HomeMy WebLinkAboutA1106 - OVERALL SIXTH FLOOR PLANDN
DN
UP
UP
NW
A
NW
B
NW
C
NW
D
NW
E
NW
F
NW
G
NW
H
NW
I
NW
J
NW
K
NW
L
NW
M
NW
N
NW
1
NW
2
NW
3
NW
5
NW
6
NW
7
NW
8
NW
9
NW
10
NW
12
NW
13
C1
2601
B1
2603
B1
2604
A1
2608
B1
2610
A1
2612
B1
2614
A1
2615
B4
2616
A4
2617
B3
2618
B3
2621
B3
2623
B3
2626
S2
2627
B4
2628
A1
2629
B1
2630
A1
2632
B1
2634
A1
2636
B1
2640
A1
2641
B1
2643
A1
2644
B9
2645
A7
2646
A2A
2647
A2
2648
A2A
2650
A2A
2651
A2A
2653
A2
2654
A2A
2656
A2
2658
B3
2659
A1
2657
B3
2655
A1
2652
B3
2649
B2
2642
B5
2639
B5
2637
C2
2638
C2
2606
B5
2605
B5
2607
B2
2602
A1
2635
A1
2633
B3
2625
A1
2624
B3
2622
A1
2620
B3
2619
A1
2609
A1
2611
B2
2613
B2
2631
Stair W1-6
STW1-6
Elevator W1-6
ELVW1-6
Stair W2-6
STW2-6
Elevator W2-6
ELVW2-6
Mech
W603
Trash
W605
Services
W613
Services
W614
Stair W3-6
STW3-6
Elevator W3-6
ELVW3-6
Mech
W61515' - 0"30' - 0"15' - 3"15' - 3"30' - 0"30' - 0"30' - 0"30' - 0"35' - 0"10' - 0 7/8"9' - 2 7/8" 35' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0"15' - 3" 15' - 3" 30' - 0" 15' - 0" 15' - 0" 30' - 0" 24' - 0" 24' - 8" 7' - 8"15' - 0" 30' - 0" 24' - 0" 24' - 8" 7' - 8"342' - 3"287' - 9"
5' - 1 1/2" 25' - 3" 7' - 0" 52' - 6" 27' - 0" 27' - 0" 27' - 0" 27' - 0" 27' - 0" 32' - 6" 25' - 3" 5' - 1 1/2"342' - 1"4' - 10 3/4" 25' - 3" 7' - 0" 52' - 6" 27' - 0" 27' - 0"27' - 0" 27' - 0" 27' - 0" 32' - 6" 25' - 3" 5' - 7 3/4"
288' - 0"
192' - 10 3/8"31' - 0 1/2"63' - 4 1/2"
Service
-
---
-
---
General Notes
1. The General Contractor shall verify
all conditions at the jobsite. Notify
Architect of any deviations from
those conditions as they are noted
on the drawings.
2. The General Contractor shall
coordinate and schedule all work
with the Owner.
3. The General Contractor is
responsible for compliance with all
state and local building codes and
government regulatory agencies.
4. The General Contractor is to
submit shop drawings, project data,
and samples to Owner/Architect for
approval prior to fabrication of all
millwork and wall finishes.
5. Do not scale any drawings. Any
dimensions are to be obtained from
the Architect if not noted on the
drawings. Refer all questions to the
Architect or Engineer on Record.
6. All dimensions are to C.L. of
demising wall of units and face of
framing.
7. The General Contractor shall keep
one set of plans at the jobsite for
the specific purpose of recording
actual construction conditions. Such
project record documents shall be
provided to the Owner upon
completion of the project.
8. The General Contractor shall verify
size, location, and characteristics
of all works and equipment supplied
by the Owner or others with the
manufacturer or supplier prior to
the start of the work.
9. The General Contractor shall see
that all Subcontractors receive
complete working drawings and
assume full responsibility for
coordination of work.
10. See Enlarged Area Plans for
Additional Information. ARCHITECTCLIENTCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS21010
8.1.2023
Permit Set
A1106Overall Sixth FloorPlanMONONSQUARE620 S. Rangeline RoadCarmel, IN 46032Monon SquareAssociates, LLCSCALE: 1/16" = 1'-0"A1106
1 NW Sixth Floor