HomeMy WebLinkAboutBellevue Full SetBELLEVUE
CARMEL, INC1.0REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comCOVERCOVER Lennar Homes of Indiana, Inc.UTILITY CONTACT INFORMATION:LOCATION MAPSOILS MAPSOILS LEGENDSITE MAPAREA LOCATION MAP: STATE OF INDIANAPROJECT LOCATION:CITY OF CARMELHAMILTON COUNTYOVERALL GENERAL PROJECT NOTES:SURVEYOR:STORM WATER ADMIN.:CABLE:WATER:ELECTRIC:SANITARY:DEPARTMENT:GAS:TELEPHONE:CIVIL ENGINEER:HWC ENGINEERING135 N. PENNSYLVANIA ST., SUITE 2800INDIANAPOLIS, IN 46204317-347-3663mmaple@hwcengineering.comCARMEL ENGINEERINGCARMEL ENGINEERING DEPT.CONTACT: KEITH LASH9025 NORTH RIVER ROAD, SUITE 100INDIANAPOLIS, INDIANA 46240(317) 659-3200keith.lash@lennar.comBENCHMARK INFORMATION:ZONE DISTRICT: COLLEGE & 116TH PUD, ORD. Z-626-17CARMEL GENERAL NOTES:DOCKET NO. 18060011 SPLAND DESCRIPTION:SHEET LIST TABLESheet TitleSheet DescriptionC1.0COVERC1.3-1.4SITE IMPROVEMENTS PLANC1.1-1.2PRE-CONSTRUCTION STORMWATER POLLUTIONPREVENTION AND DEMOLITION PLANC1.9-1.10POST CONSTRUCTION STORMWATERPOLLUTION PREVENTION PLANC4.0-4.2STORM SEWER PLAN & PROFILEC6.0-6.4SANITARY SEWER PLAN & PROFILECONSTRUCTION DETAILSC8.5-8.7STORMWATER POLLUTION PREVENTION NOTESC8.0STORMWATER POLLUTION PREVENTION DETAILSC8.1-8.4C1.5-1.6GRADING & DRAINAGE PLANCTRWD DETAILSC8.8CTRWD SPECIFICATIONSC8.9C1.7-1.8UTILITY PLANCARMEL WATER DETAILSC8.10C2.0-2.1STREET PLAN & PROFILEC3.0LANDSCAPE PLANL1.0-1.1BUILDING FOUNDATION LANDSCAPE PLANL1.2-1.5ENTRANCE & MAINTENANCE OF TRAFFIC PLANLANDSCAPE DETAILSL1.6S1.1ALTA SURVEY (REFERENCE PURPOSES ONLY)PHOTOMETRIC PLANPH1SITE FURNISHING DETAILSL1.7S1.2EXISTING PROJECT SITE LAYOUTBELLEVUECARMEL, INTOTAL SITE DISTURBANCE = 3.96ACTOTAL LOT COVERAGE = 2.77 ACTOTAL % LOT COVERAGE = 70%
RRLANDCADD 1987
LANDCADD 1987
LANDCADD 1987
LANDCADD 1987LANDCADD 1987LANDCADD 1987 LANDCADD 1987LANDCADD 1987LANDCADD 1987 LANDCADD 1987LANDCADD 1987 LANDCADD 1987 LANDCADD 1987 LANDCADD 1987
BELLEVUE
CARMEL, INC1.1REVISIONSPRE-CONSTRUCTION STORMWATERPOLLUTION PREVENTION ANDDEMOLITION PLANPRE-CONSTRUCTION STORMWATER POLLUTION
PREVENTION AND DEMOLITION PLAN 0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!BENCHMARK INFORMATION:INDIANAPOLIS - TERRE HAUTEMUNCIE - LAFAYETTE - NEW ALBANYwww.hwcengineering.comLEGENDTHIS SHEET TO BE USED FOREROSION CONTROL ONLY.PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL:NOTE:SEE SHEET C8.0 FOR A LIST IN SEQUENCEOF CONSTRUCTION ACTIVITIES.DEMOLITION GENERAL NOTES:CARMEL GENERAL NOTES:INDEX OF SWPPP ELEMENTSDEMOLITION KEYNOTES:#STORMWATER POLLUTIONPREVENTION NOTES:LEGEND:EXISTINGREMOVENOTE:CONTRACTOR SHALL PROTECT THE EXISTING CITY DUAL DUCTBANK IN THE RIGHT-OF-WAY. IN THE EVENT OF CONFLICT WITHTHE PROPOSED IMPROVEMENTS, RELOCATION OF THE DUAL DUCTBANK AND ALL ASSOCIATED/APPURTENANT/ANCILLARY ITEMSSHALL BE THE SOLE RESPONSIBILITY OF THE DEVELOPER SUBJECTTO REVIEW AND APPROVAL OF THE CITY.NOTE:ALL EXISTING PERIMETER ROAD DRAINAGE STRUCTURES ANDBRIDGES ACROSS THE FRONTAGE OF THIS DEVELOPMENT AREINDICATED ON THE PLANS. PROVISIONS HAVE BEEN MADE TOIMPROVE OR REPLACE ANY DRAINAGE STRUCTURES ANDBRIDGES AS NECESSARY OR AS REQUESTED BY THE CITY TOACCOMMODATE THE PAVEMENT WIDENING, AUXILIARY LANES,MULTI-USE PATH, AND ANY OTHER REQUIRED IMPROVEMENTS TOTHE PROPERTY OR THE ROADWAY. THE COST TO IMPROVE ORREPLACE ANY DRAINAGE STRUCTURES AND BRIDGES WILL BEBORNE BY THE DEVELOPER.NOTE:CURB REMOVAL SHALL BE TO THE NEAREST JOINT PAST PAST THEREQUIRED LIMITS OF REMOVAL AND CURB MUST BE SAWCUT ATTHE REQUIRED JOINT.**
