Loading...
HomeMy WebLinkAboutBedford Falls of Carmel Full Set146TH STREET VAR. WIDTH ROW LOT 64 OWNER: DENISE M. BRAGG LOT 147 LOT 148 LOT 149 LOT 150LOT 13OWNER:CHRISTOPHER S. &SEEMA M. MERNITZLOT 10OWNER: MICHELE L. &FERNANDO MORALESBLOCK COWNER: WESTCHASE HOA, INC.BLOCK B OWNER:WESTCHASE HOA, INC.WESTCHASE SUBDIVISIONINSTRUMENT NO. 200000051957LOT 12OWNER: JEFFREY K. &EVA M. TOMLINSONLOT 11OWNER: CRAIG B. & KELLY J.ROBBINSLOT 9 OWNER: JEFFREY P. & HEATHER L. KECK LOT 8 OWNER: DAVID P. & KRISTAN E. LINTON LOT 65 OWNER: NEIL A. & LYNN K. ZLATNISKI LOT 66 OWNER: GANI, HABIBULLA & YASMIN HAJIRA MOHAMED LOT 67 OWNER: ROBERT A. & LISA M. KNAPP LOT 68 OWNER: RAYMOND E. & ANDREA MULLER LOT 146 OWNER: MICHELLE R. & CHAD E. MOORE LOT 151 OWNER: CHRISTIAN E. & SARA J. GRETHLEIN LOT 165 OWNER: TODD J. DARLAND & TRACY R. WEGMAN-DARLAND LOT 152 OWNER: RONALD J. & JUDITH A. HANSON LOT 153 OWNER: TOMMY TATPONG LUK & SHIRLEY M. CAPPAS WARRANTY DEED BOARD OF COMMISSIONERS OF HAMILTON COUNTY INSTRUMENT NO. 2013066530 BLOCK DOWNER: WESTCHASE HOA, INC.BIRDSONG LANE 146TH STREET QUAIL POINT D R I VE POND 1 26 1 7 8 9 11 12 10 13 28 27 24 25 23 16 17 18 14 3 2 5 4 29 30 31 32 33 34 1920 22 6 21 15BEDFORDFALLS DR .GOWER DRIVE BIRDSONG LANEMITCHEL LANEBEDFORDFALLS DRIVEC.A. A C.A. A C.A. B C.A. A C.A. C C.A. C C001 Title SheetC001TITLE SHEETW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMELNO SCALE PROJECT LOCATION W S N E GENERAL NOTES: 1) THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING, OR VERIFYING THAT ALL PERMITS AND APPROVALS ARE OBTAINED FROM THE RESPECTIVE CITY, COUNTY, AND STATE AGENCIES PRIOR TO STARTING CONSTRUCTION. 2) IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO DETERMINE THE EXACT LOCATIONS OF ALL EXISTING UTILITIES IN THE VICINITY OF THE CONSTRUCTION AREA PRIOR TO STARTING CONSTRUCTION 3) IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO NOTIFY AND COORDINATE CONSTRUCTION WITH ALL RESPECTIVE UTILITIES. 4) ALL QUANTITIES ARE ESTIMATES AND SHALL BE CONFIRMED BY THE BIDDING CONTRACTORS. 5) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29 CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. 6) EXCAVATIONS EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRE A TRENCH SAFETY SYSTEM DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. 7) IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER AND CONTRACTOR TO MAINTAIN QUALITY CONTROL THROUGHOUT THIS PROJECT. 8) TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL STANDARDS. 9) THE ENGINEER AND/OR OWNER DISCLAIM ANY ROLE IN THE CONSTRUCTION MEANS AND METHODS ASSOCIATED WITH THE PROJECT AS SET FORTH IN THESE PLANS. 10) ANY FIELD TILES ENCOUNTERED DURING EXCAVATION SHALL BE REPAIRED AND CONNECTED TO NEW STORM SEWERS AND POSITIVE DRAINAGE PRESERVED. 11) IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO CONFIRM THAT ALL LANDSCAPE REQUIREMENTS ARE MET AND CONFORM TO APPLICABLE LOCAL STANDARDS. 12) A PORTION OF THE SITE DOES LIE IN A SPECIAL FLOOD HAZARD AREA AS ESTABLISHED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY - NATIONAL FLOOD INSURANCE PROGRAM, WHEN PLOTTED BY SCALE ON FLOOD INSURANCE RATE MAP #18057C0206G, DATED NOVEMBER 19, 2014. 13) BEARINGS, DIMENSIONS AND EASEMENTS ARE SHOWN FOR REFERENCE ONLY. SEE RECORD SURVEYS & PLAT FOR EXACT INFORMATION. 14) THIS SITE DOES CONTAIN WETLANDS AS SHOWN ON THE U.S. DEPARTMENT OF THE INTERIOR FISH AND WILDLIFE SERVICE; NOBLESVILLE, INDIANA, NATIONAL WETLANDS INVENTORY MAP. 15) ALL WATER MAINS, HYDRANTS, AND WATER VALVES SHALL BE INSPECTED AND SHALL COMPLY WITH BACKFILL, BEDDING, AND THRUST BLOCK REQUIREMENTS PER CITY OF CARMEL DETAIL SHEETS. SITE MAP W S N E CITY OF CARMEL ENGINEERING ONE CIVIC SQUARE CARMEL, IN 46032 ALEX JORDAN 317-571-2441 TRI-COUNTY REGIONAL SEWER UTILITY 7236 MAYFLOWER PARK DR. ZIONSVILLE, IN 46077 RYAN HARTMAN 317-844-9200 HAMILTON COUNTY SURVEYOR'S OFFICE ONE HAMILTON SQUARE, SUITE 188 HAMILTON COUNTY JUDICIAL CENTER NOBLESVILLE, IN 46060 317-776-8495 SAM CLARK CITY OF CARMEL STREET DEPARTMENT 3400 W. 131ST STREET CARMEL, IN 46074 ERIC RUSSELL 317-733-1204 CARMEL UTILITIES - WATER 760 3RD AVENUE S.W. CARMEL, IN 46032 JOHN DUFFY 317-571-2443 CITY OF CARMEL PLANNING/ZONING DEPTARTMENT 1 CIVIC SQUARE CARMEL, IN 46032 ALEXIA LOPEZ 317-571-2417 SPECTRUM 3030 ROOSEVELT AVENUE INDIANAPOLIS, IN 46218 STEVE CREECH 317-429-6691 CITY OF CARMEL FIRE DEPARTMENT 10701 N. COLLEGE AVENUE INDIANAPOLIS, IN 46280 CHRIS ELLISON 317-571-2600 CITY OF CARMEL CONSULTING ENGINEER CROSSROAD ENGINEERS 3417 S. SHERMAN DR. BEECH GROVE, IN 46107 WILLIE HALL 317-780-1555 VECTREN ENERGY P.O. BOX 1700 NOBLESVILLE, IN 46061 CHAD MILLER 317-776-5590 DUKE ENERGY 16475 SOUTHPARK DRIVE WESTFIELD, IN 46074 JESSI HERRINGTON 317-896-6725 OPERATING AUTHORITIES NO SCALE W S N E SITE LOCATION MAP NO SCALE W S N E SEE SHEET C202 FOR SOIL DEFINITIONS. LATITUDE: 39°56'21" N, LONGITUDE: 86°09'45" W 947 W. 146TH STREET CARMEL, IN PLANS PREPARED BY WEIHE ENGINEERS 10505 N. COLLEGE AVE. INDIANAPOLIS, INDIANA 46280 TELEPHONE: (317) 846-6611 CONTACT PERSON: DUANE SHARRER EMAIL: SHARRERD@WEIHE.NET PLANS PREPARED FOR LESS IMPACT DEVELOPMENT 8910 PURDUE ROAD, SUITE 425 INDIANAPOLIS, INDIANA 46268 TELEPHONE: (317) 816-1230 CONTACT PERSON: SCOTT SCHUTZ EMAIL: SCOTT@EQUITEAMLLC.COM CONSTRUCTION PLANS FOR BEDFORD FALLS OF CARMEL SCALE: 1"=100' SOILS MAP AREA LOCATION MAP Know what'sbelow. before you dig.Call R 10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: C:\Users\hansenb\appdata\local\temp\AcPublish_32748\C001 Title Sheet.dwgLAYOUT: C001DATE/TIME: August 31, 2022 - 10:46amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) Sheet List Table Sheet Number Sheet Title C001 TITLE SHEET 1-2 ALTA SURVEY BY OTHERS C100 EXISTING CONDITIONS & DEMOLITION PLAN C200 STORMWATER POLLUTION PREVENTION PLAN PHASE I C201 STORMWATER POLLUTION PREVENTION PLAN PHASE II C202-C204 SWPPP SPECIFICATIONS & DETAILS C300 DEVELOPMENT PLAN C301 EMERGENCY FLOOD ROUTE PLAN C400-C402 STREET PLAN & PROFILE C403 INTERSECTION DETAIL C404 ENTRANCE PLAN C405 MAINTENANCE OF TRAFFIC PLAN C406 SIGN & SSD PLAN C407-C408 STREET DETAILS C500-C501 SANITARY PLAN & PROFILE C502-C503 SANITARY SPECIFICATIONS & DETAILS C600-C604 STORM PLAN & PROFILE C605-C606 STORM DETAILS C700 WATER PLAN C701 WATER SPECIFICATIONS & DETAILS L100 LANDSCAPE PLAN L110 LANDSCAPE DETAILS PZ-2022-00027 LAND DESCRIPTION PART OF THE NORTH HALF OF SECTION 22, TOWNSHIP 18 NORTH, RANGE 3 EAST OF THE SECOND PRINCIPAL MERIDIAN, CLAY TOWNSHIP, HAMILTON COUNTY, INDIANA, DESCRIBED AS FOLLOWS: COMMENCING AT A POINT ON THE NORTHEAST CORNER OF THE NORTHWEST QUARTER OF SAID SECTION 22; THENCE SOUTH 00 DEGREES 22 MINUTES 12 SECONDS WEST ON AND ALONG THE EAST LINE OF SAID NORTHWEST QUARTER SECTION 90.00 FEET TO A CAPPED REBAR LABELED “BOUNDARY PROS”, SAID POINT BEING THE POINT OF BEGINNING OF THIS DESCRIPTION; THENCE SOUTH 86 DEGREES 05 MINUTES 40 SECONDS EAST 126.21 FEET; THENCE NORTH 89 DEGREES 21 MINUTES 41 SECONDS EAST 286.52 FEET TO A POINT ON THE WEST LINE OF THE BALLENTRAE SUBDIVISION AS DESCRIBED IN INSTRUMENT NO. 200400034497; THENCE CONTINUING ALONG SAID WEST LINE SOUTH 00 DEGREES 21 MINUTES 56 SECONDS WEST 394.98 FEET TO A POINT ON THE NORTH LINE OF LOT 153 IN THE PONDS WEST SECTION 6 SUBDIVISION AS DESCRIBED IN INSTRUMENT NO. 9451187; THENCE CONTINUING ALONG SAID LOT LINE SOUTH 89 DEGREES 21 MINUTES 41 SECONDS WEST 412.50 FEET TO THE NORTHWEST CORNER OF LOT 165 IN THE PONDS WEST SECTION 6; THENCE SOUTH 00 DEGREES 21 MINUTES 56 SECONDS WEST 530.24 FEET TO THE NORTHWEST CORNER OF LOT 68 IN THE KINGSBOUROUGH SUBDIVISION AS DESCRIBED IN INSTRUMENT NO. 99009914628; THENCE CONTINUING ALONG THE NORTH LINE OF SAID KINGSBOUROUGH SUBDIVISION SOUTH 89 DEGREES 21 MINUTES 22 SECONDS WEST 598.69 FEET TO THE SOUTHEAST CORNER OF LOT 8 IN THE WESTCHASE SUBDIVISIONS AS DESCRIBED IN INSTRUMENT NO. 200000051957; THENCE CONTINUING ALONG THE EAST LINE OF SAID WESTCHASE SUBDIVISION NORTH 00 DEGREES 46 MINUTES 40 SECONDS WEST 940.08 FEET TO A RIGHT-OF-WAY MONUMENT FOUND AT THE SOUTH LINE OF RIGHT-OF-WAY AS DESCRIBED IN INSTRUMENT NO. 2013066531; THENCE CONTINUING NORTH 89 DEGREES 21 MINUTES 23 SECONDS EAST 518.18 FEET; THENCE SOUTH 87 DEGREES 45 MINUTES 26 SECONDS EAST 99.30 FEET TO THE POINT OF BEGINNING CONTAINING 16.87 ACRES, MORE OR LESS. SETBACKS (PUD - BEDFORD FALLS Z-667-21) FRONT YARD: 20' REAR YARD: 15' SIDE YARD: 5' (15' AGGREGATE MIN.) LOT COVERAGE: 50% MAX. DISTURBED ACREAGE: 16.69 ANTICIPATED CONSTRUCTION START DATE: JUNE 1, 2022 11/07/22 W W W W W W W EG G G G G G G G G G G G G G G G G G GOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUEEEREMOVE 15" CMP 146TH STREET VAR. WIDTH ROW W W W W W W W W W W W W W W WPARKHURSTDRIVE E EEELOT 64 OWNER: DENISE M. BRAGGLOT 13OWNER:CHRISTOPHER S. &SEEMA M. MERNITZLOT 10OWNER: MICHELE L. &FERNANDO MORALESBLOCK COWNER: WESTCHASE HOA, INC.BLOCK B OWNER: WESTCHASE HOA, INC.WESTCHASE SUBDIVISIONINSTRUMENT NO. 200000051957PONDS WEST - SECTION 5INSTRUMENT NO. 9451186PONDS WEST - SECTILOT 12OWNER: JEFFREY K. &EVA M. TOMLINSONLOT 11OWNER: CRAIG B. & KELLY J.ROBBINSLOT 9 OWNER: JEFFREY P. & HEATHER L. KECK LOT 8 OWNER: DAVID P. & KRISTAN E. LINTON LOT 7 OWNER: HAI FENG & ZHI XU LOT 65 OWNER: NEIL A. & LYNN K. ZLATNISKI LOT 66 OWNER: GANI, HABIBULLA & YASMIN HAJIRA MOHAMED LOT 67 OWNER: ROBERT A. & LISA M. KNAPP LOT 68 OWNER: RAYMOND E. & ANDREA MULLER LOT 146 OWNER: MICHELLE R. & CHAD E. MOORE LOT 151 OWNER: CHRISTIAN E. & SARA J. GRETHLEIN LOT 165 OWNER: TODD J. DARLAND & TRACY R. WEGMAN-DARLAND BLOCK DOWNER: WESTCHASE HOA, INC.BIRDSONG LANE 146TH STREET W W W W W W G G G G G G WOHU OHU OHU OHU LOT 152 OWNER: RONALD J. & JUDITH A. HANSON WARRANTY DEED BOARD OF COMMISSIONERS OF HAMILTON COUNTY INSTRUMENT NO. 2013066530 BALLANTRAE SUBDIVISIONINSTRUMENT NO. 200400034497BFE 886.8 BFE 886.9 BFE 886.7 BFE 886.5 BFE 886.3 BFE 886.2ZONE AE ZONE AE ZONE AE ZONE AE ZONE AE ZONE AE Know what'sbelow. before you dig.Call R W S N E GENERAL DEMOLITION NOTES: 1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY LOCATIONS OF ALL EXISTING UTILITIES PERTAINING TO THEIR PHASE OF WORK. 2. LOCATIONS OF UTILITIES NOTED TO BE REMOVED ARE APPROXIMATE AND SHALL BE RELOCATED, CAPPED AND/OR ABANDONED PRIOR TO CONSTRUCTION. 3. ALL DEMOLITION MATERIAL AND SALVAGEABLE MATERIAL ARE THE PROPERTY OF THE DEMOLITION CONTRACTOR AND SHALL BE PROPERLY DISPOSED OF OFFSITE. 4. THE CONTRACTOR SHALL OBTAIN ALL DEMOLITION PERMITS REQUIRED BY LOCAL AND STATE AGENCIES. 5. THE CONTRACTOR SHALL REMOVE ALL EXISTING FENCES LOCATED INTERNALLY ON SITE. PERIMETER FENCES TO REMAIN EXCEPT WHERE INDICATED BY OWNER. 6. THE CONTRACTOR SHALL MAINTAIN STREETS FREE AND CLEAR OF SEDIMENT AND DEBRIS. 7. ANY SEPTIC SYSTEM COMPONENTS FOUND ON SITE ARE TO BE REMOVED COMPLETELY IN ACCORDANCE WITH HAMILTON COUNTY HEALTH DEPARTMENT REQUIREMENTS. 8. ANY WATER WELLS FOUND ON SITE ARE TO BE CLOSED IN ACCORDANCE WITH THE HAMILTON COUNTY HEALTH DEPARTMENT REQUIREMENTS. 9. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 10. ALL EXISTING PERIMETER ROAD DRAINAGE STRUCTURES AND BRIDGES ACROSS THE FRONTAGE OF THIS DEVELOPMENT ARE INDICATED ON THE PLANS. PROVISIONS HAVE BEEN MADE TO IMPROVE OR REPLACE ANY DRAINAGE STRUCTURES AND BRIDGES AS NECESSARY OR AS REQUESTED BY THE CITY TO ACCOMMODATE THE PAVEMENT WIDENING, AUXILIARY LANES, MULTI-USE PATH, AND ANY OTHER REQUIRED IMPROVEMENTS TO THE PROPERTY OR THE ROADWAY. THE COST TO IMPROVE OR REPLACE ANY DRAINAGE STRUCTURES AND BRIDGES WILL BE BORNE BY THE DEVELOPER. 11. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 12. ACCESS TO EX 402 TO BE ABANDONED. REMOVE FRAME AND SOLID LID. REMOVE RISER RING(S). REPLACE FRAME AND SOLID LID. BACKFILL WITH COMPACTED #53 STONE TO SUBGRADE ELEVATION. EXTEND COMPACTED SUBGRADE STONE OVER STRUCTURE TO PREPARE FOR PAVING. 13. REMOVE CASTING, CAP INLET AT OR CLOSE TO SUBGRADE IN A MANNER ACCEPTABLE TO THE HIGHWAY DEPARTMENT HARRISON MONUMENT FOUND REBAR FOUND PK OR MAG NAIL FOUND STONE FOUND BENCH MARK TEMPORARY BENCH MARK OTHER MONUMENT GUY ANCHOR UTILITY POLE COMMUNICATIONS JUNCTION BOX COMMUNICATIONS PEDESTAL UNDERGROUND GAS UNDERGROUND WATER RIGHT OF WAY LINE CHAIN LINK FENCE BOARD FENCE VINYL PICKET FENCE BOUNDARY LINE FLOW LINE FIRE HYDRANT WATER METER WATER VALVE GAS METER GAS VALVE MAIL BOX POST BEEHIVE INLET G G W W C C OHU MEASURED DIMENSION DEED DIMENSION MARION COUNTY SURVEYOR'S OFFICE CORRUGATED METAL PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE (M) (D) MCSO CMP RCP PVC SECTION LINE FARM FENCE FIBER OPTIC MARKER STORM SEWER INV INVERT LEGEND: ASPHALT CONCRETE (CONC) MAG NAIL WITH WASHER STAMPED "WEIHE ENGR. 0012" SET 5/8" Ø REBAR WITH YELLOW PLASTIC CAP STAMPED "WEIHE ENGR. 0012" SET MIXED OR UNIDENTIFIED OVERHEAD UTILITY UNDERGROUND COMMUNICATIONS RESIDENTIAL ON-SITE SEWAGE SYSTEM RULE 410 IAC 6-8.3 PER INDIANA STATE DEPARTMENT OF HEALTH 410 IAC 6-8.3-90 ABANDONMENT OF AN ON-SITE SEWAGE SYSTEM SEC. 90. A. WHEN THE USE OF AN ON-SITE SEWAGE SYSTEM IS DISCONTINUED, THE FOLLOWING PROCEDURE MUST BE FOLLOWED FOR ALL TANKS AND ELECTRICAL SERVICE: (1) ELECTRICAL POWER MUST BE DISCONNECTED AT THE SOURCE. ALL CONTROLS AND PANELS MUST BE REMOVED. (2) ALL ABOVE GROUND ELECTRICAL LINES THAT WILL NOT BE USED FOR OTHER PURPOSES MUST BE REMOVED. (3) A LICENSED SEPTIC TANK CLEANER MUST PUMP ALL CONTENTS FROM ALL TANKS IN THE ON-SITE SEWAGE SYSTEM. (4) THE TANKS MUST EITHER BE: (A) REMOVED OR THE LIDS CRUSHED INTO THE TANKS AND THE HOLES OR TANKS BACKFILLED WITH DEBRIS-FREE SAND OR OTHER GRANULAR MATERIAL, CONCRETE, OR SOIL MATERIAL THAT IS COMPACTED TO PREVENT SETTLING. (IF A SAND MOUND IS BEING ABANDONED, SAND, AGGREGATE AND SOIL COVER FROM THE SAND MOUND MAY BE USED FOR FILLING THE TANK OR TANKS); OR (B) FILLED WITH FLOWABLE FILL. (5) PROPERLY GRADE AND ESTABLISH VEGETATIVE COVER. B. THE COMPONENTS OF THE SOIL ABSORPTION SYSTEM MAY BE LEFT INTACT, IF THERE ARE NO PLANS TO USE THE AREA FOR OTHER PURPOSES. VEGETATIVE COVER MUST BE MAINTAINED. C. IF EFFLUENT HAS SURFACED, THOSE AREAS MUST BE COVERED WITH HYDRATED LIME FOLLOWED BY TOP SOIL AND A VEGETATIVE COVER. D. IF COMPONENTS OF THE SOIL ABSORPTION SYSTEM ARE TO BE REMOVED, THE FOLLOWING PROCEDURE MUST BE USED: (1) A LICENSED SEPTIC TANK CLEANER MUST PUMP ALL CONTENTS FROM ALL DISTRIBUTION BOXES IN THE ON-SITE SEWAGE SYSTEM. (2) ALLOW SUFFICIENT TIME AFTER THE ON-SITE SEWAGE SYSTEM IS TAKEN OUT OF SERVICE AND THE TANKS PUMPED TO MAKE SURE THE ENTIRE SOIL ABSORPTION SYSTEM IS COMPLETELY DRY. (3) A CONTRACTOR MUST REMOVE THE DISTRIBUTION NETWORK, AGGREGATE, AND SAND (IF ANY) FROM THE SITE. (4) THE CONTRACTOR MUST DISPOSE OF THE MATERIALS AT A LICENSED LANDFILL. (5) THE SITE MUST BE PROPERLY GRADED AND A VEGETATIVE COVER ESTABLISHED. E. WRITTEN DOCUMENTATION OF TANK ABANDONMENT MUST BE PROVIDED TO THE LOCAL HEALTH DEPARTMENT BY THE DEVELOPER IN THE FORM OF A RECEIPT FROM THE CONTRACTOR. GENERAL NOTES: 1. BASED UPON A SCALED INTERPRETATION OF THE FLOOD INSURANCE RATE MAPS, PANEL 136 AND 145 OF 352, MAP NO. 18081C0126D AND 18081C0145D FOR JOHNSON COUNTY, INDIANA DATED AUGUST 02, 2007, THE WITHIN DESCRIBED REAL ESTATE IS NOT LOCATED WITHIN A SPECIAL FLOOD HAZARD AREA INUNDATED BY A 1% ANNUAL CHANCE FLOOD (100-YEAR FLOOD) AS ESTABLISHED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY FOR THE NATIONAL FLOOD INSURANCE PROGRAM. THE WITHIN DESCRIBED REAL ESTATE IS LOCATED WITHIN (UNSHADED) ZONE X (AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN), FLOOD PLAIN CERTIFICATION IS RESTRICTED TO A REVIEW OF THE FLOOD INSURANCE RATE MAPS (FIRM), AND SHALL NOT BE CONSTRUED AS A CONFIRMATION OR DENIAL OF FLOODING POTENTIAL. 2. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS SURVEY ARE BASED UPON ABOVE GROUND EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, INLETS, VALVES, AND/OR MARKS MADE UPON THE GROUND BY INDIANA UNDERGROUND PLANT PROTECTION SERVICE AND BAKER UTILITY PARTNERS, A PRIVATE UTILITY LOCATOR) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION OF PLANNED IMPROVEMENTS ON OR NEAR THE PROPERTY. 3. BOUNDARY LINES SHOWN HEREON ARE BASED FROM A LAND TITLE SURVEY PREPARED BY BOUNDARY PROS LAND SURVEYING UNDER PROJECT NO. 20-180, DATED OCTOBER 26, 2020 AND ARE SHOWN FOR REFERENCE ONLY. NO VERIFICATION OF THE ACCURACY OF SAID DRAWING WAS CONDUCTED AS PART OF THIS PROJECT 4. THE TOPOGRAPHIC SURVEY WAS PERFORMED BY WEIHE ENGINEERS DATED SEPTEMBER 2, 2021.C100 Demo PlanC100EXISTING CONDITIONS & DEMOLITION PLANW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9abcd 8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C100 Demo Plan.dwgLAYOUT: C100DATE/TIME: August 31, 2022 - 10:46amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) DISTURBED ACREAGE = 16.69 ± AC. TREE PRESERVATION FENCE FLOODWAY LIMITS 100 YR FLOODPLAIN LIMITS FLOODWAY / FLOODPLAIN TEMPORARY SWALE 11/07/22 W W W EG G G G G G G G G G G G G G G G GGOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU VAR. WIDTH ROW W W W W W W W W W W W W W W W LOT 64 OWNER: DENISE M. BRAGGLOT 13OWNER:CHRISTOPHER S. &SEEMA M. MERNITZLOT 10OWNER: MICHELE L. &FERNANDO MORALESBLOCK COWNER: WESTCHASE HOA, INC.BLOCK B OWNER: WESTCHASE HOA, INC. KINGSBOROUGH - SECTION 3 INSTRUMENT NO. 9909914628WESTCHASE SUBDIVISIONINSTRUMENT NO. 200000051957PONDS WEST - SECTION 5INSTRUMENT NO. 9451186LOT 12OWNER: JEFFREY K. &EVA M. TOMLINSONLOT 11OWNER: CRAIG B. & KELLY J.ROBBINSLOT 9 OWNER: JEFFREY P. & HEATHER L. KECK LOT 8 OWNER: DAVID P. & KRISTAN E. LINTON LOT 7 OWNER: HAI FENG & ZHI XU LOT 65 OWNER: NEIL A. & LYNN K. ZLATNISKI LOT 66 OWNER: GANI, HABIBULLA & YASMIN HAJIRA MOHAMED LOT 67 OWNER: ROBERT A. & LISA M. KNAPP LOT 68 OWNER: RAYMOND E. & ANDREA MULLER OWNER: LOT 146 OWNER: MICHELLE R. & CHAD E. MOORE LOT 151 OWNER: CHRISTIAN E. & GRETHLEIN LOT OWNER: TODD TRACY R. WEGMA BLOCK DOWNER: WESTCHASE HOA, INC.BIRDSONG LANE STREET SF SFSFSFSFSFSFIPIPIP IP IP IP SFSFSFSF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SFSFSFSFSFSFSFSFSF SFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFDDDDD D DDDDDDDDDDDDDDDDDDDDDD D D D D D D D D DDDDDDDDD D D D DDDDDDDD DDDDDD DDDDDDDDDDDDDDDDDDDDDD SFSFSFSFW W W W W W W G G G G G G G WOHU OHU OHU OHU OHU LOT 165 LOT 152 OWNER: RONALD J. & JUDITH A. WARRANTY DEED BOARD OF COMMISSIONERS OF HAMILTON COUNTY INSTRUMENT NO. 2013066530 BALLANTRAE SUBDIVISIONINSTRUMENT NO. 200400034497BFE 886.8 BFE 886.9 BFE 886.7 BFE 886.5 BFE 886.3 886.2ZONE AE ZONE AE ZONE AE ZONE AE SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFD D D D D D DDDDDDDDDDDDDDDDDDKnow what'sbelow. before you dig.Call R W S N E DISTURBED ACREAGE = 16.69 ± AC. NOTES: 1. