'x61' COURT 5 32'x61' DINK COURT 11'x20' STORAGE BABY STUDIO STUDIO 4 WAITING ROOM OFFICE STUDIO 1 STUDIO 2 RECEPTION STORAGE LOCKERS - WITH PLASTIC LAMINATE TOP - 12" WIDE - 48 SHOWN BEVERAGE VENDING SNACK VENDING COUNTER W/ FREEZERBELOW BEERCART SNACK VENDING COUNTER W/ REFRIGERATORBELOW FUTURE FRIDGE PRO DESK PROSHOPSTORAGEOFFICE STORAGEPRINTERADACOUNTERDESKPOSELEC / IT 160 SF 3'-6" OF 24"STORAGE7'-0" OF 24" STORAGE7'-6" OF 24"STORAGE3'-0" OF 24"STORAGE IT EQUIPMENT / SECURITY / EXISTINGELECTRICAL5'-0" OF 24"STORAGEDie Repair 7 '5""X3 'Power Box 14'X5 ' LAB 40' X 24' MAINT 41' X 42' LATHE FAB TABLE MILLDRILLCABINETSTEEL RACKS. GRINDERBOLT BINSCABINETBOLT BINS48'-4"37'-2"12'-2" THE DINK HOUSE - PICKLEBALL FACILITY TENANT BUILD OUT 201 WEST CARMEL DRIVE CARMEL, INDIANA 46032 existing sprinkled building LIFE SAFETY NOTES OVERALL BUILDING PLAN - FIRST FLOOR NTS VICINITY MAP A000 COVER SHEET AND GENERAL PROJECT NOTES A001 LIFE SAFETY PLANS A002 VARIANCE AND CHAPTER 34 INFORMATION A003 VARIANCE AND CHAPTER 34 INFORMATION A100 ENTRY DETAILS A200 ARCHITECTURAL FLOOR PLANS A201 ENLARGED PLAN / INTERIOR ELEVATIONS A202 REFLECTED CEILING PLAN S2.0 COLUMN PLAN LAYOUT AND SPECIFICATION S2.1 COLUMN PLAN LAYOUT AND SPECIFICATION E100 LIGHTING PLANS DRAWING INDEX A000 life safety / notes A. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE. B. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BULIDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK. C. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK. D. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS. NOTED DIMENSIONS TAKE PRECEDENCE. E. VERIFY EXISITNG CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SODA. F. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE. G. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURING HOLIDAYS. OWNER RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION IS DEEMED TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS. H. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME. THE CONTRACTOR SHALL COOORDINATE THE PROJECTS SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER, TENANT, AND SODA WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE. THE OWNER, TENANT, OR DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTORS FAILURE TO COMMUNICATE MATERIAL LEAD TIMES. I. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION. J. SODA SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR A CONTRACTORS CONSTRUCTION MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES. K. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT. L. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD AN AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING RESTROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS. M. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHT FIXTURES AS INDICATED ON THE CEILING PLAN). N. SODA IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE. O. PROVIDE FIRE-TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC. GENERAL PROJECT NOTES P. EXPEDITE PREPARARION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATING AND DELIVERY OF MATERIALS AND EQUIPMENT. Q. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. R. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS AND CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. S. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM WALLBOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS. T. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE FOR FINISH. U. WHEN REQUIRED BY STATE BUILDING CODE, THE CONTRACTOR(S) SHALL PROVIDE DESIGN/BUILD DRAWINGS FOR MECHANICAL, ELECTRICAL, PLUMBING, OR FIRE SUPPRESSION. DRAWINGS SHALL BE CERTIFIED BY A LICENSED ENGINEER AND SUBMITTED BY THE CONTRACTOR FOR STATE DESIGN REVIEW. V. ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRCUTIONS. W. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES AND EQUIPMENT SHALL BE CLEAN AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCES WORK AND DO NOT LEAK. X. