Loading...
HomeMy WebLinkAboutA1103 - OVERALL THIRD FLOOR PLANUPUP NW A NW B NW C NW D NW E NW F NW G NW H NW I NW J NW K NW L NW M NW N NW 1 NW 2 NW 3 NW 5 NW 6 NW 7 NW 8 NW 9 NW 10 NW 12 NW 13 C1 2301 B1 2303 B1 2304 A1 2305 B1 2307 A1 2309 B1 2311 A1 2312 B4 2313 B3 2315 B3 2318 B3 2320 B3 2323 S2 2324 B4 2325 A1 2326 B1 2327 A1 2329 B1 2331 A1 2333 B1 2340 A1 2341 B1 2343 A1 2344 B9 2345 A7 2346 A2A 2347 A2 2348 A2A 2350 A2A 2351 A2A 2353 A2 2354 A2A 2356 A2 2358 Stair W1-3 STW1-3 Elevator W1-3 ELVW1-3 Stair W2-3 STW2-3 Elevator W2-3 ELVW2-3 Mech W303 Trash W305 Stair W3-3 STW3-3 Elevator W3-3 ELVW3-3 Mech W311 Mech W313 A4 2314Area AArea BArea B Area D Area DArea CArea C Area A15' - 0"30' - 0"15' - 3"15' - 3"30' - 0"30' - 0"30' - 0"30' - 0"35' - 0"10' - 0 7/8"4' - 10 3/4" 25' - 3" 7' - 0" 52' - 6" 27' - 0" 27' - 0"27' - 0" 27' - 0" 27' - 0" 32' - 6" 25' - 3" 5' - 7 3/4"10' - 8 1/2" 34' - 9" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 15' - 3" 15' - 3" 30' - 0" 15' - 0" 15' - 0" 30' - 0" 24' - 0" 24' - 8" 7' - 8"15' - 0" 30' - 0" 24' - 0" 24' - 8" 7' - 8" Roof Top Deck W314 Bike Storage W315 Pool Equipment W316 Garage W300 Utilities W307 City IT W308 342' - 3"287' - 9" 5' - 1 1/2" 25' - 3" 7' - 0" 52' - 6" 27' - 0" 27' - 0" 27' - 0" 27' - 0" 27' - 0" 32' - 6" 25' - 3" 5' - 1 1/2"342' - 0 3/4"288' - 2 3/4" 225' - 5 3/8"31' - 3 5/8"31' - 0 1/2" - --- - --- General Notes 1. The General Contractor shall verify all conditions at the jobsite. Notify Architect of any deviations from those conditions as they are noted on the drawings. 2. The General Contractor shall coordinate and schedule all work with the Owner. 3. The General Contractor is responsible for compliance with all state and local building codes and government regulatory agencies. 4. The General Contractor is to submit shop drawings, project data, and samples to Owner/Architect for approval prior to fabrication of all millwork and wall finishes. 5. Do not scale any drawings. Any dimensions are to be obtained from the Architect if not noted on the drawings. Refer all questions to the Architect or Engineer on Record. 6. All dimensions are to C.L. of demising wall of units and face of framing. 7. The General Contractor shall keep one set of plans at the jobsite for the specific purpose of recording actual construction conditions. Such project record documents shall be provided to the Owner upon completion of the project. 8. The General Contractor shall verify size, location, and characteristics of all works and equipment supplied by the Owner or others with the manufacturer or supplier prior to the start of the work. 9. The General Contractor shall see that all Subcontractors receive complete working drawings and assume full responsibility for coordination of work. 10. See Enlarged Area Plans for Additional Information. ARCHITECTCLIENTCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS21010 8.1.2023 Permit Set A1103Overall Third FloorPlanMONONSQUARE620 S. Rangeline RoadCarmel, IN 46032Monon SquareAssociates, LLCSCALE: 1/16" = 1'-0"A1103 1 NW Third Floor See sheet A1092 for Garage Plan and Details