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 2. THIS PLAN INDICATES EROSION CONTROL MEASURES REQUIRED BEFORE SOIL STRIPPING AND PAD CONSTRUCTION IS TAKING PLACE. COORDINATE WITH SOIL CONSERVATION DISTRICT REPRESENTATIVE FOR ANY OTHER MEASURES REQUIRED DUE TO SITE CONDITIONS. 3. THIS PLAN IS TO BE USED FOR STORMWATER POLLUTION PREVENTION PURPOSES ONLY. FOR ANY OTHER INFORMATION SEE SITE CONSTRUCTION PLANS AND DETAILS. 4. ALL DISTURBED AREAS THAT WILL BE POTENTIALLY IDLE FOR 15 DAYS OR MORE TO BE STABILIZED (SEEDED, MULCHED, ETC) IMMEDIATELY. 5. NO EARTHMOVING MAY TAKE PLACE WITHOUT AN APPROVED STORMWATER POLLUTION PREVENTION PLAN. 6. ADDITIONAL STORMWATER POLLUTION PREVENTION MEASURES MAY BE REQUIRED IN THE FIELD BY THE MS4 REPRESENTATIVE. 7. THERE SHALL BE NO DIRT, DEBRIS OR STORAGE OF MATERIALS IN THE STREETS. 8. SILT FENCE SHALL BE PLACED AS SHOWN ON THE PLANS PRIOR TO ANY EARTHWORK. 9. ALL WORK WITHIN THE RIGHT-OF-WAY SHALL MEET CURRENT LOCAL CONSTRUCTION STANDARDS. 10. THE CONTRACTOR SHALL PROTECT EXISTING RIGHT-OF-WAY INFRASTRUCTURE AND BE RESPONSIBLE FOR RESTORATION AS NECESSARY. 11. THE CITY OF CARMEL IS THE REVIEW AUTHORITY FOR THE EROSION CONTROL ACTIVITIES REQUIRING CONTACT, PRE-CONSTRUCTION MEETING INVITATION, SELF-MONITORING REPORT DELIVERY TO THEIR MS4 REPRESENTATIVE. 12. NOTICE OF THE SCHEDULED DATE FOR COMPLETION OF CONSTRUCTION SHALL BE PROVIDED TO THE MS4 REPRESENTATIVE AT LEAST SEVENTY TWO (72) HOURS PRIOR TO COMPLETION. THE CONTRACTOR OR OWNER WILL SCHEDULE THE FINAL INSPECTION; THE STORM DRAIN AND SITE GRADING PERFORMANCE SURETIES WILL BE RELEASED AFTER SUBMITTAL AND APPROVAL 13. APPROXIMATE CONSTRUCTION SCHEDULE: START DATE: June 1, 2022 COMPLETION DATE: June 1, 2027 RECEIVING WATERS = Williams Creek 14. LATITUDE = 39° 59' 54" N, LONGITUDE = 86° 10' 28" W 15. HYDROLOGIC UNIT CODE: 05120201090060 16. PERSON IN CHARGE OF SWPPP IMPLEMENTATION: LESS IMPACT DEVELOPMENT 8910 PURDUE ROAD, SUITE 425 INDIANAPOLIS, INDIANA 46268 TELEPHONE: (317) 816-1230 CONTACT PERSON: SCOTT SCHUTZ EMAIL: SCOTT@EQUITEAMLLC.COM LEGEND PHASE I EROSION CONTROL (BEFORE MAJOR EARTHWORK) PRE CONSTRUCTION ACTIVITIES 1. CALL THE INDIANA UNDERGROUND PLANT PROTECTION SYSTEMS, INC. (“HOLEY MOLEY”) AT 811 TWO WORKING DAYS BEFORE CONSTRUCTION BEGINS TO CHECK THE LOCATIONS OF ANY EXISTING UTILITIES. 2. CONTACT THE MS4 STORMWATER DEPARTMENT INSPECTOR TO SCHEDULE A PRE-CONSTRUCTION MEETING AT LEAST 3 WORKING DAYS PRIOR TO THE START OF CONSTRUCTION. 3. CONTACT IDEM AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 4. INSTALL SILT FENCE AT THE EDGES OF THE PROJECT SITE WHERE THERE IS POTENTIAL FOR ANY STORMWATER RUNOFF AS DENOTED ON THE STORMWATER POLLUTION PREVENTION PLAN. POTENTIAL AREAS ARE IDENTIFIED BASED ON EXISTING TOPOGRAPHY AROUND THE PERIMETER OF THE SITE. 5. INSTALL INLET PROTECTION ON ALL EXISTING STORM SEWER STRUCTURES WITHIN THE CONSTRUCTION LIMITS OF THE PROJECT AS INDICATED ON THE PLANS. 6. EVALUATE, MARK AND PROTECT IMPORTANT TREES AND ASSOCIATED ROOT ZONES. EVALUATE EXISTING VEGETATION SUITABLE FOR USE AS FILTER STRIPS ALONG THE PERIMETER OF THE SITE. 7. INSTALL CONSTRUCTION ENTRANCE IN THE LOCATION SHOWN ON THE PLANS AND PER SPECIFICATIONS. 8. ESTABLISH CONSTRUCTION STAGING AREA FOR EQUIPMENT AND VEHICLES AS FAR FROM DETENTION PONDS AND SWALES AS POSSIBLE. 9. INSTALL TRASH DUMPSTER, CONCRETE WASHOUT AREA AND PLACE PORT-O-LET AS INDICATED ON THE PLANS. 10.ESTABLISH ONSITE LOCATION FOR OWNER/CONTRACTOR PLACEMENT OF APPROVED PLANS, RULE 5 NOI AND RULE 5 INSPECTION DOCUMENTS. 11.CONTACT THE MS4 REPRESENTATIVE TO CONDUCT INITIAL EROSION INSPECTION BEFORE MASS EARTHWORK. CONSTRUCTION SEQUENCING THE PURPOSE OF STAGING CONSTRUCTION DURING THE PROJECT IS TO LIMIT THE AMOUNT OF GROUND DISTURBED AT ANY GIVEN TIME AND TO PREVENT SEDIMENT FROM LEAVING THE SITE. THE FOLLOWING SEQUENCE OF CONSTRUCTION SHOULD BE FOLLOWED AS MUCH AS POSSIBLE. ANY DEWATERING REQUIRED DURING CONSTRUCTION OF THIS PROJECT SHALL BE DONE THROUGH A “DANDY” DEWATERING BAG OR APPROVED EQUAL. DO NOT PLACE DEWATERING BAG WITHIN 50 FEET OF A SWALE, DITCH OR CREEK. 1. CLEAR AND STRIP AT POND OUTLET AREAS. 2. INSTALL POND OUTLETS. 3. INSTALL POND MOUNDING AT DOWNSTREAM LOCATIONS STARTING AT DOWNSLOPE SIDES. 4. CONSTRUCT PONDS. 5. CONTINUE SITE CLEARING. 6. STRIP TOPSOIL OR SOIL CONTAINING VEGETATION AND ROOT FIBERS FROM STREET AND BUILDING PAD AREAS AND PLACE IN TOPSOIL STOCKPILE AREA AS NOTED ON THE PLANS. 7. COMPLETE ALL MASS GRADING REQUIRED TO PREPARE ROADS, BUILDING SUBGRADES AND PADS. IF LIME OR OTHER SOLID ADDITIVES WILL BE USED TO STABILIZE THE STREET SUBGRADE, APPLY BEFORE ANY STORM SEWER INSTALLATION. 8. INSTALL ALL STORM SEWER SYSTEMS, SANITARY SEWER SYSTEMS, WATER DISTRIBUTION SYSTEMS AND OTHER UTILITIES. INSTALL ALL INLET PROTECTION AS EACH INLET IS COMPLETED AS SHOWN ON THE PLANS AND THE DETAIL SHEETS. 9. COMPLETE GRADING FOR ALL BUILDING AREAS AND ROAD SUBGRADES AS SHOWN ON THE PLANS. 10. INSTALL CURBING, AND PAVE ALL ROADS 11.INSTALL TEMPORARY SEEDING IN ALL GRADED AREAS THAT WILL NOT BE DISTURBED FOR 14 DAYS OR MORE. POND BANKS SHALL RECEIVE PERMANENT SEED AND EROSION CONTROL BLANKET AS SHOWN ON THE PLANS. 12.FINISH GRADE ALL SWALES. APPLY PERMANENT SEED AND EROSION CONTROL BLANKETS AS SHOWN ON THE PLANS. 13.PREPARE SEED BED AND APPLY PERMANENT SEED IN ALL COMMON AREAS AND EASEMENT AREAS AS DENOTED ON THE PLANS. 14.CLEAN AND MAINTAIN ALL INLET PROTECTION, SILT FENCE, EROSION CONTROL BLANKETS, TEMPORARY SILTATION BASINS AND TEMPORARY SEEDING AREAS UNTIL THE PROJECT IS COMPLETELY BUILT OUT. 15.IF SEEDED AREAS DO NOT PRODUCE A MINIMUM OF 70 PERCENT VEGETATIVE COVER, CONTRACTOR SHALL RE-SEED TO OBTAIN ADEQUATE VEGETATIVE COVER FOR STABILIZATION OF THE SITE. 16.REMOVE ALL TEMPORARY EROSION CONTROL PRACTICES INCLUDING SILT FENCE WHEN ENTIRE SITE HAS REACHED 70 PERCENT VEGETATIVE COVER.C200 SWPPP IC200STORMWATER POLLUTION PREVENTION PLAN PHASE IW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C200 SWPPP I.dwgLAYOUT: C200DATE/TIME: August 31, 2022 - 10:47amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) - CONSTRUCTION ENTRANCE (8" OF #2 STONE ON NON-WOVEN GEOTEXTILE FABRIC) - STAGING AREA (8" OF #2 STONE ON NON-WOVEN GEOTEXTILE FABRIC) - POSTING AREA - 4" PVC TUBE WITH END CAPS ATTACHED TO PROJECT CONSTRUCTION SIGN TO CONTAIN APPROVED CONSTRUCTION DRAWINGS AND PERMITS FOR INSPECTORS. - SHEET FLOW PROTECTION / SILT FENCE - CONCRETE WASHOUT - LIMITS OF CONSTRUCTION - PROPOSED INLET PROTECTION (DANDY SACKS AND WIRE SILT FENCES) FOR EXISTING STRUCTURES REQUIRED. (SEE DETAILS ON SHEET C207) - ROCK CHECK DAM - TREE PROTECTION FENCE - TEMPORARY SWALE IP SF D 11/07/22 W W EG G G G G G G G G G G G G G G GGOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU VAR. WIDTH ROW W W W W W W W W W W W W W W W LOT 64 OWNER: DENISE M. BRAGGLOT 13OWNER:CHRISTOPHER S. &SEEMA M. MERNITZLOT 10OWNER: MICHELE L. &FERNANDO MORALESBLOCK COWNER: WESTCHASE HOA, INC.BLOCK B OWNER: WESTCHASE HOA, INC. KINGSBOROUGH - SECTION 3 INSTRUMENT NO. 9909914628WESTCHASE SUBDIVISIONINSTRUMENT NO. 200000051957PONDS WEST - SECTION 5LOT 12OWNER: JEFFREY K. &EVA M. TOMLINSONLOT 11OWNER: CRAIG B. & KELLY J.ROBBINSLOT 9 OWNER: JEFFREY P. & HEATHER L. KECK LOT 8 OWNER: DAVID P. & KRISTAN E. LINTON LOT 7 OWNER: HAI FENG & ZHI XU LOT 65 OWNER: NEIL A. & LYNN K. ZLATNISKI LOT 66 OWNER: GANI, HABIBULLA & YASMIN HAJIRA MOHAMED LOT 67 OWNER: ROBERT A. & LISA M. KNAPP LOT 68 OWNER: RAYMOND E. & ANDREA MULLER LOT OWNER: MICHEL E. MOORE OWNER: OWNER: TRAC BLOCK DOWNER: WESTCHASE HOA, INC.BIRDSONG LANE STREET 26 1 7 8 9 11 12 10 13 28 27 24 25 23 16 17 18 14 3 2 5 4 29 30 31 32 33 34 1920 22 6 21 15 W W W WWWWWWWWWWWWWWW WWWWWW W W W WWWWWWWWWWWWW W W W W WBEDFORDFALLS DR.GOWER DRIVE BIRDSONG LANEMITCHEL LANEBEDFORDFALLS DRIVE* ** * * * * * * * * * * * * * ** * * SANSANSANSAN C.A. A C.A. A C.A. B C.A. A C.A. C SAN SAN SAN SAN SAN SANSANSANSAN FMFMFMFMFMFMFM* * FMFMFMFMFMFMFMSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF IPIPIP IP IP IP SFSFSFSF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SFSFSFSFSFSFSFSFSF SFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFDDDDD D DDDDDDDDDDDDDDDDDDDDDD D D D D D D D D DDDDDDDDD D D D DDDDDDDD DDDDDD DDDDDDDDDDDDDDDDDDDDSFSFSFSFSFS F SF SF SF SF SF SF SF SFSFSFSFIP IP IP IP IP IP IP IP IP IP IP IP IP IPIP IP IP IPIP IP IP IP IP IP IP IP IP IP IP IP W W W W W W W W G G G G G G G G WOHU OHU OHU OHU OHU OHU LOT 165 LOT 152 OWNER: RONALD J. & JUDITH A. WARRANTY DEED BOARD OF COMMISSIONERS OF HAMILTON COUNTY INSTRUMENT NO. 2013066530 BALLANTRAE SUBDIVISIONINSTRUMENT NO. 200400034497BFE 886.8 BFE 886.9 BFE 886.7 BFE 886.5 BFE 886.3 886.2ZONE AE ZONE AE ZONE AE ZONE AE POND 1 C.A. C GUARDRAIL SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFD D D D D D DDDDDDDDDDDDDDDDDDDSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFS F SF SF SF SFSFSFSF SF SF SFIP * Know what'sbelow. before you dig.Call R W S N E PHASE II EROSION CONTROL (AFTER MAJOR EARTHWORK) LEGEND * SF D - INLET PROTECTION (DANDY SACKS AND WIRE SILT FENCES) FOR PROPOSED STRUCTURES (SEE TOWN OF CICERO STANDARD DETAILS) - PROPOSED INLET PROTECTION (DANDY SACKS AND WIRE SILT FENCES) FOR EXISTING STRUCTURES REQUIRED. (SEE TOWN OF CICERO STANDARD DETAILS) - PERMANENT SEEDING (USE PLANTING CHART) AT A MINIMUM, MULCH IS REQUIRED. - EROSION CONTROL BLANKET (USE STAPLE PATTERN N.A.G. S150.) - TEMPORARY SEEDING - NATIVE AQUATIC SHORELINE SEED MIX (SEE LANDSCAPE PLAN) - SHEET FLOW PROTECTION - SWALE - CONSTRUCTION LIMITS - LOCATION WHERE STORMWATER LEAVES SITE - STORMWATER QUALITY FEATURE IP IP DISTURBED ACREAGE = 16.69 ± AC. POST CONSTRUCTION SEQUENCING THE PURPOSE OF THE POST CONSTRUCTION PHASE IS TO IDENTIFY AND MAINTAIN ALL POST CONSTRUCTION BEST MANAGEMENT PRACTICE (BMP) STRUCTURES THUS REDUCING RUNOFF AND CONTROLLING POLLUTANTS. THE FOLLOWING SEQUENCING SHOULD BE FOLLOWED AS MUCH AS POSSIBLE. 1. DISTRIBUTE POST CONSTRUCTION BMP OPERATIONS AND MAINTENANCE MANUAL (O&M MANUAL) TO OWNER AND HOME OWNERS ASSOCIATION.THE O&M MANUAL IDENTIFIES AND LOCATES THE BMP STRUCTURE FOR THE OWNER. 2. STORMWATER WET DETENTION POND BMP OWNERS MUST ROUTINELY INSPECT BMP TO VERIFY THAT ALL BMP COMPONENTS ARE FUNCTIONING AS DESIGNED AND ARE NOT IN DANGER OF FAILING. ALL BMP NEED MAINTENANCE TO FUNCTION AS WATER QUALITY ENHANCEMENTS. MAINTENANCE CAN RANGE FROM DREDGING SEDIMENT OUT OF THE TREATMENT AREA TO MOWING GRASS. 3. BMP OWNER IS RESPONSIBLE FOR THE MAINTENANCE OF THE BMP AND ANY COSTS ASSOCIATED WITH MAINTAINING THE BMP. 4. BMP OWNER SHALL KEEP THE BMP FREE FROM LITTER AND WOODY GROWTH. REFER TO THE INSPECTION AND MAINTENANCE GUIDELINES FOR FURTHER CLARIFICATION. 5. SEDIMENT THAT COLLECTS IN THE BMP SHALL BE REMOVED WHEN IT ADVERSELY AFFECTS THE ABILITY OF THE BMP TO PERFORM AS A WATER QUALITY CONTROL DEVICE. SEDIMENT SHALL BE REMOVED FROM THE POND WHEN THE WATER DEPTH IS 8 FEET OR LESS.C201 SWPPP IIC201STORMWATER POLLUTION PREVENTION PLAN PHASE IIW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C201 SWPPP II.dwgLAYOUT: C201DATE/TIME: August 31, 2022 - 10:47amPLOTTED BY: hansenbfhgEN G I N EER S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) NOTES: 1. THIS PLAN INDICATES EROSION CONTROL MEASURES REQUIRED BEFORE SOIL STRIPPING AND PAD CONSTRUCTION IS TAKING PLACE. COORDINATE WITH SOIL CONSERVATION DISTRICT REPRESENTATIVE FOR ANY OTHER MEASURES REQUIRED DUE TO SITE CONDITIONS. 2. THIS PLAN IS TO BE USED FOR STORMWATER POLLUTION PREVENTION PURPOSES ONLY. FOR ANY OTHER INFORMATION SEE SITE CONSTRUCTION PLANS AND DETAILS. 3. ALL DISTURBED AREAS THAT WILL BE POTENTIALLY IDLE FOR 15 DAYS OR MORE TO BE STABILIZED (SEEDED, MULCHED, ETC) IMMEDIATELY. 4. NO EARTHMOVING MAY TAKE PLACE WITHOUT AN APPROVED STORMWATER POLLUTION PREVENTION PLAN. 5. ADDITIONAL STORMWATER POLLUTION PREVENTION MEASURES MAY BE REQUIRED IN THE FIELD BY THE MS4 REPRESENTATIVE. 6. THERE SHALL BE NO DIRT, DEBRIS OR STORAGE OF MATERIALS IN THE STREETS. 7. SILT FENCE SHALL BE PLACED AS SHOWN ON THE PLANS PRIOR TO ANY EARTHWORK. 8. ALL WORK WITHIN THE RIGHT-OF-WAY SHALL MEET CURRENT LOCAL CONSTRUCTION STANDARDS. 9. THE CONTRACTOR SHALL PROTECT EXISTING RIGHT-OF-WAY INFRASTRUCTURE AND BE RESPONSIBLE FOR RESTORATION AS NECESSARY. 10. THE CITY OF CARMEL IS THE REVIEW AUTHORITY FOR THE EROSION CONTROL ACTIVITIES REQUIRING CONTACT, PRE-CONSTRUCTION MEETING INVITATION, SELF-MONITORING REPORT DELIVERY TO THEIR MS4 REPRESENTATIVE. 11. NOTICE OF THE SCHEDULED DATE FOR COMPLETION OF CONSTRUCTION SHALL BE PROVIDED TO THE MS4 REPRESENTATIVE AT LEAST SEVENTY TWO (72) HOURS PRIOR TO COMPLETION. THE CONTRACTOR OR OWNER WILL SCHEDULE THE FINAL INSPECTION; THE STORM DRAIN AND SITE GRADING PERFORMANCE SURETIES WILL BE RELEASED AFTER SUBMITTAL AND APPROVAL 12. APPROXIMATE CONSTRUCTION SCHEDULE: START DATE: June 1, 2022 COMPLETION DATE: June 1, 2027 RECEIVING WATERS = Williams Creek 13. LATITUDE = 39° 59' 54" N, LONGITUDE = 86° 10' 28" W 14. HYDROLOGIC UNIT CODE: 05120201090060 15. PERSON IN CHARGE OF SWPPP IMPLEMENTATION: LESS IMPACT DEVELOPMENT 8910 PURDUE ROAD, SUITE 425 INDIANAPOLIS, INDIANA 46268 TELEPHONE: (317) 816-1230 CONTACT PERSON: SCOTT SCHUTZ EMAIL: SCOTT@EQUITEAMLLC.COM BMP BMP BMP 11/07/22 SECTION 2 MATERIAL HANDLING AND SPILL PREVENTION PLAN IN ORDER TO MINIMIZE THE RELEASE OF POTENTIAL POLLUTANTS DURING CONSTRUCTION THE CONTRACTORS SHALL IMPLEMENT THIS MATERIAL HANDLING AND SPILL PREVENTION PLAN. THE CONTRACTOR SHALL REVIEW THIS PLAN WITH ALL SUBCONTRACTORS AND REQUIRE THAT THEY IMPLEMENT THE PLAN AS WELL. 1. CONSTRUCTION EQUIPMENT A. FUELING, LUBRICATION AND FLUIDS: ALL OPERATIONS INVOLVING THE ADDITION OF FLUIDS TO EQUIPMENT SHOULD BE DONE IN ONE LOCATION, AS DESIGNATED BY THE CONSTRUCTION MANAGER, SO THAT SPILLS ARE LIMITED TO ONE LOCATION ON THE SITE, WHICH WILL FACILITATE THE CLEANUP OF SPILLS. IF AN ONSITE-FUELING TANK IS PLANNED TO BE ON SITE, IT SHALL BE DOUBLE WALLED AND STORED IN THIS DESIGNED AREA. THIS LOCATION IS AN AREA THAT WILL NOT ALLOW SPILLED FLUIDS TO MIGRATE INTO SUBSURFACE SOILS. IN THE EVENT OF A SPILL, THE FLUID SHALL IMMEDIATELY BE CLEANED UP BY REMOVING THE CONTAMINATED SOIL OR STONE, WHICH SHALL BE DISPOSED OF IN AN ACCEPTABLE MANNER. SPILLS ON HARD SURFACES SHALL BE SOAKED UP BY AN ACCEPTABLE MATERIAL SUCH AS OIL DRY AND THE ABSORBENT MATERIAL DISPOSED OF IN A PROPER MANNER. THE SPILL SHALL ALSO BE REPORTED IMMEDIATELY TO THE CONSTRUCTION MANAGER'S SUPERINTENDENT. B. EQUIPMENT REPAIR, ESPECIALLY WHEN FLUIDS MUST BE REMOVED FROM THE EQUIPMENT OR THE POSSIBILITY OF FLUID SPILLS IS HIGH, SHOULD ALWAYS BE DONE OFFSITE AT A FACILITY THAT IS MORE SUITABLE THAN A CONSTRUCTION SITE TO HANDLE SPILLS. WHEN EQUIPMENT MUST BE REPAIRED ONSITE IT SHOULD BE MOVED TO THE MAINTENANCE AND FUELING AREA IF POSSIBLE. OTHERWISE, SUITABLE ON SITE CONTAINERS SHOULD BE PLACED UNDER THE EQUIPMENT DURING REPAIR TO CATCH ANY SPILLED FLUIDS AND THESE FLUIDS SHOULD BE DISPOSED OF IN A PROPER MANNER. C. ALL REUSABLE FLUID CONTAINERS, SUCH AS GASOLINE CANS, SHALL BE INSPECTED FOR LEAKS EACH TIME THEY ARE USED. IF LEAKS ARE FOUND, THE FLUID SHALL BE REMOVED FROM THE CONTAINER IN A PROPER MANNER AND THE CONTAINER DISPOSED OF IN AN ACCEPTABLE MANNER. EMPTY DISPOSABLE CONTAINER, SUCH AS GREASE TUBES AND LUBRICATING OIL AND BRAKE FLUID CONTAINERS, AND THEIR PACKAGING, SHALL BE DISPOSED OF IN A PROPER MANNER AND SHALL NOT BE LEFT ON THE GROUND OR IN THE OPEN ON THE CONSTRUCTION SITE. 2. CONSTRUCTION MATERIALS AND THEIR PACKAGING A. EROSION CONTROL MEASURE SHOWN ON THE SUBJECT PROJECT SHALL BE IMPLEMENTED PRIOR TO AND DURING CONSTRUCTION IN THE PROPER SEQUENCING TO MINIMIZE SOIL EROSION. EROSION CONTROLS SHALL BE INSPECTED AND MAINTAINED AS DESCRIBED ELSEWHERE ON THE PLANS. EXCESSIVE DUSTING OF SOIL ON THE SITE SHALL BE MINIMIZED BY REDUCING CONSTRUCTION TRAFFIC ACROSS BARE SOIL DURING DRY AND/OR WINDY WEATHER, AND BY APPLYING WATER OR OTHER ACCEPTABLE DUST CONTROL MEASURES TO THE SOIL. UPON COMPLETION OF CONSTRUCTION AND SUITABLE ESTABLISHMENT OF PERMANENT VEGETATION, TEMPORARY EROSION CONTROL MEASURES SUCH AS SILT FENCE, CHECK DAMS AND INLET PROTECTION DEVICES SHALL BE REMOVED IN A MANNER TO MINIMIZE ADDITIONAL LAND DISTURBANCE. ANY AREAS DISTURBED BY THESE OPERATIONS SHALL BE PROPERLY REVEGATATED. B. LARGE WASTE MATERIALS CREATED BY CUTTING, SAWING, DRILLING, OR OTHER OPERATIONS SHALL BE PROPERLY DISPOSED OF IN SUITABLE WASTE CONTAINERS. THE SITE SHALL BE CHECKED AT THE END OF THE DAY, AS A MINIMUM, AND ALL WASTE MATERIALS, INCLUDING THOSE BLOWN ACROSS OR OFF THE SITE BY WIND SHALL BE PICKED UP AND DISPOSED OF IN SUITABLE CONTAINERS. WHERE POSSIBLE, OPERATIONS SUCH AS SAWING THAT CREATE SMALL PARTICLES SHOULD BE PERFORMED IN ONE SPOT IN AN AREA PROTECTED FROM WIND, AND WASTE PARTICLES COLLECTED AND DISPOSED OF FREQUENTLY TO MINIMIZE WIND DISPERSAL. PACKAGING USED TO TRANSPORT MATERIALS TO THE SITE FOR CONSTRUCTION OF THE FACILITY SHALL BE DISPOSED OF PROPERLY, WHETHER THE MATERIAL IS TAKEN OUT OF ITS PACKAGE AND INCORPORATED INTO THE PROJECT IMMEDIATELY OR STORED ONSITE FOR FUTURE USE. PACKAGED MATERIALS STORED ONSITE SHALL BE INSPECTED REGULARLY AND ANY LOOSE PACKAGING SHALL BE REPAIRED OR DISPOSED OF PROPERLY. C. ALL DEWATERING OF ACTIVITIES SHALL BE DONE IN ACCORDANCE TO GOOD EROSION CONTROL PRACTICES. THESE PRACTICES SHOULD INCLUDE THE USE OF DIRT BAGS SUCH AS SILT FENCE INLET PROTECTION. THE USE OF THESE TYPES OF DEWATERING DEVICES WILL REMOVE LARGE QUANTITIES OF SILT, SEDIMENT, AND DIRT AND PREVENT THESE MATERIALS TO ENTER THE STORM SEWER SYSTEM. D. IF THE USE OF LIME IS USED TO STABILIZE THE SOIL OF THE SITE THEN ALL CONSTRUCTION EQUIPMENT USED SHALL BE CLEANED OF ALL EXCESS MATERIAL WITH WATER IN THE MAINTENANCE AND REFUELING AREA AS SHOWN WITHIN THESE PLANS. E. NUTRIENTS AND FERTILIZERS SHALL ONLY BE USED TO ESTABLISH RAPID VEGETATION. WHEN THESE PRODUCTS ARE UTILIZED, THE USER SHOULD PAY STRICT ATTENTION TO THE PRODUCTS RECOMMENDED USAGE. 3. CONCRETE WASTE WATER A. ALL CONCRETE WASTEWATER SHALL BE DISPOSED OF IN THE DESIGNED AREA AS DIRECTED BY THE CONSTRUCTION MANAGER. THIS AREA IS TO BE A 3' DEEP, 10' SQUARE PIT AS DETAILED ON THE EROSION CONTROL PLAN. THIS AREA SHALL BE INSPECTED ON A DAILY BASIS AT A MINIMUM. WHEN THIS AREA BECOMES FULL, THE POLLUTANTS SHALL BE EXCAVATED, PLACED IN AN ACCEPTABLE CONTAINER AND DISPOSED OF IN PROPER MANNER, BY THE EXCAVATION CONTRACTOR. 