BELLEVUE
CARMEL, INC1.2REVISIONSPRE-CONSTRUCTION STORMWATERPOLLUTION PREVENTION ANDDEMOLITION PLANPRE-CONSTRUCTION STORMWATER POLLUTION
PREVENTION AND DEMOLITION PLAN INDIANAPOLIS - TERRE HAUTEMUNCIE - LAFAYETTE - NEW ALBANYwww.hwcengineering.com0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!BENCHMARK INFORMATION:THIS SHEET TO BE USED FOREROSION CONTROL ONLY.PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL:NOTE:SEE SHEET C8.0 FOR A LIST IN SEQUENCEOF CONSTRUCTION ACTIVITIES.DEMOLITION GENERAL NOTES:CARMEL GENERAL NOTES:INDEX OF SWPPP ELEMENTSDEMOLITION KEYNOTES:#STORMWATER POLLUTIONPREVENTION NOTES:LEGEND:EXISTINGREMOVENOTE:CONTRACTOR SHALL PROTECT THE EXISTING CITY DUAL DUCTBANK IN THE RIGHT-OF-WAY. IN THE EVENT OF CONFLICT WITHTHE PROPOSED IMPROVEMENTS, RELOCATION OF THE DUAL DUCTBANK AND ALL ASSOCIATED/APPURTENANT/ANCILLARY ITEMSSHALL BE THE SOLE RESPONSIBILITY OF THE DEVELOPER SUBJECTTO REVIEW AND APPROVAL OF THE CITY.NOTE:ALL EXISTING PERIMETER ROAD DRAINAGE STRUCTURES ANDBRIDGES ACROSS THE FRONTAGE OF THIS DEVELOPMENT AREINDICATED ON THE PLANS. PROVISIONS HAVE BEEN MADE TOIMPROVE OR REPLACE ANY DRAINAGE STRUCTURES ANDBRIDGES AS NECESSARY OR AS REQUESTED BY THE CITY TOACCOMMODATE THE PAVEMENT WIDENING, AUXILIARY LANES,MULTI-USE PATH, AND ANY OTHER REQUIRED IMPROVEMENTS TOTHE PROPERTY OR THE ROADWAY. THE COST TO IMPROVE ORREPLACE ANY DRAINAGE STRUCTURES AND BRIDGES WILL BEBORNE BY THE DEVELOPER.LEGEND*
116th StreetCollege SignWet Pond AreaAve.GOLBORNE STREETFULHAM STREET
LANGFORD STREETHUFFINGTON STREET
BELLEVUE
CARMEL, INC1.3REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comSITE IMPROVEMENTS PLANSITE IMPROVEMENTS PLAN 0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!BENCHMARK INFORMATION:GEOMETRIC LAYOUT NOTES:CARMEL GENERAL NOTES:SITE IMPROVEMENT KEYNOTES:#LEGEND:EXISTINGPROPOSEDSITE IMPROVEMENT GENERAL NOTES:FLOOD HAZARD STATEMENT:FUTURE ROUNDABOUT LINEWORK SHOWN FORREFERENCE PURPOSES ONLY”PARKING REQUIREMENTS
116th StreetCollege SignWet Pond AreaAve.GOLBORNE STREETFULHAM STREET
LANGFORD STREETHUFFINGTON STREET
BELLEVUE
CARMEL, INC1.3REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comSITE IMPROVEMENTS PLANSITE IMPROVEMENTS PLAN 0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!BENCHMARK INFORMATION:GEOMETRIC LAYOUT NOTES:CARMEL GENERAL NOTES:SITE IMPROVEMENT KEYNOTES:#LEGEND:EXISTINGPROPOSEDSITE IMPROVEMENT GENERAL NOTES:FLOOD HAZARD STATEMENT:FUTURE ROUNDABOUT LINEWORK SHOWN FORREFERENCE PURPOSES ONLY”PARKING REQUIREMENTS
College SignWet Pond AreaAve.GOLBORNE STREETFULHAM STREET HUFFINGTON STREET
BELLEVUE
CARMEL, INC1.4REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comSITE IMPROVEMENTS PLANSITE IMPROVEMENTS PLAN 0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!BENCHMARK INFORMATION:GEOMETRIC LAYOUT NOTES:”CARMEL GENERAL NOTES:SITE IMPROVEMENT KEYNOTES:#LEGEND:EXISTINGPROPOSEDSITE IMPROVEMENT GENERAL NOTES:FLOOD HAZARD STATEMENT:PARKING REQUIREMENTSFUTURE ROUNDABOUT LINEWORK SHOWN FORREFERENCE PURPOSES ONLY
116th StreetCollege SignWet Pond AreaAve.GOLBORNE STREETFULHAM STREET
LANGFORD STREETHUFFINGTON STREETPOND ELEV=853.90POND ELEV=853.55POND ELEV=853.90POND ELEV=853.90POND ELEV=853.55POND ELEV=853.35POND ELEV=853.58POND ELEV=853.15POND ELEV=853.50BELLEVUE
