Loading...
HomeMy WebLinkAboutA2103 - OVERALL THIRD FLOOR PLANUP NE A NE B NE C NE D NE E NE F NE G NE H NE J NE 01 NE 02 NE 03 NE 04 NE 05 A1 1201 A1 1303 B6 1304 A1 1306 Stair E1-3STE1-3B6 1302 B8 1305 A3A 1307 A1 1309 Elec E308 A8 1313 A1 1316 B1 1318 S1 1320 S1 1321 B8 1324 A5 1328 S1 1330 A5 1332 A5 1331 Stair E3-3 STE2-3 Mech E314 A5 1329 S1 1327 A5 1326 B7 1325 A3 1323 S1 1322 A3 1319 B6 1317 A3 1315 B10 1314 C3 1312 A1 1311 A1 1310 A1 1308 Elevator E2-3 ELVE2-3 Elevator E1-3 ELV1-2 MEP E309 Data E313 NE 06 NE 07 NE 08 NE 09 NE 10 28' - 6"19' - 6"28' - 6"28' - 6"27' - 9"14' - 2 3/4"147' - 11 3/4"15' - 5 1/2" 31' - 6" 27' - 0" 31' - 6" 15' - 0" 16' - 2" 19' - 5" 27' - 0" 27' - 0" 15' - 1" 19' - 7" 17' - 3" 11 1/2" 262' - 11" 15' - 5 1/2" 31' - 6" 20' - 11" 67' - 10 1/2"8' - 3" 28' - 6" 19' - 6" 28' - 6"85' - 3 1/8"1' - 3" 19' - 6" 28' - 6"8' - 3" 28' - 6" 3' - 9"41' - 6 1/4"15' - 5 1/2" 27' - 9" 28' - 6" 28' - 6" 19' - 6" 28' - 6"107' - 4 1/2"167' - 11 1/2"31' - 6"15' - 0"16' - 2"19' - 5"27' - 0" 126' - 1 3/8" 64' - 8"69' - 0"19' - 9"Storage E310 18' - 8" 27' - 0" 27' - 0" 30' - 11" 2' - 10 1/2" General Notes 1. The General Contractor shall verify all conditions at the jobsite. Notify Architect of any deviations from those conditions as they are noted on the drawings. 2. The General Contractor shall coordinate and schedule all work with the Owner. 3. The General Contractor is responsible for compliance with all state and local building codes and government regulatory agencies. 4. The General Contractor is to submit shop drawings, project data, and samples to Owner/Architect for approval prior to fabrication of all millwork and wall finishes. 5. Do not scale any drawings. Any dimensions are to be obtained from the Architect if not noted on the drawings. Refer all questions to the Architect or Engineer on Record. 6. All dimensions are to C.L. of demising wall of units and face of framing. 7. The General Contractor shall keep one set of plans at the jobsite for the specific purpose of recording actual construction conditions. Such project record documents shall be provided to the Owner upon completion of the project. 8. The General Contractor shall verify size, location, and characteristics of all works and equipment supplied by the Owner or others with the manufacturer or supplier prior to the start of the work. 9. The General Contractor shall see that all Subcontractors receive complete working drawings and assume full responsibility for coordination of work. 10. See Enlarged Area Plans for Additional Information. ARCHITECTCLIENTCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS21010 8.1.2023 Permit Set A2103Overall Third FloorPlanMONONSQUARE620 S. Rangeline RoadCarmel, IN 46032Monon SquareAssociates, LLCSCALE: 1/16" = 1'-0"A2103 1 NE Overall Third Floor