4. PAINT PRODUCTS A. ALL EXCESS PAINT AND THEIR RELATED PRODUCTS SHALL BE DISPOSED OF IN THE MANNER AT WHICH THE MANUFACTURER SUGGESTS. UNDER NO CIRCUMSTANCES WILL PAINT OR THEIR RELATED PRODUCTS BE CLEANED OR DISPOSED OF IN SOIL, SANITARY SEWERS, STORM SEWERS OR DETENTION BASINS. ANY VIOLATION OF THIS SHALL BE REPORTED TO THE JOB SUPERINTENDENT. IN THE EVENT OF ACCIDENTALLY CONTAMINATION ALL EFFORTS SHOULD BE MADE TO REMOVE CONTAMINANTS IN AN APPROPRIATE MANNER. THE CITY OF CARMEL FIRE DEPARTMENT SHOULD BE CONTACTED IMMEDIATELY TO DETERMINE IF FURTHER MEASURES ARE NEEDED. 3. SPILLS TO SOIL: A. SPILLS OF HAZARDOUS SUBSTANCES OR EXTREMELY HAZARDOUS SUBSTANCES WHEN THE AMOUNT SPILLED EXCEEDS ONE HUNDRED (100) POUNDS OR THE REPORTABLE QUANTITY, WHICHEVER IS LESS; B. SPILLS OF PETROLEUM WHEN THE AMOUNT SPILLED EXCEEDS FIFTY-FIVE (55) GALLONS; OR C. SPILLS OF OBJECTIONABLE SUBSTANCES AS DEFINED IN SECTION 4(11) OF THIS RULE. 4. ANY SPILL FOR WHICH A SPILL RESPONSE HAS NOT BEEN DONE. (WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-6; FILED FEB 25, 1997, 1:00 P.M.: 20 IR 1733; READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV 21, 2007, 1:16 P.M.: 20071219-IR-327070553BFA) 327 IAC 2-6.1-7 REPORTABLE SPILLS; RESPONSIBILITIES AUTHORITY: IC 13-14-8-7 AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17 SEC. 7. ANY PERSON WHO OPERATES, CONTROLS, OR MAINTAINS ANY MODE OF TRANSPORTATION OR FACILITY FROM WHICH A SPILL OCCURS SHALL, UPON DISCOVERY OF A REPORTABLE SPILL TO THE SOIL OR SURFACE WATERS OF THE STATE, DO THE FOLLOWING: 1. CONTAIN THE SPILL, IF POSSIBLE, TO PREVENT ADDITIONAL SPILLED MATERIAL FROM ENTERING THE WATERS OF THE STATE. 2. UNDERTAKE OR CAUSE OTHERS TO UNDERTAKE ACTIVITIES NEEDED TO ACCOMPLISH A SPILL RESPONSE. 3. AS SOON AS POSSIBLE, BUT WITHIN TWO (2) HOURS OF DISCOVERY, COMMUNICATE A SPILL REPORT TO THE DEPARTMENT OF ENVIRONMENTAL MANAGEMENT, OFFICE OF LAND QUALITY, EMERGENCY RESPONSE SECTION: AREA CODE 1-888-233-7745 FOR IN-STATE CALLS (TOLL FREE), (317) 233-7745 FOR OUT-OF-STATE CALLS. IF NEW OR UPDATED SPILL REPORT INFORMATION BECOMES KNOWN THAT INDICATES A SIGNIFICANT INCREASE IN THE LIKELIHOOD OF DAMAGE TO THE WATERS OF THE STATE, THE RESPONSIBLE PARTY SHALL NOTIFY THE DEPARTMENT AS SOON AS POSSIBLE BUT WITHIN TWO (2) HOURS OF THE TIME THE NEW OR UPDATED INFORMATION BECOMES KNOWN. 4. SUBMIT TO THE INDIANA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT, OFFICE OF LAND QUALITY, EMERGENCY RESPONSE SECTION (MC 66-30), 2525 N. SHADELAND AVE., SUITE 100, INDIANAPOLIS, IN 46219-1787, A WRITTEN COPY OF THE SPILL REPORT IF REQUESTED IN WRITING BY THE DEPARTMENT. 5. EXCEPT FROM MODES OF TRANSPORTATION OTHER THAN PIPELINES, EXERCISE DUE DILIGENCE AND DOCUMENT ATTEMPTS TO NOTIFY THE 6. FOLLOWING: A. FOR SPILLS TO SURFACE WATER THAT CAUSE DAMAGE, THE NEAREST AFFECTED DOWNSTREAM WATER USER LOCATED WITHIN TEN (10) MILES OF THE SPILL AND IN THE STATE OF INDIANA; AND B. FOR SPILLS TO SOIL OUTSIDE THE FACILITY BOUNDARY, THE AFFECTED PROPERTY OWNER OR OWNERS, OPERATOR OR OPERATORS, OR OCCUPANT OR OCCUPANTS. (WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-7; FILED FEB 25, 1997, 1:00 P.M.: 20 IR 1733; READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; ERRATA FILED FEB 6, 2006, 11:15 A.M.: 29 IR 1936; ERRATA FILED OCT 20, 2006, 10:08 A.M.: 20061101-IR-327060497ACA; READOPTED FILED NOV 21, 2007, 1:16 P.M.: 20071219-IR-327070553BFA; ERRATA FILED MAY 27, 2008, 2:06 P.M.: 20080625-IR-327080419ACA) 327 IAC 2-6.1-8 EMERGENCY SPILL RESPONSE ACTIONS AUTHORITY: IC 13-14-8-7 AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17 SEC. 8. NOTWITHSTANDING ANY OTHER SECTION OF THIS RULE, EMERGENCY SPILL RESPONSE ACTIONS TAKE PRECEDENCE OVER REPORTING REQUIREMENTS, AND WHEN EMERGENCY SPILL RESPONSE ACTIVITIES RENDER SPILL REPORTING INCONSISTENT WITH EFFECTIVE RESPONSE ACTIVITIES, COMMUNICATION OF THE SPILL REPORT TO THE INDIANA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT MAY BE DELAYED. IN SITUATIONS WHERE THE SPILL REPORT IS DELAYED, THE BURDEN OF PROVING THE NEED FOR THE DELAY SHALL BE UPON THE RESPONSIBLE PERSON. (WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-8; FILED FEB 25, 1997, 1:00 P.M.: 20 IR 1734; READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV 21, 2007, 1:16 P.M.: 20071219-IR-327070553BFA) 327 IAC 2-6.1-9 COMPLIANCE CONFIRMATION AUTHORITY: IC 13-14-8-7 AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17 SEC. 9. WHEN SPILL REPORTING AND RESPONSE, AS PROVIDED FOR IN THIS RULE, HAS OCCURRED, THE DEPARTMENT SHALL, UPON REQUEST, ISSUE A LETTER CONFIRMING COMPLIANCE WITH THIS RULE AND STATING THAT NO FURTHER ACTION IS REQUIRED UNDER THIS RULE. (WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-9; FILED FEB 25, 1997, 1:00 P.M.: 20 IR 1734; READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV 21, 2007, 1:16 P.M.: 20071219-IR-327070553BFA) SOILS TYPE LEGEND RULE 6. SPILLS OF OIL AND OTHER OBJECTIONABLE SUBSTANCES; REPORTING, CONTAINMENT AND CLEANUP (REPEALED BY WATER POLLUTION CONTROL BOARD; FILED FEB 25, 1997, 1:00 P.M.: 20 IR 1734) RULE 6.1. SPILLS; REPORTING, CONTAINMENT, AND RESPONSE 327 IAC 2-6.1-1 APPLICABILITY AUTHORITY: IC 13-14-8-7 AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17 SEC. 1. THIS RULE APPLIES TO THE REPORTING AND CONTAINMENT OF, AND THE RESPONSE TO THOSE SPILLS OF HAZARDOUS SUBSTANCES, EXTREMELY HAZARDOUS SUBSTANCES, PETROLEUM, AND OBJECTIONABLE SUBSTANCES THAT ARE OF A QUANTITY, TYPE, DURATION AND IN A LOCATION AS TO DAMAGE THE WATERS OF THE STATE. NOTHING IN THIS RULE IS INTENDED TO AFFECT REPORTING OR CLEAN-UP REQUIREMENTS SET FORTH BY OTHER FEDERAL, STATE, OR LOCAL LAWS. (WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-1; FILED FEB 25, 1997, 1:00 P.M.: 20 IR 1731; READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV 21, 2007, 1:16 P.M.: 20071219-IR-327070553BFA) 327 IAC 2-6.1-2 SPECIAL AREAS AUTHORITY: IC 13-14-8-7 AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17 SEC. 2. CERTAIN AREAS OF THE STATE ARE RECOGNIZED AS HAVING UNIQUE GEOLOGY. A LARGE SECTION OF THE MID-SOUTHERN PART OF THE STATE IS A KARST REGION. PORTIONS OF SAINT JOSEPH, ELKHART, KOSCIUSKO, AND LAGRANGE COUNTIES CONTAIN A SOLE SOURCE AQUIFER AS REFERENCED IN 42 U.S.C. 300H-3(E). THE WATERS OF THE STATE ARE PARTICULARLY VULNERABLE TO DAMAGE FROM SPILLS IN THESE AREAS, AND CARE SHOULD BE EXERCISED WHEN EVALUATING DAMAGE FROM SPILLS. INFORMATION ABOUT THESE AREAS CAN BE OBTAINED BY CALLING THE DEPARTMENT OF ENVIRONMENTAL MANAGEMENT, OFFICE OF LAND QUALITY, EMERGENCY RESPONSE SECTION: AREA CODE 1-888-233-7745 FOR IN-STATE CALLS (TOLL FREE), (317) 233-7745 FOR OUT-OF-STATE CALLS. (WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-2; FILED FEB 25, 1997, 1:00 P.M.: 20 IR 1731; READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV 21, 2007, 1:16 P.M.: 20071219-IR-327070553BFA; ERRATA FILED MAY 27, 2008, 2:06 P.M.: 20080625-IR-327080419ACA) 327 IAC 2-6.1-3 EXCLUSIONS AUTHORITY: IC 13-14-8-7 AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17 SEC. 3. NOTWITHSTANDING ANY OTHER SECTION OF THIS RULE, THE REPORTING REQUIREMENT OF THIS RULE DOES NOT APPLY TO THE FOLLOWING OCCURRENCES: 1. DISCHARGES OR EXCEEDANCES THAT ARE UNDER THE JURISDICTION OF AN APPLICABLE PERMIT WHEN THE SUBSTANCE IN QUESTION IS COVERED BY THE PERMIT AND DEATH OR ACUTE INJURY OR ILLNESS TO ANIMALS OR HUMANS DOES NOT OCCUR. 2. LAWFUL APPLICATION OF MATERIALS, INCLUDING, BUT NOT LIMITED TO: A. COMMERCIAL OR NATURAL FERTILIZERS AND PESTICIDES ON OR TO LAND OR WATER; OR B. DUST SUPPRESSION MATERIALS. 3. THE APPLICATION OF PETROLEUM NECESSARY FOR CONSTRUCTION THAT DOES NOT DAMAGE WATERS OF THE STATE. 4. SPILLS OF LESS THAN ONE (1) POUND OR ONE (1) PINT. 5. SPILLS OF INTEGRAL OPERATING FLUIDS, IN THE USE OF MOTOR VEHICLES OR OTHER EQUIPMENT, THE TOTAL VOLUME OF WHICH IS LESS THAN OR EQUAL TO FIFTY-FIVE (55) GALLONS AND WHICH DO NOT DAMAGE WATERS OF THE STATE. 6. OIL SHEENS PRODUCED AS A RESULT OF THE NORMAL OPERATION OF PROPERLY FUNCTIONING WATERCRAFT. 7. A RELEASE OF A SUBSTANCE INTEGRAL TO A SPILL RESPONSE ACTIVITY THAT HAS BEEN APPROVED AND AUTHORIZED BY A STATE OR FEDERAL ONSCENE COORDINATOR. (WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-3; FILED FEB 25, 1997, 1:00 P.M.: 20 IR 1731; ERRATA FILED MAR 7, 1997, 2:25 P.M.: 20 IR 1738; READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV 21, 2007, 1:16 P.M.: 20071219-IR-327070553BFA) NOTE: ALL HOMES SHALL MEET THE LANDSCAPING REQUIREMENTS PER THE ZONING COMMITMENTS. - FINISH GRADE/WATER FLOW - PROPERTY LINE/DRAINAGE SWALE - PERMANENT SEEDING - RIP RAP/GRAVEL DRIVE/EXIT PAD BEEHIVE INLETS (SEE DETAIL) SILT FENCE BOX AROUND CURB INLET PROTECTION (SEE DETAIL) CONSTRUCTION ENTRANCE/EXIT SAMPLE EROSION/SEDIMENT CONTROL PRACTICE PLAN FOR A TYPICAL ONE/TWO FAMILY DWELLING UNDER CONSTRUCTION CURB & GUTTER PROTECTION CURB INLET STREET CENTERLINE 4' CONCRETE WALK SF PS PS 4' CONCRETE WALK PS GARAGE SEEDED AND MULCHED SIDE YARDPS DRAINAGE SWALEHOUSE BY OWNER AT COMPLETION OF CONSTRUCTION (TYP.) PS AREA TO BE TOPSOILED, PS PS DRAINAGE SWALEPS SIDE YARDPS STOCKPILE TOPSOIL SF STOCKPILESUBSOILSF SF PS SF SFDRAINAGE SWALEREAR YARD AREA MAPW S N E PROJECT LOCATION SOILS MAPW S N E EROSION CONTROL PLAN PLAN NOTES 1. THIS PLAN IS DESIGNED TO PREVENT ANY AND ALL SEDIMENT FROM LEAVING THE SITE. THE OWNER SHALL TAKE PREVENTATIVE ACTION IMMEDIATELY. IF NEEDED TO PREVENT EROSION OR LOSS OF SEDIMENT FROM THE SITE. 2. TEMPORARY SEEDING IS TO BE APPLIED TO ANY GRADED AREA THAT WILL REMAIN UNALTERED FOR AN EXTENDED PERIOD OF TIME. 3. PERMANENT SEEDING IS TO BE APPLIED IMMEDIATELY TO AREAS THAT HAVE ACHIEVED FINAL AND FINISHED GRADE. 4. PRESERVE EXISTING VEGETATION ON THE SITE WHENEVER AND WHEREVER POSSIBLE TO PREVENT TOPSOIL EROSION. 5. ALL SEDIMENT CAPTURING MEASURES ARE TO BE IMPLEMENTED PRIOR TO THE DISTURBANCE OF THE CONSTRUCTION AREA THEY ARE INTENDED TO SERVICE. 6. ALL EROSION CONTROL MEASURES ARE TO BE PROPERLY MAINTAINED TO CONTINUE THEIR EFFECTIVENESS. 7. IF GRADING OCCURS DURING DECEMBER, JANUARY OR FEBRUARY, DORMANT SEEDING PROCEDURES SHALL BE USED. 8. DURING DRY WEATHER, KEEP LAWNS WATERED BY APPROVED METHODS. RESEED ANY AREAS NOT GERMINATING OR DAMAGED AT INTERVALS AS MAY BE REQUIRED ACCORDING TO SEASONAL CONDITIONS AND/OR CONSTRUCTION ACTIVITY. WATER GRASS AND EXECUTE NECESSARY WEEDING UNTIL FULL STAND OF GRASS HAS BEEN OBTAINED. 9. THE IMPLEMENTATION AND MAINTENANCE OF THE EROSION CONTROL IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER. 10. IT SHALL BE THE CONTRACTOR'S AND/OR OWNER'S RESPONSIBILITY TO MINIMIZE SEDIMENTATION FROM ON-SITE CONSTRUCTION ACTIVITIES FROM BEING DEPOSITED ONTO ADJACENT PROPERTIES AND RECEIVING STREAMS/DITCHES IN STRICT COMPLIANCE WITH "RULE 5" (327 IAC 15-5, CONSTRUCTION ACTIVITY STORMWATER RUNOFF CONTROL).IT SHALL ALSO BE THE CONTRACTOR'S OR OWNER'S RESPONSIBILITY TO OBTAIN ANY APPROVALS REQUIRED FROM THE LOCAL AUTHORITY AND TO SUBMIT A COMPLETE NOTICE OF INTENT LETTER TO THE OFFICE OF WATER MANAGEMENT, INDIANA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT PRIOR TO ANY CONSTRUCTION ACTIVITY. 11. PROVIDE - #2 CRUSHED STONE CONSTRUCTION ENTRANCE(S) TO SITE FROM STREETS/ROADS. 12. IT SHALL BE THE CONTRACTOR'S AND/OR OWNER'S RESPONSIBILITY TO IMPLEMENT AN EROSION CONTROL PLAN FOR EACH LOT, THE BUILDER MAY IMPLEMENT A DIFFERENT EROSION CONTROL PLAN AS LONG AS IT MEETS OR EXCEEDS RULE 5 REGULATIONS. INDIVIDUAL LOT EROSION CONTROL PLAN LEGEND Know what'sbelow. before you dig.Call R NO SCALE 327 IAC 2-6.1-4 DEFINITIONS AUTHORITY: IC 13-14-8-7 AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17; IC 14-8-2-7; IC 14-25-7-13; IC 14-25-7-15 SEC. 4. IN ADDITION TO THE DEFINITIONS CONTAINED IN IC 13-11-2-17(D), IC 13-11-2-35(A), IC 13-11-2-51, IC 13-11-2-158(A), IC 13-11-2-160, IC 13-11-2-260, IC 13-11-2-265, AND IN 327 IAC 1, THE FOLLOWING DEFINITIONS APPLY THROUGHOUT THIS RULE: 1. "ANIMAL" MEANS ALL MAMMALS, BIRDS, REPTILES, AMPHIBIANS, FISH, CRUSTACEANS, AND MOLLUSKS. 2. "AQUATIC LIFE" MEANS THOSE PLANTS AND MACROINVERTEBRATES THAT ARE DEPENDENT UPON AN AQUATIC ENVIRONMENT. 3. "CONTAIN" MEANS TO TAKE SUCH IMMEDIATE ACTION AS NECESSARY TO DAM, BLOCK, RESTRAIN, OR OTHERWISE ACT TO MOST EFFECTIVELY PREVENT A SPILL FROM ENTERING WATERS OF THE STATE OR MINIMIZE DAMAGE TO THE WATERS OF THE STATE FROM A SPILL. 4. "DAMAGE" MEANS THE ACTUAL OR IMMINENT ALTERATION OF THE WATERS OF THE STATE SO AS TO RENDER THE WATERS HARMFUL, DETRIMENTAL, OR INJURIOUS TO: A. PUBLIC HEALTH, SAFETY, OR WELFARE; B. DOMESTIC, COMMERCIAL, INDUSTRIAL, AGRICULTURAL, OR RECREATIONAL USES; OR C. ANIMALS OR AQUATIC LIFE. 5. "DOWNSTREAM WATER USER" MEANS: A. A COMMUNITY PUBLIC WATER SUPPLY, AS IDENTIFIED BY THE DEPARTMENT OF NATURAL RESOURCES UNDER IC 14-25-7-13(D); B. A SIGNIFICANT WATER WITHDRAWAL FACILITY AS REGISTERED WITH THE DEPARTMENT OF NATURAL RESOURCES UNDER IC 14-25-7-15; C. USERS OF RECREATIONAL WATERS; OR D. ANY OTHER USER MADE KNOWN TO THE PERSON WHO HAS A SPILL. 6. "EXTREMELY HAZARDOUS SUBSTANCE" MEANS A SUBSTANCE IDENTIFIED PURSUANT TO 42 U.S.C. 11002 AND 11004. (40 CFR 355 APPENDIX A.) 7. "FACILITY" MEANS ALL LAND, BUILDINGS, EQUIPMENT, STRUCTURES, AND OTHER STATIONARY ITEMS THAT ARE LOCATED ON A SINGLE SITE OR ON CONTIGUOUS SITES AND THAT ARE OWNED OR OPERATED BY THE SAME PERSON OR BY ANY PERSON WHO CONTROLS, IS CONTROLLED BY, OR IS UNDER COMMON CONTROL WITH, SUCH PERSON. 8. "FACILITY BOUNDARY" MEANS THE BOUNDARY OF A FACILITY OR AN EASEMENT OR RIGHT-OF-WAY. 9. "HAZARDOUS SUBSTANCE" HAS THE MEANING SET FORTH IN 42 U.S.C. 9601(14). 10. "MODE OF TRANSPORTATION" INCLUDES, BUT IS NOT LIMITED TO, CARRIAGE BY: A. RAIL AND MOTOR VEHICLES; B. AIRCRAFT; C. WATERCRAFT; D. PIPELINES; OR E. OTHER MEANS OF TRANSPORTATION; IN COMMERCE. THIS DEFINITION EXCLUDES CARRIAGE WITHIN A FACILITY BY TRANSPORTATION EQUIPMENT OWNED, OPERATED, OR CONTROLLED BY THAT FACILITY. 11. "OBJECTIONABLE SUBSTANCES" MEANS SUBSTANCES THAT ARE: A. OF A QUANTITY AND A TYPE; AND B. PRESENT FOR A DURATION AND IN A LOCATION; SO AS TO DAMAGE WATERS OF THE STATE. THIS DEFINITION EXCLUDES HAZARDOUS SUBSTANCES, EXTREMELY HAZARDOUS SUBSTANCES, PETROLEUM, AND MIXTURES THEREOF. 12. "ON-SCENE COORDINATOR" MEANS A STATE OR FEDERAL OFFICIAL DESIGNATED BY THE DEPARTMENT, THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY, OR THE UNITED STATES COAST GUARD TO DIRECT AND COORDINATE SPECIAL SPILL RESPONSE ACTIVITIES. 13. "RECREATIONAL WATERS" MEANS ANY WATER USED FOR: A. BOATING, SWIMMING, FISHING, HUNTING, TRAPPING, OR WILDLIFE VIEWING; OR B. PUBLIC ACCESS AREAS THAT ARE OWNED BY THE DEPARTMENT OF NATURAL RESOURCES OR THE FEDERAL GOVERNMENT; AS LISTED BY THE DEPARTMENT. 14. "REPORTABLE QUANTITY" MEANS THE AMOUNT OF A HAZARDOUS SUBSTANCE OR EXTREMELY HAZARDOUS SUBSTANCE THAT IS REQUIRED TO BE REPORTED UNDER FEDERAL LAW UNDER 42 U.S.C. 9602(A) AND (B) AND 42 U.S.C. 9603(A). (40 CFR 302.4 OR 40 CFR 355 APPENDIX A.) 15. "SPILL" MEANS ANY UNEXPECTED, UNINTENDED, ABNORMAL, OR UNAPPROVED DUMPING, LEAKAGE, DRAINAGE, SEEPAGE, DISCHARGE OR OTHER LOSS OF PETROLEUM, HAZARDOUS SUBSTANCES, EXTREMELY HAZARDOUS SUBSTANCES, OR OBJECTIONABLE SUBSTANCES. THE TERM DOES NOT INCLUDE RELEASES TO IMPERMEABLE SURFACES WHEN THE SUBSTANCE DOES NOT MIGRATE OFF THE SURFACE OR PENETRATE THE SURFACE AND ENTER THE SOIL. 16. "SPILL RESPONSE", FOR PURPOSES OF THIS RULE, MEANS THE FOLLOWING: A. THE SPILL IS CONTAINED; AND B. FREE MATERIAL IS REMOVED OR NEUTRALIZED. 17. "SPILL REPORT" MEANS AN ORAL REPORT THAT INCLUDES THE FOLLOWING INFORMATION ABOUT A SPILL, TO THE EXTENT THAT THE INFORMATION IS KNOWN AT THE TIME OF THE REPORT: A. THE NAME, ADDRESS, AND TELEPHONE NUMBER OF THE PERSON MAKING THE SPILL REPORT. B. (THE NAME, ADDRESS, AND TELEPHONE NUMBER OF A CONTACT PERSON IF DIFFERENT FROM CLAUSE (A). C. THE LOCATION OF THE SPILL. D. THE TIME OF THE SPILL. E. THE IDENTIFICATION OF THE SUBSTANCE SPILLED. F. THE APPROXIMATE QUANTITY OF THE SUBSTANCE THAT HAS BEEN OR MAY FURTHER BE SPILLED. G. THE DURATION OF THE SPILL. H. THE SOURCE OF THE SPILL. I. NAME AND LOCATION OF THE WATERS DAMAGED. J. THE IDENTITY OF ANY RESPONSE ORGANIZATION RESPONDING TO THE SPILL. K. WHAT MEASURES HAVE BEEN OR WILL BE UNDERTAKEN TO PERFORM A SPILL RESPONSE. L. ANY OTHER INFORMATION THAT MAY BE SIGNIFICANT TO THE RESPONSE ACTION. 18. "WATERS", AS DEFINED IN IC 13-11-2-265, MEANS THE ACCUMULATIONS OF WATER, SURFACE AND UNDERGROUND, NATURAL AND ARTIFICIAL, PUBLIC AND PRIVATE, OR PARTS THEREOF, THAT ARE WHOLLY OR PARTIALLY WITHIN, FLOW THROUGH, OR BORDER UPON THIS STATE. THE TERM DOES NOT INCLUDE ANY PRIVATE POND OR ANY OFF-STREAM POND, RESERVOIR, OR FACILITY BUILT FOR REDUCTION OR CONTROL OF POLLUTION OR COOLING OF WATER PRIOR TO DISCHARGE UNLESS THE DISCHARGE FROM THE POND, RESERVOIR, OR FACILITY CAUSES OR THREATENS TO CAUSE WATER POLLUTION. (WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-4; FILED FEB 25, 1997, 1:00 P.M.: 20 IR 1731; ERRATA FILED MAR 7, 1997, 2:25 P.M.: 20 IR 1738; READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV 21, 2007, 1:16 P.M.: 20071219-IR-327070553BFA) 327 IAC 2-6.1-5 REPORTABLE SPILLS; FACILITY AUTHORITY: IC 13-14-8-7 AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17 SEC. 5. THE FOLLOWING SPILLS FROM A FACILITY MUST BE REPORTED: 1. SPILLS THAT DAMAGE THE WATERS OF THE STATE SO AS TO CAUSE DEATH OR ACUTE INJURY OR ILLNESS TO HUMANS OR ANIMALS. 2. SPILLS FROM A FACILITY THAT HAS BEEN NOTIFIED IN WRITING BY A WATER UTILITY THAT IT IS LOCATED IN A DELINEATED PUBLIC WATER SUPPLY WELLHEAD PROTECTION AREA AS APPROVED BY THE DEPARTMENT UNDER 327 IAC 8-4.1 THAT ARE: A. SPILLS OF HAZARDOUS SUBSTANCES OR EXTREMELY HAZARDOUS SUBSTANCES WHEN THE AMOUNT SPILLED EXCEEDS ONE HUNDRED (100) POUNDS OR THE REPORTABLE QUANTITY, WHICHEVER IS LESS; B. SPILLS OF PETROLEUM WHEN THE AMOUNT SPILLED EXCEEDS FIFTY-FIVE (55) GALLONS; OR C. SPILLS OF OBJECTIONABLE SUBSTANCES AS DEFINED IN SECTION 4(11) OF THIS RULE. 3. SPILLS THAT DAMAGE WATERS OF THE STATE AND THAT: A. ARE LOCATED WITHIN FIFTY (50) FEET OF A KNOWN PRIVATE DRINKING WATER WELL LOCATED BEYOND THE FACILITY PROPERTY BOUNDARY; OR B. ARE LOCATED WITHIN ONE HUNDRED (100) YARDS OF: · ANY HIGH QUALITY WATER DESIGNATED AS AN OUTSTANDING STATE RESOURCE PURSUANT TO 327 IAC 2-1-2(3), EXCLUDING LAKE MICHIGAN; · ANY WATER DESIGNATED AS EXCEPTIONAL USE PURSUANT TO 327 IAC 2-13(A)(6) [SIC., 327 IAC 2-1-3(A)(6)] AND 327 IAC 2-1-11(B); · ANY WATER DESIGNATED AS CAPABLE OF SUPPORTING A SALMONID FISHERY PURSUANT TO 327 IAC 2-1-6(C)(1), EXCEPT LAKE MICHIGAN; OR · ANY WATER THAT IS A FISH HATCHERY, FISH AND WILDLIFE AREA, NATURE PRESERVE, OR RECREATIONAL WATER OWNED BY THE DEPARTMENT OF NATURAL RESOURCES OR THE FEDERAL GOVERNMENT. 