CARMEL, INC1.5REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comGRADING & DRAINAGEPLANGRADING & DRAINAGE PLAN FUTURE ROUNDABOUT LINEWORK SHOWN FORREFERENCE PURPOSES ONLY0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!BENCHMARK INFORMATION:CARMEL GENERAL NOTES:”LEGEND:EXISTINGPROPOSEDEARTHWORK NOTES:FLOOD HAZARD STATEMENT:
College SignWet Pond AreaAve.GOLBORNE STREETFULHAM STREET HUFFINGTON STREETPOND ELEV=853.90POND ELEV=853.70POND ELEV=853.55POND ELEV=853.90POND ELEV=853.80POND ELEV=853.55POND ELEV=853.35POND ELEV=853.5POND ELEV=854.50POND ELEV=854.50POND ELEV=853.75POND ELEV=853.58POND ELEV=853.15BELLEVUE
CARMEL, INC1.6REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comGRADING & DRAINAGEPLANGRADING & DRAINAGE PLAN FUTURE ROUNDABOUT LINEWORK SHOWN FORREFERENCE PURPOSES ONLY0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!BENCHMARK INFORMATION:CARMEL GENERAL NOTES:”LEGEND:EXISTINGPROPOSEDEARTHWORK NOTES:FLOOD HAZARD STATEMENT:
116th StreetCollege SignWet Pond AreaAve.GOLBORNE STREETFULHAM STREET
LANGFORD STREETHUFFINGTON STREET
BELLEVUE
CARMEL, INC1.7REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comUTILITY PLANUTILITY PLAN FUTURE ROUNDABOUT LINEWORK SHOWN FORREFERENCE PURPOSES ONLY0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!BENCHMARK INFORMATION:CARMEL GENERAL NOTES:”LEGEND:EXISTINGPROPOSEDUTILITY NOTES:SANITARY SEWER NOTES:STORM SEWER NOTES:SITE UTILITY PLAN KEYNOTES:#NOTE:SEE SHEET C1.8 FOR STORM SEWER DATATABLE.NOTE:CONTRACTOR SHALL PROTECT THE EXISTING CITY DUAL DUCTBANK IN THE RIGHT-OF-WAY. IN THE EVENT OF CONFLICT WITHTHE PROPOSED IMPROVEMENTS, RELOCATION OF THE DUAL DUCTBANK AND ALL ASSOCIATED/APPURTENANT/ANCILLARY ITEMSSHALL BE THE SOLE RESPONSIBILITY OF THE DEVELOPER SUBJECTTO REVIEW AND APPROVAL OF THE CITY.NOTE:ALL EXISTING PERIMETER ROAD DRAINAGE STRUCTURES ANDBRIDGES ACROSS THE FRONTAGE OF THIS DEVELOPMENT AREINDICATED ON THE PLANS. PROVISIONS HAVE BEEN MADE TOIMPROVE OR REPLACE ANY DRAINAGE STRUCTURES ANDBRIDGES AS NECESSARY OR AS REQUESTED BY THE CITY TOACCOMMODATE THE PAVEMENT WIDENING, AUXILIARY LANES,MULTI-USE PATH, AND ANY OTHER REQUIRED IMPROVEMENTS TOTHE PROPERTY OR THE ROADWAY. THE COST TO IMPROVE ORREPLACE ANY DRAINAGE STRUCTURES AND BRIDGES WILL BEBORNE BY THE DEVELOPER.
College SignWet Pond AreaAve.GOLBORNE STREETFULHAM STREET HUFFINGTON STREET
BELLEVUE
CARMEL, INC1.8REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comUTILITY PLANUTILITY PLAN FUTURE ROUNDABOUT LINEWORK SHOWN FORREFERENCE PURPOSES ONLY0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!BENCHMARK INFORMATION:CARMEL GENERAL NOTES:”LEGEND:EXISTINGPROPOSEDUTILITY NOTES:SANITARY SEWER NOTES:STORM SEWER NOTES:SITE UTILITY PLAN KEYNOTES:#NOTE:SEE SHEET C1.8 FOR STORM SEWER DATATABLE.NOTE:CONTRACTOR SHALL PROTECT THE EXISTING CITY DUAL DUCTBANK IN THE RIGHT-OF-WAY. IN THE EVENT OF CONFLICT WITHTHE PROPOSED IMPROVEMENTS, RELOCATION OF THE DUAL DUCTBANK AND ALL ASSOCIATED/APPURTENANT/ANCILLARY ITEMSSHALL BE THE SOLE RESPONSIBILITY OF THE DEVELOPER SUBJECTTO REVIEW AND APPROVAL OF THE CITY.NOTE:ALL EXISTING PERIMETER ROAD DRAINAGE STRUCTURES ANDBRIDGES ACROSS THE FRONTAGE OF THIS DEVELOPMENT AREINDICATED ON THE PLANS. PROVISIONS HAVE BEEN MADE TOIMPROVE OR REPLACE ANY DRAINAGE STRUCTURES ANDBRIDGES AS NECESSARY OR AS REQUESTED BY THE CITY TOACCOMMODATE THE PAVEMENT WIDENING, AUXILIARY LANES,MULTI-USE PATH, AND ANY OTHER REQUIRED IMPROVEMENTS TOTHE PROPERTY OR THE ROADWAY. THE COST TO IMPROVE ORREPLACE ANY DRAINAGE STRUCTURES AND BRIDGES WILL BEBORNE BY THE DEVELOPER.
