Loading...
HomeMy WebLinkAboutFrame bracing planSteven Jenison10520 Shelbourne RdCarmel, IN 46032ENG. BY : PSC : DRAWN BY : MTO BY : FBi PROJECT # : SHEET : Rustin S XX Alan S Daniel L 20-2060-00BYDESCRIPTIONNO.DATE12024-06-20Rustin SApproval Set.........CAT WALK DETAIL SCALE: 1" = 1'-0" 2x4 BCT ADDED 2x4 12" x 716" OSB CATWALK TOP VIEW OSB WILL OVERHANG 1.5" IN SOME AREAS DUE TO STAGGER OF 2x4s 101 2" 1'-0"19'-11 1/4"0'-2 1/4"1'-5 1/4"3'-0 3/8"4'-7 5/8"6'-2 3/4"BROWN UNPAINT E D8'-2 3/4"10'-2 3/4"12'-2 3/4"14'-2 3/4"16'-2 3/4"18'-2 3/4"10'-0" 19'-71 2" PURLIN & BCT LAYOUT SCALE: 1/4" = 1'-0" W2 W2 40' 10'4"13 10'4"13 15'3"5 4'10"8 20' 4'8"11 24'8"11 4'8"11 29'7"3 4'10"8 40' 10'4"13 13'7"3 13'7"3 20' 6'4"13 26'4"13 6'4"13 40' 13'7"3 1'6'10"A B C D E F G HIJK L 3.5 12 SS0708(B2) 3X12 4X7 SS0612 10X14(R) SS0612 SS0612 4X7 3X12 SS0708(B2) ATTIC ACCESS ASSEMBLY SCALE: N.T.S. R. O . ( S C H E D U L E O N S H E E T 2 0 0 ) 2x8 SPF #2/BTR STRINGERS FASTENED TO BOTTOM CHORD W/ (2) 10d TOE-NAILS (TYP.)312"36" 2x4 SPF #2/BTR SUPPORT NAILER FASTENED TO THE BOTTOM CHORD W/ (5) 10d NAILS EVENLY SPACED BOX FASTEN TO STRINGERS W/ (4) 10d NAILS (TYP.) PREFABRICATED BOX WITH AJ-13 LEDGE TRIM R.O. ( S C H E D U L E O N S H E E T 2 0 0) PREFAB METAL-CLAD REMOVABLE PANEL (NOT SHOWN) WEST END WIND BRACE LOCATION SCALE: 1/8" = 1'-0"BCT ONLY7-100 1/2"GREEN4'-4 3/8"7-100 1/2"GREEN4'-4 3/8"BCT ONLYEAST END WIND BRACE LOCATION SCALE: 1/8" = 1'-0"BCT ONLY6-96 1/8"RED9'-0 1/8"7-105 3/4"GREEN0'-6 1/2"6-97"RED7'-9 1/2"BCT ONLYSEAL300SHEET TITLE:FRAME/BRACING PLANCOPYRIGHT FBi Buildings, Inc. Q-LYFT ERECTION NOTES: 1.(4) BOLTS PER BEAM CONNECTION 2.1" ANTICIPATED DEFLECTION 3.IF BEAMS CANNOT BE LIFTED TO WITHIN 6" OF BOTTOM OF TRUSS, CONFIRM THAT QUAD WILL NOT HIT ROOF WHEN LIFTING 4.FRAMES MUST BE TIED TOGETHER BEFORE DESCENDING 5.BRACE BUILDING ACCORDING TO BRACING MANUAL AFTER LIFTING OR SEE BRACING PLAN (IF APPLICABLE) 6.INSTALL BCT'S BEFORE LIFTING TRUSS DRAWING SCALE : N.T.S. Q-LYFT FRAME PLAN 2x6 BCT CONNECTOR2x6 BCT CONNECTORBCT BCT BCT10'-0"10'-0"4'-0" Q5 Q1 Q1 Q5 5'-0" **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing,indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ITWBCG: www.itwbcg.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org <b>Lumber</b> <gap/>Top chord: 2x8 SP 2400f-2.0E; Bot chord: 2x8 SP 2400f-2.0E; Webs: 2x4 SP #1; W2 2x6 SP #1; <b>Purlins</b> <gap/>In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 20.00 TC 24 20.00 40.00 BC 120 0.15 39.85 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. <b>Loading</b> <gap/>Truss designed for unbalanced snow loads. <b>Wind</b> <gap/>Wind loads based on MWFRS with additional C&C member design. <gap/>Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL K 3524 /-/-/1382 /1553 /280 L 3524 /-/-/1382 /1553 /- Wind reactions based on MWFRS K Brg Wid = 5.5 Min Req =3.3 (Support) L Brg Wid = 5.5 Min Req =3.3 (Support) Bearings K & L Fcperp = 565psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 5760 -8465 B - C 5158 -7472 C - D 5180 -7271 Chords Tens.Comp. D - E 5181 -7271 E - F 5159 -7472 F - G 5767 -8465 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. A - J 7908 -5378 J - I 5698 -3733 Chords Tens.Comp. I - H 5698 -3733 H - G 7908 -5278 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B - J 1411 -1563 J - D 2074 -1061 Webs Tens.Comp. D - H 2074 -1061 H - F 1411 -1563 Loading Criteria (psf) TCLL:13.00 TCDL: 4.00 BCLL: 0.00 BCDL: 4.00 Des Ld:21.00 NCBCLL:0.00 Soffit: 2.00 Load Duration: 1.15 Spacing: 96.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 2.0 psf BCDL: 2.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.00 ft GCpi: 0.18 Wind Duration: 1.33 Snow Criteria (Pg,Pf in PSF) Pg: 20.0 Ct: 1.1 CAT: II Pf: 13.9 Ce: 0.9 Lu: 23.0 Cs: 1.00 Snow Duration: 1.15 Code / Misc Criteria Bldg Code:IBC 2021 TPI Std:2014 Rep Factors Used: No FT/RT: 10(0)/5(0)/4(0) Plate Type(s): 18SS, WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.371 H 999 240 VERT(TL): 0.590 H 807 240 HORZ(LL): 0.100 G - - HORZ(TL): 0.159 G - - Creep Factor: 2.0 Max TC CSI: 0.633 Max BC CSI: 0.977 Max Web CSI: 0.812 Mfg Specified Camber: VIEW Ver: 23.01.02.0731.18 20-2060-00 Steven Jenison T1 Ply: 1 Qty:7 Wgt: 296.8 lbs SEQN: 3879 / T1 / COMN FROM: MLH DRW: .../...06/19/2024