4. FOR ANY SPILL WHICH DOES NOT MEET THE CRITERIA IN SUBDIVISIONS (1) THROUGH (3), THE FOLLOWING MUST BE REPORTED: A. SPILLS TO SURFACE WATERS: · SPILLS OF HAZARDOUS SUBSTANCES OR EXTREMELY HAZARDOUS SUBSTANCES WHEN THE AMOUNT SPILLED EXCEEDS ONE HUNDRED (100) POUNDS OR THE REPORTABLE QUANTITY, WHICHEVER IS LESS; · SPILLS OF PETROLEUM OF SUCH QUANTITY AS TO CAUSE A SHEEN UPON THE WATERS;OR · SPILLS OF OBJECTIONABLE SUBSTANCES AS DEFINED IN SECTION 4(11) OF THIS RULE. B. SPILLS TO SOIL BEYOND THE FACILITY BOUNDARY: · SPILLS OF HAZARDOUS SUBSTANCES OR EXTREMELY HAZARDOUS SUBSTANCES WHEN THE AMOUNT SPILLED EXCEEDS ONE HUNDRED (100) POUNDS OR THE REPORTABLE QUANTITY, WHICHEVER IS LESS; · SPILLS OF PETROLEUM WHEN THE AMOUNT SPILLED EXCEEDS FIFTY-FIVE (55) GALLONS;OR · SPILLS OF OBJECTIONABLE SUBSTANCES AS DEFINED IN SECTION 4(11) OF THIS RULE. C. SPILLS TO SOIL WITHIN THE FACILITY BOUNDARY: · SPILLS OF HAZARDOUS SUBSTANCES OR EXTREMELY HAZARDOUS SUBSTANCES WHEN THE AMOUNT SPILLED EXCEEDS THE REPORTABLE QUANTITY; · SPILLS OF PETROLEUM WHEN THE SPILLED AMOUNT EXCEEDS ONE THOUSAND (1,000) GALLONS; OR · SPILLS OF OBJECTIONABLE SUBSTANCES AS DEFINED IN SECTION 4(11) OF THIS RULE. 5. ANY SPILL FOR WHICH A SPILL RESPONSE HAS NOT BEEN DONE. (WATER POLLUTION CONTROL BOARD; 327 IAC 2-6.1-5; FILED FEB 25, 1997, 1:00 P.M.: 20 IR 1732; ERRATA FILED MAR 7, 1997, 2:25 P.M.: 20 IR 1738; READOPTED FILED JAN 10, 2001, 3:23 P.M.: 24 IR 1518; READOPTED FILED NOV 21, 2007, 1:16 P.M.: 20071219-IR-327070553BFA) 327 IAC 2-6.1-6 REPORTABLE SPILLS; TRANSPORTATION AUTHORITY: IC 13-14-8-7 AFFECTED: IC 13-11-2; IC 13-18-1; IC 13-18-3; IC 13-18-8; IC 13-18-17 SEC. 6. THE FOLLOWING SPILLS FROM A MODE OF TRANSPORTATION MUST BE REPORTED: 1. SPILLS THAT DAMAGE THE WATERS OF THE STATE SO AS TO CAUSE DEATH OR ACUTE INJURY OR ILLNESS TO HUMANS OR ANIMALS. 2. SPILLS THAT DAMAGE SURFACE WATERS. SF SF C202SWPPP SPECIFICATIONS & DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C202 SWPPP Specs & Details.dwgLAYOUT: C202DATE/TIME: August 31, 2022 - 10:48amPLOTTED BY: hansenbfhgENGINE E RS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaSECTION 1 - EMERGENCY RESPONSE NUMBERS EMERGENCY FOR ANY LIFE THREATENING PROBLEM 911 CITY OF CARMEL FIRE DEPARTMENT 317-571-2600 CITY OF CARMEL POLICE DEPARTMENT 317-571-2500 INDIANA DEPT. OF NATURAL RESOURCES 812-477-8773 INDIANA DEPT. OF ENVIRONMENTAL MANAGEMENT 317-233-7745 HAMILTON COUNTY SOIL AND WATER 317-773-1406 CITY OF CARMEL ENGINEERING 317-571-2441 SOIL SERIES YbvA YclA YmsB2 YmsC2 YpaA W DESCRIPTION Brookston silty clay loam - Urban land complex - 0 to 2 percent slopes Crosby silt loam, fine loamy subsoil - Urban land complex - 0 to2 percent slopes Miami silt loam - Urban land complex - 2 to 6 percent slopes, eroded Patton silty clay loam - Urban land complex - 0 to 2 percent slopes Water Miami silt loam - Urban land complex - 6 to 12 percent slopes, eroded CONTACT PERSON FOR EROSION CONTROL & SEDIMENT PRACTICES LESS IMPACT DEVELOPMENT 8910 PURDUE ROAD, SUITE 425 INDIANAPOLIS, INDIANA 46268 TELEPHONE: (317) 816-1230 CONTACT PERSON: SCOTT SCHUTZ EMAIL: SCOTT@EQUITEAMLLC.COM C202 SWPPP SPECSSWPPP FOR CONSTRUCTION SITES 1. HYDROLOGIC UNIT CODE (14 DIGIT) - 05120201090060 2. IDENTIFICATION OF ALL RECEIVING WATERS - WILLIAMS CREEK 3. PRE-CONSTRUCTION AND POST-CONSTRUCTION ESTIMATE OF PEAK DISCHARGE (10 YEAR) - Q10 PRE 9.95 CFS, Q10 POST 1.01 CFS 4. SPECIFIC POINTS WHERE STORMWATER DISCHARGE LEAVES SITE - SEE STORMWATER POLLUTION PREVENTION PLAN, SHEET C201. STORMWATER WILL BE CHANNELED INTO ENCLOSED STORM SEWERS, WHERE IT WILL THEN PASS THROUGH ONSITE DETENTION. WATER LEAVES THE SITE THROUGH AN OUTLET CONTROL STRUCTURE. 5. IDENTIFICATION OF POTENTIAL DISCHARGE TO GROUND WATER - THERE MAY BE SOME DISCHARGE INTO THE GROUND WATER FROM THE DRAINAGE POND. 6. SOILS MAP W/ SOIL DESCRIPTIONS AND LIMITATIONS - SEE BOTTOM RIGHT OF THIS SHEET 7. DESCRIPTION OF POTENTIAL POLLUTANT SOURCES - POTENTIAL POLLUTANTS FROM POST-CONSTRUCTION ACTIVITY SUCH AS SANDS AND SALTS FROM SNOW REMOVAL; OIL, GREASE, ANTIFREEZE, ETC. FROM VEHICLES INCLUDING HEAVY METAL FROM BRAKE PAD WEAR SHOULD BE PROPERLY ATTENDED TO TO REDUCE THE CONTAMINANTS FROM ENTERING THE STORM SYSTEM. TRASH SHOULD BE CLEANED UP TO REDUCE CLOGGING OF STORM SYSTEMS AND REDUCE POTENTIAL BACTERIA AND/OR OTHER BIOLOGICAL AGENTS FROM ENTERING IN THE STORM SYSTEM. EXCESS FERTILIZERS AND HERBICIDES SHOULD BE AVOIDED. CLEAN UP IMMEDIATELY IF ANY IS SPILLED. 8. TEMPORARY AND PERMANENT STORMWATER QUALITY MEASURES - A. LOCATION - SEE SHEET C200 & C201. EACH INLET WILL HAVE TEMPORARY SEDIMENT TRAPS WITH OVERFLOW THROUGHOUT CONSTRUCTION. B. DIMENSION - SEE SHEET C203 FOR TEMPORARY INLET PROTECTION. C. DETAILED SPECIFICATIONS - SEE SHEETS C202, C203 & C204. D. CONSTRUCTION DETAILS - SEE SHEETS C202, C203 & C204. E. MONITOR AND MAINTENANCE GUIDELINES - SEE O&M MANUAL NOTE: AS REQUIRED IN "RULE 5," SELF-MONITORING INSPECTIONS TO BE COMPLETED AT A MINIMUM OF ONCE PER WEEK AND WITHIN 24 HOURS OR THE NEXT BUSINESS DAY OF 12" RAIN OR GREATER BY A QUALIFIED INSPECTOR. INSPECTIONS MUST BE RETAINED FOR RECORDS THROUGHOUT THE LIFE OF THE PROJECT AND PROVIDED WITHIN 48 HOURS OF A REQUEST FROM A REGULATING AUTHORITY. 9. GENERAL CONSTRUCTION SEQUENCE - A. A PRE-CONSTRUCTION MEETING WITH CITY OF CARMEL ENGINEERING AND SWCD IS REQUIRED PRIOR TO THE COMMENCEMENT OF ANY EARTHWORK. ADDITIONALLY, IDEM IS REQUIRED TO BE CONTACTED AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. B. POSTING AREA- CONTRACTOR TO POST APPROVED SWPPP DOCUMENTS AND PERMITS IN LOCATION SHOWN ON PLANS. C. CONSTRUCTION ENTRANCE- STRIP TOPSOIL AND PLACE STONE AT ACCESS POINT D. INSTALL PERIMETER BMP'S SUCH AS SILT FENCING AND OFF-SITE TEMPORARY BMP'S. E. EARTHWORK- STRIP TOPSOIL, BEGIN ROUGH GRADING, EXCAVATE POND AND PLACE DIRT ON STOCKPILE, FINISH GRADE AND SEED POND, INSTALL STORM STRUCTURES 631-633 AND POND OUTLET STRUCTURE, REMOVE ABANDONED PORTION OF HINSHAW-HENLEY DRAIN, FINISH GRADE SLOPES AND SWALES. TEMPORARY SEED ALL DISTURBED AREAS, ON-SITE AND OFF-SITE, THAT SHALL REMAIN UN-WORKED FOR MORE THAN 14 DAYS. F. SANITARY SEWER- INSTALL SEWER SYSTEM. G. STORM SEWER- INSTALL STORM SEWERS SYSTEM AND INLET PROTECTION AS STORM INLETS ARE COMPLETED. H. UTILITIES- COORDINATE INSTALLATION OF WATER, GAS, TELEPHONE, ELECTRIC AND OTHER REQUIRED UTILITY LINES. I. CLEANUP - CONTRACTOR SHALL SPOIL ALL EXCESS MATERIALS, RE-GRADE AND STABILIZE ALL AREAS DISTURBED BY UTILITY INSTALLATIONS AND RESEED. J. FINAL GRADING AND PERMANENT EROSION CONTROL- FINISH GRADE AND PERMANENTLY SEED ALL PROPERTY PERIMETER AREAS. REMOVE TEMPORARY SEDIMENT BASINS AND DIVERSION DITCHES. TEMPORARY SEDIMENT BASINS AND DIVERSION DITCHES TO REMAIN IN OFFSITE AREA. K. PAVEMENT- INSTALL STONE, BASE COURSES AND FINISHED GRADES FOR ROADWAYS, CURBS AND ENTRY DRIVES. L. TEMPORARY SEED ALL DISTURBED AREAS. M. FINAL LANDSCAPING- FINAL GRADE AND INSTALL LANDSCAPING. N. FINAL SEEDING- COMPLETE FINAL SEEDING. O. MAINTENANCE- MAINTAIN ALL EROSION AND SEDIMENT CONTROL PRACTICES UNTIL ALL DISTURBED AREAS ARE PERMANENTLY STABILIZED. P. IN THE EVENT THAT THE NATIONAL WEATHER SERVICE FORECASTS RAIN TO OCCUR WITHIN 24 HOURS OF THE END OF A WORK DAY, THE CONTRACTOR SHALL STABILIZE THE SITE BEFORE LEAVING AT THE END OF THE WORK DAY. 10. LOCATIONS OF PROPOSED SOIL STOCKPILES AND/OR BORROW/DISPOSAL AREAS - SEE SHEET C200. 11. TEMPORARY SURFACE STABILIZATION METHOD FOR EACH SEASON - SEE SEASONAL SOIL PROTECTION CHART ON SHEET C203. 12. EROSION AND SEDIMENT CONTROL SPECIFICATIONS FOR EACH INDIVIDUAL BUILDING LOT - SEE BOTTOM RIGHT CORNER OF THIS SHEET. 13. MATERIAL HANDLING AND SPILL PREVENTION PLAN THIS MATERIAL HANDLING AND SPILL PREVENTION PLAN IS BASED UPON REQUIREMENTS SET FORTH IN THE INDIANA ADMINISTRATIVE CODE, SECTION 327 IAC 2-6-1. THE FULL TEXT OF THIS CODE CAN BE FOUND ON THIS SHEET POTENTIAL POLLUTANTS ON SITE MAY INCLUDE VEHICLE LUBRICANTS, OILS, VEHICULAR FUELS, CONCRETE WASH-OUT, MULCH, PESTICIDES, HERBICIDES, FERTILIZER, AND TRASH. FUELS, OILS, AND GASOLINE CAN LEAK OR BE SPILLED FROM TRUCKS AND CONSTRUCTION EQUIPMENT WHICH COULD FIND THEIR WAY TO LITTLE COOL CREEK. FOLLOW MATERIAL SAFETY DATA SHEETS (MSDS) FOR CONTAMINANTS ON-SITE. IT IS IMPORTANT THAT ALL MANUFACTURER'S INSTRUCTIONS BE FOLLOWED WHEN USING OR APPLYING ALL FERTILIZERS, HERBICIDES, AND PESTICIDES. SMALL SPILLS AND LEAKS OF THESE MATERIALS ONTO NON-PAVED AREAS WILL BE SHOVELED INTO CONTAINERS OR DUMPSTERS FOR PROPER DISPOSAL. EMERGENCY RESPONSE NUMBERS: RESPONSE FOR ANY LIFE THREATENING PROBLEM: 911 CARMEL FIRE DEPARTMENT: (317) 571-2600 CARMEL POLICE DEPARTMENT: (317) 571-2500 INDIANA DEPARTMENT OF NATURAL RESOURCES: (812) 477-8773 IDEM SPILL RESPONSE CENTER: (317) 233-7745 NATIONAL RESPONSE CENTER (800)-424-8802 CONTRACTOR SHALL CONTACT A WASTE RECOVERY AGENCY IMMEDIATELY FOR REMOVAL OF CONTAMINATES AND COORDINATION OF MONITORING THE SITE DURING CLEANUP UNTIL ALL OF THE HAZARDOUS MATERIAL HAS BEEN REMOVED. CONTRACTOR SHALL COOPERATE WITH IDEM DURING AND AFTER THE SPILL TO INSURE ALL REQUIRED CLEANUP AND FILING REPORTS ARE PROPERLY SUBMITTED. THE DEVELOPER SHALL BE CONTINUALLY INFORMED OF ANY CONTAMINATION CONCERNS OCCURRING ON THE SITE. THE CONSTRUCTION MANAGER SHALL KEEP ON SITE A LIST OF QUALIFIED CONTRACTORS FOR SPILL REMEDIATION. ALL SITE PERSONNEL, INCLUDING MAINTENANCE EMPLOYEES, SHALL BE MADE AWARE OF PROPER SPILL PREVENTION AND REMEDIATION TECHNIQUES. ALL MATERIALS USED TO ABSORB SPILLS SHALL BE PROPERLY DISPOSED OF IN AN APPROVED MANNER IN COMPLIANCE WITH LOCAL AND STATE LAWS. DO NOT FLUSH SPILL MATERIALS WITH WATER UNLESS DIRECTED TO DO SO BY A GOVERNING AGENCY. 14. CONTACT INFORMATION FOR TRAINED INDIVIDUAL RESPONSIBLE FOR STORM WATER POLLUTION PREVENTION FOR THE PROJECT SITE - SEE THIS SHEET FOR INFORMATION 15. CURRENT REVISION DATE ON ALL SHEETS - SEE TITLE BLOCK SWPPP FOR POST CONSTRUCTION 1. DESCRIPTION OF POLLUTANTS AND THEIR SOURCES ASSOCIATED WITH THE PROPOSED LAND USE - POTENTIAL POLLUTANTS FROM POST-CONSTRUCTION ACTIVITY SUCH AS SANDS AND SALTS FROM SNOW REMOVAL; OIL, GREASE, ANTIFREEZE, ETC. FROM VEHICLES INCLUDING HEAVY METAL FROM BRAKE PAD WEAR SHOULD BE PROPERLY ATTENDED TO TO REDUCE THE CONTAMINANTS FROM ENTERING THE STORM SYSTEM. TRASH SHOULD BE CLEANED UP TO REDUCE CLOGGING OF STORM SYSTEMS AND REDUCE POTENTIAL BACTERIA AND/OR OTHER BIOLOGICAL AGENTS FROM ENTERING IN THE STORM SYSTEM. EXCESS FERTILIZERS AND HERBICIDES SHOULD BE AVOIDED. CLEAN UP IMMEDIATELY IF ANY IS SPILLED. 2. POST-CONSTRUCTION STORMWATER QUALITY MEASURES - A. LOCATION - STRUCTURE WQ601 TO BE A WATER QUALITY STRUCTURE, THE WET POND WITH NATIVE BANKS IS LOCATED ON THE WEST SIDE OF THE SITE, SEE SHEET C201. B. DIMENSIONS - WQ 601 IS A CONTECH CS-8, POND HAS A NORMAL POOL AREA OF 0.94 ACRES, SEE SHEETS C201, C202, C203 & C204. C. SIZING CALCULATIONS - SEE DRAINAGE REPORT D. DETAILED SPECIFICATIONS - SEE SHEETS C202, C203 & C204. E. CONSTRUCTION DETAILS - SEE SHEETS C202, C203 & C204. 3. SEQUENCE DESCRIBING STORMWATER QUALITY MEASURE IMPLEMENTATION-SEE CONSTRUCTION SEQUENCE, C202. 4. STORMWATER QUALITY MEASURES TO BE IMPLEMENTED TO PREVENT OR MINIMIZE ADVERSE IMPACTS TO STREAM OR RIPARIAN HABITATS - SEE STORMWATER POLLUTION PREVENTION PLAN, SHEET C200 & C201. THE MAJORITY OF THE STORMWATER WILL BE CHANNELED THROUGH ENCLOSED STORM PIPE INTO A DETENTION POND WITH A WATER QUALITY OUTLET STRUCTURE. ROUTINE INSPECTIONS SHOULD OCCUR EVERY 6 MONTHS BY THE OWNER. MAINTENANCE: 1. CHECK OIL & SEDIMENT DEPTH. THIS SHOULD OCCUR AFTER EVERY MAJOR RAIN EVENT. -MAINTENANCE SHOULD OCCUR AT 15% OF TOTAL STORAGE FOR SEDIMENT OR 8" OF SEDIMENT DEPTH. -IF AN OIL SPILL OCCURS, MAINTAIN IMMEDIATELY. MAINTENANCE SHOULD OCCUR BY A LICENSED LIQUID WASTE HAULER. NOTIFY LOCAL REGULATORY AGENCY AS REQUIRED ON SPILL REPORTING CHART UPPER RIGHT OF THIS SHEET. 11/07/22 10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C202 SWPPP Specs & Details.dwgLAYOUT: C203DATE/TIME: August 31, 2022 - 10:48amPLOTTED BY: hansenbfhgENGINE E RS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaWOOD OR METAL STAKES TO SECURE THE STRAW BALES (TWO PER BALE) 10' MIN.VARIES10 MIL. PLASTIC LINING STRAW BALE (TYP) SECTION LINE STRAW BALE (TYP) BINDING WIRE WOOD OR METAL STAKES (TYP) - 2 PER BALENATIVE MATERIAL (OPTIONAL) POLYETHYLENE LINING 10 MIL. EXTENDING OVER BALES (NO SCALE)TYPE "ABOVE GRADE W/ STRAW BALES"4"WOOD OR METAL STAKES TO SECURE THE STRAW BALES (TWO PER BALE) POLYETHYLENE LINING 10 MIL. EXTENDING OVER BALES METAL PINS OR STAPLES TO SECURE THE POLYETHYLENE LINING TO THE STRAW BALES METAL PINS OR STAPLES TO SECURE THE POLYETHYLENE LINING TO THE STRAW BALES CONCRETE WASHOUT WOOD POST 3"x3"x8' BLACK LETTER 6" HEIGHT 3/8" TREATED PLYWOOD 48"x24" PAINTED WHITE 0.5" LAG SCREWS INSTALLATION 1. UTILIZE AND FOLLOW THE DESIGN IN THE STORM WATER POLLUTION PREVENTION PLAN TO INSTALL THE SYSTEM. 2. DEPENDENT UPON THE TYPE OF SYSTEM, EITHER EXCAVATE THE PIT OR INSTALL THE CONTAINMENT SYSTEM. 3. A BASE SHALL BE CONSTRUCTED AND PREPARED THAT IS FREE OF ROCKS AND OTHER DEBRIS THAT MAY CAUSE TEARS OR PUNCTURES IN THE POLYETHYLENE LINING. 4. INSTALL THE POLYETHYLENE LINING. FOR EXCAVATED SYSTEMS, THE LINING SHOULD EXTEND OVER THE ENTIRE EXCAVATION. THE LINING FOR BERMED SYSTEMS SHOULD BE INSTALLED OVER THE POOLING AREA WITH ENOUGH MATERIAL TO EXTEND THE LINING OVER THE BERM OR CONTAINMENT SYSTEM. THE LINING SHOULD BE SECURED WITH PINS, STAPLES, OR OTHER FASTENERS. 5. PLACE FLAGS, SAFETY FENCING, OR EQUIVALENT TO PROVIDE A BARRIER TO CONSTRUCTION EQUIPMENT AND OTHER TRAFFIC. 6. PLACE A NON-COLLAPSING, NON-WATER HOLDING COVER OVER THE WASHOUT FACILITY PRIOR TO A PREDICTED RAINFALL EVENT TO PREVENT ACCUMULATION OF WATER AND POSSIBLE OVERFLOW OF THE SYSTEM (OPTIONAL). 7. INSTALL SIGNAGE THAT IDENTIFIES CONCRETE WASHOUT AREAS. 8. POST SIGNS DIRECTING CONTRACTORS AND SUPPLIERS TO DESIGNATED LOCATIONS. 9. WHERE NECESSARY, PROVIDE STABLE INGRESS AND EGRESS (SEE TEMPORARY CONSTRUCTION INGRESS/EGRESS PAD ON PAGE 17) OR ALTERNATIVE APPROACH PAD FOR CONCRETE WASHOUT SYSTEMS.3'3'PLAN 1. ACTUAL LAYOUT DETERMINED IN FIELD. 2. THE CONCRETE WASHOUT SIGN SHALL BE INSTALLED WITHIN 30FT. OF THE TEMP. CONCRETE WASHOUT FACILITY. SECTION CONCRETE WASHOUT TEMPORARY CONSTRUCTION INGRESS/EGRESS PAD 150' (MIN.) SWPPP INFORMATION SIGN COPY OF NOI COPY OF IDEM NOTICE OF SUFFICIENCY SWPPP INFORMATION DETAILED DESCRIPTION OF THE LOCATION OF THE SWPPP DOCUMENTATION (BINDER AND SITE MAPS) ON THE SITE. 4' (MINIMUM)4' (MINIMUM)SIGN TO BE CONSTRUCTED OF A RIGID MATERIAL, SUCH AS PLYWOOD OR OUTDOOR SIGN BOARD. SIGN MUST BE CONSTRUCTED IN A MANNER TO PROTECT DOCUMENTS FROM DAMAGE DUE TO WEATHER (WIND, SUN, MOISTURE, ETC.). "SWPPP INFORMATION" MUST BE DISPLAYED PROMINENTLY ACROSS THE TOP OF THE SIGN, AS SHOWN IN THE DETAIL.3" MIN.3" MIN.COPY OF DRAINAGE APPROVAL LETTER COPY OF CONSTRUCTION SITE NOTICE AS APPLICABLE COPY OF CONSTRUCTION SITE NOTICE AS APPLICABLE COPY OF CONSTRUCTION SITE NOTICE AS APPLICABLE (NO SCALE) SEDIMENTATION/SILT FENCE MAXIMUM LOAD SLOPE AND DISTANCE FOR WHICH A SILT FENCE IS APPLICABLE INSTALLATION PREFABRICATED SILT FENCE 1. LAY OUT THE LOCATION OF THE FENCE SO THAT IT IS PARALLEL TO THE CONTOUR OF THE SLOPE AND AT LEAST 10 FEET BEYOND THE TOE OF THE SLOPE TO PROVIDE A SEDIMENT STORAGE AREA. TURN THE ENDS OF THE FENCE UP SLOPE SUCH THAT THE POINT OF CONTACT BETWEEN THE GROUND AND THE BOTTOM OF THE FENCE END TERMINATES AT A HIGHER ELEVATION THAN THE TOP OF THE FENCE AT ITS LOWEST POINT. 2. EXCAVATE AN EIGHT-INCH DEEP BY FOUR-INCH WIDE TRENCH ALONG THE ENTIRE LENGTH OF THE FENCE LINE. INSTALLATION BY PLOWING IS ALSO ACCEPTABLE. 3. INSTALL THE SILT FENCE WITH THE FILTER FABRIC LOCATED ON THE UP-SLOPE SIDE OF THE EXCAVATED TRENCH AND THE SUPPORT POSTS ON THE DOWN-SLOPE SIDE OF THE TRENCH. 4. DRIVE THE SUPPORT POSTS AT LEAST 18 INCHES INTO THE GROUND, TIGHTLY STRETCHING THE FABRIC BETWEEN THE POSTS AS EACH IS DRIVEN INTO THE SOIL. MINIMUM OF 12 INCHES OF THE FILTER FABRIC SHOULD EXTEND INTO THE TRENCH. 5. LAY THE LOWER FOUR INCHES OF FILTER FABRIC ON THE BOTTOM OF THE TRENCH AND EXTEND IT TOWARD THE UP-SLOPE SIDE OF THE TRENCH. 6. BACKFILL THE TRENCH WITH SOIL MATERIAL AND COMPACT IT IN PLACE. NOTE: IF THE SILT FENCE IS BEING CONSTRUCTED ON-SITE, ATTACH THE FILTER FABRIC TO THE SUPPORT POSTS AND ATTACH WOODEN LATHE TO SECURE THE FABRIC TO THE POSTS. ALLOW FOR AT LEAST 12 INCHES OF FABRIC BELOW GROUND LEVEL. COMPLETE THE SILT FENCE INSTALLATION, FOLLOWING STEPS 1 THROUGH 6 ABOVE. MAINTENANCE _ INSPECT WITHIN 24 HOURS OF A RAIN EVENT AND AT LEAST ONCE EVERY SEVEN CALENDAR DAYS. _ IF FENCE FABRIC TEARS, STARTS TO DECOMPOSE, OR IN ANY WAY BECOMES INEFFECTIVE, REPLACE THE AFFECTED PORTION IMMEDIATELY. NOTE: ALL REPAIRS SHOULD MEET SPECIFICATIONS AS OUTLINED WITHIN THIS MEASURE. _ REMOVE DEPOSITED SEDIMENT WHEN IT IS CAUSING THE FILTER FABRIC TO BULGE OR WHEN IT REACHES ONE-HALF THE HEIGHT OF THE FENCE AT ITS LOWEST POINT. WHEN CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE THE FENCE AND SEDIMENT DEPOSITS, GRADE THE SITE TO BLEND WITH THE SURROUNDING AREA, AND STABILIZE. REFERENCE IN CHAPTER 7 PAGES 215-221 IN THE INDIANA STORM WATER QUALITY MANUAL 2-WOOD POST/STAKES WRAPPED WITH SILT FENCE AND ROTATED AT LEAST ONE FULL TURN TO SECURE SILT FENCE END IN PLACE SILT FENCE SILT FENCE POST TO JOIN TO ENDS OF TWO FENCES. EMBEDDED SILT FENCE MATERIAL MIN. 8" INTO GROUND W/ 4" LAID ALONG BOTTOM OF TRENCH. SOIL SLICING IN ACCORDANCE WITH ASTM D 6462 8.2.2 IS ALSO ACCEPTABLE.18" (MIN.)GEOTEXTILE FABRIC LAID ON DOWN SLOPE SIDE AND BOTTOM OF TRENCH 8"X4" TRENCH TO BE BACKFILLED AND COMPACTED WOVEN FILTER FABRIC SILT FENCE MATERIAL COVER POST 2"X2" WOOD OR 1.33 LBS/FOOT STEEL 6' MAX. SPACING EMBEDDED SILT FENCE MATERIAL MIN. 8" INTO GROUND W/ 4" LAID ALONG BOTTOM OF TRENCH. SOIL SLICING IN ACCORDANCE WITH ASTM D 6462 8.2.2 IS ALSO ACCEPTABLE.18" (MIN.)GEOTEXTILE FABRIC LAID ON DOWN SLOPE SIDE AND BOTTOM OF TRENCH POST 2"X2" WOOD OR 1.33 LBS/FOOT STEEL 8' MAX. SPACING WIRE FENCE 14 GUAGE (MIN)-6" MESH REQ'D. IN SWALES OR AREAS OF CONCENTRATED FLOW NONWOVEN FILTER FABRIC - SECURE TO POSTS WITH 2" LATH 2-WOOD POST/STAKES WRAPPED WITH SILT FENCE AND ROTATED AT LEAST TWO FULL TURNS TO PROVIDE A SECURE CONNECTION 8"6"6"8"6"6"8"X4" TRENCH TO BE BACKFILLED AND COMPACTED POSTS: STEEL T OR U TYPE, OR 2"X2" HARD WOOD POST FENCE: WOVEN WIRE, 14-1/2 GA., 6" MAX. MESH OPENING FABRIC: IN ACCORDANCE WITH ASTM D 6461 LATEST EDITION. LOAD SLOPE LESS THAN 2% 2 TO 5% 5 TO 10% 10 TO 20% MORE THAN 20% MAX. DISTANCE ABOVE FENCE 100 FT. 75 FT. 50 FT. 25 FT. 15 FT. WITHOUT WIRE SUPPORT WITH WIRE SUPPORT (NO SCALE) FLOW FINISH GRADE UNDISTURBED GROUND FLOW FINISH GRADE UNDISTURBED GROUND REPLACEABLE SEDIMENT BAGS WITH GEOTEXTILE FILTER FABRIC STAINLESS STEEL CLAMPING BAND STANDARD 2" OVERFLOW AREA 11 GAUGE STEEL SUSPENSION SYSTEM LIFT HANDLESLIFT HANDLES INSTALLATION: 1. 