RRLANDCADD 1987 LANDCADD 1987 LANDCADD 1987 LANDCADD 1987
116th StreetCollege SignWet Pond AreaAve.GOLBORNE STREETFULHAM STREET
LANGFORD STREETHUFFINGTON STREET
BELLEVUE
CARMEL, INC1.9REVISIONSPOST CONSTRUCTIONSTORMWATER POLLUTIONPREVENTION PLANPOST CONSTRUCTION STORMWATER
POLLUTION PREVENTION PLAN 0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!BENCHMARK INFORMATION:INDIANAPOLIS - TERRE HAUTEMUNCIE - LAFAYETTE - NEW ALBANYwww.hwcengineering.comTHIS SHEET TO BE USED FOREROSION CONTROL ONLY.PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL:NOTE:SEE SHEET C8.0 FOR A LIST IN SEQUENCEOF CONSTRUCTION ACTIVITIES.CARMEL GENERAL NOTES:INDEX OF SWPPP ELEMENTSLEGENDRRSOILS MAPSTORMWATER POLLUTIONPREVENTION NOTES:LEGEND:EXISTINGPROPOSEDFUTURE ROUNDABOUT LINEWORK SHOWN FORREFERENCE PURPOSES ONLYGRASS/SEED SCHEDULE
College SignAve.GOLBORNE STREETBELLEVUE
CARMEL, INC1.10REVISIONSPOST CONSTRUCTIONSTORMWATER POLLUTIONPREVENTION PLANPOST CONSTRUCTION STORMWATER
POLLUTION PREVENTION PLAN INDIANAPOLIS - TERRE HAUTEMUNCIE - LAFAYETTE - NEW ALBANYwww.hwcengineering.com0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!BENCHMARK INFORMATION:THIS SHEET TO BE USED FOREROSION CONTROL ONLY.PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL:NOTE:SEE SHEET C8.0 FOR A LIST IN SEQUENCEOF CONSTRUCTION ACTIVITIES.CARMEL GENERAL NOTES:INDEX OF SWPPP ELEMENTSSTORMWATER POLLUTIONPREVENTION NOTES:LEGEND:EXISTINGPROPOSEDFUTURE ROUNDABOUT LINEWORK SHOWN FORREFERENCE PURPOSES ONLYLEGENDRR
116th StreetCollege SignWet Pond AreaAve.GOLBORNE STREETFULHAM STREET
LANGFORD STREETHUFFINGTON STREETPOND ELEV=853.90POND ELEV=853.70POND ELEV=853.55POND ELEV=853.90POND ELEV=853.90POND ELEV=853.80POND ELEV=853.55POND ELEV=853.35POND ELEV=853.5POND ELEV=854.50POND ELEV=854.50POND ELEV=853.75POND ELEV=853.58POND ELEV=853.15POND ELEV=853.50BELLEVUE
CARMEL, INC1.11REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comOVERALL GRADING PLANOVERALL GRADING PLAN FUTURE ROUNDABOUT LINEWORK SHOWN FORREFERENCE PURPOSES ONLY0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!BENCHMARK INFORMATION:LEGEND:EXISTINGPROPOSED
FULHAM STREETFULHAM STREETSTREET PROFILEBELLEVUE
CARMEL, INC2.00'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!REVISIONSSTREET PLAN & PROFILESTREET PLAN & PROFILE LEGEND:EXISTINGPROPOSEDBENCHMARK INFORMATION:INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.com
GOLBORNE STREETCollege SignAve.GOLBORNE STREETBELLEVUE
CARMEL, INC2.10'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!LEGEND:EXISTINGPROPOSEDREVISIONSSTREET PLAN & PROFILESTREET PLAN & PROFILE BENCHMARK INFORMATION:STREET PROFILEINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.com
College Ave.Street "B"116th StreetCollege Ave.Street "B"116th StreetBELLEVUE
CARMEL, IN
ENTRANCE & MAINTENANCE OF TRAFFIC PLANC3.00'10'20'30'(IN FEET)GRAPHIC SCALECall 811 or 800-382-5544 Before you Dig!REVISIONS LEGEND:GOLBORNE STREET & COLLEGE AVENUEFULHAM STREET & 116TH STREETEXISTINGPROPOSEDGENERAL NOTESGOLBORNE STREET & COLLEGE AVENUEFULHAM STREET & 116TH STREETBENCHMARK INFORMATION:ENTRANCE AT FULHAM STREET & 116TH STREETNOTES:1.ALL EXISTING ROADS MUST BE BROUGHT BACK TO ORIGINAL OR BETTER CONDITION,INCLUDING BUT NOT LIMITED TO STRIPING, STONE SHOULDERS AND SIGNAGE.REPAIRS (i.e. STRIPING) SHALL COINCIDE WITH THE ADJOINING ROAD2.UTILITY CONFLICTS (INCLUDING UTILITY POLES) MUST BE COMPLETELY RESOLVEDPRIOR TO CONSTRUCTION OF ACCEL/DECEL LANES, PASSING BLISTER LANES AND/ORLEFT TURN LANES. CONSTRUCTION OF THESE LANES INCLUDES BUT IS NOT LIMITEDTO EXCAVATION, EMBANKMENT, PAVING AND SUBGRADE PREPARATION.GENERAL NOTESCARMEL GENERAL NOTES:ENTRANCE & MAINTENANCEOF TRAFFIC PLANENTRANCE AT GOLBORNE STREET & COLLEGE AVENUEINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.com
116th StreetLANGFORD STREETHUFFINGTON STREET
College SignAve.C4.0REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comSANITARY SEWER PLAN &PROFILE BELLEVUE
CARMEL, IN
SANITARY SEWER PLAN & PROFILESANITARY PROFILE0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!LEGEND:EXISTINGPROPOSEDNOTE:AN APOXY LINING PER CTRWD STANDARDSSHALL BE APPLIED TO THE THREE DOWNSTREAMMANHOLES FROM THE CONNECTION POINTNOTE:CAP AND GROUTABANDONED FORCEMAINAFTER RE-ROUTE.NOTE:PAVEMENT CUT ANDREPAIR PER CITY OFCARMEL REQUIREMENTS.
