Loading...
HomeMy WebLinkAboutA1106 - OVERALL SIXTH FLOOR PLANDN DN UP UP NW A NW B NW C NW D NW E NW F NW G NW H NW I NW J NW K NW L NW M NW N NW 1 NW 2 NW 3 NW 5 NW 6 NW 7 NW 8 NW 9 NW 10 NW 12 NW 13 C1 2601 B1 2603 B1 2604 A1 2608 B1 2610 A1 2612 B1 2614 A1 2615 B4 2616 A4 2617 B3 2618 B3 2621 B3 2623 B3 2626 S2 2627 B4 2628 A1 2629 B1 2630 A1 2632 B1 2634 A1 2636 B1 2640 A1 2641 B1 2643 A1 2644 B9 2645 A7 2646 A2A 2647 A2 2648 A2A 2650 A2A 2651 A2A 2653 A2 2654 A2A 2656 A2 2658 B3 2659 A1 2657 B3 2655 A1 2652 B3 2649 B2 2642 B5 2639 B5 2637 C2 2638 C2 2606 B5 2605 B5 2607 B2 2602 A1 2635 A1 2633 B3 2625 A1 2624 B3 2622 A1 2620 B3 2619 A1 2609 A1 2611 B2 2613 B2 2631 Stair W1-6 STW1-6 Elevator W1-6 ELVW1-6 Stair W2-6 STW2-6 Elevator W2-6 ELVW2-6 Mech W603 Trash W605 Services W613 Services W614 Stair W3-6 STW3-6 Elevator W3-6 ELVW3-6 Mech W61515' - 0"30' - 0"15' - 3"15' - 3"30' - 0"30' - 0"30' - 0"30' - 0"35' - 0"10' - 0 7/8"9' - 2 7/8" 35' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0"15' - 3" 15' - 3" 30' - 0" 15' - 0" 15' - 0" 30' - 0" 24' - 0" 24' - 8" 7' - 8"15' - 0" 30' - 0" 24' - 0" 24' - 8" 7' - 8"342' - 3"287' - 9" 5' - 1 1/2" 25' - 3" 7' - 0" 52' - 6" 27' - 0" 27' - 0" 27' - 0" 27' - 0" 27' - 0" 32' - 6" 25' - 3" 5' - 1 1/2"342' - 1"4' - 10 3/4" 25' - 3" 7' - 0" 52' - 6" 27' - 0" 27' - 0"27' - 0" 27' - 0" 27' - 0" 32' - 6" 25' - 3" 5' - 7 3/4" 288' - 0" 192' - 10 3/8"31' - 0 1/2"63' - 4 1/2" Service - --- - --- General Notes 1. The General Contractor shall verify all conditions at the jobsite. Notify Architect of any deviations from those conditions as they are noted on the drawings. 2. The General Contractor shall coordinate and schedule all work with the Owner. 3. The General Contractor is responsible for compliance with all state and local building codes and government regulatory agencies. 4. The General Contractor is to submit shop drawings, project data, and samples to Owner/Architect for approval prior to fabrication of all millwork and wall finishes. 5. Do not scale any drawings. Any dimensions are to be obtained from the Architect if not noted on the drawings. Refer all questions to the Architect or Engineer on Record. 6. All dimensions are to C.L. of demising wall of units and face of framing. 7. The General Contractor shall keep one set of plans at the jobsite for the specific purpose of recording actual construction conditions. Such project record documents shall be provided to the Owner upon completion of the project. 8. The General Contractor shall verify size, location, and characteristics of all works and equipment supplied by the Owner or others with the manufacturer or supplier prior to the start of the work. 9. The General Contractor shall see that all Subcontractors receive complete working drawings and assume full responsibility for coordination of work. 10. See Enlarged Area Plans for Additional Information. ARCHITECTCLIENTCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS21010 8.1.2023 Permit Set A1106Overall Sixth FloorPlanMONONSQUARE620 S. Rangeline RoadCarmel, IN 46032Monon SquareAssociates, LLCSCALE: 1/16" = 1'-0"A1106 1 NW Sixth Floor