2. REMOVE GRATE DROP FLEXSTORM INLET FILTER ONTO LOAD BEARING LIP OF CASTING OR CONCRETE STRUCTURE 3. REPLACE GRATE SHEET 1 OF 1 DRAWN CHECKED QA MFG APPROVED DWG NOSIZE SCALE REV ALL PRODUCTS MANUFACTURED BY INLET & PIPE PROTECTION, INC DISTRIBUTED BY ADS WWW.INLETFILTERS.COM (866) 287-8655 PH (630) 355-3477 FX INFO@INLETFILTERS.COM TABLE 1. TEMPORARY SEEDING SPECIFICATIONS SEED SPECIES 1 RATE PER ACRE PLANTING DEPTH OPTIMUM DATES2 _ I TEMPORARY SEED TABLE 1. TEMPORARY SEEDING SPECIFICATIONS _ _ _ _ _ _ _ _ _ SEED MIXTURES RATE PER ACRE PURE LIVE SEED OPTIMUM SOIL PH STEEP BANKS AND CUTS, LOW-MAINTENANCE AREAS (NOT MOWED) LAWNS AND HIGH-MAINTENANCE AREAS CHANNELS AND AREAS OF CONCENTRATED FLOW PERMANENT SEED OPEN LOW-MAINTENANCE AREAS (REMAINING IDLE MORE THAN SIX MONTHS) SEED MIXTURES RATE PER ACRE PURE LIVE SEED OPTIMUM SOIL PH SEED MIXTURES RATE PER ACRE PURE LIVE SEED OPTIMUM SOIL PH SEED MIXTURES RATE PER ACRE PURE LIVE SEED OPTIMUM SOIL PH SEASONAL SOIL PROTECTION CHART PERMANENT SEEDING SODDING MULCHING METHOD STABILIZATION SOIL SEEDING DORMANT SEEDING TEMPORARY A = KENTUCKY BLUEGRASS* 40 LBS/ACRE; CREEPING RED FESCUE 40 LBS/ACRE; PLUS 2 TONS STRAW MULCH/ACRE, OR ADD ANNUAL RYEGRASS 20 LBS/ACRE. B = KENTUCKY BLUEGRASS* 60 LBS/ACRE; CREEPING RED FESCUE 60 LBS/ACRE; PLUS 2 TONS STRAW MULCH/ACRE, OR ADD ANNUAL RYEGRASS 30 LBS/ACRE. C = SPRING OATS 3 BUSHEL/ACRE. D = WHEAT OR RYE 2 BUSHEL/ACRE. E = ANNUAL RYEGRASS 40 LBS/ACRE. F = SOD (BLEND 3 IMPROVED VARIETIES). G = STRAW MULCH 2 TONS/ACRE. */I/* IRRIGATION NEEDED DURING JUNE, JULY, AND/OR SEPTEMBER. ** IRRIGATION NEEDED FOR 2 TO 3 WEEKS AFTER APPLYING SOD. *KENTUCKY BLUEGRASS BLEND OF 3 IMPROVED VARIETIES. IPP C203SWPPP SPECIFICATIONS & DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMELC202 SWPPP SPECS11/07/22 10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C202 SWPPP Specs & Details.dwgLAYOUT: C204DATE/TIME: August 31, 2022 - 10:48amPLOTTED BY: hansenbfhgENGINE E RS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, Indiana2"-5" (5 CM-12.5CM) 12" (30 CM)6" (15 CM)6" (15 CM) 3" (7.5 CM) SLOPE INSTALLATION SPECIFICATIONS : SITE PREPARATION MATERIALS INSTALLATION SITE PREPARATION SOD BED PREPARATION LAYING THE SOD SLOPE APPLICATION CHANNEL APPLICATION MAINTENANCE CROSS SECTION PERSPECTIVE VIEW C202 SWPPP SPECSC204SWPPP SPECIFICATIONS & DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMELNATIVE AQUATIC SHORELINE SEED MIX BOTANICAL NAME COMMON NAME OZ./ACRE PERMANENT GRASSES/SEDGES/RUSHES: BOLBOSCHOENUS FLUVIATILIS RIVER BULRUSH 1.00 CAREX CRISTATELLA CRESTED OVAL SEDGE 0.50 CAREX LURIDA BOTTLEBRUSH SEDGE 3.00 CAREX VULPINOIDEA BROWN FOX SEDGE 2.00 ELYMUS VIRGINICUS VIRGINIA WILD RYE 24.00 GLYCERIA STRIATA FOWL MANNA GRASS 1.00 JUNCUS EFFUSUS COMMON RUSH 1.00 LEERSIA ORYZOIDES RICE CUT GRASS 1.00 PANICUM VIRGATUM SWITCH GRASS 2.00 SCHOENOPLECTUS TABERNAEMONTANI GREAT BULRUSH 3.00 SCIRPUS ATROVIRENS DARK GREEN RUSH 2.00 SCIRPUS CYPERINUS WOOL GRASS 1.00 TOTAL 41.50 TEMPORARY COVER: AVENA SATIVA COMMON OAT 360.00 LOLIUM MULTIFLORUM ANNUAL RYE 100.00 TOTAL 460.00 FORBES & SHRUBS: ALISMA SUCORDATUM COMMON WATER PLANTAIN 2.50 ASCLEPIAS INCARNATA SWAMP MILKWEED 2.00 BIDENS SPP.BIDENS SPECIES 2.00 EUPATORIUM PERFOLIATUM COMMON BONESET 1.00 HELENIUM AUTUMNALE SNEEZEWEED 2.00 IRIS VIRGINICA V. SHREVEI BLUE FLAG 4.00 LYCOPUS AMERICANUS COMMON WATER HOREHOUND 0.50 MIMULUS RINGENS MONKEY FLOWER 1.00 PENTHORUM SEDOIDES DITCH STONECROP 0.50 PERSICARIA SPP.PINKWEED SPECIES 2.00 RUDBECKIA SUBTOMENTOSA SWEET BLACK-EYED SUSAN 1.00 RUDBECKIA TRILOBA BROWN-EYED SUSAN 1.50 SAGITTARIA LATIFOLIA COMMON ARROWHEAD 1.00 SENNA HEBECARPA WILD SENNA 2.00 SYMPHYOTRICHUM LANCEOLATUM PANICLED ASTER 0.50 SYMPHYOTRICHUM NOVAE-ANGLIAE NEW ENGLAND ASTER 0.50 THALICTRUM DASYCARPUM PURPLE MEADOW RUE 2.00 TOTAL 26.00 11/07/22 LEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = FLOW DIRECTION = EXISTING CONTOURS = PROPOSED ELEVATION = PROPOSED CONTOURS = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = PAD ELEV (SEE EACH PAD FOR PAD SIZE) = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE D = LIMITS OF DISTURBANCE*= BUBBLER = BIKE PARKINGDDDDD D DDDDDDDDDDDDDDDDDDDDDD D D D D D D D D DDD D D D DDDDDDDD DDDDDD D DDDDDDDDDDDDDDDDDDDDDDDDWWWW W W W EG G G G G G G G G G G G G G G G G GG W OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU 146TH STREET VAR. WIDTH ROW W W W W W W W W W W W W W W W WPARKHURS LOT 64 OWNER: DENISE M. BRAGGLOT 13OWNER:CHRISTOPHER S. &SEEMA M. MERNITZLOT 10OWNER: MICHELE L. &FERNANDO MORALESBLOCK COWNER: WESTCHASE HOA, INC.BLOCK B OWNER: WESTCHASE HOA, INC.WESTCHASE SUBDIVISIONINSTRUMENT NO. 200000051957LOT 12OWNER: JEFFREY K. &EVA M. TOMLINSONLOT 11OWNER: CRAIG B. & KELLY J.ROBBINSLOT 9 OWNER: JEFFREY P. & HEATHER L. KECK LOT 8 OWNER: DAVID P. & KRISTAN E. LINTON LOT 7 OWNER: HAI FENG & ZHI XU LOT 65 OWNER: NEIL A. & LYNN K. ZLATNISKI LOT 66 OWNER: GANI, HABIBULLA & YASMIN HAJIRA MOHAMED LOT 67 OWNER: ROBERT A. & LISA M. KNAPP LOT 68 OWNER: RAYMOND E. & ANDREA MULLER LOT 146 OWNER: MICHELLE R. & CHAD E. MOORE LOT 151 OWNER: CHRISTIAN E. & SARA J. GRETHLEIN LOT 165 OWNER: TODD J. DARLAND & TRACY R. WEGMAN-DARLAND BLOCK DOWNER: WESTCHASE HOA, INC.BIRDSONG LANE 146TH STREET 26 1 7 8 9 11 12 10 13 28 27 24 25 23 16 17 18 14 3 2 5 4 29 30 31 32 33 34 1920 22 6 21 15 W W W W WWWWWWWWWWWWWWW WWWWWW W W W WWWWWWWWWWWWW W W W W WBEDFORDFALLS DR.GOWER DRIVE BIRDSONG LANEMITCHEL LANEBEDFORDFALLS DRIVE* ** * * * * * ** * * * * * * * * * * C.A. AC.A. A C.A. B C.A. A C.A. C GUARDRAIL FMFMFMFMFMFMFM* * FMFMFMFMFMFMFMA D D D D DDDDDDDDDDDDDDDDDW W W W W W G G G G G G WOHU OHU OHU OHU LOT 152 OWNER: RONALD J. & JUDITH A. HANSON WARRANTY DEED BOARD OF COMMISSIONERS OF HAMILTON COUNTY INSTRUMENT NO. 2013066530 BFE 886.8 BFE 886.9 BFE 886.7 BFE 886.5 BFE 886.3 BFE 886.2ZONE AE ZONE AE ZONE AE ZONE AE POND 1 C.A. C A B B D D D D D D D DDDD DDDDD LOT 66 OWNER: GANI, HABIBULLA & YASMIN HAJIRA MOHAMED LOT 67 OWNER: ROBERT A. & LISA M. KNAPP LOT 68 OWNER: RAY MULLER 880 885 890 880 885 890 FINISHED GRADE EXISTING GRADE PROFILE LEGEND BFE 886.4 EMERGENCY OVERFLOW WEIR INVERT = 887.50 SECTION A-A Know what'sbelow. before you dig.Call R W S N E GENERAL GRADING NOTES 1. REFER TO THE INDIANA DEPARTMENT OF TRANSPORTATION (INDOT) STANDARD SPECIFICATIONS, LATEST EDITION, FOR BASIC MATERIALS AND CONSTRUCTION METHODS. 2. FILL MATERIAL SHALL CONSIST OF SOIL OBTAINED FROM CUT AREAS, BORROW PITS OR OTHER APPROVED SOURCES. SOIL SHALL BE FREE FROM ORGANIC MATTER, LARGE ROCKS AND OTHER DELETERIOUS SUBSTANCES. THE FILL MATERIAL SHALL BE PLACED IN LAYERS NOT TO EXCEED SIX INCHES FOLLOWING COMPACTION, PROPER MOISTURE CONTENT OF FILL MATERIAL WILL BE SUCH TO ACHIEVE SPECIFIED COMPACTION DENSITY. ALL FILL BENEATH PAVED AREAS, FLOOR SLABS AND FUTURE BUILDINGS SHALL BE COMPACTED TO AT LEAST 95% OF THE MAXIMUM DRY DENSITY PER ASTM D-1557. FIELD COMPACTION TESTS SHALL BE RUN ON EACH LIFT, IN FILL SECTIONS. THE REQUIRED COMPACTION ON EACH LIFT SHALL BE IN ACCORDANCE WITH INDOT SECTION 211. 3. MAXIMUM LAWN SLOPE IS 3:1. 4. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE MAINS, CONDUITS, SERVICE LINES AND OTHER FACILITIES IN THE AFFECTED CONSTRUCTION AREA. EXISTING UTILITY STRUCTURES ARE SHOWN HERE IN ACCORDANCE WITH AVAILABLE INFORMATION. THE LOCATION AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE UTILITY COMPANY) IS THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 5. ALL SPOT ELEVATIONS ARE TO FINISHED GRADE. 6. COMPACTED "B" BORROW BACK FILL REQ'D. OVER ALL UTILITIES IN PAVED AREAS. 7. ALL GRADES AT BOUNDARY SHALL MEET EXISTING. 8. ANY PART OF SANITARY / STORM SEWER AND WATER MAIN TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL. 9. ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A. STANDARDS FOR WORKER SAFETY. 10. THE CONTRACTOR SHALL CONFIRM ALL EARTHWORK QUANTITIES PRIOR TO THE START OF CONSTRUCTION. IF AN EXCESS OR SHORTAGE OF SOIL IS ENCOUNTERED, THE CONTRACTOR SHALL CONFIRM WITH THE OWNER AND ENGINEER THE REQUIREMENTS FOR STOCKPILING, REMOVING OR IMPORTING OF SOIL. 11. PROVIDE POSITIVE DRAINAGE WITHOUT PONDING IN ALL AREAS. CONTRACTOR TO TEST FOR AND CORRECT ANY PONDING CONDITIONS. 12. CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWER FACILITIES, WATER MAIN, AND STORM SEWERS IS 18" OR LESS. 13. GRANULAR BACKFILL TO BE USED FOR ALL UTILITY AND SEWER - STREET CROSSINGS. 14. ALL PROPOSED CURB TO BE ROLL CURB UNLESS NOTED OTHERWISE. 15. ALL 6" SSD TO BE DOUBLE WALL, GASKETED SMOOTH BORE, DRAIN TILE. 16. THE MINIMUM FINISHED FLOOR ELEVATION (MFFE) OF EACH HOUSE SHALL BE A MINIMUM OF 1' ABOVE THE HIGHEST ADJACENT STREET ELEVATION. 17. PROPOSED STORM SEWERS TO BE OWNED BY HAMILTON COUNTY.C300 Development PlanC300DEVELOPMENT PLANW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C300 Development Plan.dwgLAYOUT: C300DATE/TIME: August 31, 2022 - 10:49amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) SEE CONTINUATION TO RIGHT SEE CONTINUATION TO LEFT NOTE: CONTRACTOR TO MAINTAIN POSITIVE DRAINAGE PATTERNS FROM OFFSITE LAND WEST OF SITE. * NOTES: THE DETENTION FOR THE SITE IS PROVIDED BY ONE WET POND. THE POND DISCHARGES INTO WILLIAMS CREEK. THE 36" HINSHAW-HENLEY LEGAL DRAIN PIPE IS ROUTED THROUGH THE PROPOSED POND. DRAINAGE SUMMARY PEAK DISCHARGE (CFS) INTO WILLIAMS CREEK RETURN PERIOD 10 YR. 100 YR. 1.08 1.00 ALLOWABLE DESIGN OVERALL SITE ACREAGE POND WATERSHED ACREAGE DETENTION VOLUME REQUIRED DETENTION VOLUME PROVIDED 16.87 ACRES 15.70 ACRES 4.296 AC-FT 4.311 AC-FT 3.25 3.18 9.95 PRE 28.42 SECTION B-B 11/07/22 LEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINEDDDDD D DDDDDDDDDDDDDDDDDDDDDD D D D D D D D D DDD D D D DDDDDDDD DDDDDD DDDDDDDDDDDDDDDDDDDDDW W W W W EG G G G G G G G G G G G G G G GGOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU 146TH STREET VAR. WIDTH ROW W W W W W W W W W W W W W W W W W LOT 64 OWNER: DENISE M. BRAGGLOT 13OWNER:CHRISTOPHER S. &SEEMA M. MERNITZLOT 10OWNER: MICHELE L. &FERNANDO MORALESBLOCK COWNER: WESTCHASE HOA, INC.BLOCK B OWNER: WESTCHASE HOA, INC.WESTCHASE SUBDIVISIONINSTRUMENT NO. 200000051957LOT 12OWNER: JEFFREY K. &EVA M. TOMLINSONLOT 11OWNER: CRAIG B. & KELLY J.ROBBINSLOT 9 OWNER: JEFFREY P. & HEATHER L. KECK LOT 8 OWNER: DAVID P. & KRISTAN E. LINTON LOT 7 OWNER: HAI FENG & ZHI XU LOT 65 OWNER: NEIL A. & LYNN K. ZLATNISKI LOT 66 OWNER: GANI, HABIBULLA & YASMIN HAJIRA MOHAMED LOT 67 OWNER: ROBERT A. & LISA M. KNAPP LOT 68 OWNER: RAYMOND E. & ANDREA MULLER LOT OWNER: MICHEL E. MOORE OWNER: OWNER TRAC BLOCK DOWNER: WESTCHASE HOA, INC.BIRDSONG LANE 146TH STREET 26 1 7 8 9 11 12 10 13 28 27 24 25 23 16 17 18 14 3 2 5 4 29 30 31 32 33 34 1920 22 6 21 15 W W W WWWWWWWWWWWWWWW WWWWWW W W W W W WWWWWWWWWWW W W W W WBEDFORDFALLS DR . GOWER DRIVE BIRDSONG LANEMITCHEL LANEBEDFORDFALLS DRIVE* ** * * * * * * * * * * * * * ** * * C.A. A C.A. A C.A. B C.A. A C.A. C FMFMFMFMFMFMFM* * FMFMFMFMFMFMFMD D D D D D DD DDDDDDDDDDDDDDDDDW W W W W W W W G G G G G G G G WOHU OHU OHU OHU OHU OHU LOT 165 DARLAND & LOT 152 OWNER: RONALD J. & JUDITH A. HANSON WARRANTY DEED BOARD OF COMMISSIONERS OF HAMILTON COUNTY INSTRUMENT NO. 2013066530 BFE 886.9 BFE 886.5 BFE 886.3 BFE 886.2ZONE AE ZONE AE ZONE AE ZONE AE POND 1 C.A. C GUARDRAIL Know what'sbelow. before you dig.Call R W S N E GENERAL GRADING NOTES 1. REFER TO THE INDIANA DEPARTMENT OF TRANSPORTATION (INDOT) STANDARD SPECIFICATIONS, LATEST EDITION, FOR BASIC MATERIALS AND CONSTRUCTION METHODS. 2. FILL MATERIAL SHALL CONSIST OF SOIL OBTAINED FROM CUT AREAS, BORROW PITS OR OTHER APPROVED SOURCES. SOIL SHALL BE FREE FROM ORGANIC MATTER, LARGE ROCKS AND OTHER DELETERIOUS SUBSTANCES. THE FILL MATERIAL SHALL BE PLACED IN LAYERS NOT TO EXCEED SIX INCHES FOLLOWING COMPACTION, PROPER MOISTURE CONTENT OF FILL MATERIAL WILL BE SUCH TO ACHIEVE SPECIFIED COMPACTION DENSITY. ALL FILL BENEATH PAVED AREAS, FLOOR SLABS AND FUTURE BUILDINGS SHALL BE COMPACTED TO AT LEAST 95% OF THE MAXIMUM DRY DENSITY PER ASTM D-1557. FIELD COMPACTION TESTS SHALL BE RUN ON EACH LIFT, IN FILL SECTIONS. THE REQUIRED COMPACTION ON EACH LIFT SHALL BE IN ACCORDANCE WITH INDOT SECTION 211. 3. MAXIMUM LAWN SLOPE IS 3:1. 4. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE MAINS, CONDUITS, SERVICE LINES AND OTHER FACILITIES IN THE AFFECTED CONSTRUCTION AREA. EXISTING UTILITY STRUCTURES ARE SHOWN HERE IN ACCORDANCE WITH AVAILABLE INFORMATION. THE LOCATION AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE UTILITY COMPANY) IS THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 5. ALL SPOT ELEVATIONS ARE TO FINISHED GRADE. 6. COMPACTED "B" BORROW BACK FILL REQ'D. OVER ALL UTILITIES IN PAVED AREAS. 7. ALL GRADES AT BOUNDARY SHALL MEET EXISTING. 8. ANY PART OF SANITARY / STORM SEWER AND WATER MAIN TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL. 9. ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A. STANDARDS FOR WORKER SAFETY. 10. THE CONTRACTOR SHALL CONFIRM ALL EARTHWORK QUANTITIES PRIOR TO THE START OF CONSTRUCTION. IF AN EXCESS OR SHORTAGE OF SOIL IS ENCOUNTERED, THE CONTRACTOR SHALL CONFIRM WITH THE OWNER AND ENGINEER THE REQUIREMENTS FOR STOCKPILING, REMOVING OR IMPORTING OF SOIL. 11. PROVIDE POSITIVE DRAINAGE WITHOUT PONDING IN ALL AREAS. CONTRACTOR TO TEST FOR AND CORRECT ANY PONDING CONDITIONS. 12. CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWER FACILITIES, WATER MAIN, AND STORM SEWERS IS 18" OR LESS. 13. GRANULAR BACKFILL TO BE USED FOR ALL UTILITY AND SEWER - STREET CROSSINGS. 14. ALL PROPOSED CURB TO BE ROLL CURB UNLESS NOTED OTHERWISE. 15. ALL 6" SSD TO BE DOUBLE WALL, GASKETED SMOOTH BORE, DRAIN TILE. EMERGENCY OVERFLOW= LEGEND: =PONDING LIMITS FOR A CLOGGED CONDITION =SPILL OVER ELEVATION FOR A CLOGGED CONDITION NOTE: SEE DRAINAGE REPORT FOR INDIVIDUAL WEIR WIDTHS C301 EFRPC301EMERGENCY FLOOD ROUTE PLANW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C301 EFRP.dwgLAYOUT: C301DATE/TIME: August 31, 2022 - 10:50amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) NOTES: THE DETENTION FOR THE SITE IS PROVIDED BY ONE WET POND. THE POND DISCHARGES INTO WILLIAMS CREEK. THE 36" HINSHAW-HENLEY LEGAL DRAIN PIPE IS ROUTED THROUGH THE PROPOSED POND. DRAINAGE SUMMARY PEAK DISCHARGE (CFS) INTO WILLIAMS CREEK RETURN PERIOD 10 YR. 100 YR. 1.08 1.00 ALLOWABLE DESIGN OVERALL SITE ACREAGE POND WATERSHED ACREAGE DETENTION VOLUME REQUIRED DETENTION VOLUME PROVIDED 16.87 ACRES 15.70 ACRES 4.296 AC-FT 4.311 AC-FT 3.25 3.18 9.95 PRE 28.42 11/07/22 GGGGGGGGGOHUOHUOHUOHUOHUOHUOHUWWWWWWWWNC.IATHERE.146THSTREET261789102827242523325422621W W W W W W W W W W W W W W W W W W W WWWWW********C.A. AC.A. AFMFM**FMFMBE DFOR D FA LLS D R. BEDFORD FALLS DRIVEGOWER DRIVE875 880 885 890 895 900 905 910 915 17+50LEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE 875 880 885 890 895 900 905 910 915 0+500+751+001+251+501+752+002+252+502+753+003+253+503+754+004+254+504+755+005+255+505+756+006+256+506+757+007+257+507+758+008+258+508+759+009+259+509+7510+0010+2510+5010+7511+0011+25FINISHED GRADE EXISTING GRADE PROFILE LEGEND PROP. GRADE ELEV. EXIST. GRADE ELEV. (LOCAL SECTION) Bedford Falls Drive & Mitchel Lane Know what'sbelow. before you dig.Call R N W E S C400 Street PnPC400STREET PLAN & PROFILEW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C400 Street PnP.dwgLAYOUT: C400DATE/TIME: August 31, 2022 - 10:50amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaNOTES 1. STANDARD SPECIFICATIONS BY THE LOCAL HIGHWAY DEPARTMENT, LATEST EDITION, SHALL APPLY TO THIS PROJECT FOR ALL STREET IMPROVEMENTS. 2. ALL STREETS TO BE 32' IN WIDTH (MEASURED FROM B-B OF CURB) UNLESS OTHERWISE NOTED. 3. ALL RIGHTS-OF-WAY TO BE 56' IN WIDTH UNLESS OTHERWISE NOTED. 4. ALL CURB RADII AT INTERSECTIONS ARE 25' TO BACK OF CURB UNLESS OTHERWISE NOTED. 5. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 6. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER SAFETY. 7. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 8. SEE SECONDARY PLAT FOR STREET CENTERLINE GEOMETRY, EASEMENT LOCATIONS AND DESIGNATIONS. 9. ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY.PROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) 11/07/22 LOT 67LOT 68OWNER: RAYMOND E. & ANDREAOWNER:OWNE2691112101328272425231617181429303132333419202115WWWWWWWWWWW W W W W W W W W W W WWWWWW************C.A. AC.A.BC.A. CFM FM FM FMFMFMFMFM FM FM FMFMFMFMGOWER DRIVEBIRDSONGLANEMITCHEL LANE 875 880 885 890 895 900 905 910 6+757+007+257+507+758+008+258+508+759+009+259+509+7510+0010+2510+5010+7511+0011+2511+5011+7512+0012+2512+5012+7513+0013+2513+5013+7514+0014+2514+5014+7515+0015+2515+5015+7516+0016+2516+5016+7517+0017+2517+50FINISHED GRADE EXISTING GRADE PROFILE LEGEND PROP. GRADE ELEV. EXIST. GRADE ELEV. 875 880 885 890 895 900 905 910 0+50(LOCAL SECTION) Bedford Falls Drive & Mitchel Lane LEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE Know what'sbelow. before you dig.Call R S E W N C400 Street PnPC401STREET PLAN & PROFILEW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C400 Street PnP.dwgLAYOUT: C401DATE/TIME: August 31, 2022 - 10:51amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaNOTES 1. STANDARD SPECIFICATIONS BY THE LOCAL HIGHWAY DEPARTMENT, LATEST EDITION, SHALL APPLY TO THIS PROJECT FOR ALL STREET IMPROVEMENTS. 2. ALL STREETS TO BE 32' IN WIDTH (MEASURED FROM B-B OF CURB) UNLESS OTHERWISE NOTED. 3. ALL RIGHTS-OF-WAY TO BE 56' IN WIDTH UNLESS OTHERWISE NOTED. 4. ALL CURB RADII AT INTERSECTIONS ARE 25' TO BACK OF CURB UNLESS OTHERWISE NOTED. 5. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 6. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER SAFETY. 7. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 8. SEE SECONDARY PLAT FOR STREET CENTERLINE GEOMETRY, EASEMENT LOCATIONS AND DESIGNATIONS. 9. ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY.PROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) 11/07/22 1 23 17 1834 1920 22 21 WWWWWWWWW W W W W WBEDFORDFALLS DR.GOWER DRIVE* ** * * * * * * * C.A. A C.A. C FMFMFMFMFMFMFMFMFMFMFMFMFMFM(LOCAL SECTION) Gower Drive 875 880 885 890 895 900 905 910 875 880 885 890 895 900 905 910 0+500+751+001+251+501+752+002+252+502+753+003+253+503+754+004+254+50FINISHED GRADE EXISTING GRADE PROFILE LEGEND PROP. GRADE ELEV. EXIST. GRADE ELEV. (LOCAL SECTION) Birdsong Lane 875 880 885 890 895 900 905 910 875 880 885 890 895 900 905 910 0+500+751+001+251+501+752+002+252+502+753+003+253+50FINISHED GRADE EXISTING GRADE PROFILE LEGEND PROP. GRADE ELEV. EXIST. GRADE ELEV. LOT 151 OWNER: CHRISTIAN E. & SARA J. GRETHLEIN LOT 165 OWNER: TODD J. DARLAND & TRACY R. WEGMAN-DARLAND BIRDSONG LANE 16 1429 30 31 32 15 W W W W W WWWWWWWBIRDSONG LANEMITCHEL LANE* * * * ** * * LEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE Know what'sbelow. before you dig.Call R W S N E C400 Street PnPC402STREET PLAN & PROFILEW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C400 Street PnP.dwgLAYOUT: C402DATE/TIME: August 31, 2022 - 10:51amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaNOTES 1. STANDARD SPECIFICATIONS BY THE LOCAL HIGHWAY DEPARTMENT, LATEST EDITION, SHALL APPLY TO THIS PROJECT FOR ALL STREET IMPROVEMENTS. 