Wet
P
o
n
d
A
r
e
a
G
O
L
B
O
R
N
E
S
T
R
E
E
TFULHAM STREETLANGFORD STREETHUFFINGTON STREETC4.1REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comSANITARY SEWER PLAN &PROFILE BELLEVUE
CARMEL, IN
SANITARY SEWER PLAN & PROFILESANITARY PROFILE0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!LEGEND:EXISTINGPROPOSED
FULHAM STREETC4.2REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comSANITARY SEWER PLAN &PROFILE BELLEVUE
CARMEL, IN
SANITARY SEWER PLAN & PROFILESANITARY PROFILE0'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!LEGEND:EXISTINGPROPOSEDNOTE:CONNECTION OF EXISTING LIFT STATION TOPROPOSED STRUCTURE #22. THE CONNECTIONSHALL BE AT THE INVERT OF THE MANHOLETHROUGH A POURED BENCHWALLNOTE:CUT FORCEMAIN OUTSIDEOF FENCE AND REROUTETO NEW MANHOLE #22.
STORM PROFILEBELLEVUE
CARMEL, INC6.00'(IN FEET)GRAPHIC SCALE20'40'60'Call 811 or 800-382-5544 Before you Dig!LEGEND:EXISTINGPROPOSEDREVISIONSSTORM SEWER PLAN &PROFILESTORM SEWER PLAN & PROFILE BENCHMARK INFORMATION:GENERAL NOTES:NOTE:ALL STORM CASTINGS SHALL HAVE A NOTE:"NO DUMPING, DRAINS TO WATERWAYS"INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.com
FULHA
M STREET
BELLEVUE
CARMEL, INC6.1Call 811 or 800-382-5544 Before you Dig!LEGEND:EXISTINGPROPOSEDREVISIONSSTORM SEWER PLAN &PROFILESTORM SEWER PLAN & PROFILE GENERAL NOTES:0'(IN FEET)GRAPHIC SCALE20'40'60'BENCHMARK INFORMATION:STORM PROFILENOTE:ALL STORM CASTINGS SHALL HAVE A NOTE:"NO DUMPING, DRAINS TO WATERWAYS"INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.com
Wet Pond AreaGOLBORNE STREETFULHAM STREET
LANGFORD STREETHUFFINGTON STREET
BELLEVUE
CARMEL, INC6.2Call 811 or 800-382-5544 Before you Dig!LEGEND:EXISTINGPROPOSEDREVISIONSSTORM SEWER PLAN &PROFILESTORM SEWER PLAN & PROFILE BENCHMARK INFORMATION:0'(IN FEET)GRAPHIC SCALE20'40'60'GENERAL NOTES:STORM PROFILENOTE:ALL STORM CASTINGS SHALL HAVE A NOTE:"NO DUMPING, DRAINS TO WATERWAYS"INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.com
LANGFORD STREETGOLBORNE STREETBELLEVUE
CARMEL, INC6.3Call 811 or 800-382-5544 Before you Dig!LEGEND:EXISTINGPROPOSEDREVISIONSSTORM SEWER PLAN &PROFILESTORM SEWER PLAN & PROFILE BENCHMARK INFORMATION:0'(IN FEET)GRAPHIC SCALE20'40'60'GENERAL NOTES:STORM PROFILENOTE:ALL STORM CASTINGS SHALL HAVE A NOTE:"NO DUMPING, DRAINS TO WATERWAYS"INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.com
BELLEVUE
CARMEL, INC6.4Call 811 or 800-382-5544 Before you Dig!LEGEND:EXISTINGPROPOSEDREVISIONSSTORM SEWER PLAN &PROFILESTORM SEWER PLAN & PROFILE BENCHMARK INFORMATION:0'(IN FEET)GRAPHIC SCALE20'40'60'GENERAL NOTES:STORM PROFILENOTE:ALL STORM CASTINGS SHALL HAVE A NOTE:"NO DUMPING, DRAINS TO WATERWAYS"INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.com
BELLEVUE
CARMEL, INC8.0REVISIONSSTORMWATERPOLLUTION PREVENTIONNOTESSTORMWATER POLLUTION
PREVENTION NOTES INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comSTORMWATER POLLUTION PREVENTION PLAN INDEXSEEDING SCHEDULESOILS MAP (Not to scale)THIS SHEET TO BE USED FOREROSION CONTROL ONLY.PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL:LENNAR HOMES OF INDIANA, INC.Phone: (317) 846-3148STUART HUCKELBERRYOWNERS INFORMATIONLENNAR HOMES OF INDIANA, INC.Phone: (317) 846-3148INSPECTORS INFORMATIONALPHA EMCPhone: (317) 448-52389025 NORTH RIVER ROAD, SUITE 100CONTACT: STUART HUCKELBERRYINDIANAPOLIS, IN 46240rmueller@AlphaEMC.comLENNAR HOMES OF INDIANA, INC.Phone: (317) 846-3148STUART HUCKELBERRYRUSSELL MUELLER stuart.huckelberry@lennar.com··················SOIL DESCRIPTIONS/LIMITATIONS