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT. Y. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH FACE TO FACE OF NEW STUD WALL , OR FACE TO FACE OF NEW STUD WALL. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. Z. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT. AA. FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH APPROVED FIRE-RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS. AB. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. AC. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS, ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED. AD. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. North SCOPE OF WORK THE INTENT OF THIS PROJECT IS TO RENOVATE EXISTING VACANT SPACE WHICH WAS PREVIOUSLY INDUSTIAL OCCUPANCY TO ASSEMBLY SPACE TO HOUSE PICKLEBALL RECREATIONAL COURTS WITH NO BLEACHERS - BUILDING HAS BEEN SUBMITTED AND APPROVED FOR VARIANCE UNDER PROJECT NUMBER - 440809. THE FACILITY IS OPEN WITH 4'-0" FENCE DIVIDING COURTS - A SMALL LOUNGE AREA IS INCLUDED WITH SINGLE CHAIR SEATING ALONG EDGE OF COURTS 201 WEST CARMEL DRIVE A.PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. B.THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE ANDTHE INDIANA FIRE CODE AND ALL OTHER APPLICABLE LAWS, CODES, RULES, AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/ FIRE SUPPRESSION SYSTEMS. C.PROVIDE NEW OR RELOCATE EXISTING FIRE SPRINKLER HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK. ARCHITECT: SWANSON OFFICE OF DESIGN + ARCHITECTURE 311 WOODLAND LANE CARMEL, IN 46032 [P] 317.324.8855 TENANT: OWNER: THE DINK HOUSE, LLC 201 WEST CARMEL DRIVE CARMEL IN, 46032 BUILDING CODE: INDIANA BUILDING CODE 2014 (INTERNATIONAL BUILDING CODE 2012 WITH INDIANA AMENDMENTS) MECHANICAL CODE: INDIANA MECHANICAL CODE 2014 (INTERNATIONAL MECHANICAL CODE 2012 WITH INDIANA AMENDMENTS) ELECTRICAL CODE: INDIANA ELECTRICAL CODE 2009 (NATIONAL ELECTRICAL CODE 2008 WITH INDIANA AMENDMENTS) PLUMBING CODE: INDIANA PLUMBING CODE 2012 (INTERNATIONAL PLUMBING CODE 2006) FIRE CODE: INDIANA FIRE CODE 2014 (INTERNATIONAL FIRE CODE 2012 WITH INDIANA AMENDMENTS) ENERGY CODE: INDIANA ENERGY CONSERVATION CODE 2010 (ASHRAE 90.1-2007 WITH INDIANA AMENDMENTS) FUEL GAS CODE: INDIANA FUEL GAS CODE 2014 (INTERNATIONAL FUEL GAS CODE 2006 WITH INDIANA AMENDMENTS) ACCESSIBILITY CODE: INDIANA BUILDING CODE 2014, CHAPTER 11 ICC A117.1 ACCESSIBLE USABLE BUILDINGS AND FACILITIES, 2009 EDITION. INDIANA ADMINISTRATIVE CODE 675 IAC 13-2.6-13 APPLICABLE BUILDING CODES THE FOLLOWING CODES AND REGULATIONS ARE CURRENTLY ADOPTED BY THE STATE OF INDIANA AT THE TIME THE BUILDING PERMIT IS APPLIED FOR:ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS & DRAWINGS AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES, A.D.A., AND REGULATIONS OF ALL GOVERNING BODIES INVOLVED. ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR INVOLVED. STRUCTURAL: GERDOM ENGINEERING 13520 SHAKAMAC DRIVE CARMEL, IN 46032 (317) 407-5337 North AREA TO BE ACCESSED BY TENANT THE DINK HOUSE 20,003 S.F. COPYRIGHT: SODA, LLC expressly reserves the common law copyright and other property rights in these plans. These plans are not to be reproduced in any form or manner, nor assigned to any third party, without first obtaining the expressed permission and consent of SODA, LLC.THE DINK HOUSE - PICKLEBALL FACILITY201 WEST CARMEL DRIVECARMEL, IN 46032C COPYRIGHT SODA, LLC . date 01.02.24 PERMIT ISSUE issue Carmel, IN tj@swansonoffice.com t: 317.324.885502.19.24 ADDENDUMNOS N AWSJSAMOHT CRA TCTI AR11800182 T ERED SIGER A N AIDNI H No. STATE OF E FIRE SPRINKLER SYSTEM NOTE: CONTRACTOR TO COORDINATE REWORK OF EXISTING SPRINKLER SYSTEM TO ACCOMODATE NEW ROOM - DESIGN BUILD CONTRACTOR TO SUBMIT DESIGN OF MODIFICATIONS TO STATE OF INDIANA AND CITY OF CARMEL AS REQUIRED JAMES 201 LLC 1030 S RANGELINE RD #300 CARMEL IN 46032 [P] 317-488-7373