2. ALL STREETS TO BE 32' IN WIDTH (MEASURED FROM B-B OF CURB) UNLESS OTHERWISE NOTED. 3. ALL RIGHTS-OF-WAY TO BE 56' IN WIDTH UNLESS OTHERWISE NOTED. 4. ALL CURB RADII AT INTERSECTIONS ARE 25' TO BACK OF CURB UNLESS OTHERWISE NOTED. 5. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 6. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER SAFETY. 7. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 8. SEE SECONDARY PLAT FOR STREET CENTERLINE GEOMETRY, EASEMENT LOCATIONS AND DESIGNATIONS. 9. ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY.PROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) 11/07/22 18 34 1920 WWWWWW W W W W W W W W * * * * C.A. C FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMGOWER DRIVE MITCHEL LANELOT 151 OWNER: CHRISTIAN GRETHLEIN 1429 30 31 15 W W W W W W W W W W W W WWWWWWWWWWW* * ** ** * * BIRDSONG LANE MITCHEL LANE1 23 22 21 WWWWWWWWWWWWW W W W * * * * * * C.A. A FMFMFMFMBEDFORDFALLS DR.GOWER DRIVE LEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE Know what'sbelow. before you dig.Call R W S N E INTERSECTION DETAIL MITCHEL LANE & BIRDSONG LANE INTERSECTION DETAIL BEDFORD FALLS DRIVE & GOWER DRIVE INTERSECTION DETAIL GOWER DRIVE & MITCHEL LANE NOTES 1. STANDARD SPECIFICATIONS BY THE LOCAL HIGHWAY DEPARTMENT, LATEST EDITION, SHALL APPLY TO THIS PROJECT FOR ALL STREET IMPROVEMENTS. 2. ALL STREETS TO BE 32' IN WIDTH (MEASURED FROM B-B OF CURB) UNLESS OTHERWISE NOTED. 3. ALL RIGHTS-OF-WAY TO BE 56' IN WIDTH UNLESS OTHERWISE NOTED. 4. ALL CURB RADII AT INTERSECTIONS ARE 25' TO BACK OF CURB UNLESS OTHERWISE NOTED. 5. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 6. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER SAFETY. 7. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 8. SEE SECONDARY PLAT FOR STREET CENTERLINE GEOMETRY, EASEMENT LOCATIONS AND DESIGNATIONS.C403 Intersection DetailC403INTERSECTION DETAILW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C403 Intersection Detail.dwgLAYOUT: C403DATE/TIME: August 31, 2022 - 10:52amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) 11/07/22 G G G G G G G G G G G G G G G G G G G GGGGGOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU W W W W W W W W W W W W W W W W W W W W W W W W W W W WPARKHURSTDRIVE LOT 13OWNER:CHRISTOPHER S. &SEEMA M. MERNITZBLOCK COWNER: WESTCHASE HOA, INC.BLOCK B OWNER: WESTCHASE HOA, INC. 146TH STREET 22 21WWWWWWWWWWW W* ** * LEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE Know what'sbelow. before you dig.Call R ENTRANCE PLAN 146TH STREET & BEDFORD FALLS DRIVE C404 Entrance PlanC404ENTRANCE PLANW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C404 Entrance Plan.dwgLAYOUT: C404DATE/TIME: August 31, 2022 - 10:52amPLOTTED BY: hansenbfhgEN G I N EER S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaW S N E PROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) NOTES 1. ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. 3. SQUARE POSTS SIZED IN ACCORDANCE WITH INDOT STANDARD DRAWING E 802-SNGS-07. · UNREINFORCED ANCHOR BASE INSTALLED PER INDOT STANDARD DRAWING E 802-SNGS-09. · FOR STREET NAME SIGNS USE TYPE 11 SQUARE POST · FOR POSTS MOUNTED ON CONCRETE - SNAP-N-SAFE MODEL S200S (TYPE II POST) OR MODEL S225S (TYPE I POST) FLUSH MOUNT BRACKETS SHALL BE USED. 4. SIGN TYPE/PLACEMENT IN ACCORDANCE WITH THE CURRENT INDIANA MUTCD. ALL SIGNS, TEMPORARY TRAFFIC CONTROL SIGNS AND BARRICADES MUST COMPLY WITH THE CURRENT INDIANA MUTCD. 5. SIGN MATERIALS IN ACCORDANCE WITH INDOT STANDARD SPECIFICATIONS SEC 919. · SIGN SHEETING IN ASTM TYPE IV OR BETTER · WARNING SIGNS SHALL BE FLUORESCENT YELLOW · PEDESTRIAN SIGNS SHALL BE FLUORESCENT YELLOW-GREEN 6. PER MUTCD, STREET NAME SIGNS ON MULTI-LANE FACILITIES MUST HAVE 8" CAPITAL LETTER/NUMBERS AND 6" LOWERCASE LETTERS ON AN 18" BLADE. · STREET NAMES SIGNS SHALL HAVE WHITE BORDERS · 18" BLADES WILL BE SINGLE SIDED AND BOLTED DIRECTLY TO THE POST. ·· POST LENGTH MUST BE INCREASED BY 36" ·· DEPENDING NO BLADE LENGTH, SCRAP POST SHOULD BE BOLTED BETWEEN TWO SINGLE SIDED BLADES FOR SUPPORT. 11/07/22 W W W W W W G G G G G G G G G G G GOHU OHU OHU OHU OHU OHU OHU OHU OHU W W W W W W W W LOT 13OWNER:CHRISTOPHER S. &SEEMA M. MERNITZBLOCK CWNER: WESTCHASE HOA, INC.BLOCK B OWNER: WESTCHASE HOA, INC. WARRANTY DEED BOARD OF COMMISSIONERS OF HAMILTON COUNTYINSTRUMENT NO. 2013066530 ZONE AE ZONE AE 1920 22 21 WW* * C.A. C GUARDRAIL FMFM* * FMFMBFA146TH STREET ROAD WORK AHEAD ENDROAD WORKROAD WORK AHEAD 146TH STREET 146TH S T R E E TDITCH ROADDITCH ROADRIGHT LANE CLOSED AHEAD RIGHT LANE CLOSED AHEAD ENDROADWORKPARKHURST DR.SIDEWALK CLOSEDSIDEWALK CLOSEDLEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE W W W G G G G G GOHU OHU OHU OHUW W W LOT 13OWNER:CHRISTOPHER S. &SEEMA M. MERNITZLOT 10OWNER: MICHELE L. &FERNANDO MORALESBLOCK COWNER: WESTCHASE HOA, INC.BLOCK B OWNER:WESTCHASE HOA, INC.WESTCHASE SUBDIVISIONINSTRUMENT NO. 200000051957LOT 12OWNER: JEFFREY K. &EVA M. TOMLINSONLOT 11OWNER: CRAIG B. & KELLY J.ROBBINSLOT 165 OWNER: TODD J. DARLAND & LOT 152 OWNER: RONALD J. & JUDITH A.HANSON WARRANTY DEEDBOARD OF COMMISSIONERSOF HAMILTON COUNTYINSTRUMENT NO. 2013066530 A, INC.BFE 886.8 BFE 886.9 BFE 886.7 BFE 886.5 BFE 886.3 FE 886.2ZONE AE ZONE AE ZONE AE ZONE AE ZONE AE ZONE AE ZONE AE 1 24 23 16 17 18 2 33 34 1920 22 21 WWWW * ** * * * * * * * * * C.A. A C.A. C C.A. C GUARDRAIL FM* * FMBEDFORDFALLS DR.146TH STREET GOWER DRIVE MITCHEL LANEROAD WORKAHEAD ROAD WORK AHEAD 146TH STREET 146TH S T R E ETDITCH ROADDITCH ROADCLOSED AHEAD CLOSED AHEAD ENDROAD WORKENDROAD WORKENDROAD WORKENDROAD WORKLEFT LANE LEFT LANE BALLANTRAE CIR,WARNER TRAILTHOMAS DR.PARKHURST DR.CLOSED AHEAD CLOSED AHEAD LEFT LANE LEFT LANE ROAD WORK AHEAD ROAD WORK AHEAD Know what'sbelow. before you dig.Call R NOTES: 1. DURING THE COURSE OF CONSTRUCTION, ONE LANE REDUCTION WILL BE ALLOWED BETWEEN THE HOURS OF 9AM TO 4PM. THE LANE MUST BE REOPENED AT THE END OF EACH DAY THAT IT IS CLOSED. 2. THE BARRICADES SHALL BE MOVED TO THE EDGE OF PAVEMENT AT TIMES OF NO CONSTRUCTION TO ALLOW FOR UNOBSTRUCTED TRAFFIC FLOW THROUGH THE CONSTRUCTION AREA. 3. FENCING AND BARRICADES SHALL BE PLACED SO AS TO ENCOMPASS ANY EXPOSED TRENCH AREA AT TIMES OF NO CONSTRUCTION. 4. THE ROAD WORK AHEAD SIGN SHALL ALSO BE COVERED OR TURNED AWAY FROM THE ROADWAY AT TIMES OF NO CONSTRUCTION. 5. THE MAINTENANCE OF TRAFFIC SHALL CONFORM TO THE CURRENT STANDARD SPECIFICATIONS OF THE INDIANA DEPARTMENT OF TRANSPORTATION STANDARD DETOUR SHEETS AND THE INDIANA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS AND ALL SUBSEQUENT REVISIONS. 6. ANY DROP OFF ADJACENT TO THE TRAVEL LANE WHICH EXCEEDS 4" MUST HAVE TYPE II DRUMS WITH TYPE 'A' FLASHERS SPACED EVERY 100' 7. DURING THE COURSE OF CONSTRUCTION FOR THIS PROJECT, THE CONTRACTOR SHALL KEEP A 10' WIDE LANE OPEN AT ALL TIMES. 8. THE TRAFFIC MAINTENANCE PLAN SHALL MEET ALL REQUIREMENTS OF THE INDOT WORK ZONE SAFETY MANUAL, CURRENT ADDITION. CONTRACTOR TO FOLLOW GUIDELINES REFERENCED IN THE INDOT WORK ZONE TRAFFIC CONTROL HANDBOOK. 9. ANY LANE RESTRICTION ON 146TH STREET MUST BE APPROVED BY HAMILTON COUNTY BOARD OF COMMISSIONERS AT A REGULARLY SCHEDULED MEETING. LANE RESTRICTIONS ARE LIMITED TO WEEKDAYS BETWEEN THE HOURS OF 9AM AND 3PM. 10. A CHANGEABLE MESSAGE SIGN IS REQUIRED FOR ANY LANE RESTRICTION AND MUST BE IN PLACE NOT LESS THAN 7 DAYS IN ADVANCE OF THE RESTRICTION. THE MESSAGE MUST INFORM MOTORISTS OF THE LANE, DATE AND HOURS. ANY MESSAGE MUST BE APPROVED BY THE HAMILTON COUNTY HIGHWAY DEPARTMENT. 11. SIGN TYPE/PLACEMENT IN ACCORDANCE WITH THE CURRENT INDIANA MUTCD. ALL SIGNS, TEMPORARY TRAFFIC CONTROL SIGNS AND BARRICADES MUST COMPLY WITH THE CURRENT INDIANA MUTCD. MAINTENANCE OF TRAFFIC LEGEND: - DRUM (PER INDOT SPEC. 801.09) SPACED AS NOTED WITH TYPE C STEADY BURN LIGHTS. - ADVANCED WARNING SIGN - END OF ROAD WORK SIGN 2 2 2 2 10 1 2 W9-3R (36X36) RIGHT LANE CLOSED AHEAD W4-2R-O (36X36) LANE ENDS MERGE LEFT W20-1A (36X36) ROAD CONSTRUCTION AHEAD G20-2 (36X18) END ROAD WORK DRUM (PER INDOT SPEC 801.09) SPACED AS NOTED FLASHING CAUTION ARROW BOARD R9-9 (24X12) SIDEWALK CLOSED SIGNAGE SCHEDULE:C405 MOT PlanC405MAINTENANCE OF TRAFFIC PLANW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C405 MOT Plan.dwgLAYOUT: C405DATE/TIME: August 31, 2022 - 10:53amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaW S N E PROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) CONSTRUCTION AT ENTRANCE CONSTRUCTION IN MEDIAN W S N E 4 4 4 4 30 2 W9-3L (36X36) LEFT LANE CLOSED AHEAD W4-2L-O (36X36) LANE ENDS MERGE RIGHT W20-1A (36X36) ROAD CONSTRUCTION AHEAD G20-2 (36X18) END ROAD WORK DRUM (PER INDOT SPEC 801.09) SPACED AS NOTED FLASHING CAUTION ARROW BOARD SIGNAGE SCHEDULE: 11/07/22 LEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN TOC R. = TOP OF CASTING = RADIUS = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE D = LIMITS OF DISTURBANCEDDDDD D DDDDDDDDDDDDDDDDDDDDDD D D D D D D D D DD D D D DDDDDDDD DDDDDD D D D D D D DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD146TH STREET VAR. WIDTH ROW PARKHURSTBIRDSONG LANE 146TH STREET QUAIL POINT DRIVE BFE 886.8 BFE 886.9 BFE 886.7 BFE 886.5 BFE 886.3 BFE 886.2ZONE AE ZONE AE ZONE AE ZONE AE POND 1 26 1 7 8 9 11 12 10 13 28 27 24 25 23 16 17 18 14 3 2 5 4 29 30 31 32 33 34 1920 22 6 21 15 W W W W WWWWWWWWWWWWWWW WWWWWW W W W WW WWWWWWWWWWW W W W W WBEDFORDFALLS DR. GOWER DRIVE BIRDSONG LANEMITCHEL LANEBEDFORDFALLS DRIVE* ** * * * * * ** * * * * * * ** * * C.A. AC.A. A C.A. B C.A. A C.A. C C.A. C GUARDRAIL FMFMFMFMFMFMFM* * FMFMFMFMFMFMFMONLY Know what'sbelow. before you dig.Call R W S N E NOTES 1. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM TO CHAPTER 2 OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), CURRENT REVISION. 2. ALL ROOF DOWNSPOUTS, ROOF DRAINS, OR ROOF DRAINAGE PIPING SHALL DISCHARGE ONTO THE GROUND, AS A LEGAL DISCHARGE, OR DIRECTLY CONNECTED TO THE STORM DRAINAGE SYSTEM AS A LEGAL CONNECTION OR LEGAL DISCHARGE AS DEFINED IN THE CITY OF CARMEL PROPERTY MAINTENANCE CODE. 3. SQUARE POSTS SIZED IN ACCORDANCE WITH INDOT STANDARD DRAWING E 802-SNGS-07. ·UNREINFORCED ANCHOR BASE INSTALLED PER INDOT STANDARD DRAWING E 802-SNGS-09. ·FOR STREET NAME SIGNS USE TYPE 11 SQUARE POST ·FOR POSTS MOUNTED ON CONCRETE - SNAP-N-SAFE MODEL S200S (TYPE II POST) OR MODEL S225S (TYPE I POST) FLUSH MOUNT BRACKETS SHALL BE USED. 4. SIGN TYPE/PLACEMENT IN ACCORDANCE WITH THE CURRENT INDIANA MUTCD. ALL SIGNS, TEMPORARY TRAFFIC CONTROL SIGNS AND BARRICADES MUST COMPLY WITH THE CURRENT INDIANA MUTCD. 5. SIGN MATERIALS IN ACCORDANCE WITH INDOT STANDARD SPECIFICATIONS SEC 919. ·SIGN SHEETING IN ASTM TYPE IV OR BETTER ·WARNING SIGNS SHALL BE FLUORESCENT YELLOW ·PEDESTRIAN SIGNS SHALL BE FLUORESCENT YELLOW-GREEN 6. PER MUTCD, STREET NAME SIGNS ON MULTI-LANE FACILITIES MUST HAVE 8" CAPITAL LETTER/NUMBERS AND 6" LOWERCASE LETTERS ON AN 18" BLADE. ·STREET NAMES SIGNS SHALL HAVE WHITE BORDERS ·18" BLADES WILL BE SINGLE SIDED AND BOLTED DIRECTLY TO THE POST. ··POST LENGTH MUST BE INCREASED BY 36" ··DEPENDING NO BLADE LENGTH, SCRAP POST SHOULD BE BOLTED BETWEEN TWO SINGLE SIDED BLADES FOR SUPPORT. TRAFFIC LEGEND SYMBOL TYPE SPECIFICATION QUANTITY SPEED LIMIT (20 MPH) FIG, P-15D 3 STOP SIGN R1-1 6 STREET SIGN FIG, P-15D 3 STREET LIGHT SEE DETAIL 4 NO LEFT TURN R3-2 2 ONE WAY R6-1R 1 KEEP RIGHT R4-7 1 OM3-L 1 C406 Sign & SSD PlanC406SIGN & SSD PLANW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C406 Sign & SSD Plan.dwgLAYOUT: C406DATE/TIME: August 31, 2022 - 10:54amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) 11/07/22 C407 Street DetailsC407STREET DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C407 Street Details.dwgLAYOUT: C407DATE/TIME: August 31, 2022 - 10:54amPLOTTED BY: hansenbfhgENGINE E RS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, Indiana11/07/22 C407 Street DetailsC408STREET DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C407 Street Details.dwgLAYOUT: C408DATE/TIME: August 31, 2022 - 10:54amPLOTTED BY: hansenbfhgENGINE E RS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, Indiana11/07/22 C407 Street DetailsC408STREET DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C407 Street Details.dwgLAYOUT: C409DATE/TIME: August 31, 2022 - 10:54amPLOTTED BY: hansenbfhgENGINE E RS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, Indiana11/07/22 KIRKLEES DRIVE26178911121013282724252316171814325429303132333419202262115WWWW W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWWWWWW******************SANSANSANSANC.A. AC.A. AC.A.BC.A. AC.A. CSANSANSANSANSANSANSANSANSANFMFMFMFMFMFMFMBE DFOR D FA LLS D R.GOWER DRIVEBIRDSONGLANEMITCHEL LANE BEDFORD FALLS DRIVEFMFMFMFMFMFMFM 870 875 880 885 890 895 900 905 870 875 880 885 890 895 900 905 FINISHED GRADE EXISTING GRADE PROFILE LEGENDCONCRETE CRADLELEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE Know what'sbelow. before you dig.Call R N W E S SANITARY SEWER NOTES 1. THE CONTRACTOR SHALL CONTACT APPLICABLE UNDERGROUND-PLANT PROTECTION/LOCATION SERVICE AT LEAST 72 HOURS PRIOR TO ANY WORK. 2. THE CONTRACTOR SHALL CONTACT THE OWNER AND/OR ENGINEER IF UTILITIES APPEAR TO BE IN CONFLICT WITH THE PROPOSED IMPROVEMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 3. THE PLANS SHOW THE LOCATION OF ALL KNOWN UTILITIES LOCATED WITHIN THE LIMITS OF CONSTRUCTION ACCORDING TO INFORMATION PROVIDED BY THE VARIOUS UTILITY COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS EVIDENCED BY OBSERVATION OF ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE ACCURACY OF THIS INFORMATION IS NOT GUARANTEED. 4. THE LOCATION AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION IS THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 5. THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITY OWNERS TO VERIFY ANY AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF UTILITIES. 6. ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A. STANDARDS FOR WORKER SAFETY. 7. ANY PART OF SANITARY TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL. 8. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATION, SIZE, AND ELEVATION OF EXISTING UTILITIES, STRUCTURES, PIPES, AND PAVEMENTS. AS RELATED TO THEIR WORK. NOTIFY ENGINEER OF ANY CONFLICT AND/OR DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS. 9. CLEARANCE BETWEEN STORM / SANITARY SEWER SYSTEMS AND DOMESTIC/FIRE LINE SERVICE, SHALL BE MAINTAINED AT 10' HORIZONTAL AND 18" VERTICAL. 10. CONTRACTOR TO INSTALL CONCRETE CRADLES AT PIPE CROSSINGS WHEN THE VERTICAL SEPARATION AS MEASURED FROM THE EXTERIOR OF THE PIPES, BETWEEN SANITARY SEWERS, WATER MAINS AND STORM SEWERS IS 18" OR LESS. 11. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO IT'S CONDITION PRIOR TO CONSTRUCTION. 12. WHEN PERFORMING EXCAVATIONS DURING PERIODS OF WET WEATHER, PROVIDE ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS. 13. COMPACTED "B" BORROW BACK FILL REQUIRED OVER ALL UTILITIES IN PAVED AREAS. 14. ALL UTILITY STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT AND SHALL HAVE TRAFFIC BEARING RINGS AND COVERS RATED FOR H20 LOADING. 15. FOLLOW ALL LOCAL AND STATE CODES IN REFERENCE TO SANITARY SEWER INSTALLATION. 16. SANITARY SEWER LATERALS SHALL BE BACKFILLED WITH GRANULAR MATERIAL FOR THE ENTIRE LENGTH OF THE PIPE. 17. ALL EXISTING MANHOLES SHALL BE ADJUSTED TO NEW FINISH GRADE ELEVATIONS. 18. CLEANOUTS ARE REQUIRED WITHIN 18-60 INCHES OF THE BUILDING AND EVERY 100 FEET ALONG THE LATERAL. 19. LATERALS STATIONS ALONG GRAVITY MAIN ARE FROM THE NEAREST DOWNSTREAM MANHOLE. 20. REFER TO ASTM D2321 FOR INSTALLATION OF PVC SANITARY SEWER. 21. ALL SANITARY SEWER TO HAVE DEFLECTION AND LEAKAGE TESTING AS PER CODE 327 IAC 3-6-19.C500 Sanitary PnPC500SANITARY PLAN & PROFILEW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C500 Sanitary PnP.dwgLAYOUT: C500DATE/TIME: August 31, 2022 - 10:55amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) 11/07/22 SANITARY SEWER STRUCTURE DATA TABLE STRUCTURE NUMBER STRUCTURE TYPE TOP OF CASTING CASTING TYPE INVERT SANITARY SEWER PIPE DATA TABLE UPSTREAM STRUCTURE DOWNSTREAM STRUCTURE SIZE MATERIAL LENGTH SLOPEKIRKLEES DRIVE26178911121013282724252316171814325429303132333419202262115WWWW W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWWWWWW******************SANSANSANSANC.A. AC.A. AC.A.BC.A. AC.A. CSANSANSANSANSANSANSANSANSANFMFMFMFMFMFMFMBE DFOR D FA LLS D R.GOWER DRIVEBIRDSONGLANEMITCHEL LANE BEDFORD FALLS DRIVEFMFMFMFMFMFMFM 870 875 880 885 890 895 900 905 870 875 880 885 890 895 900 905 CONCRETE CRADLE0+001+00 2+003+00 FINISHED GRADE EXISTING GRADE PROFILE LEGEND LEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE BF-489 BF-491 BF-492 BF-493 BF-495 BF-496 KB-710 48'' DIA. MANHOLE 48'' DIA. MANHOLE 48'' DIA. MANHOLE 48'' DIA. MANHOLE 48'' DIA. MANHOLE 48'' DIA. MANHOLE EXISTING MANHOLE 898.03 897.11 895.00 897.04 897.77 893.63 893.28 R-1772 R-1772 R-1772 R-1772 R-1772 R-1772 EXISTING INV IN = 886.16(NW) INV OUT = 886.06(E) INV IN = 887.02(N) INV OUT = 886.92(SE) INV OUT = 888.63(S) INV IN = 885.07(NW) INV OUT = 884.97(S) INV IN = 885.51(N) INV IN = 885.51(W) INV OUT = 885.41(SE) INV OUT = 887.46(S) INV IN = 883.69(W) INV IN = 883.88(N) INV OUT = 883.68(SE) R-1916 BF-489 BF-491 BF-492 BF-493 BF-495 BF-496 BF-495 BF-489 BF-491 KB-710 BF-493 BF-495 8" 8" 8" 8" 8" 8" PVC PVC PVC PVC PVC PVC 130' 180' 383' 242' 75' 464' 0.42% 0.42% 0.42% 0.45% 0.45% 0.42% Know what'sbelow. before you dig.Call R SANITARY SEWER NOTES 1. THE CONTRACTOR SHALL CONTACT APPLICABLE UNDERGROUND-PLANT PROTECTION/LOCATION SERVICE AT LEAST 72 HOURS PRIOR TO ANY WORK. 2. THE CONTRACTOR SHALL CONTACT THE OWNER AND/OR ENGINEER IF UTILITIES APPEAR TO BE IN CONFLICT WITH THE PROPOSED IMPROVEMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 3. THE PLANS SHOW THE LOCATION OF ALL KNOWN UTILITIES LOCATED WITHIN THE LIMITS OF CONSTRUCTION ACCORDING TO INFORMATION PROVIDED BY THE VARIOUS UTILITY COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS EVIDENCED BY OBSERVATION OF ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE ACCURACY OF THIS INFORMATION IS NOT GUARANTEED. 