BELLEVUE
CARMEL, INC8.1REVISIONSSTORMWATERPOLLUTION PREVENTIONDETAILSSTORMWATER POLLUTION
PREVENTION DETAILS INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comTHIS SHEET TO BE USED FOREROSION CONTROL ONLY.STAPLE PATTERN GUIDENOT-TO-SCALEEROSION CONTROL BLANKETCHANNEL INSTALLATIONSHORELINE INSTALLATIONSLOPE INSTALLATIONINDIVIDUAL LOT STORM WATER POLLUTION & PREVENTION DETAILNOT-TO-SCALETREE PROTECTION DETAILCOIR LOG (FIBER ROLL)COIR LOG (FIBER ROLL) ALONG CURBPERSON ONSITE RESPONSIBLE FOR EROSION CONTROL:LENNAR HOMES OF INDIANA, INC.Phone: (317) 846-3148STUART HUCKELBERRYNATIVE VEGETATION PROTECTIVE SIGN
BELLEVUE
CARMEL, INC8.2REVISIONSSTORMWATERPOLLUTION PREVENTIONDETAILSSTORMWATER POLLUTION
PREVENTION DETAILS INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comTHIS SHEET TO BE USED FOREROSION CONTROL ONLY.BEEHIVE PROTECTION DETAILNOT-TO-SCALEPERSON ONSITE RESPONSIBLE FOR EROSION CONTROL:LENNAR HOMES OF INDIANA, INC.Phone: (317) 846-3148STUART HUCKELBERRY
BELLEVUE
CARMEL, INC8.3REVISIONSSTORMWATERPOLLUTION PREVENTIONDETAILSSTORMWATER POLLUTION
PREVENTION DETAILS INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comTHIS SHEET TO BE USED FOREROSION CONTROL ONLY.········· ·· ······ ····· ··· ··· ····· ······ ······· ·PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL:LENNAR HOMES OF INDIANA, INC.Phone: (317) 846-3148STUART HUCKELBERRY
BELLEVUE
CARMEL, INC8.4REVISIONSSTORMWATERPOLLUTION PREVENTIONDETAILSSTORMWATER POLLUTION
PREVENTION DETAILS INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comTHIS SHEET TO BE USED FOREROSION CONTROL ONLY.PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL:LENNAR HOMES OF INDIANA, INC.Phone: (317) 846-3148STUART HUCKELBERRY
C8.5REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comCONSTRUCTION DETAILSCONSTRUCTION DETAILS 48" DIA. STORM SEWER MANHOLEINLET TYPE ASIZEB(ft)La(ft)W(ft)Thickness(in)12"36912"15"3.75811.7512"18"4.51014.512"24"6131912"30"7.51618.518"36"9202318"42"10.52225.518"RIP-RAP PLACEMENTPRE CAST CONCRETE END SECTIONPERMEABLE PAVER CROSS SECTION A-AWATER QUALITY DIVERSIONSTRUCTURE #220CONCRETE CURB TURNOUT (WITH DEPRESSED GUTTER)BELLEVUE
CARMEL, IN
C8.6REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comCONSTRUCTION DETAILSCONSTRUCTION DETAILS EXPANSION JOINTSCONTROL JOINTSCONCRETE SIDEWALK JOINT & FINISHING DETAILSCURB JOINT DETAILPAVEMENT MARKING DETAILSFULHAM & GOLBORNE CROSS SECTIONTYPICAL 20' ALLEY CROSS SECTION (INVERTED CROWN)TYPICAL 20' ALLEY CROSS SECTION BELLEVUE
CARMEL, IN
C8.6REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comCONSTRUCTION DETAILSCONSTRUCTION DETAILS EXPANSION JOINTSCONTROL JOINTSCONCRETE SIDEWALK JOINT & FINISHING DETAILSCURB JOINT DETAILPAVEMENT MARKING DETAILSFULHAM & GOLBORNE CROSS SECTIONTYPICAL 20' ALLEY CROSS SECTION (INVERTED CROWN)TYPICAL 20' ALLEY CROSS SECTION BELLEVUE
CARMEL, IN