4. THE LOCATION AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION IS THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 5. THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITY OWNERS TO VERIFY ANY AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF UTILITIES. 6. ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A. STANDARDS FOR WORKER SAFETY. 7. ANY PART OF SANITARY TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL. 8. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATION, SIZE, AND ELEVATION OF EXISTING UTILITIES, STRUCTURES, PIPES, AND PAVEMENTS. AS RELATED TO THEIR WORK. NOTIFY ENGINEER OF ANY CONFLICT AND/OR DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS. 9. CLEARANCE BETWEEN STORM / SANITARY SEWER SYSTEMS AND DOMESTIC/FIRE LINE SERVICE, SHALL BE MAINTAINED AT 10' HORIZONTAL AND 18" VERTICAL. 10. CONTRACTOR TO INSTALL CONCRETE CRADLES AT PIPE CROSSINGS WHEN THE VERTICAL SEPARATION AS MEASURED FROM THE EXTERIOR OF THE PIPES, BETWEEN SANITARY SEWERS, WATER MAINS AND STORM SEWERS IS 18" OR LESS. 11. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO IT'S CONDITION PRIOR TO CONSTRUCTION. 12. WHEN PERFORMING EXCAVATIONS DURING PERIODS OF WET WEATHER, PROVIDE ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS. 13. COMPACTED "B" BORROW BACK FILL REQUIRED OVER ALL UTILITIES IN PAVED AREAS. 14. ALL UTILITY STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT AND SHALL HAVE TRAFFIC BEARING RINGS AND COVERS RATED FOR H20 LOADING. 15. FOLLOW ALL LOCAL AND STATE CODES IN REFERENCE TO SANITARY SEWER INSTALLATION. 16. SANITARY SEWER LATERALS SHALL BE BACKFILLED WITH GRANULAR MATERIAL FOR THE ENTIRE LENGTH OF THE PIPE. 17. ALL EXISTING MANHOLES SHALL BE ADJUSTED TO NEW FINISH GRADE ELEVATIONS. 18. CLEANOUTS ARE REQUIRED WITHIN 18-60 INCHES OF THE BUILDING AND EVERY 100 FEET ALONG THE LATERAL. 19. LATERALS STATIONS ALONG GRAVITY MAIN ARE FROM THE NEAREST DOWNSTREAM MANHOLE. 20. REFER TO ASTM D2321 FOR INSTALLATION OF PVC SANITARY SEWER. 21. ALL SANITARY SEWER TO HAVE DEFLECTION AND LEAKAGE TESTING AS PER CODE 327 IAC 3-6-19.C500 Sanitary PnPC501SANITARY PLAN & PROFILEW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C500 Sanitary PnP.dwgLAYOUT: C501DATE/TIME: August 31, 2022 - 10:55amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) N W E S 11/07/22 C501 Sanitary SpecsC501SANITARY SPECIFICATIONS & DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C501 Sanitary Specs.dwgLAYOUT: C501DATE/TIME: February 16, 2022 - 11:26amPLOTTED BY: hansenbfhgENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, Indiana11/07/22 C501 Sanitary SpecsC502SANITARY SPECIFICATIONS & DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C501 Sanitary Specs.dwgLAYOUT: C502DATE/TIME: August 31, 2022 - 10:55amPLOTTED BY: hansenbfhgENGINE E RS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, Indiana11/07/22 C501 Sanitary SpecsC503SANITARY SPECIFICATIONS & DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C501 Sanitary Specs.dwgLAYOUT: C503DATE/TIME: August 31, 2022 - 10:55amPLOTTED BY: hansenbfhgENGINE E RS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, Indiana11/07/22 W W W W W W W W EG G G G G G G G G G G G G G G G G G G G G G G GG WOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU W W W W W W W W W W WSTREET BFE 886.8 BFE 886.9 BFE 886.7 BFE 886.5 BFE 886.3 BFE 886.2ZONE AE ZONE AE ZONE AE ZONE AE POND 1 1 24 23 16 17 18 2 33 34 1920 22 21 WWWWWWWWWWWWWWWW W W W W WBEDFORDFALLS DR.GOWER DRIVE * ** * * * * * * * * * C.A. A C.A. C C.A. C GUARDRAIL FMFMFMFMFMFMFM* * FMFMFMFMFMFMFM870 875 880 885 890 895 900 905 910 870 875 880 885 890 895 900 905 910 FINISHED GRADE EXISTING GRADE PROFILE LEGEND LEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE Know what'sbelow. before you dig.Call R W S N E STORM SEWER NOTES 1. THE CONTRACTOR SHALL ADHERE TO ALL TERMS AND CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL N.P.D.E.S. PERMIT FOR STORMWATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND STORMWATER POLLUTION PREVENTION PLAN. 2. REFER TO THE INDIANA DEPARTMENT OF TRANSPORTATION (INDOT) STANDARD SPECIFICATIONS, LATEST EDITION, FOR BASIC MATERIALS AND CONSTRUCTION METHODS. 3. THE CONTRACTOR SHALL CONTACT APPLICABLE STATE UNDERGROUND LOCATION SERVICE AT LEAST 72 HOURS PRIOR TO ANY WORK AND SHALL CONTACT THE OWNER AND/OR ENGINEER SHOULD UTILITIES APPEAR TO BE IN CONFLICT WITH THE PROPOSED IMPROVEMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 4. THE PLANS SHOW THE LOCATIONS OF ALL KNOWN UTILITIES LOCATED WITHIN THE LIMITS OF CONSTRUCTION ACCORDING TO INFORMATION PROVIDED BY THE VARIOUS UTILITY COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS EVIDENCED BY OBSERVATION OF ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE ACCURACY OF THIS INFORMATION IS NOT GUARANTEED. 5. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE MAINS, CONDUITS, SERVICE LINES, AND OTHER FACILITIES WITHIN THE CONSTRUCTION LIMITS. THE LOCATION AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE UTILITY COMPANY) IS THE EXPRESSED RESPONSIBILITY OF THE CONTRACTOR. 6. THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITIES AND VERIFY ANY AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF ALL UTILITIES. 7. ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A. STANDARDS FOR WORKER SAFETY. 8. ANY PART OF STORM SEWER TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL. 9. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATIONS, SIZES, AND ELEVATIONS OF EXISTING UTILITIES, STRUCTURES, PIPES, PAVEMENTS AS RELATED TO THEIR WORK. NOTIFY ENGINEER OF ANY CONFLICT AND/OR DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS. 10. MINIMUM CLEARANCE BETWEEN STORM / SANITARY SEWER SYSTEMS AND DOMESTIC/FIRE LINE SERVICE, SHALL BE 10' HORIZONTAL AND 18" VERTICAL. 11. CONTRACTOR TO INSTALL CONCRETE CRADLES AT PIPE CROSSING WHEN THE VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWERS, WATER MAINS AND STORM SEWERS IS 18" OR LESS. 12. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO IT'S CONDITION PRIOR TO CONSTRUCTION. 13. WHEN PERFORMING EXCAVATIONS DURING PERIODS OF WET WEATHER, PROVIDE ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS. 14. COMPACTED "B" BORROW BACK FILL REQUIRED OVER ALL UTILITIES IN PAVED AREAS. 15. FOLLOW ALL LOCAL AND STATE CODES IN REFERENCE TO STORM SEWER INSTALLATION. 16. ALL EXISTING MANHOLE AND CATCH BASIN GRATES SHALL BE ADJUSTED TO NEW FINISH GRADE ELEVATIONS. 17. EXISTING PIPES WITHIN CONSTRUCTION LIMITS ARE TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS. 18. ALL STORM PIPE CONNECTIONS AT STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTIONS AT STRUCTURES ARE WATERTIGHT. 19. ALL STORM SEWER STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT AND SHALL HAVE TRAFFIC BEARING RING AND COVERS RATED FOR H20 LOADING. 20. ALL STORM SEWER STRUCTURES SHALL HAVE A SMOOTH AND UNIFORMLY POURED MORTAR CHANNEL FROM INVERT IN TO INVERT OUT. 21. NEW PIPES AND STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS PRIOR TO FINAL TURNOVER TO THE OWNER. 22. IF HDPE PIPE IS SPECIFIED, USE DUAL WALLED, HANCOR HQ, ADS N-12 PIPE OR APPROVED EQUAL. 23. ALL FITTINGS AND ACCESSORIES INCLUDING BUT NOT LIMITED TO END CAPS, CLEANOUTS, REDUCERS, ETC., SHALL BE HDPE MATERIAL; IF SPECIFIED, COMPARABLE WITH STORAGE PIPES. 24. PROVIDE BACKFILL WITH A MINIMUM OF 4" BEDDING MATERIAL OF #8 AGGREGATE COMPACTED IN 8" LIFTS TO 95% MAXIMUM DRY DENSITY. 25. VERIFY EXISTING STORM INVERT ELEVATIONS PRIOR TO STARTING NEW STORM SEWER CONNECTION. 26. PROPOSED STORM SEWERS TO BE OWNED BY HAMILTON COUNTY.C600 Storm PnPC600STORM PLAN & PROFILEW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C600 Storm PnP.dwgLAYOUT: C600DATE/TIME: August 31, 2022 - 10:56amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) STORM SEWER CONSTRUCTION NOTES THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. 11/07/22 ZONE AE POND 1 1 23 18 34 1920 22 21 WWWWWWWWWW W W W W W * ** * * * * * * * C.A. A C.A. C C.A. C FMFMFMFMFMFMFMBEDFORDFALLS DR.GOWER DRIVE FMFMFMFMFMFMFM870 875 880 885 890 895 900 905 910 870 875 880 885 890 895 900 905 910 LEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE Know what'sbelow. before you dig.Call R W S N E STORM SEWER NOTES 1. THE CONTRACTOR SHALL ADHERE TO ALL TERMS AND CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL N.P.D.E.S. PERMIT FOR STORMWATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND STORMWATER POLLUTION PREVENTION PLAN. 2. REFER TO THE INDIANA DEPARTMENT OF TRANSPORTATION (INDOT) STANDARD SPECIFICATIONS, LATEST EDITION, FOR BASIC MATERIALS AND CONSTRUCTION METHODS. 3. THE CONTRACTOR SHALL CONTACT APPLICABLE STATE UNDERGROUND LOCATION SERVICE AT LEAST 72 HOURS PRIOR TO ANY WORK AND SHALL CONTACT THE OWNER AND/OR ENGINEER SHOULD UTILITIES APPEAR TO BE IN CONFLICT WITH THE PROPOSED IMPROVEMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 4. THE PLANS SHOW THE LOCATIONS OF ALL KNOWN UTILITIES LOCATED WITHIN THE LIMITS OF CONSTRUCTION ACCORDING TO INFORMATION PROVIDED BY THE VARIOUS UTILITY COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS EVIDENCED BY OBSERVATION OF ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE ACCURACY OF THIS INFORMATION IS NOT GUARANTEED. 5. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE MAINS, CONDUITS, SERVICE LINES, AND OTHER FACILITIES WITHIN THE CONSTRUCTION LIMITS. THE LOCATION AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE UTILITY COMPANY) IS THE EXPRESSED RESPONSIBILITY OF THE CONTRACTOR. 6. THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITIES AND VERIFY ANY AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF ALL UTILITIES. 7. ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A. STANDARDS FOR WORKER SAFETY. 8. ANY PART OF STORM SEWER TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL. 9. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATIONS, SIZES, AND ELEVATIONS OF EXISTING UTILITIES, STRUCTURES, PIPES, PAVEMENTS AS RELATED TO THEIR WORK. NOTIFY ENGINEER OF ANY CONFLICT AND/OR DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS. 10. MINIMUM CLEARANCE BETWEEN STORM / SANITARY SEWER SYSTEMS AND DOMESTIC/FIRE LINE SERVICE, SHALL BE 10' HORIZONTAL AND 18" VERTICAL. 11. CONTRACTOR TO INSTALL CONCRETE CRADLES AT PIPE CROSSING WHEN THE VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWERS, WATER MAINS AND STORM SEWERS IS 18" OR LESS. 12. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO IT'S CONDITION PRIOR TO CONSTRUCTION. 13. WHEN PERFORMING EXCAVATIONS DURING PERIODS OF WET WEATHER, PROVIDE ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS. 14. COMPACTED "B" BORROW BACK FILL REQUIRED OVER ALL UTILITIES IN PAVED AREAS. 15. FOLLOW ALL LOCAL AND STATE CODES IN REFERENCE TO STORM SEWER INSTALLATION. 16. ALL EXISTING MANHOLE AND CATCH BASIN GRATES SHALL BE ADJUSTED TO NEW FINISH GRADE ELEVATIONS. 17. EXISTING PIPES WITHIN CONSTRUCTION LIMITS ARE TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS. 18. ALL STORM PIPE CONNECTIONS AT STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTIONS AT STRUCTURES ARE WATERTIGHT. 19. ALL STORM SEWER STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT AND SHALL HAVE TRAFFIC BEARING RING AND COVERS RATED FOR H20 LOADING. 20. ALL STORM SEWER STRUCTURES SHALL HAVE A SMOOTH AND UNIFORMLY POURED MORTAR CHANNEL FROM INVERT IN TO INVERT OUT. 21. NEW PIPES AND STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS PRIOR TO FINAL TURNOVER TO THE OWNER. 22. IF HDPE PIPE IS SPECIFIED, USE DUAL WALLED, HANCOR HQ, ADS N-12 PIPE OR APPROVED EQUAL. 23. ALL FITTINGS AND ACCESSORIES INCLUDING BUT NOT LIMITED TO END CAPS, CLEANOUTS, REDUCERS, ETC., SHALL BE HDPE MATERIAL; IF SPECIFIED, COMPARABLE WITH STORAGE PIPES. 24. PROVIDE BACKFILL WITH A MINIMUM OF 4" BEDDING MATERIAL OF #8 AGGREGATE COMPACTED IN 8" LIFTS TO 95% MAXIMUM DRY DENSITY. 25. VERIFY EXISTING STORM INVERT ELEVATIONS PRIOR TO STARTING NEW STORM SEWER CONNECTION. 26. PROPOSED STORM SEWERS TO BE OWNED BY HAMILTON COUNTY.C600 Storm PnPC601STORM PLAN & PROFILEW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C600 Storm PnP.dwgLAYOUT: C601DATE/TIME: August 31, 2022 - 10:57amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) STORM SEWER CONSTRUCTION NOTES THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. 11/07/22 870 875 880 885 890 895 900 905 870 875 880 885 890 895 900 905 FINISHED GRADE EXISTING GRADE PROFILE LEGEND CONCRETE CRADLE2617891112101328272425233254293031323334192022621WW W W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWWWWWW****************C.A. AC.A.BC.A. AC.A. CFMFMFMFMFMFMFMBE DFOR D F A LLS DR.GOWER DRIVEBIRDSONGLANEMITCHEL LANE BEDFORD FALLS DRIVEFMFMFMFMFMFMFM LEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE Know what'sbelow. before you dig.Call R N W E S STORM SEWER NOTES 1. THE CONTRACTOR SHALL ADHERE TO ALL TERMS AND CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL N.P.D.E.S. PERMIT FOR STORMWATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND STORMWATER POLLUTION PREVENTION PLAN. 2. REFER TO THE INDIANA DEPARTMENT OF TRANSPORTATION (INDOT) STANDARD SPECIFICATIONS, LATEST EDITION, FOR BASIC MATERIALS AND CONSTRUCTION METHODS. 3. THE CONTRACTOR SHALL CONTACT APPLICABLE STATE UNDERGROUND LOCATION SERVICE AT LEAST 72 HOURS PRIOR TO ANY WORK AND SHALL CONTACT THE OWNER AND/OR ENGINEER SHOULD UTILITIES APPEAR TO BE IN CONFLICT WITH THE PROPOSED IMPROVEMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 4. THE PLANS SHOW THE LOCATIONS OF ALL KNOWN UTILITIES LOCATED WITHIN THE LIMITS OF CONSTRUCTION ACCORDING TO INFORMATION PROVIDED BY THE VARIOUS UTILITY COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS EVIDENCED BY OBSERVATION OF ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE ACCURACY OF THIS INFORMATION IS NOT GUARANTEED. 5. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE MAINS, CONDUITS, SERVICE LINES, AND OTHER FACILITIES WITHIN THE CONSTRUCTION LIMITS. THE LOCATION AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE UTILITY COMPANY) IS THE EXPRESSED RESPONSIBILITY OF THE CONTRACTOR. 6. THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITIES AND VERIFY ANY AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF ALL UTILITIES. 7. ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A. STANDARDS FOR WORKER SAFETY. 8. ANY PART OF STORM SEWER TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL. 9. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATIONS, SIZES, AND ELEVATIONS OF EXISTING UTILITIES, STRUCTURES, PIPES, PAVEMENTS AS RELATED TO THEIR WORK. NOTIFY ENGINEER OF ANY CONFLICT AND/OR DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS. 10. MINIMUM CLEARANCE BETWEEN STORM / SANITARY SEWER SYSTEMS AND DOMESTIC/FIRE LINE SERVICE, SHALL BE 10' HORIZONTAL AND 18" VERTICAL. 11. CONTRACTOR TO INSTALL CONCRETE CRADLES AT PIPE CROSSING WHEN THE VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWERS, WATER MAINS AND STORM SEWERS IS 18" OR LESS. 12. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO IT'S CONDITION PRIOR TO CONSTRUCTION. 13. WHEN PERFORMING EXCAVATIONS DURING PERIODS OF WET WEATHER, PROVIDE ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS. 14. COMPACTED "B" BORROW BACK FILL REQUIRED OVER ALL UTILITIES IN PAVED AREAS. 15. FOLLOW ALL LOCAL AND STATE CODES IN REFERENCE TO STORM SEWER INSTALLATION. 16. ALL EXISTING MANHOLE AND CATCH BASIN GRATES SHALL BE ADJUSTED TO NEW FINISH GRADE ELEVATIONS. 17. EXISTING PIPES WITHIN CONSTRUCTION LIMITS ARE TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS. 18. ALL STORM PIPE CONNECTIONS AT STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTIONS AT STRUCTURES ARE WATERTIGHT. 19. ALL STORM SEWER STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT AND SHALL HAVE TRAFFIC BEARING RING AND COVERS RATED FOR H20 LOADING. 20. ALL STORM SEWER STRUCTURES SHALL HAVE A SMOOTH AND UNIFORMLY POURED MORTAR CHANNEL FROM INVERT IN TO INVERT OUT. 21. NEW PIPES AND STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS PRIOR TO FINAL TURNOVER TO THE OWNER. 22. IF HDPE PIPE IS SPECIFIED, USE DUAL WALLED, HANCOR HQ, ADS N-12 PIPE OR APPROVED EQUAL. 23. ALL FITTINGS AND ACCESSORIES INCLUDING BUT NOT LIMITED TO END CAPS, CLEANOUTS, REDUCERS, ETC., SHALL BE HDPE MATERIAL; IF SPECIFIED, COMPARABLE WITH STORAGE PIPES. 24. PROVIDE BACKFILL WITH A MINIMUM OF 4" BEDDING MATERIAL OF #8 AGGREGATE COMPACTED IN 8" LIFTS TO 95% MAXIMUM DRY DENSITY. 25. VERIFY EXISTING STORM INVERT ELEVATIONS PRIOR TO STARTING NEW STORM SEWER CONNECTION. 26. PROPOSED STORM SEWERS TO BE OWNED BY HAMILTON COUNTY.C600 Storm PnPC602STORM PLAN & PROFILEW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C600 Storm PnP.dwgLAYOUT: C602DATE/TIME: August 31, 2022 - 10:57amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) STORM SEWER CONSTRUCTION NOTES THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. 11/07/22 C603 Storm DetailsC604STORM DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C603 Storm Details.dwgLAYOUT: C603DATE/TIME: March 30, 2022 - 4:15pmPLOTTED BY: hansenbfhgENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, Indiana11/07/22 870 875 880 885 890 895 900 905 870 875 880 885 890 895 900 905 FINISHED GRADE EXISTING GRADE PROFILE LEGENDCONCRETE CRADLE26178911121013282724252316171814325429303132333419202262115WWWW W W W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWWWWW******************C.A. AC.A.BC.A. AC.A. CFMFMFMFMFMFMFMBE DFOR D FA LLS D R.GOWER DRIVEBIRDSONGLANEMITCHEL LANE BEDFORD FALLS DRIVEFMFMFMFMFMFMFM LEGEND = EXISTING STORM SEWER LINE = SWALE = EXISTING SANITARY SEWER LINE = PROPOSED SANITARY SEWER LINE = PROPOSED STORM SEWER LINE = SANITARY SEWER MANHOLE = STORM MANHOLE = STORM INLET UD = SOLID WALL UNDERDRAIN SSD = SUBSURFACE DRAIN U.E. TOC INV. RCP M.H. STR. D.&U.E. M.E. PROP. TYP. R. EX. S.S.E. = TOP OF CASTING = INVERT = REINFORCED CONCRETE PIPE = MANHOLE = STRUCTURE = DRAINAGE AND UTILITY EASEMENT = UTILITY EASEMENT = SANITARY SEWER EASEMENT = MATCH EXISTING GRADE = TYPICAL = PROPOSED = EXISTING = RADIUS = VARIABLE WIDTHV.W. = BUILDING SETBACK LINE (B.S.L.) = EASEMENT ROW = RIGHT-OF-WAY CL = CENTERLINE PVC = POLYVINYL CHLORIDE PIPE B-B = BACK TO BACK (CURB) = SUBSURFACE DRAIN AND SUMP LINE Know what'sbelow. before you dig.Call R N W E S STORM SEWER NOTES 1. THE CONTRACTOR SHALL ADHERE TO ALL TERMS AND CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL N.P.D.E.S. PERMIT FOR STORMWATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND STORMWATER POLLUTION PREVENTION PLAN. 2. REFER TO THE INDIANA DEPARTMENT OF TRANSPORTATION (INDOT) STANDARD SPECIFICATIONS, LATEST EDITION, FOR BASIC MATERIALS AND CONSTRUCTION METHODS. 