C8.7REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comCONSTRUCTION DETAILSCONSTRUCTION DETAILS ASPHALT PAVEMENT LAP JOINT DETAILTYPE 3 HANDICAP ACCESS RAMPPOND OUTLET CONTROL STRUCTURE (STR.#103)VEHICLE BARRIER POSTPOND CROSS SECTIONEMERGENCY SPILLWAY CROSS SECTION & PATH1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.NOTES:2. DO NOT SCALE DRAWINGS.OPTIONAL FLOATING DEVICEBOTTOM OF POND 1. THE ONLY ASSEMBLY REQUIRED IS TO ATTACH THE MOTOR HOUSING TO THE BASE, WITH THE HARDWARE PROVIDED ANDTO ATTACH THE FLEXIBLE DISCHARGE HOSE.2. YOU WILL HAVE TO MEASURE THE DEPTH OF THE POND AT THE LOCATION YOU WILL BE INSTALLING YOUR UNIT. CUT YOURFLEXIBLE HOSE 0' TO 3' BELOW THE SURFACE. THE CLOSER TO THE SURFACE THE BIGGER THE WATER BOIL WILL BE. AFTERCUTTING THE HOSE TO PROPER LENGTH ATTACH THE HOSE TO THE DISCHARGE TUBE WITH THE STAINLESS STEEL HOSECLAMP. TIGHTEN SECURELY. THE UNIT IS NOW READ TO BE INSTALED IN YOUR POND.3. YOU YOU WILL NEED TWO (2) PIECES OF NYLON ROPE, ONE TO INSTALL YOUR UNIT WHICH SHOULD BE TWICE THE DEPTHOF YOUR POND AND ONE FOR RETRIEVAL, WHICH CAN EXTEND FROM YOUR AERATOR BASE TO SHORE OR FROM YOURAERATOR BASE TO YOUR FLOATING DEVICE.4. ONE END OF THE NYLON ROPE FOR YOUR RETRIEVAL LINE SHOULD BE ATTACHED THROUGH THE HOLE DRILLED IN THEAERATOR BASE, THE OTHER END SHOULD BE ATTACHED TO A FLOAT DEVICE OR BACK TO THE SHORE LINE. THIS LINE IS USEDTO REMOVE YOUR UNIT FROM THE WATER AFTER IT HAS BEEN INSTALLED.WARNING: NEVER REMOVE YOUR UNIT FROM THE POND BY PULLING ON THE POWER CABLE, DAMAGE TO THE UNIT WILLRESULT AND VOID THE WARRANTY.5. THE NYLON ROPE FOR INITIAL INSTALLATION IS RUN THROUGH THE S-HOOK ON THE UNIT. CAREFULLY LOWER THE UNIT TOTHE BOTTOM OF THE POND, MAKING SURE THE BASE SITS AS FLAT AS POSSIBLE. AFTER THE FINAL PLACEMENT, PULL ONE ENDOF THE ROPE OUT THE S-HOOK, DONT LEAVE THIS ROPE IN THE WATER.6. FOR INITIAL OPERATION, INTRODUCE YOUR AERATOR INTO THE PONDS ENVIRONMENT BY SETTING YOUR ON-OFF TIMER TOFOUR HOUR INTERVALS. NOTE: THE INSTALLATION ROPE ON 1-5 HP UNITS ARE RUN THROUGH THE S-HOOK ON THE DISCHARGE TUBE ASSEMBLY.THERE IS ALSO A S-HOOK ON THE FLOATTO TIE THE RETRIEVAL LINE TO. THIS AIDS IN REMOVAL OF UNIT.INSTALLING"S" HOOKINSTALLINGROPERETRIEVALLINESHORE ORFLOATPOND AERATOREXCLUDING EVAPORATION RATES AND EXTENDED DRY PERIODS, CONSTRUCTEDWET PONDS MUST BE ABLE TO HOLD NORMAL POOL ELEVATION. WET PONDSMUST BE LINED WITH A LOW PERMEABILITY LINER IF ONE OR MORE OF THEFOLLOWING ARE EVIDENT; INFILTRATION RATE OF SOILS IN A PROPOSED WET PONDLOCATION POSE A RISK TO THIS REQUIREMENT, IT IS FOUND THAT THE PONDCANNOT MAINTAIN NORMAL POOL DURING THE COURSE OF CONSTRUCTION, OR ITIS FOUND THAT THE POND CANNOT MAINTAIN NORMAL POOL PRIOR TOACCEPTANCE OF ALL INSTALLED IMPROVEMENTS BY THE CITY OF CARMEL. THELINER MUST BE DESIGNED BY A CERTIFIED ENGINEER AND THE LINER MUST BEACCEPTABLE TO THE CITY ENGINEER. LINER DETAILS AND LOCATIONS MUST BEINCLUDED IN AS-BUILT SUBMITTALS.BELLEVUE
CARMEL, INNOTE:MODEL #AQUA AIR ULTRA 1 - (13) HPPATHCROSS SECTION