3. THE CONTRACTOR SHALL CONTACT APPLICABLE STATE UNDERGROUND LOCATION SERVICE AT LEAST 72 HOURS PRIOR TO ANY WORK AND SHALL CONTACT THE OWNER AND/OR ENGINEER SHOULD UTILITIES APPEAR TO BE IN CONFLICT WITH THE PROPOSED IMPROVEMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 4. THE PLANS SHOW THE LOCATIONS OF ALL KNOWN UTILITIES LOCATED WITHIN THE LIMITS OF CONSTRUCTION ACCORDING TO INFORMATION PROVIDED BY THE VARIOUS UTILITY COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS EVIDENCED BY OBSERVATION OF ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE ACCURACY OF THIS INFORMATION IS NOT GUARANTEED. 5. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE MAINS, CONDUITS, SERVICE LINES, AND OTHER FACILITIES WITHIN THE CONSTRUCTION LIMITS. THE LOCATION AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE UTILITY COMPANY) IS THE EXPRESSED RESPONSIBILITY OF THE CONTRACTOR. 6. THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITIES AND VERIFY ANY AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF ALL UTILITIES. 7. ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A. STANDARDS FOR WORKER SAFETY. 8. ANY PART OF STORM SEWER TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL. 9. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATIONS, SIZES, AND ELEVATIONS OF EXISTING UTILITIES, STRUCTURES, PIPES, PAVEMENTS AS RELATED TO THEIR WORK. NOTIFY ENGINEER OF ANY CONFLICT AND/OR DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS. 10. MINIMUM CLEARANCE BETWEEN STORM / SANITARY SEWER SYSTEMS AND DOMESTIC/FIRE LINE SERVICE, SHALL BE 10' HORIZONTAL AND 18" VERTICAL. 11. CONTRACTOR TO INSTALL CONCRETE CRADLES AT PIPE CROSSING WHEN THE VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWERS, WATER MAINS AND STORM SEWERS IS 18" OR LESS. 12. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO IT'S CONDITION PRIOR TO CONSTRUCTION. 13. WHEN PERFORMING EXCAVATIONS DURING PERIODS OF WET WEATHER, PROVIDE ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS. 14. COMPACTED "B" BORROW BACK FILL REQUIRED OVER ALL UTILITIES IN PAVED AREAS. 15. FOLLOW ALL LOCAL AND STATE CODES IN REFERENCE TO STORM SEWER INSTALLATION. 16. ALL EXISTING MANHOLE AND CATCH BASIN GRATES SHALL BE ADJUSTED TO NEW FINISH GRADE ELEVATIONS. 17. EXISTING PIPES WITHIN CONSTRUCTION LIMITS ARE TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS. 18. ALL STORM PIPE CONNECTIONS AT STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTIONS AT STRUCTURES ARE WATERTIGHT. 19. ALL STORM SEWER STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT AND SHALL HAVE TRAFFIC BEARING RING AND COVERS RATED FOR H20 LOADING. 20. ALL STORM SEWER STRUCTURES SHALL HAVE A SMOOTH AND UNIFORMLY POURED MORTAR CHANNEL FROM INVERT IN TO INVERT OUT. 21. NEW PIPES AND STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS PRIOR TO FINAL TURNOVER TO THE OWNER. 22. IF HDPE PIPE IS SPECIFIED, USE DUAL WALLED, HANCOR HQ, ADS N-12 PIPE OR APPROVED EQUAL. 23. ALL FITTINGS AND ACCESSORIES INCLUDING BUT NOT LIMITED TO END CAPS, CLEANOUTS, REDUCERS, ETC., SHALL BE HDPE MATERIAL; IF SPECIFIED, COMPARABLE WITH STORAGE PIPES. 24. PROVIDE BACKFILL WITH A MINIMUM OF 4" BEDDING MATERIAL OF #8 AGGREGATE COMPACTED IN 8" LIFTS TO 95% MAXIMUM DRY DENSITY. 25. VERIFY EXISTING STORM INVERT ELEVATIONS PRIOR TO STARTING NEW STORM SEWER CONNECTION. 26. PROPOSED STORM SEWERS TO BE OWNED BY HAMILTON COUNTY.C600 Storm PnPC603STORM PLAN & PROFILEW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C600 Storm PnP.dwgLAYOUT: C603DATE/TIME: August 31, 2022 - 10:57amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) STORM SEWER CONSTRUCTION NOTES THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. 11/07/22 C603 Storm DetailsC605STORM DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C603 Storm Details.dwgLAYOUT: C603DATE/TIME: July 21, 2022 - 11:54amPLOTTED BY: hansenbfhgENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, Indiana11/07/22 STORM SEWER STRUCTURE DATA TABLE STRUCTURE NUMBER WQ601 497 498 499 600 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 TOP OF CASTING 890.56 892.22 883.42 885.94 885.68 890.17 890.00 889.80 889.70 890.40 891.05 891.04 889.30 888.70 893.90 894.53 894.53 894.10 891.23 891.24 891.24 STRUCTURE TYPE WATER QUALITY STRUCTURE, 96'' DIA. EXISTING FLARED END SECTION EXISTING FLARED END SECTION EXISTING MANHOLE FLARED END SECTION, 30'' DIA. 48'' DIA. MANHOLE BEEHIVE INLET, 60'' DIA. BEEHIVE INLET, 60'' DIA. BEEHIVE INLET, 60'' DIA. BEEHIVE INLET, 48'' DIA. CURB INLET, 48'' DIA. CURB INLET, 48'' DIA. BEEHIVE INLET, 24 X 24 BEEHIVE INLET, 48'' DIA. BEEHIVE INLET, 48'' DIA. CURB INLET, 48'' DIA. CURB INLET, 48'' DIA. BEEHIVE INLET, 48'' DIA. BEEHIVE INLET, 24 X 24 CURB INLET, 48'' DIA. CURB INLET, 48'' DIA. CASTING TYPE PER MANUFACTURER N/A N/A EXISTING N/A R-1772 R-4342 R-4342 R-4342 R-4342 R-3501-TR R-3501-TR R-4342 R-4342 R-4342 R-3501-TR R-3501-TL R-4342 R-4342 R-3501-TR R-3501-TL INVERT INV IN (S)= 883.34 (15" RCP) INV OUT (S)= 883.34 (15" RCP) INV OUT (W)= 890.97 (12" EX. STM) INV IN (W)= 880.00 (36" EX. STM) INV IN (NW)= 879.95 (36" EX. STM) INV OUT (E)= 879.95 (36" EX. STM) INV IN (W)= 882.80 (30" RCP) INV IN (W)= 883.41 (30" RCP) INV IN (S)= 883.41 (15" RCP) INV IN (N)= 883.27 (15" RCP) INV OUT (E)= 883.27 (30" RCP) INV OUT (N)= 883.41 (15" RCP) INV IN (N)= 883.70 (30" RCP) INV OUT (E)= 883.60 (30" RCP) INV IN (W)= 884.30 (30" RCP) INV OUT (S)= 884.20 (30" RCP) INV IN (S)= 885.12 (24" RCP) INV IN (W)= 884.72 (15" RCP) INV OUT (E)= 884.62 (30" RCP) INV IN (W)= 885.30 (15" RCP) INV OUT (E)= 885.20 (15" RCP) INV IN (SW)= 885.60 (12" RCP) INV OUT (E)= 885.50 (15" RCP) INV IN (W)= 885.94 (12" RCP) INV OUT (NE)= 885.84 (12" RCP) INV OUT (E)= 886.10 (12" RCP) INV IN (S)= 883.95 (15" RCP) INV OUT (N)= 883.85 (15" RCP) INV IN (S)= 885.40 (15" RCP) INV OUT (N)= 885.30 (15" RCP) INV IN (S)= 885.95 (15" RCP) INV OUT (N)= 885.85 (15" RCP) INV IN (S)= 886.20 (15" RCP) INV OUT (N)= 886.10 (15" RCP) INV IN (S)= 886.70 (15" RCP) INV OUT (N)= 886.60 (15" RCP) INV IN (W)= 887.40 (12" RCP) INV OUT (N)= 887.30 (15" RCP) INV IN (S)= 886.01 (24" RCP) INV OUT (N)= 885.91 (24" RCP) INV IN (S)= 886.41 (21" RCP) INV OUT (N)= 886.16 (24" RCP) STORM SEWER STRUCTURE DATA TABLE STRUCTURE NUMBER 618 620 621 622 623 624 625 626 627 628 629 630 631A 631 632 633 634 635 640 641 642 TOP OF CASTING 892.10 894.80 896.74 896.74 892.50 893.00 893.40 894.77 894.79 893.40 893.55 893.55 885.72 889.20 893.46 890.19 888.83 890.12 886.10 890.90 896.92 STRUCTURE TYPE BEEHIVE INLET, 48'' DIA. BEEHIVE INLET, 48'' DIA. CURB INLET, 24 X 24 CURB INLET, 24 X 24 BEEHIVE INLET, 24 X 24 BEEHIVE INLET, 24 X 24 BEEHIVE INLET, 24 X 24 CURB INLET, 48'' DIA. CURB INLET, 48'' DIA. BEEHIVE INLET, 24 X 24 CURB INLET, 24 X 24 CURB INLET, 24 X 24 FLARED END SECTION, 36'' DIA. BEEHIVE INLET, 60'' DIA. 60'' DIA. MANHOLE BEEHIVE INLET, 60'' DIA. FLARED END SECTION, 12'' DIA. FLARED END SECTION, 12'' DIA. OUTLET CONTROL STRUCTURE, 48 X 48 FLARED END SECTION, 12'' DIA. CURB INLET, 24 X 24 CASTING TYPE R-4342 R-4342 R-3501-TR R-3501-TR R-4342 R-4342 R-4342 R-3501-TL R-3501-TR R-4342 R-3501-TR R-3501-TL N/A R-4342 R-1772 R-4342 N/A N/A SEE DETAIL N/A R-3501-TL INVERT INV IN (S)= 887.85 (15" RCP) INV IN (W)= 887.85 (15" RCP) INV IN (E)= 888.10 (12" RCP) INV OUT (N)= 887.35 (21" RCP) INV IN (W)= 890.90 (12" RCP) INV IN (E)= 890.90 (12" RCP) INV OUT (N)= 890.65 (15" RCP) INV IN (SW)= 892.54 (12" RCP) INV OUT (E)= 892.44 (12" RCP) INV OUT (NE)= 892.74 (12" RCP) INV IN (W)= 889.30 (12" RCP) INV OUT (E)= 889.20 (12" RCP) INV IN (NW)= 889.80 (12" RCP) INV OUT (E)= 889.70 (12" RCP) INV OUT (SE)= 890.20 (12" RCP) INV IN (W)= 889.45 (12" RCP) INV OUT (E)= 889.20 (15" RCP) INV IN (W)= 889.90 (12" RCP) INV OUT (E)= 889.80 (12" RCP) INV OUT (E)= 890.45 (12" RCP) INV IN (E)= 889.40 (12" RCP) INV OUT (W)= 889.30 (12" RCP) INV OUT (W)= 889.55 (12" RCP) INV IN (NW)= 882.30 (36" RCP) INV IN (W)= 882.51 (36" RCP) INV OUT (SE)= 882.41 (36" RCP) INV IN (W)= 883.23 (36" RCP) INV OUT (E)= 883.13 (36" RCP) INV OUT (E)= 884.00 (36" RCP) INV IN (W)= 887.58 (12" RCP) INV OUT (E)= 888.87 (12" RCP) INV OUT (SE)= 880.80 (36" EX. STM) INV IN (E)= 889.65 (12" RCP) INV IN (SE)= 892.72 (12" RCP) INV OUT (W)= 892.62 (12" RCP) STORM SEWER PIPE DATA TABLE UPSTREAM STRUCTURE 497 499 602 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 DOWNSTREAM STRUCTURE 641 498 WQ601 600 602 603 604 605 606 607 608 602 610 611 612 613 614 605 616 SIZE 12" 12" 36" 15" 30" 30" 30" 30" 15" 15" 12" 12" 15" 15" 15" 15" 15" 15" 24" 24" MATERIAL RCP EX. STM EX. STM RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP LENGTH 32' 92' 32' 27' 123' 65' 187' 138' 137' 64' 41' 30' 15' 203' 90' 32' 103' 216' 132' 32' SLOPE 1.07% 1.07% -0.16% 0.26% 0.38% 0.29% 0.27% 0.23% 0.35% 0.31% 0.58% 0.53% 2.88% 0.66% 0.50% 0.47% 0.39% 0.28% 0.60% 0.47% STORM SEWER PIPE DATA TABLE UPSTREAM STRUCTURE 618 620 621 622 623 624 625 626 627 628 629 630 631 632 633 635 640 642 643 WQ601 DOWNSTREAM STRUCTURE 617 618 620 621 615 623 624 618 626 627 618 629 631A 631 632 634 499 620 642 602 SIZE 21" 15" 12" 12" 12" 12" 12" 15" 12" 12" 12" 12" 36" 36" 36" 12" 36" 12" 12" 15" MATERIAL RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP EX. STM RCP RCP RCP LENGTH 97' 342' 112' 32' 312' 97' 97' 122' 32' 126' 122' 32' 49' 287' 361' 46' 236' 113' 32' 27' SLOPE 0.97% 0.82% 1.37% 0.63% 0.58% 0.41% 0.41% 1.11% 1.09% 0.44% 0.98% 0.47% 0.22% 0.22% 0.21% 2.83% 0.36% 1.53% 0.62% 0.26% STORM SEWER NOTES 1. THE CONTRACTOR SHALL ADHERE TO ALL TERMS AND CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL N.P.D.E.S. PERMIT FOR STORMWATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND STORMWATER POLLUTION PREVENTION PLAN. 2. REFER TO THE INDIANA DEPARTMENT OF TRANSPORTATION (INDOT) STANDARD SPECIFICATIONS, LATEST EDITION, FOR BASIC MATERIALS AND CONSTRUCTION METHODS. 3. THE CONTRACTOR SHALL CONTACT APPLICABLE STATE UNDERGROUND LOCATION SERVICE AT LEAST 72 HOURS PRIOR TO ANY WORK AND SHALL CONTACT THE OWNER AND/OR ENGINEER SHOULD UTILITIES APPEAR TO BE IN CONFLICT WITH THE PROPOSED IMPROVEMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 4. THE PLANS SHOW THE LOCATIONS OF ALL KNOWN UTILITIES LOCATED WITHIN THE LIMITS OF CONSTRUCTION ACCORDING TO INFORMATION PROVIDED BY THE VARIOUS UTILITY COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS EVIDENCED BY OBSERVATION OF ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE ACCURACY OF THIS INFORMATION IS NOT GUARANTEED. 5. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE MAINS, CONDUITS, SERVICE LINES, AND OTHER FACILITIES WITHIN THE CONSTRUCTION LIMITS. THE LOCATION AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE UTILITY COMPANY) IS THE EXPRESSED RESPONSIBILITY OF THE CONTRACTOR. 6. THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITIES AND VERIFY ANY AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF ALL UTILITIES. 7. ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A. STANDARDS FOR WORKER SAFETY. 8. ANY PART OF STORM SEWER TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL. 9. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATIONS, SIZES, AND ELEVATIONS OF EXISTING UTILITIES, STRUCTURES, PIPES, PAVEMENTS AS RELATED TO THEIR WORK. NOTIFY ENGINEER OF ANY CONFLICT AND/OR DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS. 10. MINIMUM CLEARANCE BETWEEN STORM / SANITARY SEWER SYSTEMS AND DOMESTIC/FIRE LINE SERVICE, SHALL BE 10' HORIZONTAL AND 18" VERTICAL. 11. CONTRACTOR TO INSTALL CONCRETE CRADLES AT PIPE CROSSING WHEN THE VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWERS, WATER MAINS AND STORM SEWERS IS 18" OR LESS. 12. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO IT'S CONDITION PRIOR TO CONSTRUCTION. 13. WHEN PERFORMING EXCAVATIONS DURING PERIODS OF WET WEATHER, PROVIDE ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS. 14. COMPACTED "B" BORROW BACK FILL REQUIRED OVER ALL UTILITIES IN PAVED AREAS. 15. FOLLOW ALL LOCAL AND STATE CODES IN REFERENCE TO STORM SEWER INSTALLATION. 16. ALL EXISTING MANHOLE AND CATCH BASIN GRATES SHALL BE ADJUSTED TO NEW FINISH GRADE ELEVATIONS. 17. EXISTING PIPES WITHIN CONSTRUCTION LIMITS ARE TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS. 18. ALL STORM PIPE CONNECTIONS AT STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTIONS AT STRUCTURES ARE WATERTIGHT. 19. ALL STORM SEWER STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT AND SHALL HAVE TRAFFIC BEARING RING AND COVERS RATED FOR H20 LOADING. 20. ALL STORM SEWER STRUCTURES SHALL HAVE A SMOOTH AND UNIFORMLY POURED MORTAR CHANNEL FROM INVERT IN TO INVERT OUT. 21. NEW PIPES AND STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS PRIOR TO FINAL TURNOVER TO THE OWNER. 22. IF HDPE PIPE IS SPECIFIED, USE DUAL WALLED, HANCOR HQ, ADS N-12 PIPE OR APPROVED EQUAL. 23. ALL FITTINGS AND ACCESSORIES INCLUDING BUT NOT LIMITED TO END CAPS, CLEANOUTS, REDUCERS, ETC., SHALL BE HDPE MATERIAL; IF SPECIFIED, COMPARABLE WITH STORAGE PIPES. 24. PROVIDE BACKFILL WITH A MINIMUM OF 4" BEDDING MATERIAL OF #8 AGGREGATE COMPACTED IN 8" LIFTS TO 95% MAXIMUM DRY DENSITY. 25. VERIFY EXISTING STORM INVERT ELEVATIONS PRIOR TO STARTING NEW STORM SEWER CONNECTION. 26. PROPOSED STORM SEWERS TO BE OWNED BY HAMILTON COUNTY.C600 Storm PnPC604STORM PLAN & PROFILEW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C600 Storm PnP.dwgLAYOUT: C604DATE/TIME: August 31, 2022 - 10:57amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) STORM SEWER CONSTRUCTION NOTES THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. 11/07/22 C603 Storm DetailsC605STORM DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C603 Storm Details.dwgLAYOUT: C603DATE/TIME: August 31, 2022 - 10:57amPLOTTED BY: hansenbfhgENGINE E RS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, Indiana11/07/22 STRUCTURES 602 & WQ601 STR WQ601 CS-8 STR 602 108" DIA MANHOLE STRUCTURE INV = 883.27 INV = 883.27 WEIR ELEV = 887.84 INV = 883.41 INV = 883.41 INV = 883.34 INV = 883.34 27' OF 24" RCP 27' OF 24" RCP 30" RCP 30" RCP 4'-0" 15" RCP INV = 883.41 SECTION A-A SECTION B-B A A BB POND OUTLET STRUCTURE #640 NOT TO SCALE C603 Storm DetailsC606STORM DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C603 Storm Details.dwgLAYOUT: C604DATE/TIME: August 31, 2022 - 10:57amPLOTTED BY: hansenbfhgEN GI N E E RS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, Indiana14"8" 12"14" 9"4"4"18"3'-6" + DDVARIES6"6'-0"3'-6" + D6" #5 BARS 12" ON CENTER BOTH WAYS STRAIGHT HEADWALL WITH FLAP GATE (NO SCALE)D12"MIN.#5 BARS SPILLWAY DETAIL (NO SCALE) 11/07/22 W W W W W W W W EG G G G G G G G G G G G G G G G G G GG W OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU 146TH STREET VAR. WIDTH ROW W W W W WW W W W W W W W W W BIRDSONG LANE 146TH STREET DDDDD D DDDDDDDDDDDDDDDDDDDDDD D D D D D D D D DDD D D D DDDDDDDD DDDDDD D D DDDDDDDDDDDDDDDDDDDDDDDDDDPOND 1 26 1 7 8 9 11 12 10 13 28 27 24 25 23 16 17 18 14 3 2 5 4 29 30 31 32 33 34 1920 22 6 21 15 W W W W WWWWWWWWWWWWWWW WWWWWW W W W W WWWWWWWWWWWW W W W W WBEDFORDFALLS DR . GOWER DRIVE BIRDSONG LANEMITCHEL LANEBEDFORDFALLS DRIVE* ** * * * * * ** * * * * * * ** * * SANSANSANSAN C.A. A C.A. A C.A. B C.A. A C.A. C SAN SAN SAN SAN SAN SANSANSANSAN GUARDRAIL FMFMFMFMFMFMFM* * FMFMFMFMFMFMFMW W W W W G G G G G WOHU OHU OHU D D D DDDDDDDDDDDDDDDPOND 1 C.A. C Know what'sbelow. before you dig.Call R W S N E LEGEND W W T(A) E(A) G Gas Pole EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED HYDRANT WITH HYDRANT VALVE EXISTING HYDRANT WITH HYDRANT VALVE BUTTERFLY VALVE VALVE BLOWOFF ASSEMBLY AIR RELIEF VALVE PLUG REDUCER T.J. TEE M.J. SLEEVE CROSS CASING PIPE GAS LINES TELEPHONE LINES ELECTRIC LINES FUTURE DRIVEWAY ELECTRIC PEDESTAL PHONE PEDESTAL ELECTRICAL TRANSFORMER SINGLE WATER LATERAL TELEPHONE POLE GAS POLE INLET TREE GAS VALVE PARCEL ID ADAPTER BEND KICKER BLOCK METER PIT WATER MAIN NOTES: 1. SEE CONSTRUCTION STANDARDS OF CARMEL WATER FOR THE INSTALLATION OF WATER MAINS, SERVICE LINES, METERS, AND APPURTENANCES. 2. MINIMUM COVER OVER TOP OF ALL WATER MAINS TO BE 54 INCHES FROM FINISHED GRADE. 3. ALL VALVES ARE TO BE INSTALLED WITHIN 10' OF AN INTERSECTION OR NEAR A FIRE HYDRANT. 4. VALVES MUST HAVE POSI-CAP OR EQUIVALENT, FOR VALVE BOX STABILIZATION AND CENTERING. 5. THE WATER MAIN MUST MAINTAIN A MINIMUM OF 10 FEET OF SEPARATION WITH THE SEWER MAIN AT ALL TIMES. 6. HYDRANTS SHALL BE PER THE REQUIREMENTS OF THE LOCAL WATER UTILITY. 7. FIRE HYDRANTS SHALL HAVE 5 INCH STORZ CONNECTION (MUELLER MODEL 290220 FOR CASTING AND 290221 CAP OR APPROVED EQUAL). THE 5 INCH STORZ CONNECTION SHALL FACE THE STREET. HYDRANTS SHALL BE PLACED BETWEEN THE CURB AND THE SIDEWALK IN THE RIGHT OF WAY. 8. INSTALL ALL DUCTILE IRON WATER MAINS AND ACCESSORIES IN ACCORDANCE WITH AWWA C600. 9. INSTALL ALL PVC WATER MAINS AND ACCESSORIES IN ACCORDANCE WITH AWWA C900. 10. WRAP ALL FITTINGS IN POLYETHYLENE ENCASEMENT. 11. THE MAXIMUM SPACING BETWEEN FIRE HYDRANTS IN RESIDENTIAL NEIGHBORHOODS AND RESIDENTIALLY ZONES AREAS SHALL BE 500 FEET. 12. ALL WATER TO BE RESTRAINED CARMEL WATER STANDARDS. 13. WATER AVAILABILITY FEES WILL BE PAID AT THE TIME OF ACQUIRING THE BUILDING PERMITS. 14. CARMEL WATER INSPECTION STAFF MUST BE NOTIFIED 48 HOURS PRIOR TO COMMENCING WITH NEW WATER MAIN CONSTRUCTION.C700 Water PlanC700WATER PLANW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C700 Water Plan.dwgLAYOUT: C700DATE/TIME: August 31, 2022 - 10:58amPLOTTED BY: hansenbfhgEN G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaPROJECT BM HCBR_5 HAMILTON COUNTY CONTROL DISK AT THE NORTH END OF THE EAST HEADWALL OF DITCH ROAD OVER HENLEY CREEK. ELEV. 888.34 (NAVD 88) SITE TBM MAG SPIKE IN UTILITY POLE APPROXIMATELY 30' WEST OF EAST CONCRETE ENTRANCE AND APPROXIMATELY 45' SOUTH OF 146TH STREET ELEV.897.25' (NAVD 88) MAG SPIKE IN UTILITY POLE APPROXIMATELY 60' WEST OF WEST CONCRETE ENTRANCE AND APPROXIMATELY 30' SOUTH OF 146TH STREET ELEV. 893.54' (NAVD 88) LIMITS OF DISTURBANCED 11/07/22 C700 Water SpecsC701WATER SPECIFICATIONS & DETAILSW200515BCHW200515 02-16-2022DASJRV947 W. 146TH STREET, CARMEL, INBEDFORD FALLS OF CARMEL10 9 abcd8 7 6 efgh10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYeDATE:1 LOCATION: H:\2020\W200515\Engineering\design\conset\C700 Water Specs.dwgLAYOUT: C701DATE/TIME: August 31, 2022 - 10:58amPLOTTED BY: hansenbfhgENGINE E RS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild w ith conf idence.SMPart of the NW/4 of Section 22, Township 18 North, Range 3 East, Clay Township, Hamilton County, Indiana11/07/22