C8.7REVISIONSINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comCONSTRUCTION DETAILSCONSTRUCTION DETAILS ASPHALT PAVEMENT LAP JOINT DETAILTYPE 3 HANDICAP ACCESS RAMPPOND OUTLET CONTROL STRUCTURE (STR.#103)VEHICLE BARRIER POSTPOND CROSS SECTIONEMERGENCY SPILLWAY CROSS SECTION & PATH1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.NOTES:2. DO NOT SCALE DRAWINGS.OPTIONAL FLOATING DEVICEBOTTOM OF POND 1. THE ONLY ASSEMBLY REQUIRED IS TO ATTACH THE MOTOR HOUSING TO THE BASE, WITH THE HARDWARE PROVIDED ANDTO ATTACH THE FLEXIBLE DISCHARGE HOSE.2. YOU WILL HAVE TO MEASURE THE DEPTH OF THE POND AT THE LOCATION YOU WILL BE INSTALLING YOUR UNIT. CUT YOURFLEXIBLE HOSE 0' TO 3' BELOW THE SURFACE. THE CLOSER TO THE SURFACE THE BIGGER THE WATER BOIL WILL BE. AFTERCUTTING THE HOSE TO PROPER LENGTH ATTACH THE HOSE TO THE DISCHARGE TUBE WITH THE STAINLESS STEEL HOSECLAMP. TIGHTEN SECURELY. THE UNIT IS NOW READ TO BE INSTALED IN YOUR POND.3. YOU YOU WILL NEED TWO (2) PIECES OF NYLON ROPE, ONE TO INSTALL YOUR UNIT WHICH SHOULD BE TWICE THE DEPTHOF YOUR POND AND ONE FOR RETRIEVAL, WHICH CAN EXTEND FROM YOUR AERATOR BASE TO SHORE OR FROM YOURAERATOR BASE TO YOUR FLOATING DEVICE.4. ONE END OF THE NYLON ROPE FOR YOUR RETRIEVAL LINE SHOULD BE ATTACHED THROUGH THE HOLE DRILLED IN THEAERATOR BASE, THE OTHER END SHOULD BE ATTACHED TO A FLOAT DEVICE OR BACK TO THE SHORE LINE. THIS LINE IS USEDTO REMOVE YOUR UNIT FROM THE WATER AFTER IT HAS BEEN INSTALLED.WARNING: NEVER REMOVE YOUR UNIT FROM THE POND BY PULLING ON THE POWER CABLE, DAMAGE TO THE UNIT WILLRESULT AND VOID THE WARRANTY.5. THE NYLON ROPE FOR INITIAL INSTALLATION IS RUN THROUGH THE S-HOOK ON THE UNIT. CAREFULLY LOWER THE UNIT TOTHE BOTTOM OF THE POND, MAKING SURE THE BASE SITS AS FLAT AS POSSIBLE. AFTER THE FINAL PLACEMENT, PULL ONE ENDOF THE ROPE OUT THE S-HOOK, DONT LEAVE THIS ROPE IN THE WATER.6. FOR INITIAL OPERATION, INTRODUCE YOUR AERATOR INTO THE PONDS ENVIRONMENT BY SETTING YOUR ON-OFF TIMER TOFOUR HOUR INTERVALS. NOTE: THE INSTALLATION ROPE ON 1-5 HP UNITS ARE RUN THROUGH THE S-HOOK ON THE DISCHARGE TUBE ASSEMBLY.THERE IS ALSO A S-HOOK ON THE FLOATTO TIE THE RETRIEVAL LINE TO. THIS AIDS IN REMOVAL OF UNIT.INSTALLING"S" HOOKINSTALLINGROPERETRIEVALLINESHORE ORFLOATPOND AERATOREXCLUDING EVAPORATION RATES AND EXTENDED DRY PERIODS, CONSTRUCTEDWET PONDS MUST BE ABLE TO HOLD NORMAL POOL ELEVATION. WET PONDSMUST BE LINED WITH A LOW PERMEABILITY LINER IF ONE OR MORE OF THEFOLLOWING ARE EVIDENT; INFILTRATION RATE OF SOILS IN A PROPOSED WET PONDLOCATION POSE A RISK TO THIS REQUIREMENT, IT IS FOUND THAT THE PONDCANNOT MAINTAIN NORMAL POOL DURING THE COURSE OF CONSTRUCTION, OR ITIS FOUND THAT THE POND CANNOT MAINTAIN NORMAL POOL PRIOR TOACCEPTANCE OF ALL INSTALLED IMPROVEMENTS BY THE CITY OF CARMEL. THELINER MUST BE DESIGNED BY A CERTIFIED ENGINEER AND THE LINER MUST BEACCEPTABLE TO THE CITY ENGINEER. LINER DETAILS AND LOCATIONS MUST BEINCLUDED IN AS-BUILT SUBMITTALS.BELLEVUE
CARMEL, INNOTE:MODEL #AQUA AIR ULTRA 1 - (13) HPPATHCROSS SECTION
BELLEVUE
CARMEL, INC8.8REVISIONSCTRWD DETAILSCTRWD DETAILS 1234567891110 INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.com
BELLEVUE
CARMEL, INC8.9REVISIONSCTRWDSPECIFICATIONSCTRWD SPECIFICATIONS INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.comINDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.com
BELLEVUE
CARMEL, INC8.10REVISIONSCARMEL WATERDETAILSCARMEL WATER DETAILS INDIANAPOLIS - TERRE HAUTELAFAYETTE - MUNCIE - NEW ALBANYwww.hwcengineering.com